A study on the flood runoff analysis with TANK MODEL (탱크 모델에 의한 홍수(洪水) 유출량(流出量) 해석(解析)에 관(關)한 연구(硏究))

  • Hong, Chang-sun;Choi, Han-kuy
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.95-101
    • /
    • 1983
  • This study aims at the determination of the coefficienties of runoff and infiltration affecting runoff. The rating curve is more available than the peak flood runoff to determine flood control plan of flood control reservoir and the volume of hydroelectric power plant, or to make multipurpose dam. In hydrologic analysis and design, it is necessary to develop relations between precipitation and runoff, possible using some of the factors affecting runoff as parameters. In order to calculate the runoff discharge, the runoff process constituting elements are divided to the surface runoff, the subsurface runoff and the groundwater runoff. By comparing the computed hydrograph with the measured hydrograph, determinned the watershed TANK Model constant Varying the tank model constant for approximating the computed hydrograph to the measured hydrograph.

  • PDF

Geophysical investigations for deciding alignment of head race tunnel and location of lake tapping at Koyna hydroelectric project, Maharashtra, India

  • Wadhwa R. S.;Chaudhari M. S.;Chandrasekhar V.;Saha A.;Mukhopadhyay R.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.370-378
    • /
    • 2003
  • Continuous seismic refraction, reflection and echo-sounder surveys conducted at Koyna Project site provided geotechnical information which helped in choosing the alignment for Head race tunnel and in designing and choosing the site for Lake Tap. Seismic refraction survey both on land and in shallow water determined depths to bedrock and helped in inferring the bedrock quality. Seismic reflection survey mapped the subsurface stratigraphy with high resolution. Reservoir-bed and bedrock contours drawn from the results of the survey helped in choosing the tunnel alignment and the lake tap position cost effectively. It was inferred from the results of the survey that the geology and the quality of rock do not change unexpectedly around the site for extension of Head race tunnel and the lake tapping. The bedrock levels evaluated by seismic survey agreed remarkably well with those inferred in boreholes having Rock Quality Designation 90 percent or more.

  • PDF

A Strategy of Generation Portfolio for Stand-Alone Microgrids Based on an Hydroelectric Power System (수력발전 기반의 자립형 마이크로그리드 발전원 구성 전략에 관한 연구)

  • Shin, Yeon-Ji;Woo, Ji-Hyoung;Lee, Hong-Joo;Kim, Sung-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.69-70
    • /
    • 2015
  • 신재생에너지의무할당제의 도입과 신재생에너지 관련 기술의 급속한 발전으로 인해 자립형 마이크로그리드에 대한 관심과 필요성이 증가하고 있다. 이에 본 논문에서는 기존에 비상용 발전기로 활용되고 있던 수력발전과 유휴 수면을 활용한 수상 태양광발전, 신재생에너지의 출력 안정화를 위한 에너지저장장치의 발전 특성을 분석하고, 차세대 수력발전 기반 하이브리드 전력시스템의 발전원 구성안을 제시하고자 한다.

  • PDF

Evaluation of turbulence models in rough-wall boundary layers for hydroelectric applications

  • Dutta, Rabijit;Nicolle, Jonathan;Giroux, Anne-Marie;Piomelli, Ugo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.3
    • /
    • pp.227-239
    • /
    • 2017
  • The accuracy of turbulence models for the Reynolds-Averaged Navier-Stokes (RANS) equations in rough-wall flows is evaluated using data from large-eddy simulations (LES) of boundary layers with favourable and adverse pressure gradients. Some features of the flow (such as flow reversal in the roughness sublayer) cannot be captured accurately by any model, due to the fundamental model formulation. In mild pressure gradients most RANS models are sufficiently accurate for engineering applications, but if strong favourable or adverse pressure gradients are applied (especially those leading to separation) the model performance rapidly degrades.

Development of the Repair Mortar using Coarse Powder of Coal Ash (석탄회 조분을 유효이용한 보수 모르터의 개발)

  • 전진환;조정기;시기영장;립정호;화미광희
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1017-1022
    • /
    • 2003
  • The hydraulic structures such as aqueduct tunnels and the drainage canal of the hydroelectric power plant in Japan are almost old. Therefore, the concrete surface of the aqueduct tunnel has received damage by wear-out and the crack, etc. This study was to develop repair mortar mixed a coal ash coarse powder by using two kinds of high early strength cements. As a result, the repair mortar was obtained by substituting the EF cement (maid in Japan) and the MT cement (maid in South Korea) at a rate of 60:40, and substituting the coal ash 30% and the mixing rate 35% of the artificial aggregate for natural fine aggregate.

  • PDF

A Case Study on the Chungsong Pumped-storage power station Construction (청송 양수발전소 시공사례)

  • Hong, Chang-Soo;Lee, Hyun-Koo;Do, Jong-Youl
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.169-178
    • /
    • 2006
  • The pumped-storage power system is the one of the hydroelectric power systems, generating electricity with hydraulic head difference. In this system, the electricity is produced during the hours of peak demand by using water that has been pumped into an upper reservoir from a lower reservoir during the hours of low demand. Generally, the system consists of an under-ground power house and tunnels such as the headrace, pressure, and tailrace tunnels. The Chungsong pumped-storage power station is the sixth one In the pumped-storage power station in Korea. Both the regional self-government and the population of chungsong -Goon had made a great effort to draw this power station construction into this area. The proposed Chungsong pumped-power station construction project was accepted by the central government as a part of the national electricity plan for the first time in Korea.

  • PDF

The Study on DSA of Intergrated Operating System (통합운영체계의 DSA 적용 연구)

  • Cho, Nam-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2322-2324
    • /
    • 2002
  • Korea Water Resources Corporation (KOWACO) operates nine hydroelectric power stations on the Han River, Nakdong River, Geum River & Seomjin River Areas. KOWACO will take the lead in improving the efficiency of water resources supply in this parer, KOWACO Generation Intergrated Operating System(GIOS) project will improve the generating plant, hydraulic structures, switchgear, and station controls, alarms and services for unmanned remote controlled operation by modern intergraed SCADA system. Mordern SCADA is used to cover all computer systems designed to perform the following main functions: - to collect data from industrial plant devices. - to process and perform calculations on the collected. - to present collected and derived data on displays on. - to accept commands entered by human operators and act on them such as sending control commands to plant devices.

  • PDF

The National Economic Effects of Four Power Generation Sectors: Using an Industrial Linkage Analysis (발전부문별 국민경제적 파급효과 분석 - 산업연관분석을 적용하여 -)

  • Kwa, Seung-Jun;Yoo, Seung-Hoon;Han, Sang-Yong
    • Environmental and Resource Economics Review
    • /
    • v.11 no.4
    • /
    • pp.581-608
    • /
    • 2002
  • The electric power industry has played an important role in dramatic economic development in Korea and the electricity has constituted a critical factor sustaining the well-being of the Korean people. This study uses input-output analysis to investigate the role of four electric power sectors (hydroelectric, fossil-fuels, nuclear and non-utility) in the Korean national economy for the period 1985~1998, focusing on four topics: the impacts of electricity supply investments, the electricity supply shortage effects, and the impacts of the rise in electricity rates, and the inter-industry linkage effect. The overall results reveal that non-utility electric sector is superior in terms of the national economy-wide effects to other three sectors throughout the period. Finally, potential uses of the results are illustrated from the perspective of policy instruments and some policy implications are discussed.

  • PDF

Analysis for the Inrush Current and Voltage Drop of Induction Generator by the Reactor Tap Change (리액터 탭 설정값에 따른 유도발전기의 돌입전류와 전압강하 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1202-1206
    • /
    • 2015
  • The induction generator has many advantages compared to the synchronous generator in terms of cost and maintenance. So squirrel cage induction generator has been recently supplied in small hydroelectric power station. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to increase the supply of the induction generator, it is very important to find the method of reducing inrush current and voltage drop.

Examination of Applicability of Repair Mortar using Very High Early Strength Cement (초속경시멘트를 이용한 보수모르터의 현장적용성 검토)

  • Jeon Jin Hwan;Kasai Hiroshi;Yazaki Hideaki;Cho Chung Ki
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.309-312
    • /
    • 2004
  • The hydraulic structure of the hydroelectric power plant such as aqueduct tunnels and the drainage canal became old. Therefore, because the concrete surface of the aqueduct tunnel has received severe damage by wear-out and the crack etc the repair is demanded. This research examined the applicability of the repair mortar which mixed the fly ash and an artificial aggregate by using the very high early strength cement. As a result, good Quality repair mortar which satisfied the demand performance more than self-flow 270mm and compressive strength $50N/mm^2$ (age of 28days) adjusting of water cement ratio by using the MTX cement be able to be manufactured.