• 제목/요약/키워드: hybrid anti-islanding method

검색결과 3건 처리시간 0.016초

향상된 고조파 검출 능력을 갖는 계통연계 인버터의 하이브리드 단독운전 방지기법 (A Hybrid Anti-islanding Detection Scheme for Utility Interactive Inverter with Enhanced Harmonic Extraction Capability)

  • 강성욱;김경화
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.312-319
    • /
    • 2014
  • When distributed generation such as a wind power system is connected to the grid, it should meet grid requirements like IEEE Std. 1547, which regulates the anti-islanding method. Since the islanding may cause damage on electrical equipments or safety hazards for utility line worker, a distributed generation should detect it as soon as possible. This paper proposes a hybrid anti-islanding method coupled with the active and passive detection methods. To enhance the harmonic extraction capability for an active harmonic injection method, cascaded second-order band-pass filter and signal processing scheme are employed. Simulation and experiments are carried out under the islanding test condition specified in IEEE Std. 1547. Passive over/under voltage and over/under frequency methods are combined with the active method to improve the detection speed under certain condition. The simulation and experimental results are presented to verify that the proposed hybrid anti-islanding method can effectively detect the islanding.

PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법 (A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System)

  • 강성욱;김경화
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

중요부하를 갖는 하이브리드 ESS의 무효전력 변동에 의한 단독운전방지 기법 (Anti-islanding Method by Reactive Power Variation of Hybrid ESS with Critical Load)

  • 박성열;권민호;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.79-80
    • /
    • 2015
  • 중요부하를 갖는 하이브리드 ESS에서는 계통이상시에도 중요부하에 끊김없고 안정적인 전원을 공급해야한다. 기존 직접 전류 제어 방식은 독립운전시 전압제어를, 계통연계시 전류제어를 하기 때문에 모드전환시 과도상태가 발생하고, 단독운전 검출전에도 부하의 전압과 주파수가 변동하여 중요부하에 심각한 영향을 줄 수 있다. 본 논문에서는 모드 전환시 과도상태를 최소화하면서 단독운전 검출전에도 부하 전압과 주파수를 일정하게 유지하는 간접전류제어 기반의 인버터에서 무효전력변동 기법을 이용한 새로운 단독운전방지 기법을 제안한다.

  • PDF