• Title/Summary/Keyword: hydrogen explosion

Search Result 153, Processing Time 0.026 seconds

Measurement of Minimum Ignition Energy by Electrostatic Discharge for Flammable Ternary Gas Mixtures (3성분계 인화성 혼합가스의 최소점화에너지 측정에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • When flammable gases are mixed with air or oxygen in the explosion concentration range and are ignited by sufficiently large electrostatic discharge energy, they may explode causing severe disaster in workplace. The minimum ignition energy(MIE) of single gas-air mixtures has been already investigated by many research, but the MIE of mixtures of more than ternary gas mixture is not examined yet. The purpose of this study is to investigate the MIE of a ternary gas(methane, ethylene, hydrogen, propane) mixtures experimentally. The results of our experiment show that the ignition of a methane-ethylene-air, methane-hydrogen-air, methane-propane-air, ethylene-hydrogen-air, ethylene-propane-air and hydrogen-propane-air mixture due to electrostatic discharge energy primarily depends on that the mixture: the MIE decreases gradually with the increase of having the lower MIE than other mixture ratio in the normal atmospheric pressure.

An Experimental Study on the Transition of Momentum Controlling Hydrogen Jet to Buoyant Jet (운동량제어 수소제트가 부양제트로 천이되는 현상에 대한 실험적 연구)

  • Won, S.H.;Chung, S.H.;Kim, J.S.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Transition of momentum-controlling hydrogen jet to buoyant jet is experimentally investigated in order to develop a prediction model for the moving trajectory of hydrogen leaked from hydrogen devices. In the experiments, room-temperature helium, that has a similar density to the hydrogen leaked from high pressure tank, is horizontally injected through a 4mm tube and its moving trajectory is visualized by the shadowgraph method. The moving trajectories are found to be parabolic, thereby exhibiting increasing influence of the buoyancy. In analyzing the experimental results, the vertical movement is assumed to be controlled by the buoyancy while the horizontal movement is controlled by the air entrainment caused by the initial momentum. The resealing based on this assumption yields a single curve fitting to the all experimental results.

A Study on Influence of Fuel Cell Performance by Hydrogen Odorant (수소가스 부취제가 연료전지의 성능에 미치는 영향 연구)

  • Han, Sang-Won;Oh, Seok-Hwan;Kim, Young-Gyu;Lee, Sung-Hun;Chae, Jae-Ou
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.491-494
    • /
    • 2008
  • The hydrogen fuel and fuel cell which have high energy efficiency and low pollutant emission are getting interest as an alternative energies due to the fossil fuel exhaust, green house effect and atmospheric pollutant problems. The hydrogen gas is very effective as an alternative energy. But, if it is leaked into the air it forms the mixed gas with the air then the danger of the explosion is risen up. So, the secure the safety is mostly important. In this research, to detect the leakage of the hydrogen rapidly, added the odorant materials which don't include the sulfur component into the hydrogen gas and researched on the effect of each odorant on the performance of the fuel cell. As the results, setting the cumulation electric power on the basis and comparing the pure hydrogen, 2,3-Butanedione 5ppm mixed gas 86.1%, 5-Ethylidene-2-Norbornene 17ppm mixed gas 88.2%, Isovaleraldehyde 10ppm mixed gas 74.8%, Ethyl Isobutyrate 2.2ppm mixed gas 93.5% of performance was shown.

  • PDF

A Study on the safety measures for hydrogen cooling system of 500MW class thermal power plant (500MW급 화력발전소 수소냉각시스템의 안전대책)

  • Kim, Soon-Gi;Yuk, Hyun-Dai;Ka, Chool-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.385-390
    • /
    • 2005
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising; 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF

PREDICTION OF HYDROGEN CONCENTRATION IN CONTAINMENT DURING SEVERE ACCIDENTS USING FUZZY NEURAL NETWORK

  • KIM, DONG YEONG;KIM, JU HYUN;YOO, KWAE HWAN;NA, MAN GYUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.2
    • /
    • pp.139-147
    • /
    • 2015
  • Recently, severe accidents in nuclear power plants (NPPs) have become a global concern. The aim of this paper is to predict the hydrogen buildup within containment resulting from severe accidents. The prediction was based on NPPs of an optimized power reactor 1,000. The increase in the hydrogen concentration in severe accidents is one of the major factors that threaten the integrity of the containment. A method using a fuzzy neural network (FNN) was applied to predict the hydrogen concentration in the containment. The FNN model was developed and verified based on simulation data acquired by simulating MAAP4 code for optimized power reactor 1,000. The FNN model is expected to assist operators to prevent a hydrogen explosion in severe accident situations and manage the accident properly because they are able to predict the changes in the trend of hydrogen concentration at the beginning of real accidents by using the developed FNN model.

The Evaluation of Fire Reliability for the High Pressure Hydrogen Storage System of Fuel Cell Vehicle (I) (연료전지자동차의 고압수소저장시스템 국부화재 신뢰성 평가 (I))

  • Kim, Sang-Hyun;Choi, Young-Min;Hang, Ki-Ho;Shim, Ji-Hyun;Hang, In-Cheol;Lim, Tae-Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.520-526
    • /
    • 2011
  • In recent years, it is very important that hydrogen storage system is safe for user in any circumstances in case of crash and fire. Because the hydrogen vehicle usually carry high pressurized cylinders, it is necessary to do safety design for fire. The Global Technical Regulation (GTR) has been enacted for localized and engulfing fire test. High pressure hydrogen storage system of fuel cell electrical vehicles are equipped with Thermal Pressure Relief Device (TPRD) installed in pressured tank cylinder to prevent the explosion of the tank during a fire. TPRDs are safety devices that perceive a fire and release gas in the pressure tank cylinder before it is exploded. In this paper, we observed the localized and engulfing behavior of tank safety, regarding the difference of size and types of the tanks in accordance with GTR.

A Numerical Study on Ventilation Characteristics of Factors Affecting Leakages in Hydrogen Ventilation (누출 수소 환기에 영향을 미치는 요인별 환기 특성에 관한 수치해석적 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.610-619
    • /
    • 2022
  • Hydrogen is emerging as an alternative fuel for eco-friendly ships because it reacts with oxygen to produce electrical energy and only water as a by-product. However, unlike regular fossil fuels, hydrogen has a material with a high risk of explosion due to its low ignition point and high flammability range. In order to safely use hydrogen in ships, it is an essential task to study the flow characteristics of hydrogen leakage and diffusion need to be studied. In this study, a numerical analysis was performed on the effect of leakage, ventilation, etc. on ventilation performance when hydrogen leaks in an enclosed space such as inside a ship. ANSYS CFX ver 18.1, a commercial CFD software, was used for numerical analysis. The leakage rate was changed to 1 q, 2 q, and 3 q at 1 q = 1 g/s, the ventilation rate was changed to 1 Q, 2 Q and 3 Q at 1 Q = 0.91 m/s, and the ventilation method was changed to type I, type II, type III to analyze the ventilation performance was analyzed. As the amount of leakage increased from 1 q to 3 q, the HMF in the storage room was about 2.4 to 3.0 times higher. Furthermore, the amount of ventilation to reduce the risk of explosion should be at least 2 Q, and it was established that type III was the most suitable method for the formation of negative pressure inside the hydrogen tank storage room.

An Experimental Study on the Sensor Response at Hydrogen Leakage in a Residential Fuel Cell System (가정용 연료전지 시스템 내부 수소 누출 시 센서 응답 특성에 관한 연구)

  • Kim, Young-Doo;Shin, Dong-Hoon;Chung, Tae-Yong;Nam, Jin-Hyun;Kim, Young-Gyu;Lee, Jung-Woon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.378-383
    • /
    • 2009
  • Hydrogen is the primary fuel in fuel cell systems. Because of high inflammation and explosion possibility of hydrogen, fuel cell systems require safety measures to prevent hydrogen hazard upon leakage. In this study, a model enclosure was made by referring to a commercial residential fuel cell system and hydrogen leakage experiments and computational simulations were conducted therein. Hydrogen was injected into the cavity through leakage holes located at the bottom while its flow rate was precisely controlled using MFC. The transient sensor signals from hydrogen sensors installed inside the enclosure were recorded and analyzed. The hydrogen sensor signals showed different delay times depending on their position relative to a leakage point, which indicated that hydrogen generally moves upward and accumulates at the upper region of a closed cavity. The inflammable regions with hydrogen concentration over 4% LEL were observed to locate near the leakage hole initially, and broaden towards the upper cavity region afterward. The simulation result showed that detection time at the hydrogen sensor was similar to the pattern of experimental results. However, the maximum concentration of hydrogen had a gap between experiment and simulation at detect point due to measurement errors and reaction rate.

Risk Assessment and Its Application for the POSCO's Batch Annealing Furnace Gas Systems (광양제철소 소둔로 가스설비에 대한 위험성 평가 및 안전성향상안 제시)

  • Kim Y. S.;Yoo J. H.;Jeong S. Y.;Jang E. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.9-13
    • /
    • 2001
  • A complete spectrum of risk assessment including qualitative and quantitative approaches were performed for the POSCO's Batch Annealing Furnace (BAF) gas systems. The purpose of BAF is to enhance the quality of steel by annealing it with either hydrogen/nitrogen mixture gas or pure hydrogen gas. Number of gas leak scenarios were identified to generate frequency of their occurrences. With the hypothetical accident scenarios given, fire/explosion impact studies were performed to estimate magnitude of significant consequences. Several different indices were also presented from which practical safety improvement action items could be established.

  • PDF