• 제목/요약/키워드: hybrid control technique

검색결과 227건 처리시간 0.025초

버스용 병렬형 하이브리드 동력전달계의 개발(III) 제 3 편;최적 주행 제어 알고리즘 (A Development of Parallel Type Hybrid Drivetrain System for Transit Bus Part 3 : Optimal Driving Control Algorithm)

  • 조한상;이장무;박영일
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.182-197
    • /
    • 1999
  • Described in this paper is an optimal driving control algorithm which focused on the improvement of fuel economy and the minimization of pollutant emissions in the parallel type hybrid drivertrain system for transit bus. For the energy balance among components such as engine, induction machine and buttery, the algorithm for power split ration determine is proposed. When it is implemented in the hybrid electric control unit(HECU) , using the sub-optimal method and the approximate technique , it is possible to save the memory , to shorten the calculation time, and to achieve the efficient driving actually. A Shift strategy for automated manual transmission is the other side of the driving control algorithm. It enables to select the optimal gear by using several shift maps which were predefined from the proposed method in this paper, As a results of driving simulation, it is proved that these algorithms make the hybrid drivetrain system to reduce fuel consumption and emissions considerably and to have the ability to the efficient use of battery.

  • PDF

Efficient Hybrid Carrier Based Space Vector Modulation for a Cascaded Multilevel Inverter

  • Govindaraju, C.;Baskaran, K.
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.277-284
    • /
    • 2010
  • This paper presents a novel hybrid carrier based space vector modulation for cascaded multilevel inverters. The proposed technique inherits the properties of carrier based space vector modulation and the fundamental frequency modulation strategy. The main characteristic of this modulation are the reduction of power loss, and improved harmonic performance. The carrier based space vector modulation algorithm is implemented with a TMS320F2407 digital signal processor. A Xilinx Complex Programmable Logic Device is used to develop the hybrid PWM control algorithm and it is integrated with a digital signal processor for hybrid carrier based space vector PWM generation. The inverter offers less weighted total harmonic distortion and it operates with equal electrostatic and electromagnetic stress among the power devices. The feasibility of the proposed technique is verified by spectral analysis, simulation, and experimental results.

실내환경에서의 WATM 최적화 기법 연구 (Optimum Technique for WATM Error Control in Indoor Environment)

  • Kang, Young-Heung;Shin, Song-Sup
    • 한국정보통신학회논문지
    • /
    • 제4권5호
    • /
    • pp.1027-1035
    • /
    • 2000
  • 본 논문은 실내 환경에서의 WATM 에러 제어를 위한 최적 기술을 제안하였다. 최적 기술에서는, 기존의 concatenated FEC 기법만을 AWGN에서 실시간 서비스가 중요한 ATM 트래픽을 위한 효과적인 에러 제어 기술로 간주될 수 있지만 페이딩 환경에서는 concatenated FEC에 파일롯 심볼을 이용한 페이딩 보상이 WATM 성능을 최적화하는데 필요하다. 또한, truncated Type-II hybrid ARQ 기술은 처리량 개선을 위한 서비스 품질이 중요한 AW 트랙픽을 위해서 개발되어질 것이다. 따라서, 본 논문에서는 이를 각각의 기법에 대한 이론 및 시뮬레이션 평가를 수행하여 실내 환경에서의 WATM 성능의 최적화를 모색하였다.

  • PDF

빌딩간 연결을 통한 복합제어시스템의 최적설계 (Optimal Design of Hybrid Control System through Inter-Building Connection)

  • 박관순;옥승용
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.81-88
    • /
    • 2017
  • This study deals with the optimal design of a hybrid control system composed of a combination of active control system and passive control system for effective seismic performance improvement of two adjacent structures. The proposed hybrid control system adopts a configuration of installing an active control device in one building and connecting two adjacent structures with a passive control device so that the one-side active control force can be bi-directionally applied to both buildings through the passive connecting devices. In order to derive the optimal performance of the proposed system, the design parameters of the passive and active control systems were searched using the genetic algorithm. Numerical simulations of 10-story and 8-story buildings have been performed to verify the effectiveness of the proposed technique. For the purpose of comparison, the conventional independent control system with two identical active control systems being installed separately for each structure was also optimally designed and its seismic response has been evaluated as well. From the comparative results of the two control systems, it is demonstrated that the proposed hybrid control system requires larger control force for its one-side active control device than the conventional independent control system does for each of both-side active devices, but quite less than the total control force required for both-side devices of the independent control system, while maintaining similar seismic performance. Therefore, the proposed system is more economical and reliable than the conventional independent control system with two identical active devices.

초고층건물의 풍응답제어를 위한 스마트 TMD의 퍼지 하이브리드제어 (Fuzzy Hybrid Control of a Smart TMD for Reduction of Wind Responses in a Tall Building)

  • 김한상;김현수
    • 한국전산구조공학회논문집
    • /
    • 제22권2호
    • /
    • pp.135-144
    • /
    • 2009
  • 본 연구에서는 초고층건물의 풍응답을 저감시키기 위하여 스마트 TMD(STMD)를 활용한 퍼지 하이브리드 제어기법을 제안하였다. 효과적인 제어알고리즘을 개발하기 위하여 STMD의 응답저감에 우수한 성능을 보이는 스카이훅(skyhook) 제어기와 구조물의 응답저감에 뛰어난 그라운드훅(groundhook) 제어알고리즘을 사용하였다. 본 연구에서는 두 제어기를 적절히 조합하기 위하여 최적의 가중치를 실시간으로 결정하는 퍼지 하이브리드 제어기를 개발함으로써 일반적인 가중합방식의 하이브리드 제어기법의 성능을 개선하였다 제안된 제어기의 성능을 검토하기 위하여 풍하중을 받는 76층 사무소 건물을 예제구조물로 사용하였다. MR감쇠기를 이용하여 STMD를 구성하였고, STMD의 제어성능을 평가하기 위하여 TMD및 ATMD의 성능과 비교하였다. 수치해석을 통하여 STMD의 제어성능이 TMD에 비하여 월등히 뛰어남을 확인할 수 있었다. 또한 퍼지 하이브리드 제어기법을 사용하면 스카이훅 및 그라운드훅 제어기를 효과적으로 조합하여 STMD와 건물의 응답을 동시에 줄일 수 있음을 확인하였다.

Robust optimization of a hybrid control system for wind-exposed tall buildings with uncertain mass distribution

  • Venanzi, Ilaria;Materazzi, Annibale Luigi
    • Smart Structures and Systems
    • /
    • 제12권6호
    • /
    • pp.641-659
    • /
    • 2013
  • In this paper is studied the influence of the uncertain mass distribution over the floors on the choice of the optimal parameters of a hybrid control system for tall buildings subjected to wind load. In particular, an optimization procedure is developed for the robust design of a hybrid control system that is based on an enhanced Monte Carlo simulation technique and the genetic algorithm. The large computational effort inherent in the use of a MC-based procedure is reduced by the employment of the Latin Hypercube Sampling. With reference to a tall building modeled as a multi degrees of freedom system, several numerical analyses are carried out varying the parameters influencing the floors' masses, like the coefficient of variation of the distribution and the correlation between the floors' masses. The procedure allows to obtain optimal designs of the control system that are robust with respect to the uncertainties on the distribution of the dead and live loads.

마이크로프로세서를 이용한 하이브리드 PWM 인버터의 설계 (A design of hybrid PWM inverter using microprocessor)

  • 노창주;임재문;박중순
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.37-50
    • /
    • 1987
  • In an effort to conserve electric power, variable voltage variable frequency pulse width modulated (PWM) inverters are being applied increasingly to the variable speed control of the induction motors. The use of the PWM technique in motor drive applications is considered advantageous in many ways. For industrial applications, the PWM drive obtains its DC input through simple uncontrolled rectification of the commercial AC line and is favored for its good power factor, good efficiency, its relative freedom regulation problem, and mainly for its ability to operate the motor with nearly sinusoidal current waveforms. The purpose of this paper is to design a three phase natural sampled PWM inverter using microprocessor with simple control algorithm and hybrid control circuit has been built to implement this PWM scheme. In this system, the microprocessor can be used only for calculations directly related to motor control tasks by the design of hybrid circuit which sends PWM signals to the motor.

  • PDF

압전 작동기/감지기를 이용한 평판의 혼합형 능동 진동제어 기술 (Hybrid Technique for Active Vibration Control of Plate using Piezoceramic Actuators/Sensors)

  • 김영식;이철;김인수
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.1048-1058
    • /
    • 2000
  • 본 논문에서는 압전 세라믹 재료를 작동기 및 감지기로 이용한 사각 경계면이 고정된 얇은 사각평판의 능동 진동제어 방법을 제시한다. 실험 데이터에 기초한 다중 입출력계의 주파수영역 모델링방법을 이용하여 분포된 센서 및 구동기 특성이 포함된 구조물의 동적 특성이 규명된다. 제어기 구조로는 혼합형을 채택하고 되먹임 제어기는 LQG 제어기법에 의해 설계된다. 앞먹임 제어기는 다중 filtered-$x$ 최소자승오차법에 의해 적응되도록 한다. 진동제어에 대한 시뮬레이션 및 실험결과는 제안된 제어기법이 지속적 외란 및 과도적 외란에 효율적으로 적용될 수 있음을 보인다.

  • PDF

유연성 구조를 가지는 2 자유도 매니퓰레이터의 힘과 위치 제어 (Hybrid Position/Force Control of 2 DOF Flexible Manipulator)

  • 박선용;이영석;서보혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.389-391
    • /
    • 1996
  • A Hybrid technique is introduced in this paper for a manipulator with 2 DOF flexible links. The manipulator dynamics plus the actuator dynamics is controlled by taking force feedback for the end-effector of the link 2 while controlling the position of link I to control the position of the end-effector.

  • PDF

A Fault Tolerant Control Technique for Hybrid Modular Multi-Level Converters with Fault Detection Capability

  • Abdelsalam, Mahmoud;Marei, Mostafa Ibrahim;Diab, Hatem Yassin;Tennakoon, Sarath B.
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.558-572
    • /
    • 2018
  • In addition to its modular nature, a Hybrid Modular Multilevel Converter (HMMC) assembled from half-bridge and full-bridge sub-modules, is able to block DC faults with a minimum number of switching devices, which makes it attractive for high power applications. This paper introduces a control strategy based on the Root-Least Square (RLS) algorithm to estimate the capacitor voltages instead of using direct measurements. This action eliminates the need for voltage transducers in the HMMC sub-modules and the associated communication link with the central controller. In addition to capacitor voltage balancing and suppression of circulating currents, a fault tolerant control unit (FTCU) is integrated into the proposed strategy to modify the parameters of the HMMC controller. On advantage of the proposed FTCU is that it does not need extra components. Furthermore, a fault detection unit is adapted by utilizing a hybrid estimation scheme to detect sub-module faults. The behavior of the suggested technique is assessed using PSCAD offline simulations. In addition, it is validated using a real-time digital simulator connected to a real time controller under various normal and fault conditions. The proposed strategy shows robust performance in terms of accuracy and time response since it succeeds in stabilizing the HMMC under faults.