• 제목/요약/키워드: hydrogen sulfide removal

검색결과 157건 처리시간 0.094초

Removal of Hydrogen Sulfide and Methylmercaptan Using Thiobacillus in a Three Phase Fluidized Bed Bioreactor

  • KIM, KYUNG-RAN;KWANG-JOONG OH;KYUNG-YONG PARK;DONGUK KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권3호
    • /
    • pp.265-270
    • /
    • 1999
  • A three phase fluidized bed bioreactor immobilized with Thiobacillus sp. IW was tested to remove hydrogen sulfide and methylmercaptan with high loading rate. In a single gas treatment, the bioreactor removed 92- 98% of hydrogen sulfide with loading rate of 15- 66 g/l/h and removed 87-98% of methylmercaptan with loading rate of 14-60 gl/sup -1/h/sup -1/. In the mixed gas treatment, the removal efficiencies of hydrogen sulfide and methylmercaptan maintained at 89-99% for various inlet loading rates and were not affected by the inlet loading ratio of both gases in low loading rates. When the inlet concentration of methylmercaptan increased 3.8 times and was maintained for 30 h to observe the response of the bioreactor to sudden environmental change, the removal efficiency of methylmercaptan was maintained at an average of 91%.

  • PDF

Utilization of biofilter/photo-catalytic reactor system for the simultaneous treatment of hydrogen sulfide and toluene from waste-air

  • Lim, Kwang-Hee;Ping, Wang Zhi;Lim, Dong-Joon;Lee, Eun-Ju
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.287-292
    • /
    • 2005
  • Hybrid시스템의 운전결과 황화수소의 removal efficiency는 황화수소의 inlet load가 $200g/m^{3}/h$에서 removal efficiency가 급격히 감소하여 약 60%의 수준을 유지하였다. 또한 톨루엔에 대한 removal efficiency는 거의 100%를 유지하다가 톨루엔의 inlet load가 $644g/m^{3}/h$로 증가할 때에는 약 60%로 감소하였다. 이와 같은 Hybrid시스템 운전결과로 부터 바이오필터만을 이용하여 황화수소와 톨루엔을 동시처리할 때보다 removal efficiency가 제고되었음이 관찰되었다.

  • PDF

황화수소와 암모니아를 함유한 악취폐가스의 세미파일럿 규모 바이오필터 처리: 2. 분리 미생물들을 접종한 담체를 충전한 바이오필터 운전 (Semi-pilot Scaled Biofilter Treatment of Malodorous Waste Air Containing Hydrogen Sulfide and Ammonia: 2. Performance of Biofilter Packed with Media Inoculated with a Consortium of Separated Microbes)

  • 임광희
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.240-246
    • /
    • 2014
  • 황화수소와 암모니아를 포함한 악취폐가스를 처리하기 위하여 여러 semi-pilot 바이오필터 운전 조건 하에서 Bacillus cereus DAH-1056과 Arthrobacter sp. KDE-0311를 고정한 semi-pilot 바이오필터 시스템을 운전하였다. Semi-pilot 바이오필터 운전조건에서 Thiobacillus sp. IW와 반송슬러지를 고정한 바이오필터의 황화수소 removal efficiency는 약 80%이었고 암모니아의 removal efficiency는 약 50% 정도이었던 반면에 Bacillus cereus DAH-1056과 Arthrobacter sp. KDE-0311를 고정한 본 연구에서 황화수소의 removal efficiency는 약 90%이었고 암모니아의 removal efficiency는 약 60% 정도이었다. 따라서 본 연구에서 Thiobacillus sp. IW와 반송슬러지를 고정한 semi-pilot 바이오필터의 경우를 기준으로 황화수소 및 암모니아의 removal efficiency가 각각 약 13% 및 20% 정도 제고되었다. 또한 본 연구에서는 암모니아의 최대 elimination capacity가 약 $35g/m^3/h$로서 Thiobacillus sp. IW와 반송슬러지를 고정한 semi-pilot 바이오필터의 경우보다 $3{\sim}5g/m^3/h$ 정도 제고되어 10~17% 더욱 높았다. 한편 본 연구의 황화수소의 최대 elimination capacity는 약 $63g/m^3/h$ 정도로 약 15% 증가하였다. 본 연구에서는 같은 inlet load의 황화수소라 할지라도 높은 농도의 황화수소가 낮은 농도의 황화수소보다 바이오필터의 암모니아 처리를 더 어렵게 하거나, 같은 inlet load의 암모니아라 할지라도 낮은 농도의 암모니아의 경우가 높은 농도의 암모니아보다 더 큰 removal efficiency와 elimination capacity를 갖는 것이 관찰되었다. 본 연구에서의 황화수소 최대처리용량은 황화수소와 암모니아를 동시처리 하였음에도 불구하고 황화수소만을 바이오필터로 처리한 선행연구에서의 황화수소 최대처리용량을 초과하거나 비슷하였다. 또한 본 연구에서는 바이오필터로 황화수소와 암모니아를 동시처리한 선행연구보다 더 높은 암모니아 제거용량을 보였다.

Hydrogen Sulfide Removal by Immobilized Thiobacillus novellas on $SiO_2$ in a Fluidized Bed Reactor

  • Cha, Jin-Myung;Shin, Hyun-Jae;Roh, Sung-Hee;Kim, Sun-Il
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권2호
    • /
    • pp.320-324
    • /
    • 2007
  • The removal of hydrogen sulfide ($H_2S$) from aqueous media was investigated using Thiobacillus novellas cells immobilized on a $SiO_2$ carrier (biosand). The optimal growth conditions for the bacterial strain were $30^{\circ}C$ and initial pH of 7.0. The main product of hydrogen sulfide oxidation by T. novellus was identified as the sulfate ion. A removal efficiency of 98% was maintained in the three-phase fluidized-bed reactor, whereas the efficiency was reduced to 90% for the two-phase fluidized-bed reactor and 68% for the two-phase reactor without cells. The maximum gas removal capacity for the system was 254 g $H_2S/m^3/h$ when the inlet $H_2S$ loading was $300g/m^3/h(1,500ppm)$. Stable operation of the immobilized reactor was possible for 20 days with the inlet $H_2S$ concentration held to 1,100 ppm. The fluidized bed bioreactor appeared to be an effective means for controlling hydrogen sulfide emissions.

고온석탄가스에서 황화물을 제거하기 위한 다공성 흡착제의 개발 -II. 산화아연의 황화반응에 관한 연구- (Development of Porous Sorbents for Removal of Hydrogen Sulfide from Hot Coal Gas -II. Kinetics of Suffidation on Zinc Oxide -)

  • 서인식;이재복;류경옥
    • 한국환경보건학회지
    • /
    • 제14권1호
    • /
    • pp.11-22
    • /
    • 1988
  • Calcium oxide, lithium oxide and titanium oxide were investigated as additives of zinc oxide for the removal of hydrogen sulfide at high temperature. This experiment was performed in the range of 1.0-2.0 vol.% H$_2$S concentration at 623-873 K reaction temperature, using a thermogravimetric analyzer. A pore blocking model was found to fit the reaction rate and the kinetics data were sucessfully expressed by this model. The reactions between additive sorbents and hydrogen sulfide were first order with respect to hydrogen sulfide concentration in a gaseous mixture with nitrogen. Among the used sorbents, ZnO-CaO 0.5 at.% and ZnO-TiO$_2$ 2.0 at.% sorbents had the best additive effects on the sulfidation reaction between additive sorbents and hydrogen sulfide, whereas the ZnO-Li$_2$O sorbents were ineffective.

  • PDF

Bioscrubber와 Biofilter 병합 시스템에 의한 H2S 제거특성 ([ H2S ] Removal Characteristics by Combined System of Bioscrubber and Biofilter)

  • 빈정인;이병헌;감상규;이민규
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.763-769
    • /
    • 2007
  • This study compared the performance of a bioscrubber, a biofilter, and a combined system of bioscrubber and biofilter employed being operated at the laboratory-scale. for the removal of hydrogen sulfide. The bioscrubber maintained 100% removal of hydrogen sulfide up to inlet load of $56\;g-S/m^3{\cdot}hr$, while the removal efficiency was decreased with the increase of inlet load. The biofilter showed 100% removal efficiency up to inlet load of $126\;g-S/m^3{\cdot}h$ and the maximum elimination capacity of $126\;g\;S/m^3{\cdot}h$ for the inlet load of $224\;g-S/m^3{\cdot}h$. On the other hand, the combined system of bioscrubber and biofilter showed 100% removal for an inlet hydrogen sulfide load of up to $85\;g-S/m^3{\cdot}h$ and the maximum elimination capacity of $153\;g-S/m^3{\cdot}h$ for inlet loads of $224\;g-S/m^3{\cdot}h$.

악취폐가스의 세미파일럿 규모 하이브리드 공정 처리: Thiobacillus sp. IW 및 반송슬러지를 접종한 담체를 충전한 바이오필터와 광촉매반응기로 구성된 하이브리드시스템의 운전 (Semi-pilot Scaled Hybrid Process Treatment of Malodorous Waste Air: Performance of Hybrid System Composed of Biofilter Packed with Media Inoculated with Thiobacillus sp. IW and Return-sludge and Photocatalytic Reactor)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.191-198
    • /
    • 2014
  • 퇴비공장 또는 공공시설에서 발생되는 악취폐가스의 대표적인 제거대상 오염원인 황화수소와 암모니아를 포함한 악취폐가스를 처리하기 위하여 여러 운전 조건 하에서 바이오필터와 광촉매반응기로 구성된 semi-pilot 하이브리드시스템을 운전하였다. 황화수소 및 암모니아를 동시 처리하는 바이오필터시스템에서는 황화수소의 처리성능과 다르게 암모니아의 처리성능은 암모니아만을 처리하는 바이오필터시스템보다 훨씬 떨어졌다. Semi-pilot 하이브리드시스템의 황화수소와 암모니아에 대한 제거효율은 각각 약 83% 및 약 65% 정도이었다. 따라서 semi-pilot 바이오필터시스템의 경우보다 황화수소 및 암모니아에 대한 제거효율은 각각 4 및 30% 정도 증가하였다. 또한 황화수소와 암모니아의 동시제거를 할 때에 황화수소와 암모니아의 최대 제거용량은 각각 약 60 및 $37g/m^3/h$이었다. 따라서 semi-pilot 바이오필터시스템의 경우보다 황화수소 및 암모니아에 대한 최대 제거용량은 각각 약 9.1%와 약 23.3% 증가하였다. 그러므로 본 semi-pilot 하이브리드시스템은 semi-pilot 바이오필터시스템을 기준으로 황화수소보다 암모니아의 제거율과 최대 제거용량 제고에 더욱 기여하였다.

플라이애쉬를 이용하여 제조된 인공정량골재를 이용한 황화수소의 제거 연구 (Removal of Hydrogen Sulfide Using Porous Artificial Aggregates Made by Coal Fly-Ash)

  • 김낙주;조호영;김석구;강성원;민수홍;이태윤
    • 대한환경공학회지
    • /
    • 제28권4호
    • /
    • pp.407-413
    • /
    • 2006
  • 본 연구에서는 산업폐기물인 플라이애쉬를 이용하여 악취물질인 황화수소를 효과적으로 제거하기 위해 입자형태로 제조하여 다양한 실험조건 하에서 제거효과를 관찰하였다. 입자형태로 제조하기 위한 최적조건을 선정하기 위해 플라이애쉬 함량, 시멘트 함량, 함수비, 발포제의 양을 변화시켜 공시체를 제조하였으며, 각 공시체에 대해 비중, 흡수율, 압축강도의 값을 측정하였다. 이들 측정값과 실험 시 편의사항을 고려하여 악취제거 실험에 사용될 시료를 선정하였으며, 회분식 및 컬럼실험을 통해 황화수소의 제거양상을 측정하였다. 본 연구조건 하에서의 황화수소 제거율은 사용된 플라이애쉬 입자의 양과 정비례의 관계를 보여주었으며, 수분 첨가 시 황화수소 제거율이 증가하는 것을 확인하였다.

황화수소와 암모니아를 함유한 악취폐가스의 세미파일럿 규모 바이오필터 처리: 1. Thiobacillus sp. IW 및 반송슬러지를 고정한 담체를 충전한 바이오필터 운전 (Semi-pilot Scaled Biofilter Treatment of Malodorous Waste Air Containing Hydrogen Sulfide and Ammonia: 1. Performance of Biofilter Packed with Media with Immobilized Thiobacillus sp. IW and Return-sludge)

  • 이은주;박혜리;임광희
    • Korean Chemical Engineering Research
    • /
    • 제51권5호
    • /
    • pp.568-574
    • /
    • 2013
  • 퇴비공장 또는 공공시설에서 발생되는 악취폐가스의 대표적인 제거대상 오염원인 황화수소와 암모니아를 포함한 악취폐가스를 처리하기 위하여 여러 운전 조건 하에서의 Thiobacillus sp. IW 및 반송슬러지를 고정한 담체를 충전한 semi-pilot 바이오필터 시스템을 운전하였다. Semi-pilot 바이오필터 운전 초반 및 중반에서는 황화수소 제거효율은 암모니아 부하와 무관하였으나, 암모니아 제거효율은 황화수소 부하가 커짐에 따라서 감소하였다. 그럼에도 불구하고 semi-pilot 바이오필터 운전 후반에서는 황화수소 부하가 커짐에도 불구하고 암모니아 제거효율이 영향을 받지 않았다. 이것은 semi-pilot 바이오필터 운전 후반의 buffer solution의 지속적 투입으로 인하여 semi-pilot 바이오필터담체의 산성화가 크지 않음에 기인한다고 간주된다. Semi-pilot 바이오필터시스템으로 황화수소와 암모니아의 동시제거를 할 때에 황화수소와 암모니아의 최대 elimination capacity 값은 각각 약 58 및 $30g/m^3/h$이었다. 이와 같이 semi-pilot 바이오필터 운전에 의하여 황화수소와 암모니아를 동시 제거한 경우에는 실험실규모 바이오필터의 유사한 운전조건 하에서 둘 중의 하나만을 함유한 경우보다 제거용량이 각각 약 39와 46% 만큼 감소하여서, 황화수소와 암모니아를 동시 제거한 경우에 암모니아 최대제거용량이 황화수소 최대제거용량보다 7% 만큼 더 감소하였다.

환경기초시설에서 발생하는 악취가스 제거에 관한 연구 (The Study on the Removal of Odor Emitting Environmental Fundamental Facility)

  • 이병관;이상훈;탁성제;이병기
    • 한국기후변화학회지
    • /
    • 제8권1호
    • /
    • pp.51-56
    • /
    • 2017
  • The objective of the research project is to develop the hybrid deodorizer for the removal of residual harmful gases generating during pretreatment process of biogas. This hybrid deodorizer is capable of treating harmful gases that contains hydrogen sulfide ($H_2S$), ammonia ($NH_3$) and other odor substances. This hybrid deodorizer reduced the hydrogen sulfide content from approximately 150~200 ppm to less than 16 ppm. These residual harmful gases were effectively removed in the effluent, achieving up to 97% removal of $H_2S$ and 94% removal of $NH_3$ after treatment using hybrid deodorizer.