• Title/Summary/Keyword: iPOWER

Search Result 5,706, Processing Time 0.038 seconds

An analysis about failures of the power converter in power plant (발전플랜트의 전력변환기 고장사례 분석)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.554-555
    • /
    • 2012
  • The failures in the power plant can lead to a dangerous situation according to the demand and supply of the electric power. The failure times of the domestic plant happens very often, and it has been reported as a significant loss by the power sales. Therefore, the power plant is demanded to maintain very well in order to produce a high quality of power. The rate of failures by the electricity facility is filled with 40[%] among the trouble in the failures of the power plant. The failures of power plant can cause serious accidents, magnificent losses, and chaos in our society. So, we require a significant plan to reduce such a serious problem. In this paper, I analysis the failure case of power converter in power plant, and I offer the better solution to be able to prevent the failures from power plant.

  • PDF

A Novel AC Voltage Regulator Topology (새로운 교류 전압조정회로 개발)

  • Lee, Jong-Moo;Byun, Young-Bok;Kim, Jong-Soo;Joe, Ki-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.459-461
    • /
    • 1991
  • This paper proposes a novel AC voltage regulator topology. The output voltage is varied by controlling voltage drop of the transformer which is connected with load in series. The waveform of output voltage is clamped sinusoidal, then harmonic components are remarkably decreased compared with conventional phase control method. The feasibility of proposed topology is verified experimentally.

  • PDF

Fuzzy Pre-Compensated PI Control of Active Filters

  • Singh, Bhim;Singhal, Varun
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • This paper deals with a new and improved control technique for shunt active filters (AF) used for compensating unwanted harmonic currents injected in the mains due to nonlinear varying loads. This work is motivated by the need to find a permanent solution to the rigorous hit and trial method for evaluating system parameters in an indirect control of AF. A fuzzy pre-compensated PI (Proportional-Integral) controller is used to fuzzify the reference DC voltage of AF to the controller input so that the overshoots and undershoots in its DC link voltage are minimized and the settling time is improved. A three-phase diode rectifier with R-L (Resistive-Inductive) load is used as a non-linear load to study the effectiveness of the proposed controller of the AF. Robustness to filter parameter variations, insensitivity to controller parameter variations, and transient response has been taken as performance evaluation parameters. The results are shown through simulations in Matlab using power system block sets to demonstrate the capability of the proposed controller of the AF.

An Empirical Study on Linux I/O stack for the Lifetime of SSD Perspective (SSD 수명 관점에서 리눅스 I/O 스택에 대한 실험적 분석)

  • Jeong, Nam Ki;Han, Tae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.54-62
    • /
    • 2015
  • Although NAND flash-based SSD (Solid-State Drive) provides superior performance in comparison to HDD (Hard Disk Drive), it has a major drawback in write endurance. As a result, the lifetime of SSD is determined by the workload and thus it becomes a big challenge in current technology trend of such as the shifting from SLC (Single Level Cell) to MLC (Multi Level cell) and even TLC (Triple Level Cell). Most previous studies have dealt with wear-leveling or improving SSD lifetime regarding hardware architecture. In this paper, we propose the optimal configuration of host I/O stack focusing on file system, I/O scheduler, and link power management using JEDEC enterprise workloads in terms of WAF (Write Amplification Factor) which represents the efficiency perspective of SSD life time especially for host write processing into flash memory. Experimental analysis shows that the optimum configuration of I/O stack for the perspective of SSD lifetime is MinPower-Dead-XFS which prolongs the lifetime of SSD approximately 2.6 times in comparison with MaxPower-Cfq-Ext4, the best performance combination. Though the performance was reduced by 13%, this contributions demonstrates a considerable aspect of SSD lifetime in relation to I/O stack optimization.

Safety assessment of Generation III nuclear power plant buildings subjected to commercial aircraft crash Part I: FE model establishment and validations

  • Liu, X.;Wu, H.;Qu, Y.G.;Xu, Z.Y.;Sheng, J.H.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.381-396
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part I, finite element (FE) models establishment and validations for both the aircrafts and NPP buildings are performed. (i) Airbus A320 and A380 aircrafts are selected as the representative medium and large commercial aircrafts, and the corresponding fine FE models including the skin, beam, fuel and etc. are established. By comparing the numerically derived impact force time-histories with the existing published literatures, the rationality of aircrafts models is verified. (ii) Fine FE model of the Chinese Zhejiang Sanao NPP buildings is established, including the detailed structures and reinforcing arrangement of both the containment and auxiliary buildings. (iii) By numerically reproducing the existing 1/7.5 scaled aircraft model impact tests on steel plate reinforced concrete (SC) panels and assessing the impact process and velocity time-history of aircraft model, as well as the damage and the maximum deflection of SC panels, the applicability of the existing three concrete constitutive models (i.e., K&C, Winfrith and CSC) are evaluated and the superiority of Winfrith model for SC panels under deformable missile impact is verified. The present work can provide beneficial reference for the integral aircraft crash analyses and structural damage assessment in the following two parts of this paper.

Measurements of the Vibrational Power Flow in Structure Beam by Using the Structural Intensity Method (Structural Intensity 법을 이용한 구조체의 진동전달량 측정)

  • ;Tichy, Jiri
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.231-238
    • /
    • 1994
  • This paper presents an experimental method to find the vibrational transmission characteristics of structures by using the structural intensity method which is used as the important techniques of active vibration control method. Experimental results are obtained from measurements performed on a structure beam by 2, 3 and 4 position linear accelerometr array (2, 3 and 4 structural intensity : 2, 3 and 4 S.I.) methods at near and farfield conditions. These results are compared with the measurement values of conventional power flow measurement method called input power measurement in order to verify the accuracy of structural intensity methods. To minimize the errors associated with 2, 3 and 4 S.I. methods, the measurement locations were selected by the result of modal analysis and the averaged data by the inter-change of accelerometer array was utilized. In 3 and 4 S.I. methods measured wavenumber instead of theoretical wavenumber was used. This paper shows that measurements of bending wave power flow by using 2, 3 and 4 S.I. methods can give accurate values under general field conditions in structural beam and the accuracy of 2, 3 S.I. methods is higher than 4 S.I. methods. Finally, 2 position linear accelerometer array method is suggested as the practical structural intensity technique.

  • PDF

Using Protective Relaying for Power Quality Monitoring (보호계전기를 이용한 전기품질 감시 기법 연구)

  • Bea, Y.J.;Lim, S.I.;Choi, I.S.;Lee, S.J.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.62-64
    • /
    • 2002
  • Power quality monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. Therefore, this paper is proposed to use digital protective relays for power quality monitoring. In addition, taking power quality events, Electrical magnetic phenomenon of IEEE std 1159, proposing that adaptive power quality event list consider limitation memory capacity and signal processing ability of protective relay. The prototype S/W of power quality analysis is also developed. Especially this prototype S/W analysis scheme is verified through many kinds of power quality events (gathering protective relay data) in EMTP simulation.

  • PDF

A New Control Scheme of Wind Farm Considering P,Q References (풍력 발전단지의 출력 지령값을 고려한 계통 연계 운영 방안)

  • Choi, Jung-Hyun;Park, Jin-Woo;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1172-1173
    • /
    • 2008
  • At the moment, the control ability of wind farms is a prime research concern for the grid integration of large wind farms, due to their required active role in the power system. As more wind turbines are installed, the power from wind energy will start to replace conventional generation units and its influence on power systems cannot be neglected. Besides, because of the intermittent nature of wind the output power of wind turbines fluctuates according to wind speed variation. Especially an isolated power system with small capacity such like Jeju needs more systematic solutions and regulations(grid code). This paper presents the idea of approach for centralized operating wind farm strategy to regulate the wind farm power production to the reference power ordered by the system operator. The doubly fed induction generator(DFIG) can control active and reactive power in feasible range. So wind farm comprised of DFIG has the possibility of a controllable component in the power system. The presented wind farm control has a hierarchical structure with both a wind farm control level and a wind turbine control level.

  • PDF