• Title/Summary/Keyword: hydraulic retention time (HRT)

Search Result 201, Processing Time 0.02 seconds

A study on treatment of emulsified oil waste water in vessels by electrochemical treatment system (전기화학적 처리장치에 의한 유화된 선저폐수의 처리에 관한 연구)

  • Kwon K. S.;Jeong H. J.;Lee B. H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.3
    • /
    • pp.45-53
    • /
    • 2003
  • Discharging untreated bilge to the ocean is a cause of marine pollution. In general, bilge water contains free and/or emulsified forms of oil. Free form of oil can easily be separated by gravimetric flotation and/or proper filtration processes. However, those simple physicochemical processes could not separate emulsified oil without adding proper chemicals. Electrolytic flotation is one of promising technologies able to fulfill the effluent standard requirement, which is below 15 ppm of oil content. In this research, Electrochemical process consisting of electrochemical flotation basin was studied for the treatment of emulsified oil. In order to estimate, the effectiveness of oil separation equipment influent concentration of oil and HRT(Hydraulic retention time) were considered. Also, lab-scale electrochemical process was designed and operated in the condition of various HRT, current density, and electrode gap. Through the research, following results were obtained. From the experiment of bench scale electrochemical treatment process, it was demonstrated that the emulsified oil was treated effectively and the removal efficiency of emulsified oil from wastewater was increased with HRT and current density.

  • PDF

Effects of Nitrifying Bacterial Communities with Different HRTs and Backwashing Periods in Modified BAF Process (Modified BAF 공정에서 HRT 및 역세주기가 질산화 미생물의 군집에 미치는 영향)

  • Jung, Chul-Soo;Park, Jeung-Jin;Ju, Dong-Jin;Kwon, Soo-Youn;Choi, Won-Seok;Byun, Im-Gyu;Park, Tae-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.920-926
    • /
    • 2007
  • The upflow Biobead$^{(R)}$ process, one of biological aerated filters (BAF), which was used commercially, invented for removal of organic materials and nitrification. This process was modified to enhance the ability of denitrification through the induction of pre-anoxic tank. In this research, we investigated the effects of hydraulic retention time (HRT) and backwashing period in aerobic tank. The characteristics of nitrifying bacteria, which are composed of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB), also investigated using fluorescence in situ hybridization (FISH). Even though the HRT was shortened, the efficiency of nitrification was not decreased when the organic loading rate and ammonium-nitrogen loading rate were $2.10kg/m^3/day$ and $0.25kg/m^3/day$, respectively. And then the distribution ratios of AOB and NOB showed the similar patterns. However, when the backwashing period was lengthened from 12 hours to 24 hours in aerobic 1 tank, the nitrification efficiency was decreased to 63.9% from 89.2%. The results of FISH explained that this decrease of nitrification efficiency was caused by the decrease of distribution ratio of AOB in aerobic 1 tank. The nitrification efficiencies of aerobic 1 and aerobic 2 tank were increased when the backwashing period was lengthened because of relative high distribution ratios of nitrifying bacteria.

The Effects of Changing of Hydraulic Retention Time and Charging Media on the Removal of Nitrogen and Phosphorus in the Up-flow Anaerobic/Anoxic Reactor and Water-mill for Sewage Treatment (상향류식 혐기성조, 무산소조 및 수차호기조를 이용한 하수처리시 수리학적 체류시간의 변화와 메디아 충진이 질소 및 인 제거에 미치는 영향)

  • Shin, Myoung-Chul;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.64-70
    • /
    • 2009
  • The aims of this study is to examine the effects of the changes in HRT(Hydraulic Retention Time) and media charge in a water-mill, among other operation factors, on the nitrogen and phosphorus removal in order to use up-flow anaerobic reactors, anoxic reactors and water-mill aerobic reactors for sewage treatment. The extension of HRT improved the nitrogen removal efficiency, however the removal pattern was constant regardless of HRT. The removal of phosphorus was constant (80%-90%) regardless of the change in HRT. The removal rate with change in influx load varied such that at the OLR (Organic Load Rate) of 1-3 kg/d, the T-N removal efficiency was 80.7%-88.9% and the T-P removal efficiency was 82.9%-89.3% while at the NLR (Nitrogen Loading Rate) of 0.108-0.156 kg/d the removal efficiencies were 80.7-88.9% (T-N) and 82.9-89.3% (T-P). The analyses of the nitrogen and phosphorous removal characteristics with the C/N and C/P ratio showed that the mean T-N removal rate was 88% at the C/N ratio of 1.2-2.6, and that the mean T-P removal rate was 86% at the C/P ratio of 7.2-14.1. Also, the analysis of nitrogen and phosphorous removal characteristics were analyzed in relation to media charge. The comparison between with and without media charge in the water-mill showed that while the nitrogen removal efficiencies were 86-94% and 85-89% respectively, the difference of phosphorous removal efficiencies were between the two conditions was not significant, thus it suggested that the media charge has less effect on the removal efficiency of phosphorous compared to that of nitrogen.

A Study on the Biogas Production and VSS Concentration in Organic Wastewater Treatment Using a Downflow Anaerobic Packed Bed Reactor with HRT Change (하향유식 혐기성 고정상 생물반응기에서 유기성 폐수의 HRT변화에 따른 Biogas 생성 및 VSS 농도에 관한 연구)

  • 김정회;강동수;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.17-21
    • /
    • 1993
  • Characteristics of a downflow anaerobic packed bed reactor with raschig ring ceramics as a packing were measured and discussed for the basic evaluation of the process. A synthesized glucose substrate wastewater were used as a feed and process characteristics such as pH, biogas production, composition of produced gas, COD removal and VSS were measured with the hydraulic retention time (HRT) changing from 0.25 to 2 days. As a result, this type of reactor was applicable in continuous operation within the given HRT range and the transient period approaching the steady state was about 20 days. The content of methane in produced gas increase with HRT was always high above 50% enough to use as energy source. The COD removal efficiency increased gradually as HRT increased. The axial profile of VSS concentration in the reactor usually showed the maximum at the lower region and the minimum at the middle. The VSS concentration at the upper region and the exit appeared similarly. However, at 0.25 day of HRT, the VSS concentration of effluent became higher than that of the upper region. Therefore the optimum HRT of this reactor occurred about 0.5 day, at which the production of methane began to be just stabilized and loss of VSS and COD removal were resonable.

  • PDF

Treatment of Organic Wastewater by the Anaerobic Fixed-Film Process (혐기성 생물막법에 의한 유기성 배수의 처리)

  • 김용대;정경훈
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.41-47
    • /
    • 1991
  • A study on the effects of volumetric loading rate, surface loading rate and hydraulic. retention time (HRT) for the anaerobic treatment was conducted with the anaerobic fixed-film process using synthetic wastewater at lower temperature than that of conventional anaerobic treatment. The results are as follows 1. Alkalinity and pH value decreased as the hydraulic retention time increased 2. Increase of the volumetric lodaing rate led to increasl of effluent COD concentration and decrease of COD removal efficiency. 3. The removed volumetric loading rate increased linearly according to the increase of the volumrtric loading rate. 4. Similarly, the linear increase of the removed surface loading rate was noticed with an increase of the surface loading rate.

  • PDF

Biological Treatment of Textile Wastewater by Anaerobic-Aerobic Reactor System (Pilot 혐기-호기 공정을 이용한 염색폐수의 생물학적 처리)

  • 박영식;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.11-20
    • /
    • 2001
  • An anaerobic sludge-aerobic fixed-bed biofilm(packed with ceramic support carrier of 1 inch size) reactor system was built up to treat textile wastewater. The efficiency of reactor system was examined by determining the effects of textile wastewater ratio(from 25% to 100% at HRT 24 h). The influent range of SCOD concentration and color were 1,036~1,357 mg/L, and 1,487~1,853 degree, respectively. When textile wastewater ratio was 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% and the removal efficiency of the whole system were 75.8%. Color removal efficiency by the anaerobic stage were 45.4%(soluble color), and the removal efficiency of the whole system were 70.2%. In the A/A reactor system, the aerobic stage played an important role in removing both color and COD as well as anaerobic stage.

  • PDF

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

Improvement of Organics and Nitrogen Removal by HRT and Recycling Rate in Air Lift Reactors (공기부상반응조에서 체류시간과 반송율에 의한 유기물질 및 질소제거 향상에 관한 연구)

  • Kim, Jin-Ki;Yu, Sung-Whan;Lim, Bong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 2006
  • This study was performed to evaluate the air lift reactors (ALR) by variations of HRT and recycling rate. Air lift reactor was composed of bioreactor and clarifier above it. To remove organic matters and nitrogen through the formation of microbic film and filtration, bio-filter reactors were filled with clay, glass, bead, waste plastic, respectively. Influent wastewater was fed to biofilter reactor, and effluent wastewater from bio-filter reactor was injected ALR again, instead of adding external carbon source. Effluent BOD concentration was satisfied with lower than 10 mg/L in recycling rate 100% regardless of the variation of HRT and the kinds of media materials. In HRT 4 hr, recycling rate 100%, BOD removal efficiency rate was from about 85 to 90%, COD removal efficiency rate was higher than 90%. Effluent TN concentration was satisfied with less than 20 mg/L, if HRT was maintained by over than 6 hr regardless of recycling rate and media materials. Over than HRT was 4 hr, microbes concentration in air lift reactor was maintained over than 2,500 mg/L constantly, not sensitive to environmental condition, and organic removal was effective as it was higher.

Ammonia-nitrogen Removal in Sea Water by Using Electrolysis (전기분해법에 의한 해수내의 암모니아성 질소 제거)

  • 이병헌;이제근;길대수;곽순열
    • Journal of Aquaculture
    • /
    • v.10 no.4
    • /
    • pp.435-438
    • /
    • 1997
  • Biological ammonia removal system have been used conventionally for the seawater fish farming. But this process requires long hydraulic retention times and large area. Also it has a trouble of NO3-N accumulation in the system. Therefore, this study was conducted to find out the feasibility of effective nitrogen removal efficiency in the sea water fish farming system by electolysis. As the result, electrolysis system showed a good ammonia and nitrate nitrogen removal and E. coli sterilization efficiencies. Because of the high salinities in the seawater for electron transfer, electrolysis is an effictive water treatment process for seawater fish farming. The relation among ammonia removal efficiency, hydraulic retention time (HRT) and electric wattage (watt) with 10 mm electrod distance isas follow ; log [$NH_4^$+-N(%)]=0.431log(HRT(sec)$\times$Watt)+0.88(r=0.950) And the relation between ammonia removal efficiency and residual chlorine concentration in the seawater is as follow; $$NH_4^+-N(%)=48\cdotlog[Residual\;chlorine(mg/\ell)+28(r=0.892)$$

  • PDF

Methane Production by Anaerobic Digestion of Grain Dust in a Plug Flow Digester (플러그 흐름 소화기 속에서 Grain Dust의 혐기성 소화에 의한 메탄가스 생산)

  • Tae-Kyung Yoon;Sung-Bum Han;Moon-Ki Park;Seung-Koo Song
    • Journal of Environmental Science International
    • /
    • v.2 no.4
    • /
    • pp.311-316
    • /
    • 1993
  • Methane production from grain dust was studied using a 3 L laboratory-scale anaerobic plug flow digester. The digester was operated at; temperature of 35, 45, and 55$^{\circ}C$; hydraulic retention time(HRT) of 6 and 12 days; and influent concentration($S_o$) of 7.8 and 9.0 % total solids(%TS). With ten different operation conditions, this study showed the significant effects of temperature, hydraulic retention time, and influent concentration on methane production. The highest methane-production rate achieved was 1.903 (L methane) /(L digester)(day) at 55$^{\circ}C$, 6 days HRT, and $S_0$ of 7.8 %TS. A total of 3.767 L of biogas per day with a methane content of 50.57 % was obtained from this condition. The ultimate methane yield($B_0$) was found to be a function of temperature and influent concentration, and was described as : $B_0$ = 0.02907T-0.1263-0.00297(T-10)(%TS), where TS is the total solids in the liquid effluent, and T is temperature($^{\circ}C$). Our results showed that thermophilic condition is better than mesophilic for grain dust stabilization in an anaerobic plug flow digester.

  • PDF