• 제목/요약/키워드: hydraulic gradient

검색결과 202건 처리시간 0.022초

암반대수층 지하수 인공함양 시험에 대한 열-수리 모델링 (Hydro-thermal Numerical Simulation for an Artificial Recharge Test in a Fractured Rock Aquifer)

  • 박대희;구민호;김용철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권1호
    • /
    • pp.65-75
    • /
    • 2015
  • An artificial recharge test aimed at investigating transport characteristics of the injected water plume in a fractured rock aquifer was conducted. The test used an injection well for injecting tap water whose temperature and electrical conductivity were different from the groundwater. Temporal and depth-wise variation of temperature and electrical conductivity was monitored in both the injection well and a nearby observation well. A highly permeable fracture zone acting as the major pathway of groundwater flow was distinctively revealed in the monitoring data. A finite element subsurface flow and transport simulator (FEFLOW) was used to investigate sensitivity of the transport process to associated aquifer parameters. Simulated results showed that aperture thickness of the fracture and the hydraulic gradient of groundwater highly affected spatio-temporal variation of temperature and electrical conductivity of the injected water plume. The study suggests that artificial recharge of colder water in a fractured rock aquifer could create a thermal plume persistent over a long period of time depending on hydro-thermal properties of the aquifer as well as the amount of injected water.

실내 및 현장시험에 의한 제강 슬래그의 투수성 고찰 (Considerations of Permeability of Converter Slag by Laboratory and In-situ Tests)

  • 이문수;이광찬
    • 한국농공학회지
    • /
    • 제43권5호
    • /
    • pp.93-105
    • /
    • 2001
  • The permeability of converter slag, replacing material of sand mat on improving soft clay foundation, was evaluated in the laboratory as well as in situ test. Effects of grain size, flow water time and aging were investigated using sea and fresh water Converter slag which has a grain size less than 10mm were submerged with fresh water and sea water. In fresh water, the coefficients of permeability in samples A and B were measured as 4.50${\times}$10$^{-2}$ cm per second and 1.20${\times}$10$^{-1}$ cm per second, respectively while as 1.88$\times$10$^{-2}$ cm per second and 3.86$\times$10$^{-1}$ cm per second in sea water. The condition of turbulent flow may exit and was experimentally certified based on the relationship of hydraulic gradient and seepage velocity. After 180 days in using sea water, the coefficients of permeability of samples A and B decreased ten times smaller than those initial values, and after that time continually decreased as for till 360 days. Finally, filling with voids in high-calcium quicklime(CaO) may result in the reduction of coefficient of permeability. In-situ coefficient of permeability however was Practically satisfactory.

  • PDF

Interfacial Friction Factors for Air-Water Co-current Stratified Flow in Inclined Channels

  • Choi, Ki-Yong;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.481-486
    • /
    • 1997
  • The interfacial shear stress is experimentally investigated for co-current air-water stratified flow in inclined rectangular channels having a length of 1854mm, width of 120mm and height of 40mm at almost atmospheric pressure. Experiments are carried out in several inclinations from $0^{\circ}\;up\;to\;10^{\circ}$. The local film thickness and the wave height are measured at three locations, i.e., L/H = 8,23, and 40. According to the inclination angle, the experimental data are categorized into two groups; nearly horizontal data group ($0^{\circ}\;{\leq}\;{\theta}\;{\leq}\;0.7^{\circ}$), and inclined channel data group ($0.7^{\circ}\;{\leq}\;{\theta}\;{\leq}\;10^{\circ}$). Experimental observations for nearly horizontal data group show that the flow is not fully developed due to the water level gradient and the hydraulic jump within the channel. For the inclined channel data group, a dimensionless wave height, $\Delta$h/h, is empirically correlated in terms of $Re_{G}$ and h/H. A modified root-mean-square wave height is proposed to consider the effects of the interfacial and wave propagation velocities. It is found that an equivalent roughness has a linear relationship with the modified root-mean-square wave height and its relationship is independent of the inclination.

  • PDF

흙-토목섬유 Interface 특성에 관한 연구 (A Study on the Characteristics of the Soil-Geotextile Interface)

  • 고홍석;고남영;홍순영
    • 한국농공학회지
    • /
    • 제33권2호
    • /
    • pp.82-93
    • /
    • 1991
  • The objective of this paper is to show that the soil-geotextile interaction needs to he addressed in addition to the usual tensile and modulus properties when the geotextile is being designed for a specific application. The soil-geotextile interaction can be directly assessed by standard direct shear test. The data presented here show that the shear strength paramaters describing the soil-geotextile interface can he greatly influenced by the type of the geotextile. In this investigation, we examined nine different geotextiles of varying construction and surface textures with two standard soil, under five loading conditions, and compared the shear strength and the frictional resistance with the corresponding values of soil itself The following conclusions were drawned from this study. 1. The shear stress-strain curve shows that there are the residual shear stresses at the soil-geotextile interface. Because of the hydraulic gradient between the soil and the geotextile, the excessive pore water can migrate into the geotextile and among the filaments and dissipate through the soil-geotextile interface. 2. The shear strength of the soil-geotextile interface is affected by the moisture content of the soil. At moisture content lower than the optimum water content of the Proctor compaction test, the shear strength of the soil-geotextile interface is greater. 3. The type and surface roughness of the geotextile have the greatest influence on the interface friction angle between the soil and the geotextile.

  • PDF

Feasibility of Streaming Potential Signal on Estimation of Solute Transport Characteristics

  • Kabir, Mohammad Lutful;Ji, Sung- Hoon;Lee, Jin-Yong;Koh, Yong- Kwon
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권2호
    • /
    • pp.41-46
    • /
    • 2015
  • The drag of the excess charge in an electrical double layer at the solid fluid interface due to water flow induces the streaming current, i.e., the streaming potential (SP). Here we introduce a sandbox experiment to study this hydroelectric coupling in case of a tracer test. An acrylic tank was filled up with homogeneous sand as a sand aquifer, and the upstream and downstream reservoirs were connected to the sand aquifer to control the hydraulic gradient. Under a steady-state water flow condition, a tracer test was performed in the sandbox with the help of peristaltic pump, and tracer samples were collected from the same interval of five screened wells in the sandbox. During the tracer test, SP signals resulting from the distribution of 20 nonpolarizable electrodes were measured at the top of the tank by a multichannel meter. The results showed that there were changes in the observed SP after injection of tracer, which indicated that the SP was likely to be related to the solute transport.

Stability analysis of slopes under groundwater seepage and application of charts for optimization of drainage design

  • Deng, Dong-ping;Lia, Liang;Zhao, Lian-heng
    • Geomechanics and Engineering
    • /
    • 제17권2호
    • /
    • pp.181-194
    • /
    • 2019
  • Due to the seepage of groundwater, the resisting force of slopes decreases and the sliding force increases, resulting in significantly reduced slope stability. The instability of most natural slopes is closely related to the influence of groundwater. Therefore, it is important to study slope stability under groundwater seepage conditions. Thus, using a simplified seepage model of groundwater combined with the analysis of stresses on the slip surface, the limit equilibrium (LE) analytical solutions for two- and three-dimensional slope stability under groundwater seepage are deduced in this work. Meanwhile, the general nonlinear Mohr-Coulomb (M-C) strength criterion is adopted to describe the shear failure of a slope. By comparing the results with the traditional LE methods on slope examples, the feasibility of the proposed method is verified. In contrast to traditional LE methods, the proposed method is more suitable for analyzing slope stability under complex conditions. In addition, to facilitate the optimization of drainage design in the slope, stability charts are drawn for slopes with different groundwater tables. Furthermore, the study concluded that: (1) when the hydraulic gradient of groundwater is small, the effect on slope stability is also small for a change in the groundwater table; and (2) compared with a slope without a groundwater table, a slope with a groundwater table has a larger failure range under groundwater seepage.

하천제방의 비정상침투해석을 위한 무차원 설계홍수파형에 관한 연구 (A Study on the Dimensionless Flood Waves for the Unsteady Seepage Analysis of the Levees)

  • 전세진;권경준;안원식
    • 한국방재학회 논문집
    • /
    • 제9권4호
    • /
    • pp.81-89
    • /
    • 2009
  • 제방을 설계하거나 기존제방을 보강하기 위해서는 침투해석이 필요하다. 미국, 유럽 등과 같이 대규모하천이 대부분인 외국에서는 댐에서와 같이 정상침투해석을 하고 있으나 우리나라와 일본하천의 경우는 홍수지속시간이 짧아 설계홍수파형을 정상상태로 해석할 경우에는 과대한 외력을 주게되므로 시간에 따른 수위변화를 고려한 비정상 침투해석을 하여야한다. 이 경우 하천수위와 지속시간에 대한 홍수파형이 필요하나 국내에서는 명확한 기준이나 지침이 없다. 본 연구에서는 비정상침투해석에 사용되는 설계홍수파형을 유도하였다. 수위자료가 양호한 낙동강 수계 진동 등 5개 수위관측지점의 과거 주요홍수에 대해 지속시간별 홍수위를 조사하여 무차원화를 시켰다. 그리고 통계적.확률적 처리를 통하여 무차원 설계홍수파형을 작성하였다. 작성된 홍수파형의 적정성은 과거 발생한 원홍수사상과 금회 유도한 설계홍수파형을 이용하여 침투해석을 시행하고 일본의 방법과 비교해서 적정성을 분석하였다. 동수경사법과 한계유속법에서 오차는 각각 진동 $0{\sim}0.7%,\;0{\sim}0.7%$, 현풍 $1.6{\sim}4.0%$, $1.7{\sim}4.1%$, 왜관 $0.6{\sim}3.6%$, $0.6{\sim}3.7%$, 낙동 $2.0{\sim}8.1%$, $2.0{\sim}8.1%$, 정암 $1.2{\sim}9.8%$, $1.3{\sim}9.9%$로 나타났다. 상관성($R^2$)은 $0.983{\sim}0.999$ 정도로 매우 상관성이 높게 나타났으며, 일본의 방법보다 합리적이며, 실무에 적용이 가능한 것으로 판단된다.

도수로터널 주변 지역의 지하수 유동성 단열 규명 (Identification of the Transmissive Fractures in the Vicinity of waterway Tunnel)

  • 이병대;이인호;추창오;함세영;성익환;황세호
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권3호
    • /
    • pp.33-44
    • /
    • 2002
  • 도수로터널 주변 지역의 대수층에 대한 유동성 단열을 규명하기 위하여 야외시험이 실시되었다. 단열들에 대한 정보를 얻기 위하여 지표 지질조사 지질구조조사 및 초음파주사검층을 실시하였다. 지표에서의 단열발달은 퇴적암의 층리면과 층리절리 및 화강암류의 판상절리와 같은 저각의 경사를 가지는 부분과 75$^{\circ}$ 이상의 고각의 경사를 가지는 부분의 두 개의 뚜렷한 단열군으로 형성되어 있다. 층리절리와 판상절리의 평균 주향과 경사는 각각 N70-80$^{\circ}$W.25$^{\circ}$SW, N35$^{\circ}$W.12$^{\circ}$NE이다. 고각의 절리들은 퇴적암 지역에서는 N80$^{\circ}$W.70-85$^{\circ}$SW와 N$10^{\circ}$E.85$^{\circ}$SE 두 방향의 단열조가 우세하며, 화산암 및 화강암 지역은 N40-50$^{\circ}$.E 85$^{\circ}$SE/85$^{\circ}$NE, N70$^{\circ}$E.80$^{\circ}$SE, 그리고 N70-75$^{\circ}$W.80$^{\circ}$SW 방향의 단열조가 우세하게 발달한다. 초음파주사검층에 의하여 얻어진 시추공내의 단열들은 N60-80$^{\circ}$W.20-45$^{\circ}$SW, N10-35$^{\circ}$E.64-83$^{\circ}$SE, N40-65$^{\circ}$E.60-85$^{\circ}$SE, N70$^{\circ}$E.80$^{\circ}$SE, N60-80$^{\circ}$W.45-85SE/SW의 단열군들이 우세하다. 공내 수리전도도의 수직적인 분포를 파악하기 위하여 정압주입시험을 실시하였다. 계산된 수리전도도는 3.363E-10 m/sec 에서 2.731E-6 m/sec의 범위로서 최대값과 최소값은 4차수(four order)의 차이를 보였다. 단열대의 분포 특성을 파악하기 위하여 지구물리검층을 실시하였고, 각 시험에 의해 획득된 결과들과의 비교를 통하여 유동성이 높은 단열들이 규명되었다. 온도검층은 유동성 단열과 일반적인 단열들을 구별하는 좋은 지시자로 나타났다. 그 결과, N70-80$^{\circ}$W.60-85$^{\circ}$NE/SW, N75-80$^{\circ}$W.25-30$^{\circ}$SW, N50-64$^{\circ}$W.60-85$^{\circ}$NE, N35-45$^{\circ}$E.65-75$^{\circ}$SE, 그리고 N65-72$^{\circ}$E.80$^{\circ}$SE/60$^{\circ}$NW의 단열들이 연구지역의 지하수 흐름을 지배하는 뚜렷한 유동성 단열로 규명되었다.

지하수 오염 가능성 평가 -수리지질 및 부지특성 조사와 경험적 평가 방법을 이용한 지하수 요염 가능성- (An Assessment of Groundwater Pollution Potential of a Proposed Petrochemical Plant Site in Ulsan, South Korea Hydrogeologic and site characterization and groundwater pollution potential by utilizing several empirical assessment methodologies)

  • 한정상;한규상;이영동;유대호
    • 자원환경지질
    • /
    • 제23권4호
    • /
    • pp.425-452
    • /
    • 1990
  • 지하수 환경의 오염 가능성에 대한 정량적인 전산분석을 실시하기 이전 단계로 경험적인 평가방법을 이용하여 조사대상 지역 지하수환경의 오염 가능성을 광범위한 수리지질 및 수리분산 실험을 실시하여 평가하였다. 그 결과 최상위 대수층은 포화 비고결 퇴적물과 풍화대 및 수리적으로 연결성이 양호한 상부 파쇄암으로 구성되어 있다. 최상위 대수층의 대표적인 수리전도도는 $2.88{\times}10^{-6}m/s$, 저유계수(비산출률)은 0.09, 지하수의 주흐름 경로에서 다시 안 유속은 0.011m/d, 비반응 오염 용질의 공극유속은 0.12m/d, 지하수의 동수구배는 4.6%이다. 취득한 제반 수리지질 자료를 이용하여 조사대상 지역의 자하수환경 오염 가능성을 경험적인 평가법으로 평가한 바, 1) DRASTIC 분석 결과에 의하면, 본 지역은 "지하수 오염 가능성에 취약성이 희박하거나, 오염에 민감하지 않은 지역"으로 나타났으며, 2) Legrand 수치법 분석법을 이용하여 입지 적합성과 오염 가능성을 평가한 바, 본 지역은 "B" grade에 해당하는 "오염 가능성이 없기 때문에 대체적으로 입지로 적합하나, 부분적으로 적합지 않을 수도 있는 지역"으로 분류되었고, 3) 폐기물-토양 입지 연관성 행열 평가법에 의하면, 본 부지는 8군에 속하는 것으로 평가되었다.

  • PDF

지하수위, 토양수분함량 및 수질변화를 활용한 습윤화 지역의 배수시설 효과 평가 (Analysis of the Effects of Drainage Systems in Wetlands Based on Changes in Groundwater Level, Soil Moisture Content, and Water Quality)

  • 김창훈;류정아;김덕근;김규범
    • 지질공학
    • /
    • 제26권2호
    • /
    • pp.251-260
    • /
    • 2016
  • 댐 저수지의 높은 수위와 댐 외부 지역의 지하수위간의 수두 차이는 지질 방벽을 통한 물의 흐름을 발생시킨다. 이로 인하여 발생한 유역 외 지역의 얕은 지하수위는 토양 습윤화를 초래하여 토지이용에 제약을 가져온다. 본 연구에서는 습윤화가 진행된 소유역내에 지하 1~1.5 m 심도에서 유공관 등의 배수시설을 설치한 후 그 효과를 분석하였다. 배수시설 설치 이전에 비하여 지하수 관측정에서의 수위는 1 m 이상 하강한 것으로 나타났으며, 저수지와 인접한 골짜기 상류(W1 지점)의 경우에는 2m 이상 하강하여 지하수의 빠른 배출에 의한 효과가 발생하였다. 또한, 지역 내 토양수분함량 및 그 표준편차도 감소하여 배수시설에 의한 지하수위 하강이 토양 습윤화를 억제한 것으로 분석되었다. 댐의 설계 시에는 지형지리적 특성을 고려하여 수두 차이에 의한 외부 지역으로의 누수 현상 예측 및 관련 대책을 수립해 나가야 한다.