• 제목/요약/키워드: hydraulic test

검색결과 1,730건 처리시간 0.031초

유출수 및 유실토량 측정장치에 관한 수리시험 (Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss)

  • 유한열
    • 한국농공학회지
    • /
    • 제10권1호
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

강변여과수의 질산성질소 제거를 위한 생물학적 반응벽체의 준파일럿 실험에 관한 연구 (A Semi-Pilot Test of Bio-barrier for the Removal of Nitrate in Bank Filtrate)

  • 문희선;장선우;남경필;김재영
    • 대한환경공학회지
    • /
    • 제27권3호
    • /
    • pp.302-308
    • /
    • 2005
  • 질산성 질소는 강변여과수에서 가장 흔히 발견되는 오염물질 중의 하나이다. 본 연구에서는 황을 이용한 독립영양탈질 공정을 강변여과수의 질산성 질소제거를 위한 반응벽체 기법에 도입하였다. 본 연구의 목적은 현장에서의 실제 강변여과수를 이용한 주 파일럿 실험을 통해 반응벽체 시스템에서 미생물 접종의 영향과 대체 알칼리도 공급원으로서 굴패각의 영향을 알아보고, 유량변화 및 체류시간 변화에 따른 질산성 질소 제거효율을 평가하는 것이다. 황과 석회석 또는 굴패각으로 구성된 준 파일럿 규모의 투수성 반응벽체(PRB) 6기를 경남 낙동강 유역 강변여과수 취수 현장에 설치하여 운전한 결과, 하수처리장의 혐기 소화 슬러지로부터 분리배양된 황탈질미생물 콘소시움 뿐만 아니라 굴패각의 자생미생물의 활성에 의해서 강변여과수의 질산성 질소가 제거됨을 확인하였고 석회석뿐만 아니라 굴패각도 시스템의 pH 조절을 위한 알칼리도 공급원으로 이용될 수 있음을 알 수 있었다. 그러나 알칼리도 공급원으로서 굴패각의 이용은 높은 황산이온의 농도와 고형물의 농도를 야기하였다. 80 cm의 반응벽체 두께에서, 유량을 66에서 132 mL/min까지 증가시킴으로써 체류시간을 15에서 7.5시간으로 감소시킴에 따라 질산성 질소 제거효율은 75에서 58%로 감소하였다.

3-D 전산유체를 이용한 급속혼화조 형상에 따른 난류 유동장 연구 (The Effects of Mixer Geometry on Hydraulic Turbulence : Computational Modeling)

  • 박노석;김성훈;박희경
    • 대한환경공학회지
    • /
    • 제22권7호
    • /
    • pp.1173-1182
    • /
    • 2000
  • 지금까지 급속혼화는 정수처리 공정 중에서 매우 중요한 공정으로 인식되어 왔다. 특히, 응집제의 원수내 확산은 급속혼화 공정에 이어지는 flocculation이나 filtration 공정에 지대한 영향을 미치게 되므로 지금까지 많은 연구자들이 혼화장치의 개발이나 효율적인 혼화방식에 관해 연구를 해왔다. 그러나 선행 연구자들은 급속혼화에 있어서 중요한 변수로 응집제 주입량, pH, 임펠러의 회전속도, 그리고 G값만을 고려하였으나, 실제 응집제와 콜로이드입자와의 충돌기회에 지대한 영향을 미치는 급속혼화 공정상에서 발생되는 난류장을 간과하였다. 특히 급속혼화에서의 난류의 발생은 G값에 전적으로 의지하여 난류장의 평균값으로 혼화조내의 난류를 표현하여 왔으며, 혼화조의 형상에 따라 달라지는 난류장 해석은 연구가 미약한 실정이다. 이에 본 연구는 급속혼화에서 난류장 해석의 중요성을 인식하고 혼화조의 형상 변화에 따라 달라지는 난류장을 전산유체 프로그램을 통하여 해석하였다. 그리고 혼화조 형상을 달리하며 jar-test를 수행한 결과 배플이 없는 원형 jar의 경우가 배플이 장착된 원형 jar나 Hudson jar보다 응집제의 확산에 따른 탁도 제거효율이 좋은 것으로 나타났으며, 전산유체 프로그램을 이용하여 각각 모사한 결과 벽면효과나 사류지역의 발생 등으로 배플이 없는 원형 jar가 혼화에 효과적인 난류장이 분포되는 것으로 확인되었다. 이 결과를 통해 혼화조 형상이 응집제의 확산이나 난류장의 발생에 영향을 미치는 것으로 결론 내릴 수 있다.

  • PDF

해안가 암반대수층에서 양수시험 시 조석효과에 의한 수리특성 (The hydraulic characteristics with tidal effect for pumping test at the costal rock aquifer)

  • 김태영;강동환;김성수;김동수;정상용
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.1929-1933
    • /
    • 2008
  • 조석에 의한 지하수위변동이 발생하는 해안가 암반대수층에서 고조(high tide)과 저조(low tide) 조건에서의 차이를 규명하기 위한 양수시험이 수행되었다. 본 연구에서 양수시험이 수행된 시험대 수층은 암반층으로서 시험공들은 해안가에서 약 180 m 이격되어 있으며, 양수정(MW1공)과 관측정(MW2공)의 이격거리는 8.05 m 이다. 양수정과 관측정 모두 공 내경은 0.205 m 이며, 케이싱심도는 지표면하 19 m 정도이다. 그리고, 양수정과 관측정의 지하수위는 지표면하 5 m 정도에 형성 되어 있으며, 시험대수층의 두께는 약 40 m 정도이다. 양수시험은 총 3회 수행되었으며, 모든 시험에서 수중모터 설치심도는 지표면하 30 m 이고 양수율은 $75\;m^3/day$로서 동일하였다. 그러나, 양수시작 시간의 차이를 두어 고조 후 1회(1차 시험), 저조 후 2회(2차 및 3차 시험) 수행되었다. 양수정과 관측정에서 자동수위측정기(Model 3001, Solinst)를 설치하여 관측된 지하수위변동 자료에 의하면, 조석현상 발생 후 시험공 내 지하수위변동 경과시간은 고조(high tide) 후 2시간, 저조 (low tide) 후 1시간 정도인 것으로 나타났다. 따라서, 양수시험 시 1차 시험은 고조 후 2시간 경과한 시점에서, 2차 및 3차 시험은 저조 후 1시간 경과한 시점에서 양수가 시작되었다. 양수시험에 의한 경과시간에 따른 수위강하량 그래프에서는 고조조건이 저조조건에 비해 수위강하량이 더 적은 것으로 나타났다. 이러한 원인은 저조에 비해 고조 조건에서는 해수에 의한 지하수위가 상승하여, 동일한 양수조건에서 수위강하량이 적게 나타난 것이다. 양수시험 자료가 AQTESOLV 3.5 프로그램을 이용하여 해석되었다. Theis method에 의해 산정된 수리전도도는 고조 조건의 양수시험에서는 $4.159{\times}10^{-6}\;m/sec$, 저조 후에서는 각각 $3.818{\times}10^{-6}\;m/sec$$3.926{\times}10^{-6}\;m/sec$ 이었다. 저조 후에 비해 고조 후의 수리전도도가 5% 이상 높은 것으로 산정되었다. 이상의 연구 결과들에 의해, 해안가 암반대수층에서는 양수시험 시 조석효과에 의한 수리적인 변동을 고려한 설계와 해석이 수행되어야함을 확인할 수 있었다.

  • PDF

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

알칼리 자극제로서 미분시멘트와 순환골재가 고로슬래그 다량치환 콘크리트의 공학적 특성 및 미세구조에 미치는 영향 (Effect of Fine Particle Cement and Recycled Aggregates as Alkali Activator on the Engineering Properties and Micro-Structure of High Volume Blast Furnace Slag Concrete)

  • 한민철;이향재;한천구
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.602-608
    • /
    • 2013
  • 본 연구에서는 BS다량 치환 콘크리트의 알칼리자극제로서 순환골재 및 고분말도의 FC를 복합 사용한 콘크리트의 제반 공학적 특성 및 미시적 분석을 실시하였다. FC 치환에 따른 슬럼프 및 공기량은 큰 차이가 없었으며, 응결시간은 FC 치환에 따라 비례적으로 단축되는 것으로 나타났다. FC 치환에 따른 압축강도는 고분말도의 FC가 치환됨에 따라 촉진된 수화반응 및 순환골재의 미수화 시멘트의 알칼리 용출로 인해 BS의 잠재수경성 반응을 촉진시켜 초기 및 28일 재령에서의 Plain 대비 강도저하를 상당부분 회복할 수 있었으며, 특히 향후 재령이 경과함에 따라 포졸란 반응의 활성화로 추가적인 강도향상이 기대된다. 탄산화 저항성의 경우 큰 차이가 없으며, 세공분포의 경우 FC 치환률이 증가함에 따라 $0.1{\mu}m$이하의 미세 공극분포가 급격히 증가하는 경향을 보였고, SEM 측정결과 FC 치환에 따른 7일 및 28일에서의 C-S-H 및 $Ca(OH)_2$의 생성을 확인하여 FC가 BS 다량치환 순환골재 콘크리트의 알칼리 자극에 기여함을 확인 할 수 있었다.

콘크리트 혼합재의 석회반응성에 관하여 (A Study on the Lime Reactivity of Concrete Admixtures)

  • 장복기;윤정한
    • 한국세라믹학회지
    • /
    • 제39권5호
    • /
    • pp.452-459
    • /
    • 2002
  • 고로슬래그와 플라이 애쉬의 석회 반응성을 수열조건 하에서 각각 고찰하였다. 수열반응 조건은 CaO-$SiO_2$ 비(C/S), 수열온도($140{\circ}C$$180{\circ}C$)및 반응시간(20~60시간)이었다. 수열반응성은 각 수경성 재료에 함유된 $SiO_2$와 (순수)석회 사이의 반응률 및 반응 시편의 압축강도를 측정하여 조사하였다. 그리고 본 반응성 고찰을 위하여 기공률 측정 및 XRD 분석도 수행하였다. 압축강도 물성은 시편의 기공률 및 CaO-$SiO_2$ 반응성과 연계하여 고찰하였으며, XRD 분석으로 수열반응 중 C/S가 변화함을 확인할 수 있었다. 고로슬래그 중의 $SiO_2$는 플라이 애쉬에 함유된 $SiO_2$ 보다 석회반응성이 우수하여 전자의 경우 시편은 훨씬 높은 강도를 나타내었다. 수열반응 온도 $180{\circ}C$ 및 40시간의 조건에서 고로슬래그는 최고 강도 $807kg/cm^2$을 나타냈으며, 플라이 애쉬의 경우 최고 강도는 $397kg/cm^2$ 이었다.

현장적용 디스크커터의 내부부품 분석 (Analysis of inner parts in the disc cutters applied to the field tests)

  • 배규진;최순욱;장수호;이규필;송봉찬;김갑부
    • 한국터널지하공간학회 논문집
    • /
    • 제17권4호
    • /
    • pp.473-485
    • /
    • 2015
  • 디스크커터 내부부품의 손상과 관련된 원인은 씰(seal)부의 손상으로 인한 윤활유 부족, 토사 및 수분의 침투, 과부하, 과열, 조립문제, 소재문제 등이 있으며 손상 정도에 따라 디스크커터의 작동여부, 즉 회전이 가능한지가 나타난다. 따라서 디스크커터 회전문제에서의 핵심은 베어링의 작동여부라고 할 수 있다. 본 연구는 TBM의 굴착도구인 디스크커터의 재활용에 도움이 되고자 현장 적용된 디스크커터를 회수한 후 분해하여 내부부품을 조사하고 분석하였다. 그 결과, 허브의 부하영역에서의 스크래치는 재활용을 위해 가공작업이 필요한 것으로 나타났으며, 플로팅 씰의 래핑면과 오일상태는 재활용을 위한 성능파악에 필요한 시험으로 판단되었다. 특히 플로팅 씰은 베어링의 정상작동여부에 중요한 영향을 미치는 부품으로 파악되었다. 그 외의 베어링, 샤프트, 씰 리테이너에서는 특이사항이 없는 것으로 나타났다.

SMART-ITL 1 계열 피동안전계통을 이용한 유동분사기 성능에 대한 실험연구 (An Experimental Study on Flow Distributor Performance with Single-Train Passive Safety System of SMART-ITL)

  • 류성욱;배황;양진화;전병국;윤은구;김재민;방윤곤;김명준;이성재;박현식
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.124-132
    • /
    • 2016
  • 노심보충탱크 상부에 설치되는 유동분사기 형상에 따른 냉각수 주입특성 및 탱크 내에서의 열수력 현상 변화를 파악하기 위한 안전주입배관 2인치 파단 소형냉각재상실사고(SBLOCA) 모의시험이 잔열 및 피동잔열제거계통(PRHRS) 모의 없이 수행되었다. 두 가지 형상의 유동분사기를 설치하고 수행한 각각의 시험은 거의 유사한 초기 및 경계조건에서 수행되었으며, 이로 인해 반복시험에 대한 재현성이 충족되었다고 판단된다. 시험결과는 유동분사기의 종류(본 시험에서는 구멍의 개수에 해당)에 관계없이 유사한 열수력학적 거동을 보였으며, 초기 주입유량 관점에서는 구멍의 개수가 2배인 B형이 A형에 비해 좀 더 우수한 주입 성능을 보였다. 노심보충탱크 격리 밸브가 개방된 후 압력평형배관을 통해 유입되는 고온의 원자로냉각재는 상부 헤더에서 상대적으로 저온인 $50^{\circ}C$ 물과 혼합되면서 증기 응축과 같은 상변화에 의한 압력 변동을 동반하는 다차원 열유동 현상을 일으키게 된다. 이로 인해 초반부 노심보충탱크 주입 유량은 상온운전 조건에서 보다는 작게 되고, 일정시간 경과 후에는 유사한 주입유량 특성을 보였다.

한국의 농업용 방사상 집수정 현황 및 지속가능성 (Agricultural Radial Collector Wells in South Korea and Sustainability)

  • 홍순욱;송성호;안중기;김진성
    • 지질공학
    • /
    • 제26권3호
    • /
    • pp.331-337
    • /
    • 2016
  • 농업용 방사상 집수정은 한국농어촌공사에서 1983년 경북 상주시 이안면에 지하댐 건설과 함께 최초로 설치하였으며, 지금까지 총 98개소의 농업용 방사상 집수정을 관리하고 있다. 이중 20개소는 농업용으로 건설된 5개의 지하댐 상류지역에 설치되었으며, 나머지 78개소는 지하댐 설치와 관계없이 설치되었다. 농업용 방사상 집수정은 대부분 1980년~1990년대 개발되었으며, 83개소는 설치한지 20년 이상 경과된 시설이다. 방사상 집수정의 집수 우물통은 일반적으로 내경 3.5 m, 심도 10 m 이내이며, 수평집수관은 65 mm 구경으로 30 m까지 천공한 후 PVC 집수관을 설치하였으며, 집수정 별로 9~28개 설치되어 있다. 집수정설치지점과 하천과의 이격 거리는 10~1,200 m이며, 최대양수량은 2,000~10,000 m3/day 이다. 방사상 집수정은 개발후 물리·화학적 원인에 의한 공막힘 현상 등으로, 취수량이 감소하여 효율이 저하되는 문제점이 있다. 본 연구에서는 30년이상 경과된 방사상 집수정의 수평집수관에 대하여 서징과 고압세척을 실시하고, 양수시험 및 TV검층을 실시하여 우물세척에 의한 수평집수관 폐색제거 효과를 분석하였다. 우물세척후 비양수량은 67% 증가하였으며, TV검층결과 집수우물통에서 가까울수록 수평집수관 스트레너의 막힘(Clogging) 정도가 심한 것을 확인하였다. 본 연구결과를 활용하여 방사상 집수정에 대한 모니터링과 우물 효율 개선방안을 수립하고, 주기적인 사후관리를 통해 방사상 집수정의 지속가능한 이용을 도모 할 수 있을 것으로 사료된다.