• Title/Summary/Keyword: hydraulic test

Search Result 1,719, Processing Time 0.03 seconds

General Steady-State Shape Factors in Analyzing Slug Test Results to Evaluate In-situ Hydraulic Conductivity of Vertical Cutoff Wall (순간변위시험(slug test)시 연직차수벽의 현장투수계수를 산정하기 위한 형상계수 연구)

  • Lim, Jee-Hee;Lee, Dong-Seop;Nguyen, Thebao;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.105-116
    • /
    • 2011
  • No analytical solution exists for evaluating in-situ hydraulic conductivity of vertical cutoff walls by analyzing slug test results. Recently, an analytical solution to interpret slug tests has been proposed for a partially penetrated well in an aquifer. However, this analytical solution cannot be directly applied to the cutoff wall because the solution has been developed exclusively for an infinite aquifer instead of a narrow cutoff wall. To consider the cutoff wall boundary conditions, the analytical solution has been modified in this study to take into account the narrow boundaries by introducing the imaginary well theory. Two boundary conditions are considered according to the existence of filter cakes: constant head boundary and no flux boundary. Generalized steady-state shape factors are presented for each geometric condition, which can be used for evaluating the in-situ hydraulic conductivity of cutoff walls. The constant head boundary condition provides higher shape factors and no flux boundary condition provides lower shape factors than the infinite aquifer, which enables to adjust the in-situ hydraulic conductivity of the cutoff wall. The hydraulic conductivities calculated from the analytical solution in this paper give about 1.2~1.7 times higher than those from the Bouwer and Rice method, one of the semi-empirical formulas. Considering the compressibility of the backfill material, the analytical solution developed in this study was proved to correspond to the case of incompressible backfill materials.

Variation Characteristics of Hydraulic Gradient and Major Flow Direction in the Landfill Soils (매립지 토양층의 수리경사와 주 흐름 방향의 변동특성)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Kim, Sung-Soo;Kwon, Byung-Hyuk
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.315-323
    • /
    • 2009
  • Hydraulic gradient of the landfill soils is estimated by Devlin (2003) method, and its variation characteristics from rainfall and permeability of the aquifer material are analyzed. The study site of 18 m $\times$ 12 m is located in front of the Environment Research Center at the Pukyong National University, and core logging, slug/bail test and groundwater monitoring was performed. The sluglbail tests were performed in 9 wells (except BH9 well), and drawdown data with elapsed time for bail tests were analyzed using Bouwer-Rice and Hvorslev methods. The average hydraulic conductivity estimated in each of the test wells was ranged $1.991{\times}10^{-7}{\sim}4.714{\times}10^{-6}m/sec$, and the average hydraulic conductivity in the study site was estimated $2.376{\times}10^{-6}m/sec$ for arithmetic average, $1.655{\times}10^{-6}m/sec$ for geometric average and $9.366{\times}10^{-7}m/sec$ for harmonic average. The permeability of landfill soils was higher at the east side of the study site than at the west side. Groundwater level in 10 wells was monitored 44 times from October 2 to November 7, 2007. The groundwater level was ranged 1.187$\sim$1.610 m, and the average groundwater level range in each of the well showed 1.256$\sim$1.407 m. The groundwater level was higher at the east side than at the west side of the study site, and this distribution is identify to it of hydraulic conductivity. The hydraulie gradient and the major flow direction for 10 wells were estimated 0.0072$\sim$0.0093 and $81.7618{\sim}88.0836^{\circ}$, respectively. Also, the hydraulic gradient and the major flow direction for 9 wells were estimated 0.0102$\sim$0.0124 and $84.6822{\sim}89.1174^{\circ}$, respectively. The hydraulic gradient of the study site increased from rainfall (83.5 mm) on October 7, causing by that the groundwater level of the site with high permeability was higher. The hydraulic gradient estimated on and after October 16 was stable, due to almost no rainfall. Thus, it was confirmed that the variation of the hydraulic gradient in the landfill soils was controlled by the rainfall.

Design of Variable Speed SRM Drive for Hydraulic Pump Application (유압펌프용 가변속 SRM 구동시스템 설계)

  • Lee, Dong-Hee;Kim, Bong-Chul;An, Young-Joo;Ahn, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • This paper proposes an SRM drive system to improve the drive efficiency of the hydraulic system. From the maximum hydraulic pressure and flow rate required by the hydraulic system, a proper SRM is designed and tested. The proposed SRM drive system controls oil pressure of the hydraulic system as well as motor speed. A 2.2[kW], 12/8-pole SR motor and digital controller based DSP are designed and tested for hydraulic pump system. The test results show that the system has some good features such as high efficiency and rapid response characteristics.

A Study on the Application of the Real-Time Simulator (실시간 모의시험기의 적용에 관한 연구)

  • 장성욱;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.191-191
    • /
    • 2000
  • Hydraulic servo system is difficult to be made up and each component is very expensive, it takes long for actual system to make and test and it costs a high price. Because of these characteristics of hydraulic servo system, a real time simulator that could describe behavior of real system is highly demanded, without composing real hydraulic system. So, many studies have been (lone on these subjects and many simulators are developed with superiority. Since the nonlinearity of a hydraulic system common simulator have composed of many calculative times byusing DSP(Digital Signal processing) and have made it possible to find the situations of the system in real time, calculating hydraulic simulation and controller separately. In this study, we suggest real-time simulator that could describe real system without ordinary DSP card. This simulator is composed of 80196kc and personal computer. DSP card that has calculated complex numerical equation is supplanted by personal computer and 80196kc generates control signals independently out of the personal computer. In all process, personal computer is synchronized with one-board microprocessor within sampling time in the closed loop system. This makes it possible to be described in hydraulic servo system in real time. And to make a comparison between the result of the real-time simulator and a hydraulic servo system.

  • PDF

Flow Distribution and Pressure Loss in Subchannels of a Wire-Wrapped 37-pin Rod Bundle for a Sodium-Cooled Fast Reactor

  • Chang, Seok-Kyu;Euh, Dong-Jin;Choi, Hae Seob;Kim, Hyungmo;Choi, Sun Rock;Lee, Hyeong-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.376-385
    • /
    • 2016
  • A hexagonally arrayed 37-pin wire-wrapped rod bundle has been chosen to provide the experimental data of the pressure loss and flow rate in subchannels for validating subchannel analysis codes for the sodium-cooled fast reactor core thermal/hydraulic design. The iso-kinetic sampling method has been adopted to measure the flow rate at subchannels, and newly designed sampling probes which preserve the flow area of subchannels have been devised. Experimental tests have been performed at 20-115% of the nominal flow rate and $60^{\circ}C$ (equivalent to Re ~ 37,100) at the inlet of the test rig. The pressure loss data in three measured subchannels were almost identical regardless of the subchannel locations. The flow rate at each type of subchannel was identified and the flow split factors were evaluated from the measured data. The predicted correlations and the computational fluid dynamics results agreed reasonably with the experimental data.

Prediction Model for Saturated Hydraulic Conductivity of Bentonite Buffer Materials for an Engineered-Barrier System in a High-Level Radioactive Waste Repository

  • Gi-Jun Lee;Seok Yoon;Bong-Ju Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.225-234
    • /
    • 2023
  • In the design of HLW repositories, it is important to confirm the performance and safety of buffer materials at high temperatures. Most existing models for predicting hydraulic conductivity of bentonite buffer materials have been derived using the results of tests conducted below 100℃. However, they cannot be applied to temperatures above 100℃. This study suggests a prediction model for the hydraulic conductivity of bentonite buffer materials, valid at temperatures between 100℃ and 125℃, based on different test results and values reported in literature. Among several factors, dry density and temperature were the most relevant to hydraulic conductivity and were used as important independent variables for the prediction model. The effect of temperature, which positively correlates with hydraulic conductivity, was greater than that of dry density, which negatively correlates with hydraulic conductivity. Finally, to enhance the prediction accuracy, a new parameter reflecting the effect of dry density and temperature was proposed and included in the final prediction model. Compared to the existing model, the predicted result of the final suggested model was closer to the measured values.

A Study on the Circuit Composition and Characteristics Analysis for Heavy-Duty Vehicular Hybrid Hydraulic Driving System (대형 자동차 하이브리드 유압 구동시스템의 회로구성과 특성해석에 관한 연구)

  • 이재구;이재천;한문식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.197-204
    • /
    • 2004
  • An accumulator in hydraulic systems stores kinetic energy during braking action, and then that controls hasty surge pressure. An energy recovery system using accumulator seems to be advantageous for ERBS due to its high energy density. This study suggests a method to decide suitable accumulator volume for ERBS. The method is based upon energy conservation between kinetic energy of moving inertia and elastic energy of accumulator. The energy conversion was analyzed and a simple formula was derived. Also accumulator tests were conducted for different load mass and motor speed. A series of test work were carried out in the laboratory and the dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, were investigated in both brake action and acceleration action and these results show that the proposed design is effective for decision accumulator volume in ERBS.

Presumption of Slipper-pad Fault Condition for Hydraulic Rotary Actuator (마멸입자 해석을 통한 유압로터용 Slipper - Pad의 손상상태 추정)

  • 전성재;조연상;서영백;박흥식
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.62-67
    • /
    • 2000
  • This paper was undertaken to do morphological analysis of wear debris for slipper-Pad of hydraulic rotary acuator. The lubricating wear test was performed under different experimental conditions using the wear test device and wear specimens of the pin on disk type was rubbed in paraffinic base oil by three kinds of lubricating materials, varying applied load, sliding distance. The four shape parameters(50% volumetric diameter, aspect, roundness and reflectivity) are used for morphological analysis of wear debris. The results showed that the four shape parameters of wear debris depend on a kind of the lubricating condition. It was capable of presuming wear volume for slipper-pad of hydraulic rotary acuator on driving time.

  • PDF

Experimental Study on Seismic Performance of Base-Isolated Bridge

  • Chung, Woo Jung;Yun, Chung Bang;Kim, Nam Sik;Seo, Ju Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.3
    • /
    • pp.51-60
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrated that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation systems using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminate rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the deck acceleratino and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF