• Title/Summary/Keyword: hybrid resin

Search Result 330, Processing Time 0.025 seconds

Carbon Nano Tube Dispersion Evaluation in B-stage Resin Films (B-stage 레진 필름의 카본나노튜브 분산도 평가 및 제조공정 최적화)

  • Oh, Young-Seok;Park, Tea-Hoon;Byun, Joon-Hyung;Yi, Jin-Woo;Kim, Byung-Sun;Joe, Chee-Ryong
    • Composites Research
    • /
    • v.29 no.6
    • /
    • pp.353-357
    • /
    • 2016
  • An appropriate way to fabricate a hybrid composite containing evenly dispersed carbon nano tubes(CNTs) is to stacking B-stage resin films that contain evenly dispersed CNTs and various reinforcing fiber layers alternatively. In the present study, B-stage resin films are manufactured via shear mixing and three-roll milling. CNT dispersion in resin via these two processes are evaluated by SEM on their fracture surfaces. For more efficient process, the dispersivities are evaluated according to the number of calendering passes. Samples are made for different number of passes during calendering, and their dispersions are evaluated via SEM fractographs as well as by measuring their electrical conductivities. Additionally, the optimal process conditions are obtained by measuring the electrical conductivity and evaluating their dispersivity of the samples prepared by gap mode and force mode.

Micro-shear bond strength of resin-modified glass ionomer and resin-based adhesives to dentin (상아질 위치에 따른 접착성 수복재의 미세전단결합강도에 관한 연구)

  • Hong, Hyun-Kyung;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.314-325
    • /
    • 2003
  • 이 연구의 목적은 수종 상아질 접착 시스템과 복합 레진 및 resin-modified glass ionomer를 상아질 표면에 접착하여 재료 및 상아질내 위치에 따른 미세전단결합강도를 측정, 비교하는 것이다. 상아질 접착 시스템으로는, 3-step인 Scotchbond Multi-Purpose Plus, 2-step인 Single Bond와 자가 부식형 시스템인 Clearfil SE Bond를, 1-step인 Prompt L-Pop을 사용하였다. 이와 함께 hybrid type의 복합 레진인 Clearfil AP-X와 2250을 사용하였으며 resin-modified glass ionomer로는 Fuji II LC를 사용하였다. 상악 소구치를 치아의 근원심 중앙부를 절단하여 상아질면을 노출시켰다. 5개 실험군으로 분류하고 상아질면을 위치에 따라 치관부의 occlusal $\frac{1}{3}$, middle $\frac{1}{3}$, cervical $\frac{1}{3}$과 치근부로 구분지어 시편을 부착하였다. 미세전단결합강도측정는 Universal testing machine(EZ-test; Shimadzu, Japan)에서 측정하였다. Occlusal 1/3부위에서는 SE가 가장 높은 값을, SM과 SB간에는 유의차가 없었으며, PL, GI순으로, Middle 1/3부위에서는 $SM{\;}{\geq}{\;}SE{\;}{\geq}{\;}SB{\;}{\geq}{\;}PL{\;}{\geq}{\;}GI$순으로, cervical 1/3부위에서는 SM, SE, SB간에 유의차가 없었다. Root dentin에서는 SM이 가장 높은 값을 보였으며 SE, PL, GI간에 유의차가 없었다. SE만이 치관부 상아질에 비해 치근부에서 유의할만한 결합강도의 감소를 나타냈다(p<0.05). GI는 치관부 상아질에서는 다른 군에 비해 유의성 있게 낮은 결합강도를 보였으나 치근부에서는 SE, PL과 유의차가 없었다.

A COMPARISON OF GLASS IONOMER vs RESIN RESTORATION IN MICROLEAKAGE PATTERN OF PRIMARY AND PERMANENT TEETH (유치와 영구치에 수복된 레진과 글라스 아이오노머 수복물의 미세누출 양상에 관한 비교연구)

  • Jun, Kyung-Hyun;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.47-61
    • /
    • 1998
  • The purpose of this study was to compare the microleakage pattern of glass ionomer with resin restoration in microleakage pattern of primary and permanent teeth. Microscopical observation of interface between tooth structure and restoration was also performed. 80 and 8 sound molar teeth were used for the microleakage test and SEM study respectively. Data were analyzed statistically using ANOVA test and/or t-Test. The results of the present study were as follows: 1. According to the result of microleakage pattern between primary and permanent tooth, primary tooth generally showed more micro leakage than permanent tooth in all groups (p<.05). 2. In the resin-filled groups, occlusal margin was shown to have more microleakage than gingival margin(p<.05). Whereas the glass ionomer-filled groups showed no statistically significant differences between them(p>.05). 3. No statistically significant differences in microleakage could be found between two different resin groups(p>.05), while Fuji II LC group showed less microleakage than Ketac-Fil group(p>.05). 4. The various type hybrid layer was evident under SEM in resin-filled groups both in primary and permanent teeth with generally thicker layer in primary group. Among glass-ionomer group, Fuji II LC group showed more intact adhesion to tooth surface than Ketac-Fil group

  • PDF

On the Development of Hybrid Composites with Non-Woven Tissue (부직포를 이용한 하이브리드 복합재료의 개발)

  • Lee Seung-Hwan;Noguchi Hiroshi;Cheong Seong-Kyun
    • Composites Research
    • /
    • v.19 no.2
    • /
    • pp.20-27
    • /
    • 2006
  • The hybrid composite materials with non-woven tissue (NWT) was developed to improve the mechanical properties of conventional FRP composite materials. The hybrid prepreg with NWT consists of FRP prepreg and NWT prepreg. The NWT prepreg consists of NWT and polymer resin. The NWT has short fibers, discretely distributed with in-plane random orientation fibers. The purposes of this study of hybrid prepreg with NWT are (i) to increase the interlaminar properties(the fracture toughness and strength), (ii) to improve the mechanical properties and reliability, while maintaining a low cost, (iii) to introduce a tough and strong interlayer at critical positions to be required of strength in the laminate. To accomplish the above purposes, a production technique to decrease voids in NWT layers was proposed in this paper. The interlaminar failure characteristics of laminated composite materials was tremendously improved by hybrid concept with NWT.

Strengthening of C/C Composites through Ceramer Matrix

  • Dhakate, S.R.;Mathur, R.B.;Dhami, T.L.
    • Carbon letters
    • /
    • v.5 no.4
    • /
    • pp.159-163
    • /
    • 2004
  • The polymer-ceramic hybrid, known as 'ceramer', was synthesized by a sol-gel process by incorporating different amount of alkoxide as source of silicon in resorcinol-formaldehyde in presence of basic catalyst to get different percentage of silicon in ultimate carbonized composites. FTIR of the ceramer confirms that it is a network of Si-O-Si, Si-O-$CH_2$ and Si-OH type groups linked with benzene ring. Different amount of silicon in the ceramer exhibits varying temperature of thermal stability and lower coefficient of thermal expansion as compared to pure resorcinol-formaldehyde resin. The lower value of CTE in ceramer is due to existence of silica and resorcinol -formaldehyde in co-continuous phase. Unidirectional composites prepared with ceramer matrix and high-strength carbon fibers show lower value of flexural strength at polymer stage as compared to those prepared with resorcinol-formaldehyde resin. However, after heat treatment to $1450^{\circ}C$, the ceramer matrix composites show large improvement in the mechanical properties, i.e. with 7% silicon in the ceramer, the flexural strength is enhanced by 100% and flexural modulus value by 40% as compared to that of pure resorcinol-formaldehyde resin matrix composites.

  • PDF

Development of Hybrid RIM Mold to Form Outfit-part for Prototype-cars (시작차용 의장부품 성형을 위한 하이브리드 림 몰드 개발)

  • Yang, Hwa-Jun;Hwang, Po-Jung;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.75-83
    • /
    • 2001
  • RIM(Reaction Injection Molding) is a widely used method to manufacture middle-large size outfit-part for a prototype car. The main advantage of RIM is the capability of manufacturing a small number of prototype parts with less cost and lead time than injection molding which is the most popular method to manufacture plastic parts. Generally, epoxy resin and RTV(Room Temperature Vulcanization) silicon are used as mold materials for RIM, and the selection of mold materials is usually depended upon the industrial environment of manufactures and it decides overall mold making process and part quality. This paper suggests a new mold making process by consolidating the advantages of epoxy resin and RTV silicon based RIM mold to enhance the parts quality while reducing the manufacturing cost and time and shows the competitiveness of the suggested process compared with conventional methods.

  • PDF

Mechanical properties of demountable shear connectors under different confined conditions for reusable hybrid decks

  • Kavour, Florentia;Christoforidou, Angeliki;Pavlovic, Marko;Veljkovic, Milan
    • Steel and Composite Structures
    • /
    • v.43 no.4
    • /
    • pp.419-429
    • /
    • 2022
  • In response to the sustainability requirements set in the EU Commission's "Green Deal" towards reduction of the greenhouse gas emissions, it is estimated that the structural design for deconstruction is going to contribute considerably to the sustainable development of the built environment. The demountability of multi-material structural systems basically depends on the shear connectors used in the structural system. This paper focuses on a type of demountable injected shear connector with an injected steel-reinforced resin (iSRR) which consists of spherical steel particles embedded in a resin. Its application to steel-to-concrete and steel-to-Fiber Reinforced Polymer (FRP) decks is presented along with its benefits. In parallel, an overview of the experimental and numerical research on the evaluation of the mechanical properties of the demountable bolted connectors with iSRR is discussed. Last, detailed finite element (FE) models and a parametric study are performed to quantify the confinement level of the SRR material influenced by the oversized hole diameter.

Synthesis, Characterization and Curing Studies of Thermosetting Epoxy Resin with Amines

  • Lakshmi, B.;Shivananda, K.N.;Mahendra, K.N.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2272-2278
    • /
    • 2010
  • A new hybrid thermosetting maleimido epoxy compound 4-(N-maleimidophenyl) glycidylether (N-MPGE) is prepared by reacting N-(4-hydroxyphenyl) maleimide (HPM) with Epichlorohydrin by using benzyltrimethylammonium chloride as a catalyst. The resulting compound possesses both the oxirane ring and maleimide group. The curing reaction of these maleimidophenyl glycidylether epoxy compound (N-MPGE) with amines as curing agents such as ethylendiamine (EDA), diethylentriamine (DETA) and triethylenetetramine (TETA), aminoethylpiperazine (AEP) and isophoronediamine, IPDA), are studied. Incorporation of maleimide groups in the epichlorohydrin provides cyclic imide structure and high cross-linking density to the cured resins. The cured samples exhibited good thermal stability, excellent chemical (acid/alkali/solvent) and water absorption resistance. Morphological studies by the SEM technique further confirmed the phase homogeneity net work of the cured systems.

Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin (복합 레진에서 마무리 방법에 따른 표면 거칠기 비교)

  • Jeong, Suk-In;Oh, Nam-Sik;Lee, Myung-Hyeon;Lee, En-Jung;Cho, Jung-Hyeon;Ji, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.

Shear bond strength of dental CAD-CAM hybrid restorative materials repaired with composite resin (치과용 복합레진으로 수리된 CAD-CAM hybrid 수복물의 전단결합강도)

  • Moon, Yun-Hee;Lee, Jonghyuk;Lee, Myung-Gu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.193-202
    • /
    • 2016
  • Purpose: This study was performed in order to assess the effect of the surface treatment methods and the use of bonding agent on the shear bond strength (SBS) between the aged CAD-CAM (computer aided design-computer aided manufacturing) hybrid materials and added composite resin. Materials and methods: LAVA Ultimate (LU) and VITA ENAMIC (VE) specimens were age treated by submerging in a $37^{\circ}C$ water bath filled with artificial saliva (Xerova solution) for 30 days. The surface was ground with #220 SiC paper then the specimens were divided into 9 groups according to the combination of the surface treatment (no treatment, grinding, air abrasion with aluminum oxide, HF acid) and bonding agents (no bonding, Adper Single Bond 2, Single Bond Universal). Each group had 10 specimens. Specimens were repaired (added) using composite resin (Filtek Z250), then all the specimens were stored for 7 days in room temperature distilled water. SBS was measured and the fractured surfaces were observed with a scanning electron microscope (SEM). One-way ANOVA and Scheffe test were used for statistical analysis (${\alpha}=.05$). Results: Mostly groups with bonding agent treatment showed higher SBS than groups without bonding agent. Among the groups without bonding agent the groups with aluminum oxide treatment showed higher SBS. However there was no significant difference between groups except two subgroups within LU group, which revealed a significant increase of SBS when Single Bond Universal was used on the ground LU specimen. Conclusion: The use of bonding agent when repairing an aged LAVA Ultimate restoration is recommended.