• Title/Summary/Keyword: hydro-mechanical

Search Result 385, Processing Time 0.023 seconds

Design for Landfill Gas Application by Low Calorific Gas Turbine and Green House Optimization Technology (Low Calorific Gasturbine 매립지 적용 및 유리온실 운용기술 설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin;Rhim, Sang-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.244.1-244.1
    • /
    • 2010
  • Bio energy development by using Low Calorific Gas Turbine(LCGT) has been developed for New & Renewable energy source for next generation power system, low fuel and operating cost method by using the renewable energy source in landfill gas (LFG), Food Waste, water waste and Livestock biogas. Low calorific fuel purification by pretreatment system and carbon dioxide fixation by green house system are very important design target for evaluate optimum applications for bio energy. Main problems and accidents of Low Calorific Gas Turbine system was derived from bio fuel condition such as hydro sulfide concentration, siloxane level, moisture concentration and so on. Even if the quality of the bio fuel is not better than natural gas, LCGT system has the various fuel range and environmental friendly power system. The mechanical characterisitics of LCGT system is a high total efficiency (>70%), wide range of output power (30kW - 30MW class) and very clean emmission from power system (low NOx). Also, we can use co-generation system. A green house designed for four different carbon dioxide concentration from ambient air to 2000 ppm by utilizing the exhaust gas and hot water from LCGT system. We look forward to contribute the policy for Renewable Portfolio Standards(RPS) by using LCGT power system.

  • PDF

Thermal Deformation Induced Preload Changein the Tilting Pad Journal Bearing (열변형으로 인한 틸팅패드 저널베어링의 예압 변화)

  • Suh, Junho;Hwang, Cheolho
    • Tribology and Lubricants
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This paper focuses on the thermal deformation induced preload change in the tilting pad journal bearing, using a three-dimensional (3D) thermo-hydro-dynamic (THD) approach. Preload is considered as a critical factor in designing the tilting pad journal bearing. The initial preload measured under nil external load and nil thermal gradient is influenced by two factors, namely, the thermal deformation and elastic deformation. Thermal deformation is due to a temperature distribution in the bearing pads, whereas the elastic deformation is due to fluid forces acting on the pads. This study focuses on the changes induced in preload and film clearance due to thermal deformation. The generalized Reynolds equation is used to evaluate the force of the fluid and the 3D energy equation is used to calculate the temperature of the lubricant. The abovementioned equations are combined by establishing a relationship between viscosity and temperature. The heat transfer within the bearing pads, the lubricant, and the spinning journal is calculated using the heat flux boundary condition. The 3D Finite Element Method (FEM) is used in modeling the (1) heat conduction in the spinning journal and bearing pads, (2) thermal gradient induced thermal distortion of the spinning journal and pads, and (3) viscous shearing, and heat conduction and convection in a thin film. This evaluation method has an increased fidelity, and it can prove to be a cost-effective tool that can be used by designers to predict the dynamic behavior of a bearing.

A Study of the Influence of Void Geometry on Fracture Closure and Permeability (간극의 기하학적 특성이 절리의 수직변형 및 투수성에 미치는 영향에 관한 연구)

    • Tunnel and Underground Space
    • /
    • v.12 no.4
    • /
    • pp.304-311
    • /
    • 2002
  • This study reports the influence of vocid geometry on fracture closure and permeability from numerical experiments. As the aperture distributions of rock fractures are characterized by statistical methods, synthetic fractures have successfully been simulated in this way. Based on the generated fracture models, models for fracture closure and flow calculation have been developed. A fracture closure model has been developed by considering the asperity compression and half-space deformation, and flow calculations have been performed using a finite difference method adopting a local cubic law. The results of numerical experiments have shown that the increase in the aperture spatial correlation leads the fracture closure and the decrease in fracture permeability to increase. Also, it has been indicated that there is an implicit relation between fracture normal stiffness and permeability. The importance of this study is to enhance the understanding the hydro-mechanical behavior of fractured rock massed due to engineering projects.

Structural Safety Assessment of Mark III Membrane Type Liquid Natural Gas Cargo Containment System under Ice Collision (빙 충돌에 대한 Mark III 멤브레인형 LNG CCS의 구조 안전성 평가)

  • Nho, In Sik;Yun, Young-Min;Park, Man-Je;Oh, Young-Taek;Kim, Sung-Chan
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • In this study, a method for analyzing the collision and interaction between ice bergy bits and a Mark III type liquid natural gas (LNG) carrier was considered, and the structural safety of a ship's hull and cargo containment system (CCS) was evaluated. In the analysis, a constitutive model implementing the strain rate dependant mechanical property was used to consider the typical material characteristics of ice rationally. A relatively simple and easy ice structure interaction analysis procedure, compared with the accurate but complicated FSI analysis scheme, was suggested. When the ice bergy bits collided with ship's side hull under the four assumed scenarios, the structural behaviors of the ship structure and LNG CCS were simulated by applying the suggested ice collision analysis procedure using the commercial hydro-code LS-DYNA. In addition, the effects of the shapes and colliding speed of the ice bergy bits on the ice-structure interaction and safety of the CCS were examined in detail.

Instability Analysis of Unsaturated Soil Slope Considering Wet Condition (습윤상태를 고려한 불포화 토사사면의 불안정성 해석)

  • Kim, Yong Min;Kim, Jaehong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1489-1498
    • /
    • 2013
  • The monolithically coupled finite element analysis for a deformable unsaturated soil slope is performed to investigate the effect of antecedent rainfall which is assumed by initial conditions varying degree of saturation (36, 51, 77%) in finite element analysis. The distributions of matric suction and deformation on slope surface obtained from numerical simulation show the instability of antecedent rainfall-induced unsaturated soil slope. Moreover, the numerical analysis using Drucker-Prager model can be checked if a soil slope has reached failure (trial failure criterion $f^{tr}$ >0, plastic behavior) or not (trial failure criterion $f^{tr}$ < 0, elastic behavior). It is found that displacement of slope surface layer increases and the matric suction on soil slope decreases with an increase of initial degree of saturation by antecedent rainfall. Especially, the matric suction of the soil slope in dry condition (S=36%) rapidly decreases rather than that in wet condition (S=51%) at the same rainfall duration. The results of the trial failure criterion ($f^{tr}$ > 0) show slope instability in the toe region and surface of the slopes.

Influence of Pore Pressure Behind a Subsea Tunnel on Its Stability (터널 배면의 간극수압이 해저터널의 안정성에 미치는 영향)

  • You, Kwang-Ho;Lee, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.355-363
    • /
    • 2006
  • In this study, it was analyzed how the pore pressure behind a subsea tunnel influences on the stability of the tunnel. The tunnel is located in the soft rock layer, and a soft sandy layer and weathered soil layer are located on the top of it. Coupled numerical analyses are performed for both drained and undrained condition with varying coefficients of lateral earth pressure. In the case of undrained conditions, the stability of the tunnel was analyzed with different thicknesses of shotcrete. On the other hand, a sensitivity analysis was performed with different hydraulic conductivities and porosities of the shotcrete for the drained conditions. The stability of a subsea tunnel was evaluated in terms of safety factor suggested by You et al.(2000, 2001, 2005) based on the shear strength reduction technique. In this paper, the safety factor of a tunnel was calculated under steady state flow condition during hydro-mechanical coupled analysis. As a result, it was found that the stability of a subsea tunnel could be rather increased by allowing a proper amount of groundwater inflow into a subsea tunnel.

Predicted Hydraulic Behavior in In-Situ Soil Slope Using the Path-Dependent Soil Water Characteristic Curve (불포화 함수특성의 경로의존성을 고려한 현장사면 수리거동 예측)

  • Park, Hyun Su;Song, Young-Suk;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.4
    • /
    • pp.25-34
    • /
    • 2017
  • The soil-water characteristics is the most important state parameter for understanding changes in suction and water contents of unsaturated soil slopes. In the field, the hysteretic behaviors of drying and wetting soil-water characteristic curve are real and the adoption of path-dependent suction-water content is needed to predict the hydro-mechanical analysis of unsaturated soils. In this study, in-situ monitored hydraulic behavior of various soil slopes are compared with the data from numerical analysis with the laboratory soil water characteristic curve. Then, the verifications are performed based on the field monitored data respectively. Therefore, the use of path-dependent soil-water characteristic curves could be more rational for design and analysis of unsaturated soil slopes under rainfall conditions.

Study of Stay Vanes Vortex-Induced Vibrations with different Trailing-Edge Profiles Using CFD

  • Neto, Alexandre D'Agostini;Saltara, Fabio
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.363-374
    • /
    • 2009
  • The 2D flow around 13 similar stay-vane profiles with different trailing edge geometries is investigated to determinate the main characteristics of the excitation forces for each one of them and their respective dynamic behaviors when modeled as a free-oscillating system. The main goal is avoid problems with cracks of hydraulic turbines components. A stay vane profile with a history of cracks was selected as the basis for this work. The commercial finite-volume code $FLUENT^{(R)}$ was employed in the simulations of the stationary profiles and, then, modified to take into account the transversal motion of elastically mounted profiles with equivalent structural stiffness and damping. The k-$\omega$ SST turbulence model is employed in all simulations and a deforming mesh technique used for models with profile motion. The static-model simulations were carried out for each one of the 13 geometries using a constant far field flow velocity value in order to determine the lift force oscillating frequency and amplitude as a function of the geometry. The free-oscillating stay-vane simulations were run with a low mass-damping parameter ($m^*{\xi}=0.0072$) and a single mean flow velocity value (5m/s). The structural bending stiffness of the stay-vane is defined by the Reduced Velocity parameter (Vr). The dynamic analyses were divided into two sets. The first set of simulations was carried out only for one profile with $2{\leq}Vr{\leq}12$. The second set of simulations focused on determining the behavior of each one of the 13 profiles in resonance.

Analysis of Hydro-Fracturing Test Results Using a Mechanical Crack Model (파괴역학모델은 이용한 수압파쇄시험 결과의 해석에 관한 연구)

  • 최용근;배성호;박배한;이정인;전석원
    • Tunnel and Underground Space
    • /
    • v.11 no.3
    • /
    • pp.237-247
    • /
    • 2001
  • In this study, the fracture mechanics model as well as the elastic model was reviewed theoretically and four field case studies were conducted to investigate the feasibility of fracture mechanics model for hydraulic fracturing test. There was a difference between the result by fracture mechanics model and the one by elastic model. And the smaller initial crack length is, the larger the difference is. It is considered that the fracture mechanics model can be applied to the specific case of which the crack length is known. In this study, the rock tensile strength is measured using fracture mechanics model, brazilian test and elastic model. The measured tensile strength by the fracture mechanics model is the largest and the elastic model is the smallest. This result is due to the size effect of the each test. And the tensile strength from the elastic model for hydraulic fracturing test can be used to estimate the in-situ rock tensile strength.

  • PDF

Development of a Submerged Propeller Turbine for Micro Hydro Power

  • Kim, Byung-Kon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.45-56
    • /
    • 2015
  • This paper aims to develop a submerged propeller turbine for micro hydropower plant which allows to sustain high values of efficiency in a broad range of hydrological conditions (H=2~6 m, $Q=0.15{\sim}0.39m^3/s$). The two aspects to be considered in this development are mechanical simplicity and high-efficiency operation. Unlike conventional turbines that have spiral casing and gear box, this is directing driving and no spiral casing. A 10 kW class turbine which has the most high potential of the power generation has been developed. The most important element in the design of turbine is the runner blade. The initial blade is designed using inverse design method and then the runner geometry is modified by classical hydraulic method. The design process is carried out in two steps. First, the blade shape is fix and then other components of submerged propeller turbine are designed. Computational fluid dynamics analyses based on the Navier-Stokes equations have been used to obtain overall performance data for the blade and the full turbine, respectively. The results generated by performance parameters(head, guide vane opening angle and rotational speed) variations are theoretically analysed. The evaluation criteria for the blade and the turbine performances are the pressure distribution and flow's behavior on the runner blades and turbine. The results of simulation reveals an efficiency of 91.5% and power generation of 10.5kW at the best efficiency point at the head of 4m and a discharge of $0.3m^3/s$.