• Title/Summary/Keyword: hypothetical test

Search Result 217, Processing Time 0.022 seconds

Children's Social Information Processing and Social Behavior in relation to Peer Status (또래지위에 따른 아동의 사회적 정보처리 능력과 사회적 행동 특성)

  • 임연진;이은해
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.1
    • /
    • pp.9-23
    • /
    • 2000
  • This study was designed to test the differences in children's social information-processing patterns and bahavioral characteristics among four different groups of peer status, and to evaluate the predictability of peer status from social information-processing and social behavior. In addition, age and sex differences were assessed. The subjects were 80 boys and 80 girls identified as popular, average, neglected, and rejected by their peers in the first and the third grade. They responded to a sociometric test and three hypothetical social dilemmas, while behavioral characteristics were rated by their teachers. The data were analyzed by ANOVAs, and discriminant analyses. The results showed that children's social information-processing patterns were not significantly different by peer status except the number of interventions requested. Whereas children's behavioral characteristics were different by peer status in all of the four domains. Children's social information-processing patterns and behavioral characteristics were different in part by age and sex. The important predictors of peer status were hyperactive-distractive, anxious-withdrawn, sociable-prosocial behaviors, and the number of interventions requested.

  • PDF

Permutation Analysis of Split-Half Reliability Coefficient

  • Um, Yonghwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.133-139
    • /
    • 2017
  • In this paper, we describe a permutation procedure in which we compute a resampling probability value and empirical quantile limits for Split-Half measure of internal reliability. We use the Split-Half reliability coefficient given by two simple methods, the Spearman-Brown formula and the two-part coefficient alpha. The use of a permutation test for Split-Half reliability coefficient is highlighted as a valuable tool when the sample sizes are small and necessary assumptions cannot be met. The permutation tests for Split-Half reliability coefficient are illustrated with an example analysis of two survey data with a sample size of 15 and 35, respectively, and a hypothetical data with a sample size of 5.

Simulation model-based evaluation of a survey program with reference to risk analysis

  • Chang, Ki-Yoon;Pak, Son-Il
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • A stochastic simulation model incorporated with Reed-Frost approach was derived for evaluating diagnostic performance of a test used for a screening program of an infectious disease. The Reed-Frost model was used to characterize the within-herd spread of the disease using a hypothetical example. Specifically, simulation model was aimed to estimate the number infected animals in an infected herd, in which imperfect serologic tests are performed on samples taken from herds and to illustrate better interpreting survey results at herd-level when uncertainty inevitably exists. From a risk analysis point of view, model output could be appropriate in developing economic impact assessment models requiring probabilistic estimates of herd-level performance in susceptible populations. The authors emphasize the importance of knowing the herd-level diagnostic performance, especially in performing emergency surveys in which immediate control measures should be taken following the survey. In this context this model could be used in evaluating efficacy of a survey program and monitoring infection status in the area concerned.

Accelerated Life Tests under Gamma Stress Distribution (스트레스함수가 감마분포인 가속수명시험)

  • 원영철
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.3
    • /
    • pp.59-66
    • /
    • 2002
  • This paper presents accelerated life tests for Type I censoring data under probabilistic stresses. Probabilistic stress, S, is the random variable for stress influenced by test environments, test equipments, sampling devices and use conditions. The hazard rate, $\theta$ is a random variable of environments and a function of probabilistic stress. In detail, it is assumed that the hazard rate is linear function of the stress, the general stress distribution is a gamma distribution and the life distribution for the given hazard rate, $\theta$is an exponential distribution. Maximum likelihood estimators of model parameters are obtained, and the mean life in use stress condition is estimated. A hypothetical example is given to show its applicability.

GOODNESS-OF-FIT TEST USING LOCAL MAXIMUM LIKELIHOOD POLYNOMIAL ESTIMATOR FOR SPARSE MULTINOMIAL DATA

  • Baek, Jang-Sun
    • Journal of the Korean Statistical Society
    • /
    • v.33 no.3
    • /
    • pp.313-321
    • /
    • 2004
  • We consider the problem of testing cell probabilities in sparse multinomial data. Aerts et al. (2000) presented T=${{\Sigma}_{i=1}}^{k}{[{p_i}^{*}-E{(p_{i}}^{*})]^2$ as a test statistic with the local least square polynomial estimator ${{p}_{i}}^{*}$, and derived its asymptotic distribution. The local least square estimator may produce negative estimates for cell probabilities. The local maximum likelihood polynomial estimator ${{\hat{p}}_{i}}$, however, guarantees positive estimates for cell probabilities and has the same asymptotic performance as the local least square estimator (Baek and Park, 2003). When there are cell probabilities with relatively much different sizes, the same contribution of the difference between the estimator and the hypothetical probability at each cell in their test statistic would not be proper to measure the total goodness-of-fit. We consider a Pearson type of goodness-of-fit test statistic, $T_1={{\Sigma}_{i=1}}^{k}{[{p_i}^{*}-E{(p_{i}}^{*})]^2/p_{i}$ instead, and show it follows an asymptotic normal distribution. Also we investigate the asymptotic normality of $T_2={{\Sigma}_{i=1}}^{k}{[{p_i}^{*}-E{(p_{i}}^{*})]^2/p_{i}$ where the minimum expected cell frequency is very small.

Novel approach to predicting the release probability when applying the MARSSIM statistical test to a survey unit with a specific residual radioactivity distribution based on Monte Carlo simulation

  • Chun, Ga Hyun;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1606-1615
    • /
    • 2022
  • For investigating whether the MARSSIM nonparametric test has sufficient statistical power when a site has a specific contamination distribution before conducting a final status survey (FSS), a novel approach was proposed to predict the release probability of the site. Five distributions were assumed: lognormal distribution, normal distribution, maximum extreme value distribution, minimum extreme value distribution, and uniform distribution. Hypothetical radioactivity populations were generated for each distribution, and Sign tests were performed to predict the release probabilities after extracting samples using Monte Carlo simulations. The designed Type I error (0.01, 0.05, and 0.1) was always satisfied for all distributions, while the designed Type II error (0.01, 0.05, and 0.1) was not always met for the uniform, maximum extreme value, and lognormal distributions. Through detailed analyses for lognormal and normal distributions which are often found for contaminants in actual environmental or soil samples, it was found that a greater statistical power was obtained from survey units with normal distribution than with lognormal distribution. This study is expected to contribute to achieving the designed decision error when the contamination distribution of a survey unit is identified, by predicting whether the survey unit passes the statistical test before undertaking the FSS according to MARSSIM.

Behaviour of geocell reinforced soft clay bed subjected to incremental cyclic loading

  • Hegde, A.;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • v.10 no.4
    • /
    • pp.405-422
    • /
    • 2016
  • The paper deals with the results of the laboratory cyclic plate load tests performed on the reinforced soft clay beds. The performances of the clay bed reinforced with geocells and geocells with additional basal geogrid cases are compared with the performance of the unreinforced clay beds. From the cyclic plate load test results, the coefficient of elastic uniform compression ($C_u$) was calculated for the different cases. The $C_u$ value was found to increase in the presence of geocell reinforcement. The maximum increase in the $C_u$ value was observed in the case of the clay bed reinforced with the combination of geocell and geogrid. In addition, 3 times increase in the strain modulus, 10 times increase in the bearing capacity, 8 times increase in the stiffness and 90% reduction in the settlement was observed in the presence of the geocell and geogrid. Based on the laboratory test results, a hypothetical case of a prototype foundation subjected to cyclic load was analyzed. The results revealed that the natural frequency of the foundation-soil system increases by 4 times and the amplitude of the vibration reduces by 92% in the presence of the geocells and the geogrids.

Test of the New Health Promotion Model for the Prediction of Female Employees' Health Promotion Behavior at the Manufacturing Plants (제조업 여성근로자의 건강증진행위 예측을 위한 새 건강증진 모형의 검증)

  • Yun, Soon-Nyoung
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.3
    • /
    • pp.557-569
    • /
    • 2001
  • The purpose of the study was to test the Pender's New Health Promotion Model in order to explain and predict female workers' health promotion behavior at manufacturing plants by using latent variable structural equation model. The data were collected from 280 female workers at 8 electronic factories located at Seoul. Kyunggi. and Incheon using a structured questionnaire through interview and self-report. LISREL was used to test the model. The results are as follows: 8 out of 15 paths of the modified one from the hypothetical model of Health Promotion were statistically significant and the total variance was 40%. The relationship between the previous health behavior and the cognitive emotional factor, and the interpersonal factor. and the situational factor each. and the relationship between perceived health status and interpersonal factor, and health promotion behavior each among gamma paths were unidirectional. On the beta paths. the relationship between the interpersonal factor and the cognitive emotional factor was bi-directional: the relationships amongst the interpersonal factor and the commitment to action, and the health promotion behavior were unidirectional. But the commitment to action was not a significant mediating factor to the health promotion behavior. Pender's New Model is considered good to explain and predict the female workers' health promotion behavior. The interpersonal factor should be considered in occupational nursing practice. But the concepts of situation and commitment to action should be further validated and measured.

  • PDF

TRIGGERING AND ENERGETICS OF A SINGLE DROP VAPOR EXPLOSION: THE ROLE OF ENTRAPPED NON-CONDENSABLE GASES

  • Hansson, Roberta Concilio
    • Nuclear Engineering and Technology
    • /
    • v.41 no.9
    • /
    • pp.1215-1222
    • /
    • 2009
  • The present work pertains to a research program to study Molten Fuel-Coolant Interactions (MFCI), which may occur in a nuclear power plant during a hypothetical severe accident. Dynamics of the hot liquid (melt) droplet and the volatile liquid (coolant) were investigated in the MISTEE (Micro-Interactions in Steam Explosion Experiments) facility by performing well-controlled, externally triggered, single-droplet experiments, using a high-speed visualization system with synchronized digital cinematography and continuous X-ray radiography. The current study is concerned with the MISTEE-NCG test campaign, in which a considerable amount of non-condensable gases (NCG) are present in the film that enfolds the molten droplet. The SHARP images for the MISTEE-NCG tests were analyzed and special attention was given to the morphology (aspect ratio) and dynamics of the air/ vapor bubble, as well as the melt drop preconditioning. Energetics of the vapor explosion (conversion ratio) were also evaluated. The MISTEE-NCG tests showed two main aspects when compared to the MISTEE test series (without entrapped air). First, analysis showed that the melt preconditioning still strongly depends on the coolant subcooling. Second, in respect to the energetics, the tests consistently showed a reduced conversion ratio compared to that of the MISTEE test series.

Preliminary data analysis of surrogate fuel-loaded road transportation tests under normal conditions of transport

  • JaeHoon Lim;Woo-seok Choi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4030-4048
    • /
    • 2022
  • In this study, road transportation tests were conducted with surrogate fuel assemblies under normal conditions of transport to evaluate the vibration and shock load characteristics of spent nuclear fuel (SNF). The overall test data analysis was conducted based on the measured acceleration and strain data obtained from the speed bump, lane-change, deceleration, obstacle avoidance, and circular tests. Furthermore, representative shock response spectrums and power spectral densities of each test mode were acquired. Amplification or attenuation characteristics were investigated according to the load transfer path. The load attenuated significantly as it transferred from the trailer to the cask. By contrast, the load amplified as it transferred from the cask to the surrogate SNF assembly. The fuel loading location on the cask disk assembly did not exhibit a significant influence on the strain measured from the fuel rods. The principal strain was in the vertical direction, and relatively large strain values were obtained in spans with large spacing between spacer grids. The influence of the lateral location of fuel rods was also investigated. The fuel rods located at the side exhibited relatively large strain values than those located at the center. Based on the strain data obtained from the test results, a hypothetical road transportation scenario was established. A fatigue evaluation of the SNF rod was performed based on this scenario. The evaluation results indicate that no fatigue damage occurred on the fuel rods.