• Title/Summary/Keyword: hydrogen permeation

Search Result 130, Processing Time 0.025 seconds

The Characteristics of Hydrogen Permeation through Pd-coated $Nb_{56}Ti_{23}Ni_{21}$ Alloy Membranes (Pd 코팅된 $Nb_{56}Ti_{23}Ni_{21}$ 합금 분리막의 수소투과 특성)

  • Jung, Yeong-Min;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • We make a studyof the hydrogen permeability and chemical stability of $Nb_{56}Ti_{23}Ni_{21}$ metal alloy membrane. For this purpose, we produced the $Nb_{56}Ti_{23}Ni_{21}$ membrane which has 10 mm diameter and 0.5 mm thick, and experiment the hydrogen transport properties under two kinds of feed gas ($H_2$ 100%; $H_2$ 60% + $CO_2$ 40%) at $450^{\circ}C$C with variation of absolute pressure.The maximum hydrogen permeation flux was $5.58mL/min/cm^2$ in the absolute pressure 3 bar under pure hydrogen. And each case of feed gases about gas composition, the permeation fluxes were satisfied with Sievert's law, and the hydrogen permeation flux decreased with decrease of hydrogen partial pressure irrespective of temperature and pressure. After permeation test, we experiment the stability and durability of $Nb_{56}Ti_{23}Ni_{21}$ alloy membrane for carbon dioxide by XRD analysis.

Effects of Nickel Supports on Hydrogen Permeability of Vanadium based Membrane (니켈 지지체를 이용한 바나듐기 분리막의 수소 투과특성)

  • Cho, Kyoungwon;Choi, Jaeha;Jung, Seok;Kim, Raymundk.I.;Hong, Taewhan;Ahn, Joongwoo
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.3
    • /
    • pp.200-205
    • /
    • 2013
  • The separation of hydrogen depends on porosity, diffusivity and solubility in permeation membrane. Dense membrane is always showing a solution diffusion mechanism but porous membrane is not showing. Therefore, porous membrane has a good hydrogen flux due to pore is carried out transferred media. This mechanism is named as the Knudsen diffusion. Hydrogen molecules or hydrogen atoms are diffused along pore that is a mean free path. In this study, complex layer hydrogen permeation membrane was fabricated by hot press process. And then, it was evaluated and calculated to relationship between hydrogen permeability and membrane porosity.

Hydrogen Separation by Compact-type Silica Membrane Process (컴팩트 타입 실리카막 공정을 이용한 수소 분리)

  • Moon, Jong-Ho;Bae, Ji-Han;Lee, Sang-Jin;Chung, Jong-Tae;Lee, Chang-Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.336-339
    • /
    • 2006
  • With the steady depletion off fossil fuel reserves, hydrogen based energy sources become increasingly attractive. Therefore hydrogen production or separation technologies, such as Bas separation membrane based on adsorption technology, have received enormous attention in the industrial and academic fields. In this study, the transport mechanisms of the MTES (methyltriethoxysilane) templating silica/a-alumina composite membrane were evaluated by using unary, binary and quaternary hydrogen gas mixtures permeation experiments at unsteady- and steady-states. Since the permeation flux in the MTES membrane, through the experimental and theoretical study, was affected by molecular sieving effects as well as surface diffusion properties, the kinetic and equilibrium separation should be considered simultaneously in the membrane according to molecular properties. In order to depict the transient multi-component permeation on the templating silica membrane, the GMS (generalized Maxwell-Stefan) and DGM (dust Bas model) were adapted to unsteady-state material balance

  • PDF

Fabrication and Hydrogen Permeation Properties of $V_{99.8}B_{0.2}$ Alloy Membrane for Hydrogen Separation (수소 분리를 위한 $V_{99.8}B_{0.2}$ 분리막의 제조와 수소투과특성)

  • Jung, Yeong-Min;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.21 no.4
    • /
    • pp.345-350
    • /
    • 2011
  • No investigation has yet been accomplished to screen the boron-doped effects on vanadium based metal membranes. The synthesis, hydrogen permeation properties and chemical stability of a novel Pd-coated $V_{99.8}B_{0.2}$ alloy membrane are presented in this report. Hydrogen permeation experiments have been performed to investigate the hydrogen transport properties through the Pd-coated $V_{99.8}B_{0.2}$ alloy membrane in the absolute pressure range 1.0~3.0 bar under pure hydrogen, hydrogen-carbon dioxide gas mixture at $400^{\circ}C$. The maximum hydrogen permeation flux was $48.5mL/min/cm^2$ for a 0.5 mm thick membrane under pure hydrogen. This results offer new direction in the synthesis of novel non-Palladium-based metal membranes for hydrogen separation in water-gas shift reaction.

SAFETY STUDIES ON HYDROGEN PRODUCTION SYSTEM WITH A HIGH TEMPERATURE GAS-COOLED REACTOR

  • TAKEDA TETSUAKI
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.537-556
    • /
    • 2005
  • A primary-pipe rupture accident is one of the design-basis accidents of a High-Temperature Gas-cooled Reactor (HTGR). When the primary-pipe rupture accident occurs, air is expected to enter the reactor core from the breach and oxidize in-core graphite structures. This paper describes an experiment and analysis of the air ingress phenomena and the method fur the prevention of air ingress into the reactor during the primary-pipe rupture accident. The numerical results are in good agreement with the experimental ones regarding the density of the gas mixture, the concentration of each gas species produced by the graphite oxidation reaction and the onset time of the natural circulation of air. A hydrogen production system connected to the High-Temperature Engineering Test Reactor (HTTR) Is being designed to be able to produce hydrogen by themo-chemical iodine-Sulfur process, using a nuclear heat of 10 MW supplied by the HTTR. The HTTR hydrogen production system is first connected to a nuclear reactor in the world; hence a permeation test of hydrogen isotopes through heat exchanger is carried out to obtain detailed data for safety review and development of analytical codes. This paper also describes an overview of the hydrogen permeation test and permeability of hydrogen and deuterium of Hastelloy XR.

Hydrogen Permeation of SiC-CeO2 Composite Membrane by Dip-coating Process

  • Park, Jihye;Jung, Miewon
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.485-488
    • /
    • 2013
  • A SiC-$CeO_2$ composite membrane was successfully fabricated using an ally-hydridopolycarbosilane (AHPCS) binder and treated by dip-coating at 60 times with a $CeO_2$ sol solution. The dip-coated SiC membrane was calcined at 773 K and then sintered at 1173 K under an air atmosphere. The coated membrane was characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM) and a BET surface analysis. The difference in permeation performance between $H_2$ and CO gases was measured by varying the temperature. The permeation flux of $H_2$ on the SiC membrane with layered $CeO_2$ was obtained as $8.45{\times}10^{-6}\;mol/m^2sPa$ at room temperature. The CO permeation flux was $2.64{\times}10^{-6}\;mol/m^2sPa$ at room temperature. The reaction enthalpy (${\Delta}H^{\circ}$) for the hydrogen permeation process was calculated as -7.82 J/mol by Arrhenius plots.

Hydrogen Permeation Properties of $(Ni_{60}-Nb_{40})_{95}-Pd_5$ Amorphous Metallic Membrane ($(Ni_{60}-Nb_{40})_{95}-Pd_5$ 비정질 금속막의 수소투과 특성)

  • Lee, Dock-Young;Kim, Yoon-Bae
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.4
    • /
    • pp.359-366
    • /
    • 2008
  • Hydrogen as a high-quality and clean energy carrier has attracted renewed and ever-increasing attention around the world in recent years, mainly due to developments in fuel cells and environmental pressures including climate change issues. In this processes for hydrogen production from fossil fuels, separation and purification is a critical technology. $(Ni_{60}-Nb_{40})_{95}-Pd_5$ alloy ingots were prepared by arc-melting the mixture of pure metals in an Ar atmosphere. Melt-spun ribbons were produced by the single-roller melt-spinning technique in an Ar atmosphere. Amorphous structure and thermal behavior were characterized by XRD and DSC. The permeability of the $(Ni_{60}-Nb_{40})_{95}-Pd_5$ amorphous alloy membrane was characterized by hydrogen permeation experiments in the temperature range 623 to 773 K and pressure of 2 bars. The maximum hydrogen permeability was $3.54{\times}10^{-9}[mol{\cdot}m^{-1}s^{-1}{\cdot}pa^{-1/2}]$ at 773 K for the $(Ni_{60}-Nb_{40})_{95}-Pd_5$ amorphous alloy.

Effect of Lateral Diffusion on Hydrogen Permeation Measurement in Thick Steel Specimens

  • Traidia, A.;El-Sherik, A.M.;Attar, H.;Enezi, A.
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.201-208
    • /
    • 2017
  • A finite element analysis is proposed to study the effect of specimen dimensions on lateral diffusion of hydrogen during hydrogen permeation flux measurements. The error of measurement on thick specimens because of 1D diffusion approximation may be as much as 70%. A critical condition for accurate measurements is to designate the area of hydrogen monitoring/exit surface smaller than the area of hydrogen charging/entry surface. For thin to medium thickness specimens (ratio of thickness to specimen radius of 5:10 and below), the charging surface should be maximized and the monitoring surface should be minimized. In case of relatively thick specimens (ratio of thickness to specimen radius above of 5:10), use of a hydrogen-diffusion barrier on the specimen boundaries is recommended. It would completely eliminate lateral losses of hydrogen, but cannot eliminate the deviation towards 2D diffusion near the side edges. In such a case, the charging surface should be maximized and the monitoring surface should be as closer in dimension as the charging surface. A regression analysis was carried out and an analytical relationship between the maximum measurement error and the specimen dimensions is proposed.

A Study on the Palladium Alloy Membrane for Hydrogen Separation (수소 정제용 팔라듐 합금 분리막 연구)

  • Woo, Byung-Il;Kim, Dong-Won
    • Journal of Surface Science and Engineering
    • /
    • v.42 no.5
    • /
    • pp.232-239
    • /
    • 2009
  • This study presented the effect of membrane thickness on hydrogen permeability. Microvoids on the surface of the membrane should not exist for the exact values of hydrogen permeability. Pd-Cu-Ni hydrogen alloy membranes were fabricated by Ni powder sintering, substrate plasma pretreatment, sputtering and Cu reflow process. And this leaded to void-free surface and dense film of Pd-Cu-Ni hydrogen alloy membrane. Hydrogen permeation test showed that hydrogen permeability increased from 2.7 to $15.2ml/cm^2{\cdot}min{\cdot}atm^{0.5}$ as membrane thickness decreased from 12 to $4{\mu}m$. This represented the similar trend as a hydrogen permeability of pure palladium membrane based on solution-diffusion mechanism.