Steel hexagonal damper-brace system for efficient seismic protection of structures

  • Mohammad Mahdi, Javidan;Jinkoo, Kim
    • Steel and Composite Structures
    • /
    • 제45권5호
    • /
    • pp.683-695
    • /
    • 2022
  • Conventional braces are often used to provide stiffness to structures; however due to buckling they cannot be used as seismic energy dissipating elements. In this study, a seismic energy dissipation device is proposed which is comprised of a bracing member and a steel hysteretic damper made of steel hexagonal plates. The hexagonal shaped designated fuse causes formation of plastic hinges under axial deformation of the brace. The main advantages of this damper compared to conventional metallic dampers and buckling-restrained braces are the stable and controlled energy dissipation capability with ease of manufacture. The mechanical behavior of the damper is formulated first and a design procedure is provided. Next, the theoretical formulation and the efficiency of the damper are verified using finite element (FE) analyses. An analytical model of the damper is established and its efficiency is further investigated by applying it to seismic retrofit of a case study structure. The seismic performance of the structure is evaluated before and after retrofit in terms of maximum interstory drift ratio, top story displacement, residual displacement, and energy dissipation of dampers. Overall, the median of maximum interstory drift ratios is reduced from 3.8% to 1.6% and the residual displacement decreased in the x-direction which corresponds to the predominant mode shape of the structure. The analysis results show that the developed damper can provide cost-effective seismic protection of structures.

등방성 이력형 강재댐퍼를 이용한 RC 라멘조 아파트건물의 지진응답 개선 (Mitigating Seismic Response of RC Framed Apartment Building Using Isotropic Hysteretic Steel Dampers)

  • 천영수;방종대
    • 토지주택연구
    • /
    • 제5권2호
    • /
    • pp.107-114
    • /
    • 2014
  • 수동형 제진장치를 이용하는 제진구조는 수년간 개발이 지속되고 있으며, 1990년대 중반이후로 여러 나라들에서 실무적인 적용이 빠르게 증가되고 있다. 국내의 경우 이러한 제진장치 중 강재이력형 댐퍼가 비교적 저렴한 비용과 설치와 관리가 용이하다는 이유로 건물의 내진설계를 위하여 보편적으로 많이 적용되고 있다. 이 논문에서는 건물의 지진응답을 개선하기 위하여 적용된 소위 카고메댐퍼로 불리우는 등방성 강재이력형 댐퍼(Isotropic Hysteretic Metallic Damper, IHMD)의 유효성에 대한 해석적인 사례연구를 제시하고 있다. 연구대상 건물은 18층 규모의 철근콘크리트 라멘조 아파트건물로 해석결과를 통하여 IHMD의 실효성을 실증적으로 보여주고 있다. 해석결과는 IHMD가 건물의 지진응답을 줄일 수 있는 매우 효과적인 방법임을 검증하고 있다.

동조질량감쇠기를 이용한 비선형이력 구조물의 지진응답제어 (Seismic Response Control of Nonlinear Hysteretic Structures Using Tuned Mass Damper)

  • 이상현;정란;우성식;이정우;최기영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.206-209
    • /
    • 2006
  • This study presents the performance evaluation of a tuned mass damper (TMD) for controlling seismic responses of the nonlinear hysteretic structure represented by a Bouc-Wen model, considering that the general reinforce concrete building structures subject to earthquake load show nonlinear hysteretic behavior. Numerical analysis result indicates that the performance of a passive TMD of which design parameters are optimized for a elastic structure deteriorates when the hysteretic portion of the structural responses increases, while a semi-actively operated TMD shows about 15-40% more response reduction than the TMD.

  • PDF

비탄성 설계스펙트럼을 이용한 소성감쇠기의 적정 크기 산정 (Calculation of Optimum Size of Hysterestic Dampers Using Inelastic Design Spectrum)

  • 최현훈;김유경;김진구
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.406-413
    • /
    • 2001
  • The energy dissipation or damage prevention capability of structure can be greatly enhanced by employing hysteretic dampers. According to recent studies by the authors, the ratio of hysteretic damper stiffness to structural story stiffness has been identified as one of the most important parameters for characterizing the performance of this damper In this study the method for determining appropriate properties of hysteretic dampers to satisfy the given performance objectives is developed based on the concept of capacity spectrum method. The comparison with the results from inelastic time history analysis proves that the hysteretic dampers designed from the proposed method restrains the displacement well within the target displacement.

  • PDF

Health monitoring of a new hysteretic damper subjected to earthquakes on a shaking table

  • Romo, L.;Benavent-Climent, A.;Morillas, L.;Escolano, D.;Gallego, A.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.485-509
    • /
    • 2015
  • This paper presents the experimental results obtained by applying frequency-domain structural health monitoring techniques to assess the damage suffered on a special type of damper called Web Plastifying Damper (WPD). The WPD is a hysteretic type energy dissipator recently developed for the passive control of structures subjected to earthquakes. It consists of several I-section steel segments connected in parallel. The energy is dissipated through plastic deformations of the web of the I-sections, which constitute the dissipative parts of the damper. WPDs were subjected to successive histories of dynamically-imposed cyclic deformations of increasing magnitude with the shaking table of the University of Granada. To assess the damage to the web of the I-section steel segments after each history of loading, a new damage index called Area Index of Damage (AID) was obtained from simple vibration tests. The vibration signals were acquired by means of piezoelectric sensors attached on the I-sections, and non-parametric statistical methods were applied to calculate AID in terms of changes in frequency response functions. The damage index AID was correlated with another energy-based damage index -ID- which past research has proven to accurately characterize the level of mechanical damage. The ID is rooted in the decomposition of the load-displacement curve experienced by the damper into the so-called skeleton and Bauschinger parts. ID predicts the level of damage and the proximity to failure of the damper accurately, but it requires costly instrumentation. The experiments reported in this paper demonstrate a good correlation between AID and ID in a realistic seismic loading scenario consisting of dynamically applied arbitrary cyclic loads. Based on this correlation, it is possible to estimate ID indirectly from the AID, which calls for much simpler and less expensive instrumentation.

Numerical verification of a dual system's seismic response

  • Phocas, Marios C.;Sophocleous, Tonia
    • Earthquakes and Structures
    • /
    • 제3권5호
    • /
    • pp.749-766
    • /
    • 2012
  • Structural control through integration of passive damping devices within the building structure has been increasingly implemented internationally in the last years and has proven to be a most promising strategy for earthquake safety. In the present paper an alternative configuration of an innovative energy dissipation mechanism that consists of slender tension only bracing members with closed loop and a hysteretic damper is investigated in its dynamic behavior. The implementation of the adaptable dual control system, ADCS, in frame structures enables a dual function of the component members, leading to two practically uncoupled systems, i.e., the primary frame, responsible for the normal vertical and horizontal forces and the closed bracing-damper mechanism, for the earthquake forces and the necessary energy dissipation. Three representative international earthquake motions of differing frequency contents, duration and peak ground acceleration have been considered for the numerical verification of the effectiveness and properties of the SDOF systems with the proposed ADCS-configuration. The control mechanism may result in significant energy dissipation, when the geometrical and mechanical properties, i.e., stiffness and yield force of the integrated damper, are predefined. An optimum damper ratio, DR, defined as the ratio of the stiffness to the yield force of the hysteretic damper, is proposed to be used along with the stiffness factor of the damper's- to the primary frame's stiffness, in order for the control mechanism to achieve high energy dissipation and at the same time to prevent any increase of the system's maximum base shear and relative displacements. The results are summarized in a preliminary design methodology for ADCS.

Research on a novel shear lead damper: Experiment study and design method

  • Chong, Rong; Wenkai, Tian;Peng, Wang;Qingxuan, Shi
    • Steel and Composite Structures
    • /
    • 제45권6호
    • /
    • pp.865-876
    • /
    • 2022
  • The slit members have lower strength and lower stiffness, which might lead to lower energy dissipation. In order to improve the seismic performance of the slit members, the paper proposes the shear lead damper, which has stable performance and small deformation energy dissipation capacity. Therefore, the shear lead damper can set in the vertical silts of the slit member to transmit the shear force and improve energy dissipation, which is suitable for the slit member. Initially, the symmetrical teeth-shaped lead damper was tested and analyzed. Then the staggered teeth-shaped lead dampers were developed and analyzed, based on the defect analysis and build improvements of the symmetrical specimen. Based on the parameter analysis, the main influence factors of hysteretic performance are the internal teeth, the steel baffles, and the width and length of damper. Finally, the theoretical analysis was presented on the hysteretic curve. And the skeleton curve and hysteresis path were identified. Based on the above theoretical analysis, the design method was proposed, including the damping force, the hysteresis model and the design recommendations.

Experimental and numerical investigation on the seismic behavior of the sector lead rubber damper

  • Xin Xu;Yun Zhou;Zhang Yan Chen;Song Wang;Ke Jiang
    • Earthquakes and Structures
    • /
    • 제26권3호
    • /
    • pp.203-218
    • /
    • 2024
  • Beam-column joints in the frame structure are at high risk of brittle shear failure which would lead to significant residual deformation and even the collapse of the structure during an earthquake. In order to improve the damage issue and enhance the recoverability of the beam-column joints, a sector lead rubber damper (SLRD) has been developed. The SLRD can increase the bearing capacity and energy dissipation capacity, and also demonstrating recoverability of seismic performance following cyclic loading. In this paper, the hysteretic behavior of SLRD was experimentally investigated in terms of the regular hysteretic behavior, large deformation behavior and fatigue behavior. Furthermore, a parametric analysis was performed to study the influence of the primary design parameters on the hysteretic behavior of SLRD. The results show that SLRD resist the exerted loading through the shear capacity of both rubber parts coupled with the lead cores in the pre-yielding stage of lead cores. In the post-yielding phase, it is only the rubber parts of the SLRD that provide the shear capacity while the lead cores primarily dissipate the energy through shear deformation. The SLRD possesses a robust capacity for large deformation and can sustain hysteretic behavior when subjected to a loading rotation angle of 1/7 (equivalent to 200% shear strain of the rubber component). Furthermore, it demonstrates excellent fatigue resistance, with a degradation of critical behavior indices by no more than 15% in comparison to initial values even after 30 cycles. As for the designing practice of SLRD, it is recommended to adopt the double lead core scheme, along with a rubber material having the lowest possible shear modulus while meeting the desired bearing capacity and a thickness ratio of 0.4 to 0.5 for the thin steel plate.

내진 댐퍼 브레이스를 가진 건축 강구조물의 초기 분재단면 설계 및 내진성능 평가 (The Design of Initial Member Sections and the Evaluation of Seismic Performance for Architectural Steel Structures with Brace Hysteretic Dampers)

  • 이상주;이동우;양재근;한상을
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.619-627
    • /
    • 2005
  • An initial member sections of steel structures is selected by experience of expert building structural designers. And appropriate member section is designed by repeat calculation through structural analysis. Therefore an initial assumption of member section is necessary for saving the time for structural design and is important to acquire safety of building structures. Also brace damper are generally used to prevent or decrease structural damage by its hysteretic behavior in building structures subjected to strong earthquake. Based on plastic design, the initial section of members for architectural steel structures with brace hysteretic dampers is presented and seismic effect of structural behavior by the ratio of damper stiffness to structural story stiffness is estimated in this paper.

  • PDF

이력형 감쇠장치를 이용한 내진보강 예비설계절차 (A Preliminary Design Procedure for Seismic Retrofit Using Hysteretic Dampers)

  • 정국기;유은종
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.59-69
    • /
    • 2022
  • The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.