• Title/Summary/Keyword: hybrid flux

Search Result 246, Processing Time 0.026 seconds

Magnetic field dependence of critical current and index n in a Bi-2223/Ag superconductor tape (Bi-2223/Ag 초전도 선재에서 임계전류와 인덱스의 자계의존성)

  • Kim Jung Ho;Kim Kyu Tae;Lim Jun Hyung;Jang Seok Hern;Rho Yun Bong;Joo Jinho;Choi Seyong;Nah Wansoo;Hong Gye-Won
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.79-83
    • /
    • 2004
  • We fabricated Bi-2223/Ag superconductor tape with 55 filaments and estimated the magnetic field dependence of critical current (I$_{c}$) and index n (n) up to 30 T at 4.2 K. The I$_{c}$ and n were characterized as a function of external magnetic field parallel to the tape surface on increasing and decreasing field, using a 35 T hybrid magnet. The $I_{c}$ was estimated to be 325 A, and n was 32, 22, and 26 in the electric field range of $0.1 ∼1\mu$V/cm, 1∼10 $\mu$V/cm, and 0.1∼10 $\mu$V/cm, respectively, under self-field at 4.2 K. It was observed that $I_{c}$ was dependent on magnitude of magnetic field and it decreased exponentially as the field increased; in a parallel and increasing field, It was 128 A at 30 T which is approximately 40% of critical current in self-field. In addition, the $I_{c}$ was higher on decreasing field than that on increasing one. On the other hand, n did not significantly depend on field strength up to 30 T, nor varied on whether increasing or decreasing field; n value in 0.1∼1 $\mu$V/cm was 23.0$\pm$5.2 and 27.8$\pm$8.0 on increasing and decreasing field, respectively. The n value on decreasing magnetic field was slightly higher than that on increasing field. This hysteretic behavior of n was similar to that of$ I_{c}$, which is related to the trapped flux at the grain boundary.ary.

  • PDF

Simulation of Mixing Behavior for Dredging Plume using Puff Model (퍼프모형을 이용한 준설플륨의 혼합거동 모의)

  • Kim, Young-Do;Park, Jae-Hyeon;Lee, Man-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.10
    • /
    • pp.891-896
    • /
    • 2009
  • The puff models have been developed to simulate the advection-diffusion processes of dredging suspended solids, either alone or in combination with Eulerian models. Computational efficiency and accuracy are of prime importance in designing these hybrid approaches to simulate a pollutant discharge, and we characterize two relatively simple Lagrangian techniques in this regard: forward Gaussian puff tracking (FGPT), and backward Gaussian puff tracking (BGPT). FGPT and BGPT offer dramatic savings in computational expense, but their applicability is limited by accuracy concerns in the presence of spatially variable flow or diffusivity fields or complex no-flux or open boundary conditions. For long simulations, particle and/or puff methods can transition to an Eulerian model if appropriate, since the relative computational expense of Lagrangian methods increases with time for continuous sources. Although we focus on simple Lagrangian models that are not suitable to all environmental applications, many of the implementation and computational efficiency concerns outlined herein would also be relevant to using higher order particle and puff methods to extend the near field.

Pervaporation of binary Water/Methanol and Water/Butanol Mixtures through Zeolite 4A Membranes: Experiments and Modeling (제올라이트 4A 분리막을 이용한 물/메탄올, 물/부탄올 혼합물의 투과증발 특성 연구: 실험 및 모형)

  • Oh, Woong-Jin;Jung, Jae-Chil;Yeo, Jeong-gu;Lee, Jung Hyun;Kim, Hyunuk;Park, Young Cheol;Lee, Dong-Ho;Moon, Jong-Ho;Cho, Churl-Hee
    • Membrane Journal
    • /
    • v.27 no.6
    • /
    • pp.487-498
    • /
    • 2017
  • In this study, pervaporation performances of water/methanol and water/butanol mixture were evaluated using zeolite 4A membranes manufacutred by FINETECH by experimental works and numerical modeling. Permeation and separation characteristics, such as flux and separation factor, were analyzed by gas chromatography (TCD) and liquid nitrogen traps. Experiments have shown that water is selectively separated from a mixture of water and methanol (separation factor up to approximately 250) and water and butanol (separation factor up to approximately 1,500). Generalized Maxwell Stefan (GMS) theory was implemented to predict pervaporation behaviors of water/alcohol mixtures and diffusional coefficients of zeolite layer were obtained through parameter estimation using $MATLAB^{(R)}$ optimization toolbox. Since the pore size of zeolite 4A are much larger than kinetic diameter of water molecules and smaller than those of methanol and butanol, zeolite 4A membranes can be applied to in situ water removal process such as membrane reactors or hybrid reaction-dehydration process.

Reactive Ceramic Membrane Incorporated with Iron Oxide Nanoparticle for Fouling Control (산화철 나노입자 부착 반응성 세라믹 멤브레인의 막 오염 제어)

  • Park, Hosik;Choi, Heechul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.144-150
    • /
    • 2013
  • Hybrid ceramic membrane (HCM) processes that combined ozonation with a ceramic membrane (CM) or a reactive ceramic membrane (RM), an iron oxide nanoparticles (IONs) incorporated-CM were investigated for membrane fouling control. Alumina disc type microfiltration and ultrafiltration membranes doped with IONs by sintering method were tested under varying mass fraction of IONs. Scanning electron microscope (SEM) images showed that IONs were well-doped on the CM surface and doped IONs were approximately 50 nm in size. Change in the pure water permeability of RM was negligible compared to that of CM. These results indicate that IONs incorporation onto CM had little effect on CM performance in terms of the flux. Natural organic matter (NOM) fouling and fouling recovery patterns during HCM processes confirmed that the RM-ozonation process enhanced the destruction of NOM and reduced the extent of fouling more than the CM-ozonation process by hydroxyl radical formation in the presence of IONs on RM. In addition, analyses of NOM in the feed water and the permeate showed that the efficiency of membrane fouling control results from the NOM degradation during HCM processes; leading to removal and transformation of relatively high contents of aromatic, high molecular weight and hydrophobic NOM fractions.

Modeling and analysis of dynamic heat transfer in the cable penetration fire stop system by using a new hybrid algorithm (새로운 혼합알고리즘을 이용한 CPFS 내에서의 일어나는 동적 열전달의 수식화 및 해석)

  • Yoon En Sup;Yun Jongpil;Kwon Seong-Pil
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.44-52
    • /
    • 2003
  • In this work dynamic heat transfer in a CPFS (cable penetration fire stop) system built in the firewall of nuclear power plants is three-dimensionally investigated to develop a test-simulator that can be used to verify effectiveness of the sealant. Dynamic heat transfer in the fire stop system is formulated in a parabolic PDE (partial differential equation) subjected to a set of initial and boundary conditions. First, the PDE model is divided into two parts; one corresponding to heat transfer in the axial direction and the other corresponding to heat transfer on the vertical planes. The first PDE is converted to a series of ODEs (ordinary differential equations) at finite discrete axial points for applying the numerical method of SOR (successive over-relaxation) to the problem. The ODEs are solved by using an ODE solver In such manner, the axial heat flux can be calculated at least at the finite discrete points. After that, all the planes are separated into finite elements, where the time and spatial functions are assumed to be of orthogonal collocation state at each element. The initial condition of each finite element can be obtained from the above solution. The heat fluxes on the vertical planes are calculated by the Galerkin FEM (finite element method). The CPFS system was modeled, simulated, and analyzed here. The simulation results were illustrated in three-dimensional graphics. Through simulation, it was shown clearly that the temperature distribution was influenced very much by the number, position, and temperature of the cable stream, and that dynamic heat transfer through the cable stream was one of the most dominant factors, and that the feature of heat conduction could be understood as an unsteady-state process.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.