• 제목/요약/키워드: hydraulic effect

검색결과 1,320건 처리시간 0.025초

유압 브레이커(Hydraulic breaker)의 고장분석을 통한 수명분석 연구 (A Study About Reliability Analysis of Hydraulic Breakers through Failure Mode Effect Analysis)

  • 하호진;김광섭
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권3호
    • /
    • pp.177-193
    • /
    • 2009
  • Hydraulic breakers, the attachment devices of the excavators, refer to a machine that converts back and forth motions of pistons into energies to break objects down finely. As the use of hydraulic breakers has been steadily increasing world-wide, consumers have become more interested in not just the quality of hydraulic breakers but their reliability. This study show functions and usages of several main parts on hydraulic breakers. In addition, based on the effect of action of hydraulic breakers, FMEA was performed to figure out the major causes and manifestations of malfunctioning. As above mentioned, we analyzed reliability of hydraulic breakers by models, and the data that had been used for the analyses were obtained from malfunctioning data in the field.

  • PDF

Influence of size and location of a pre-existing fracture on hydraulic fracture propagation path

  • Bo, Zhang;Yao, Li;Xue Y., Yang;Shu C., Li;Chao, Wei;Juan, Songa
    • Geomechanics and Engineering
    • /
    • 제32권3호
    • /
    • pp.321-333
    • /
    • 2023
  • Rock masses often contain natural fractures of varying sizes, and the size of the natural fractures may affect the propagation of hydraulic fractures. We conduct a series of triaxial hydraulic fracturing tests to investigate the effect of the pre-existing fracture size a on hydraulic fracture propagation. Experimental results show that the pre-existing fracture size impacts hydraulic fracture propagation. As the pre-existing fracture size increases, the hydraulic fracture propagates towards the pre-existing fracture tips, evidenced by the decreased distance between the final hydraulic fracture and the pre-existing fracture tips. Furthermore, the attracting effect of pre-existing fracture tips increases when the distance between the wellbore and the pre-existing fracture is short (L/D=2 or 4 in this study). With increased distance between the wellbore and the pre-existing fracture (L/D=6 in this study), the hydraulic fracture propagates to the middle of the pre-existing fracture rather than the tips, as the attracting effect of the pre-existing fracture diminishes.

음향시뮬레이션을 이용한 수차 발전기소음의 저감효과 분석 (Analysis on Reduction Effect of Hydraulic Turbine Dynamo Noise using Acoustic Simulation)

  • 정은정;주덕훈;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.248-252
    • /
    • 2007
  • As Waterpower Generation generates electricity using the difference of altitude of water, also let the turbine revolves through water pipe, at this time the revolving turbine causes exceedingly huge noise. Accordingly, not only those workers in the hydraulic turbine dynamo room are suffering the difficulties in mutual communication, but also those workers in the adjacent office are enduring the obstruction to the business due to the noise. Therefore, this Study has analyzed the reduction effect on the noise of hydraulic turbine dynamo room utilizing computer simulation, through the preceding research with the optimized model for architectural acoustic factor of the hydraulic turbine dynamo room. It is considered that such research result could be applied as the useful material for improvement of acoustic performance and noise-reduction effect at other similar hydraulic turbine dynamo room in the future.

  • PDF

정수지내 사류지역이 수리학적 효율에 미치는 영향 연구 (The Effect of Dead Zone on Hydraulic Efficiency in Clearwell)

  • 이승재;신은허;김성훈;박희경
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.177-185
    • /
    • 2007
  • Hydraulic efficiency($T_{10}/T$) in clearwell is often estimated by L/W ratio. However, this estimation is not accurate because other factors which give an effect on hydraulic efficiency such as shape of basin, diffuser wall and intra-basin is ignored. Therefore, in this research, hydraulic efficiency is predicted by the quantitative analysis of dead zone using CFD simulation in a pilot scale clearwell. The results show that the reason why higher L/W ratio increase the hydraulic efficiency is to decrease the dead zone of linear region which is located between baffles. Diffuser wall or intra-basin also affects on hydraulic efficiency with this process. Also, we conclude that hydraulic efficiency can not be reached to 0.8 or higher.

유체 봉입 마운트의 동적 특성화를 위한 집중질량 요소를 갖는 기계적 모형의 문제점 파악과 실험 방법 개선을 통한 수력학적 모형의 타당성 확인 (A Study on Shortcomings of Mechanical Model with Lumped Mass for Dynamic Characterization of Hydraulic Mounts and Confirmation of Hydraulic Model by Improvement of Experimentations)

  • 배만석;이준화;김광준
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.393-399
    • /
    • 2003
  • Hydraulic mounts show strong1y frequency-dependent stiffness and damping characteristics in low frequency range, which result from so called inertia track dynamics. A lumped mass has been incorporated in several mechanical models of the literature to take the inertia effect of the fluid in the track into consideration. Although complex s%illness by the mechanical model showed good agreements with the measured values, there exists a critical pitfall. In this paper, the shortcomings of mechanical models with lumped mass for hydraulic founts are clearly identified by illustrating actual measurements of the stiffness parameters for a hydraulic mount. It is conclusively discussed that the inertia effect of the fluid flow through the circular track is significant but latent. As an alternative to the mechanical model, a hydraulic model is claimed to be used for further dynamic analysis of engine/mount system or whole car system.

차량용 유압 클러치시스템의 댐퍼실린더 특성해석 (Characteristic Analysis of the Damper Cylinder for the Automotive Hydraulic Clutch System)

  • 이춘태
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.151-158
    • /
    • 2008
  • The clutch system is a subcomponent of the transmission that is designed to engage and disengage power flow between the engine and the transmission. Recently, the engine power of automobile has been continuously increased because of customer's demand for the bigger one. As the engine power is increased, the vibration transmitted to the hydraulic clutch operating system has been increased. Therefore the demand for the reduction of clutch pedal vibration during the operation has been increased. This paper describes the pressure pulsation reduction characteristics of the damper cylinder which is applied to the hydraulic clutch operating system. And the purpose of this study is to propose an analysis model and investigate the effect of the design variable variations for the hydraulic clutch system. Especially, we studied the effect of damper cylinder parameter variations on the hydraulic clutch system performance.

댐저수지의 남조류 수화에 대한 간헐식 폭기장치의 효과 (Effect of Hydraulic-Gun-Aerators on Cyanobacterial Bloom in a Dam Reservoir)

  • 이정호
    • ALGAE
    • /
    • 제19권1호
    • /
    • pp.23-30
    • /
    • 2004
  • The purpose of this study is to assess the effects that hydraulic-gun-aerators have on cyanobactedial bloom in Sayeon Dam Reservoir in Ulsan City, Korea. A total of nine hydraulic-gun-aerators are in operation at the reservoir withe 100 m spacing between each aerator to control severe cyanobacterial bloom in the dam reservoir. The field studies were performed an total four times at two sampling stations in the reservoir from July to August in 2001. The standing crops of phytoplankton did not changed significantly by the operation. The cell concentration of the cyanobacteria at the surface layer were reduced about 10%, which is a poor result for the dispersing cyandobacteria deeper into the water. The average surface temperature during the study was reduced by 2.0$^{\circ}C$ by the hydraulic-gun-aerators. The effect of the operation on the vertical distribution of DO concentration was clear. However, the hydraulic-gun-aerators were not expected to have an effect in the lowest layer of the hypolimnion. In the study, it was proposed that installation distance between each hydraulic-gun-aerator would be proper when they are apart about 120 m based on DO depth profiles.

수리실험을 이용한 강변저류지의 홍수조절효과 분석 (Analysis of Flood Reduction Effect of Washland using Hydraulic Experiment)

  • 김덕길;이임열;이창원;강나래;이종소;김형수
    • 한국습지학회지
    • /
    • 제13권2호
    • /
    • pp.307-317
    • /
    • 2011
  • 최근에 홍수조절 기능으로써 강변저류지 조성에 대한 관심이 증가하고 있다. 따라서 본 연구에서는 수리실험을 이용한 강변저류지의 홍수조절효과를 분석하였다. 강변저류지의 홍수조절효과를 분석하기 위해 개수로 실험장치를 이용하였으며, 측방구조물로는 횡월류 위어를 이용하였다. 수리실험 결과 횡월류 위어 설치 지점을 기준으로 평균유속과 유량이 감소하는 것으로 나타났다. 또한 수리실험 결과의 검토를 위해 HEC-RAS 모형을 이용하여 실험결과와 모형의 모의 결과를 비교하였다. 그 결과 수리실험 결과와 모형의 모의 결과가 유사한 것으로 분석되었다.

서보모터를 이용한 유압 하이브리드식 사출성형기의 공정시간 및 절전효과에 관한 연구 (A Study on Cycle Time and Power Saving Effect of a Hydraulic Hybrid Injection Molding Machine using a Servo Motor)

  • 윤홍식;김성동
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.15-25
    • /
    • 2020
  • The cycle time and power saving effect of a hydraulic hybrid injection molding machine using a servo motor are considered in this paper. In order to verify control characteristics, such as pressure and speed, experiments were performed with the hydraulic hybrid injection molding machine, clamping force of 110 ton. The power consumption and production cycle time of a conventional hydraulic injection molding machine were measured to compare its performances with the hydraulic hybrid injection molding machine. An injection molding machine with a clamping force of 1300 ton was used as the conventional machine, the hybrid machine was implemented by replacing its induction motors with servo motors. In the remodeled hybrid machine, experiments were performed to investigate how the displacement of the mold clamping pump affects the power consumption and production cycle time. The results showed that the production cycle time of the hybrid injection molding is similar to a conventional hydraulic injection molding machine but with a significant energy saving of about 40%.

TOUGH2를 이용한 폐쇄형 지열펌프 시스템의 3차원 모델링 연구 (3 Dimensional Numerical Simulation for the Closed Loop Heat Pump System Using TOUGH2)

  • 김성균;배광옥;이강근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.36-39
    • /
    • 2006
  • To evaluate the effect of groundwater flow on the outlet temperature of a geothermal heat pump, 3 dimensional numerical simulations are performed considering both groundwater flow and pipe flow in the U-tube using TOUGHS, The present study involved the following 4 simulation cases (1) no groundwater flow, (2) slow groundwater flow (hydraulic conductivity: $1.0{\times}10^{-9}m/s)$, (3) fast groundwater flow (hydraulic conductivity, $1.0{\times}10^{-7}m/s$), and (4) groundwater flow varying with the depth (hydraulic conductivity: $1.0{\times}10^{-7}-1.0{\times}10^{-10}m/s$). The effect of groundwater flow on the outlet temperature is significant where hydraulic conductivity of aquifer is $1.0{\times}10^{-7}m/s$. Where hydraulic conductivity of aquifer is $1.0{\times}10^{-10}m/s$, however, that effect is negligible.

  • PDF