• 제목/요약/키워드: hydrogen vent

검색결과 20건 처리시간 0.022초

가정용 연료전지 시스템 내부의 수소 누출에 관한 전산해석 (A CFD Study on the Hydrogen Leakage for Residential Fuel cell System)

  • 안재욱;정태용;신동훈;남진현;김영규;박주원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2026-2031
    • /
    • 2007
  • Hydrogen is receiving much research attention as an alternative substitute for hydrocarbon fuels these days due to its cleanliness and renewability. However, hydrogen should be used with caution because of its high propensity for leak and wide flammable range. This study deals with a situation that hydrogen leaks and then forms a flammable mixture inside 1kW class residential fuel cell. The residential fuel cell was modeled as a box-shaped chamber with vent openings at the top and bottom, filled with various components such as reformer, desulfurizer, fuel cell stack and humidifier. Computational fluid dynamics (CFD) was used to simulate the diffusion, buoyant flow and accumulation of leaked hydrogen in the modeled chamber. From the simulation, the risk region vulnerable to flame was identified and the methods to minimize such hazardous region was discussed. When the vent openings are 1% of the total surface, as the quantity of hydrogen leakage increases the risk regions increases accordingly. As the vent openings of the total surface increased from 1% to 2.3%, averaged hydrogen mole fraction is under 1% in the system.

  • PDF

급·배기구 면적 변화가 누출 수소 환기에 미치는 영향에 관한 수치해석적 연구 (Numerical Study on the Effect of Area Changes in Air Inlets and Vent Ports on the Ventilation of Leaking Hydrogen)

  • 이창용;조대환
    • 해양환경안전학회지
    • /
    • 제28권2호
    • /
    • pp.385-393
    • /
    • 2022
  • 수소는 지구 온난화의 주범인 온실가스(GHG) 배출을 감소시키고 선박용 친환경 연료로서 대두되고 있다. 수소는 가연 하한계(Lower Flammability Limit, LFL)가 4 ~ 75 %이고 폭발 위험성이 큰 물질이다. 그래서 선박용으로 사용되려면 누출에 대비한 안전성이 충분히 확보되어야 한다. 본 연구에서는 수소탱크 저장실에서 수소 누출이 발생한 경우, 급·배기구의 면적 변화가 환기 성능에 미치는 영향을 분석하였다. 급·배기구의 면적은 1A = 740 mm × 740 mm이며 저장실 표면에 크기 및 위치 변경이 쉽도록 설정하였다. CFD 상용 소프트웨어인 ANSYS CFX ver 18.1을 이용하여 급·배기구의 면적을 1A, 2A, 3A, 5A로 변경하였고, 면적 변화에 따른 저장실 내의 수소 몰분율을 분석하였다. 그 결과 급기구 면적이 배기구 면적 증가에 비해 누출 수소의 농도를 더 감소시켰으며 단일 급기구보다 최소 2A 이상에서 환기 성능이 향상되었다. 급기구의 면적이 증가할수록 수소 층화가 저장실 상부부터 균일하게 형성되었지만 LFL 범위는 벗어나 있었다. 그러나 배기구는 면적을 단순히 증가하는 것만으로는 환기 성능에 미치는 영향은 미비하였다.

가정용 연료전지 시스템 내부 수소 누출의 비정상 및 정상 상태에 관한 전산 해석 (A CFD Study on Unsteady and Steady State of the Hydrogen Leakage for Residential Fuel Cell System)

  • 정태용;안재욱;남진현;신동훈;김영규
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.41-46
    • /
    • 2007
  • 본 연구는 국내 F사의 가정용 연료전지 시스템의 실제 크기를 모델로 하여, 시스템 내부에 4가지 구성품(개질기, 연료전지 스택, 가습기, 탈황기)이 시스템 체적 중 약 30%를 차지하고 있을 때, 환기 면적과 수소 누출량을 변화시키면서 전산 해석을 수행하였다. 환기 면적 1%, 수소 누출량 1%인 경우, 비정상 상태 전산 해석 결과, 수소는 약 50초 후 누출 지점 근처에서 농도 변화를 확연히 감지할 수 있었으며, 200초 후, 시스템 하부에 비해 상부에서 농도 증가를 뚜렷하게 알 수 있었다. 환기 면적 1%, 수소 누출량 1%, 3%, 5%의 대한 정상 상태 해석 결과, 수소 누출량이 5%가 되면 시스템 전 영역에서 수소의 인화 하한(4%, 체적기준)에 도달하는 것을 확인하였다. 환기 면적 2%, 수소 누출량 1%인 경우, 비정상 상태 전산해석 결과, 수소는 약 60초 동안은 누출 지점에서 하부측으로 농도 증가를 보이다가, 점차 상부측 환기구를 통해 배출되어 약 250초가 지난 후 정상 상태에 도달하였다. 환기 면적 2%, 수소 누출량 1%, 3%, 5%의 정상 상태 해석 결과, 수소 누출량이 5%가 되더라도 대부분의 영역에서 경보 농도 수준(1%, 체적기준) 이하임을 확인할 수 있었으나, 누출 지점으로부터 상부쪽으로 위험 영역이 존재함을 알 수 있었다.

  • PDF

수소타운 정압기실 내 수소 누출 특성 연구 (A Study on Characteristics of Hydrogen Leakage in Hydrogen Town Governor Room)

  • 남태호;김동환;이정운;이승국;이연재
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.685-692
    • /
    • 2016
  • Hydrogen will be a future eco-friendly energy source that can replace current fossil fuels However when hydrogen gas leaks and people inhale a lot of hydrogen gases, they can have fatal effects fell into comas. Therefore, we need to develop a safety technology and related guidelines for reducing risks of hydrogen leakage. In this regard, we carried out demonstration tests assuming a situation of hydrogen leakage. Before the experiments, we analyze the standards for governor facilities to check vent positions and sensor positions. Then, we select four types of ventilation structures and proceeds with the experiments of hydrogen leakage at 1 LPM and 1.5 LPM. Based on the experimental results, we propose the direction on optimization of vent positions and sensor positions in the hydrogen leakage situation.

소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 급수배출 및 수소방출 설계 요건 연구 (Investigation on Design Requirements of Feed Water Drain and Hydrogen Vent Systems for the Prototype Generation IV Sodium Cooled Fast Reactor)

  • 박선희;예휘열;이태호
    • Korean Chemical Engineering Research
    • /
    • 제55권2호
    • /
    • pp.170-179
    • /
    • 2017
  • 본 논문은 소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 급수배출부와 수소방출부의 설계요건 도출을 목적으로 한다. 증기발생기 전열관 누설에 의한 소듐-물 반응 발생 시, 증기발생기 내의 급수 증기를 신속하게 배출하는 조건을 도출하기 위해 급수덤프탱크 가스방출배관의 단면적과 증기발생기 급수배출배관의 수직길이를 변화시켜 연구를 수행하였다. 정상운전과 재장전운전에 대해 각각 계산을 수행하여 급수덤프탱크 가스방출배관의 단면적과 증기발생기 급수배출배관의 수직길이를 결정하였다. 정상운전 조건에서 소듐-물 반응 발생 시, 생성물인 수소에 의해 형성되는 과압이 소듐덤프탱크의 설계압력을 만족시킬 수 있도록 하는 가스방출배관의 직경을 도출하였고, 이 때 대기로 방출되는 수소의 유량과 농도를 계산하였다. 본 논문의 계산결과는 향후 소듐냉각고속로 원형로의 소듐-물 반응 압력완화계통의 설계요건으로 활용될 예정이다.

액화수소 충전스테이션에서 VCE로 인한 피해영향평가에 관한 연구 (A Study on the Evaluations of Damage Impact due to VCE in Liquid Hydrogen Charging Station)

  • 이수지;천영우;이익모;황용우
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.56-63
    • /
    • 2017
  • 전세계적으로 수소 충전 스테이션 구축에 많은 투자와 지원을 하고 있는 실정이다. 그러나 수소는 폭발범위가 넓고 확산이 빠른 기체이다. 본 연구에서는 액화수소를 취급하는 소규모~대규모 충전스테이션을 대상으로, 사고시 발생하는 VCE로 인한 피해영향범위를 산출하고, 프로빗 모델을 통해 주변의 인적, 물적 피해를 예측하였다. 더불어, 벤트스택 끝단에서 발생 가능한 Jet fire를 시나리오로 선정하여 최적 높이를 설정하였다. 피해영향범위는 관심과압 6.9kPa을 기준으로 하여, 소규모 저장시설의 경우 8.24m, 중규모 14.10m, 대규모 22.38m이다. 폐출혈로 인한 인체 피해는 소규모와 중규모가 각각 50m, 대규모 100m였으며, 구조물 손상에 따른 피해는 소규모 200m, 중규모 300m 및 대규모 500m이다. 벤트스택의 최적높이는 소규모 4.7m, 중규모 8.8m 및 대규모 16.9m이다.

CFD 툴을 활용한 패키지형 수소충전시스템의 안전성 향상 연구 (A Study on the Safety Improvement by CFD Analysis for Packaged Type Hydrogen Refueling System)

  • 황순일;강승규;허윤실
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.243-250
    • /
    • 2019
  • In this study, to ensure the safety of the packaged hydrogen refueling system, the improvement plan was derived by using 3-dimensional CFD program (FLACS). We also confirmed the effectiveness of risk reduction and the suitability of safety standard. By ventilation performance evaluation according to the position of the vent, it demonstrated that the vent should be installed at the ceiling to safely ventilate without stagnation of the leaked gas. In case of ventilation system according to KGS standard, risk situation could be resolved after about 5 minutes in the worst leaked condition. The result showed that jet fire and explosion inside the packaged system could affect the surrounding facilities. This proves that the standard for installing flame detectors, emergency shut down system and protection wall is appropriate.

Isolation and Characterization of an Extremely Thermophilic Sulfur-metabolizing Bacterium from a Deep-sea Hydrothermal Vent System

  • Kwak, Yi-Seong;Kobayashi, Tetsuo;Akiba, Teruhiko;Horikoshi, Koki;Kim, Young-Bae
    • Journal of Microbiology and Biotechnology
    • /
    • 제4권1호
    • /
    • pp.36-40
    • /
    • 1994
  • A water sample was taken from a black smoker chimney of a deep-sea hydrothermal vent by using an unmanned submersible "Dolphin 3K". The temperature of the hydrothermal fluid from the black smoker was $276^{\circ}C$. After isolation by repeated serial dilutions, An extremely thermophilic bacterial strain was selected. The strain designated as DT1331, was an anaerobic, non-motile, coccoid shaped bacterium with about 0.5 to $1.0\;\mu\textrm{m}$ in diameter. The strain DT1331 could grow up to $93^{\circ}C$, but the optimum temperature of this strain was $80^{\circ}C$. The growth occurred in the pH range of 4.5 to 8.5 and the optimum pH was 6.0. The strain DT1331 required 1% to 5% NaCl for growth and cell lysis was observed below 1% NaCl concentration. The bacterium could grow on polypeptides such as tryptone, peptone, soytone and on proteins such as casein or gelatin. However, no growth was observed on single amino acids, sugar and organic acids. Hydrogen gas was detected slightly during growth. This bacterium obligately required elemental sulfur and hydrogen sulfide gas was produced during growth.

  • PDF

고체연료 매체순환연소기를 위한 회재분리기에서 분리속도 및 분리효율에 미치는 조업변수들의 영향 (Effects of Operating Variables on Separation Rate and Separation Efficiency in Ash Separator for Solid Fuel Chemical Looping Combustor)

  • 류호정;이동호;윤주영;장명수;배달희;박재현;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제27권2호
    • /
    • pp.211-219
    • /
    • 2016
  • To develop an ash separator for the solid fuel chemical looping combustion system, effects of operating variables such as solid injection nozzle velocity, diameter of solid injection nozzle, gap between solid injection line and vent line, vent line inside diameter, and solid intake height on solid separation rate and solid separation efficiency were measured and discussed using heavy and coarse particle and light and fine particles mixture as bed material in an acrylic fluidized bed apparatus. The solid separation rate increased as the solid injection nozzle velocity and the diameter of solid injection nozzle increased. However, the solid separation rate decreased as the gap between solid injection line and vent line, the vent line inside diameter, and the solid intake height increased. The solid separation efficiency was in inverse proportion to the solid separation rate. In this study, we could get high solid separation rate up to 2.39 kg/hr with 91.6% of solid separation efficiency.

건물용 연료전지 복합배기구조 안전 실증평가 (An Empirical Evaluation of Safety of the Common Vent Structure for Stationary Fuel Cell Systems)

  • 이은경;이정운;문종삼;이성희;신동훈
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.596-605
    • /
    • 2018
  • Interest in hydrogen, as an energy carrier, has been growing to solve the problems on shortage of fossile fuels and greenhouse gas. According to the standard KGS FU 551 for stationary fuel cell installation, the fuel cell system could be connected up to two common exhausts to one floor. depending on the required power for building or the installation environment in buildings, multiple fuel cell systems could be installed. Afterwards the number of perforations and flues could be decided. Hence, economic efficiency in significantly determined with respect to installation area and the number of fuel cell systems. In addition, the complexity of common vent structure for stationary fuel cell systems could be changed. In this paper, Verification experiments were conducted by connecting the common exhaust system to the fuel cell simulation system and the actual fuel cell system. Humidity and temperature were changed at ON/OFF, but no factors were found to affect performance or system malfunction. Exhaust emissions were also measured to obtain optimized values. We intend to expand the diffusion of stationary fuel cells by verifying safety of common exhaust structure.