• Title/Summary/Keyword: hybrid power generating system

Search Result 31, Processing Time 0.032 seconds

Hybrid Artificial Immune System Approach for Profit Based Unit Commitment Problem

  • Lakshmi, K.;Vasantharathna, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.959-968
    • /
    • 2013
  • This paper presents a new approach with artificial immune system algorithm to solve the profit based unit commitment problem. The objective of this work is to find the optimal generation scheduling and to maximize the profit of generation companies (Gencos) when subjected to various constraints such as power balance, spinning reserve, minimum up/down time and ramp rate limits. The proposed hybrid method is developed through adaptive search which is inspired from artificial immune system and genetic algorithm to carry out profit maximization of generation companies. The effectiveness of the proposed approach has been tested for different Gencos consists of 3, 10 and 36 generating units and the results are compared with the existing methods.

Hybrid Tension/Mobile Control of working Robot for installed Troy Cable (트로이선 가설 작업 로봇의 장력 및 이동 제어에 관한 연구)

  • Hong, Jeng-Pyo;Won, Tae-Hyun;Kim, Mun-Soo;Hong, Soon-Ill
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.455-457
    • /
    • 2007
  • The objective of this study is development of a installed working robot for a troy cable with mobile and tension system. In this paper, an approach to designing controllers for dynamic hybrid Tension/Mobile control of a installed robot for a troy wire cable is presented. Mobile control system of robot is designed based on equation of dc motor and motion for moving robot and tension control system is designed based on equation of ac servomotor for generating torque and dynamic equation of a wire cable. The control parameters is determined by simulation in independence operation of two system.

  • PDF

Development of PV/T for Performance Improvement of Photovoltaic System (태양광 발전의 성능향상을 위한 PV/T 시스템 개발)

  • Choi, Jung-Sik;Ko, Jae-Sub;Kang, Sung-Jun;Baek, Jeong-Woo;Jang, Mi-Geum;Mun, Ju-Hui;Chung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.95-96
    • /
    • 2010
  • This paper proposes photovoltaic thermal hybrid module to get the electrical and Thermal performance of building integrated photovoltaic(BIPV) system. BIPV system is decreased the system efficiency because output of PV is decreased by the thermal rising on generating. In order to improve the efficiency of BIPV module, water cooling system is applied and generated thermal is used the warm water system. Water cooling system uses the flux control algorithm considering water temperature and power loss. Electrical and thermal performance of proposed photovoltaic thermal hybrid module is confirmed through the actual experiment and herby proved the valid of this paper.

  • PDF

Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages (고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터)

  • Lee, Ji-Myeong;Lee, Dong-Chun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.

The Study of Hybrid system using FC and IPT for Railway system (철도용 연료전지 및 유도급전을 이용한 Hybrid system 연구)

  • Han, K.H.;Lee, B.S.;Park, H.J.;Kwon, S.Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.218-220
    • /
    • 2008
  • Urban air quality, including carbon-dioxide emissions, and national energy security are related issues affecting the rail industry and transportation sector as a whole. They are related by the fact that (in the United States) 97-98% of the energy for the transport sector is based on oil, and more than 60% is imported. A fuelcell locomotive combines the environmental advantages of a catenary-electric locomotive with the higher overall energy efficiency and lower infrastructure costs of a diesel-electric. Catenaryelectric locomotives, when viewed as only one component of a distributed machine that includes an electricity-generating plant and transmission lines, are the least energy-efficient locomotive type. The natural fuel for a fuelcell is hydrogen, which can be produced from many renewable energies and nuclear energy, and thus a hydrogen-fuelcell locomotive will not depend on imported oil for its energy supply. This paper proposes a base models of Hybrid fuel cell/IPT railway vehicle power system, the necessary of this research.

  • PDF

A Pre-Feasibility Test of Introducing Renewable Energy Hybrid Systems -Case Studies for 3 Off-Grid Islands- (도서지역 신·재생복합 전력시스템 보급 타당성 분석 -3개 도서지역 분석결과-)

  • Jang, HaNa;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.15 no.4
    • /
    • pp.693-712
    • /
    • 2006
  • A pre-feasibility test is done for renewable energy hybrid power systems at off~grid islands in which the current power supply is provided only by diesel generation. We apply Homer (Hybrid Optimization Model for Electric Renewables) which was developed by the National Renewable Energy Laboratory (NREL) for the analysis to identify the cost-minimizing combination of power generating facilities for the given load profiles. Chuja-Do, Geomun-Do and Youngsan-Do have been selected for our analysis considering the wind resources data of the Korea Institute of Energy Research (KIER). Information on wind speed, solar radiation and temperature is also used for the analysis. System component cost information from overseas market has been used due to the lack of domestic information. Site specific Load profile for electricity demand for those islands are reconstructed based on the partial survey results obtained form other sources. The LCOE of the least cost hybrid power systems for Chuja-Do, Geomun-Do and Youngsan-Do are $0.278/kWh, $0.234/kWh and $0.353/kWh, respectively Considering the fact that diesel generation is being subsidized at the price of $0.300/kWh by the government, first 2 cases are economically feasible for the introduction of renewable energy hybrid systems to those islands. But the third case of Youngsan-Do does not meet the criteria. The basic differences of these pre-feasibility test results are from the differences of the site specific renewable energy conditions, especially wind resources. In summary, promoting hybrid systems in the off-grid remote island should be based on the economic feasibility test results. Not all the off-grid islands are feasible for introducing this renewable energy hybrid system.

  • PDF

Influence of Grid Operation from Ullung Wind Power Plant (울릉풍력발전의 계통에 주는 영향 분석)

  • Lee, Seung-Hun;Seo, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.495-497
    • /
    • 2001
  • Ullung wind power plant is a remarkable event to get a great concern of many people, because it has been observed as a first case of combining the new large different generating sources, i. e. hybrid diesel-wind power system. This paper is dealing with the analysis of this problem and with the grid-coordination. The first endeavor of actual measurement was performed at site during October 18-21. 2000 and a part of this records is presented in this paper.

  • PDF

Development of Hybrid Device for Photovoltaic Power Generation and Heating (복합식 태양광 발전 및 난방장치 개발)

  • Lee, Dong Il;Baek, Seung Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.907-914
    • /
    • 2014
  • The objective of this study was to increase the generating efficiency of concentrated photovoltaics (CPV) by using hybrid solar tracking. Further, the proposed system was demonstrated to have the ability to extract thermal energy from a concentrated photovoltaic system by using thermal absorbers containing heat pipe, which could then be used for a heating system or hot-water supply. The average electrical efficiency was 16 during the day, and the average thermal efficiency was 62. Therefore, this system demonstrated a total efficiency (electrical thermal) of 78. All the processes, i.e., tracking of the sun, calculation of the sun's position, reinstatement of the heating device toward the east for tracking on the next day, and system shutdown, were programmed using Simulink. A parametric analysis of the heat pipe, concentration ratio, and inlet velocity was also performed in terms of the operating temperature of the CPV and the outlet temperature. The simulation and experimental results for the thermal absorber were found to be in good agreement.

The Invert for ozone generator by mixed square_wave and PWM (구형파 및 PWM 인버터 조합에 의한 오존발생용 인버터)

  • Park Noh-Sik;Park Sung-Jun;Won Tae-Hyun;Ahn Jin-Woo;Kim Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1193-1195
    • /
    • 2004
  • Ozone gas is one of the strongest oxidizing and bleaching agents which leave no residues harmful to the global environment. In recent years, the ozone generator has been widely utilized, However, it has been known that a broader application of ozone is hindered primarily because of its low efficiency of generation. Thus, it is more indispensable to improve actual system efficiency of the silent discharge type ozonizer using high frequency inverter. This paper presents a multi level resonant ozone power regulation by association of high frequency transformers and full bridge invert. And proposed resonant inverter system can generate continuous output voltage. can control linearly quantity of ozone gas. This invert that add PWM forms within square forms of output voltage about one level range. The power regulation characteristics and operating performances of silent discharge (SD)type ozone generating tube load driven by this load proposed inverter using FET modules are illustrated from a practical point of view, which can operate under stable conditions of basic level and PWM hybrid control strategy implemented DSP(2406). The effectoveness of propsed invert type ozonizer is proved by experiment results.

  • PDF

Development of Drying System using NIR and Hot Air Method (근적외선 및 열풍방식을 이용한 건조시스템 개발)

  • Ko, Jae-Sub;Choi, Jung-Sik;Kang, Sung-Jun;Baek, Jung-Woo;Jang, Mi-Geum;Moon, Ju-Hui;Chung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.589-590
    • /
    • 2010
  • The drying method that is applied in industry is mainly used hot air drying method witch is circulated heated air by generating heat from thermal source. But these methods have problems such as decreasing drying efficiency and waste of energy by low thermal efficiency. Therefore, this paper proposes high efficiency hybrid drying system using near infrared ray(NIR) drying method using halogen lamp and hot air drying method. And this paper proves validity of proposed drying system through experiment about thermal and humidity of drying system inside.

  • PDF