• Title/Summary/Keyword: hwang-to concrete

Search Result 621, Processing Time 0.028 seconds

An Experimental Sutdy on the Fluidity and Strength Properties of Concrete According to the Replacement ratio of Non Firing Hwang-toh (비소성 황토의 치환율에 따른 콘크리트의 유동특성 및 강도특성에 관한 실험적 연구)

  • Lee, Jong-Sung;Lee, Seung-Min;Lee, Ji-Hwan;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.375-376
    • /
    • 2009
  • This study aims to provide basic material of concrete in replacement of non firing Hwang-toh, a traditional construction material in order to reduce CO$_2$ produced during manufacturing due to effectuation of the current Kyoto Protocol.

  • PDF

Study on Physical Properties of Permeable Concrete Block According to Vibration Time (진동다짐시간에 따른 투수콘크리트 블록의 물리적 특성에 관한 연구)

  • Kim, Hwang-Hee;Kim, Choon-Soo;Kang, Su-Man;Sun, Joung-Soo;Park, Chan-Gi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.303-304
    • /
    • 2010
  • In the study, the vibration time affects the properties of permeable concrete block to interpret and improving the performance of permeable concrete block to provide preliminary data for the said purpose.

  • PDF

A new base plate system using deformed reinforcing bars for concrete filled tubular column

  • Park, Yong-Myung;Hwang, Won-Sup;Yoon, Tae-Yang;Hwang, Min-Oh
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.375-394
    • /
    • 2005
  • An experimental study was conducted to develop a new base plate anchorage system for concrete filled tubular column under an axial load and a moment. The column was connected to a concrete foundation using ordinary deformed reinforcing bars that are installed at the inside and outside of the column. In order to investigate the moment resisting capacity of the system, horizontal cyclic loads are applied until the ultimate condition is reached with the axial load held constant. To derive a design method for moment resisting capacity, the reinforced concrete section approach was investigated with the assumption of strain compatibility. The results by this approach agreeded well with those of experiments when the bearing pressure of confined concrete and tangent modulus of steel bars are assumed appropriately. Also, it was found that the column interaction curve can be used to predict the yield strength of the base plate system.

Performance Evaluation of Natural Jute Fiber Reinforced Recycled Coarse Aggregate Concrete Using Response Surface Method (반응표면 분석법을 이용한 천연마섬유보강 순환굵은골재 콘크리트의 성능 평가)

  • Jeon, Ji Hong;Kim, Hwang Hee;Kim, Chun Soo;Yoo, Sung Yeol;Park, Chan Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • In this study, evaluated ware the strength and durability of the vegetated water purification channel concrete to which recycled aggregates, hawang-toh and jute were applied. Box-Behnken method of response surface analysis in statistics was applied to the experimental design. Experimental variables are as follows, recycled coarse aggregates, hawang-toh, blast-furnace slag and jute fiber. In the experiment, conducted were the tests of compressive strength, chloride ion penetration, abrasion resistance and impact resistance the replacement rate effects of the recycled aggregates, blast-furnace slag and hwang-toh on the performance of vegetated water purification channel concrete were analyzed by using the response surface analysis method on the basis of the experimental results. In addition, an optimum mixing ratio of vegetated water purification channel concrete was determined by using the experimental results. The optimum mixing ratio was determined to be in 10.0% recycled coarse aggregates, 60.0% blast-furnace slag, 10.1% hwang-toh and 0.16% jute fiber. The compressive strength, chloride ion penetration, abrasion rate, and impact number of fracture test results of the optimum mixing ratio were 24.1 MPa, 999 coulombs, 10.30 g/mm3, and 20 number, respectively.

The Stress-Strain Relationship and Compressive Strength of Concrete Containing Hwangtoh and Slag (황토와 슬래그를 첨가한 콘크리트의 강도 및 응력-변형률 관계)

  • Kang, Hong-Ki;Yang, Keun-Hyeok;Lee, Young-Ho;Hwang, Hey-Zoo;Chung, Heon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.672-675
    • /
    • 2004
  • The objective of this study was to understand the effect of hwangtoh and slag on various properties of concrete. Main variables were replacement level of admixtures, hwangtoh and slag, and curing temperature. Test results indicated that the compressive strength of concrete replaced by either hwangtoh and slag was significantly influenced by curing temperature. The elasticity modulus and compressive peak strain of concrete showed a small increase with increasing hwangtoh replacement.

  • PDF

Effect of Shear Reinforcement and Compressive Stress on the Shear Friction Strength of Concrete (콘크리트의 전단마찰 내력에 대한 횡보강근 및 압축응력의 영향)

  • Hwnag, Yong-Ha;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.419-426
    • /
    • 2016
  • This study examined the effect of transverse reinforcement and compressive stress on the shear friction performance at the shear interface intersecting two structural elements with various concrete types. From the prepared 12 push-off test specimens, various characteristics at the interface were measured as follows: crack propagation, shear load-relative slip relationship, initial shear cracking strength, ultimate shear friction strength, and shear transfer capacity of transverse reinforcement. The configuration of transverse reinforcement and compressive strength of concrete insignificantly influenced the amount of relative slippage at the shear friction plane. With the increase of applied compressive stress, the shear friction capacity of concrete tended to increase proportionally, whereas the shear transfer capacity of transverse reinforcement decreased, which was insignificantly affected by the configuration type of transverse reinforcement. The empirical equations of AASHTO-LRFD and Mattock underestimate the shear friction strength of concrete, whereas Hwang and Yang model provides better reliability, indicating that the mean and standard deviation of the ratios between measured shear strengths and predictions are 1.02 and 0.23, respectively.

Shear Strength of Reinforced Concrete Beams Strengthened by Fiber Reinforced Polymer (섬유보강 철근콘크리트 보의 전단강도 평가)

  • Hwang Hyun-Bok;Lee Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.401-404
    • /
    • 2004
  • In recent years, the use of fiber reinforced polymer (FRP) composites to repair or strengthen existing reinforced concrete (RC) structures is increasing In order to evaluate the shear strengths of RC structures strengthened by FRP composites, it is needed to understand the shear failure modes of these structures. This paper presents a rational equation to distinguish the shear fail modes of RC structures strengthened by FRP composites using the compatibility aided truss models.

  • PDF

An Experimental Evaluation of Chloride Content and Chloride Penetration Depth in Concrete by Deicing Agent Type (제설제 종류에 따른 콘크리트 염화물 침투깊이 및 염화물량의 실험적 평가)

  • Lee, Sang-Hyun;Jo, Hong-bum;Kim, Young-Sun;Kim, Kwang-Ki;Ryu, Hwang-Sung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.276-277
    • /
    • 2017
  • Deicing agent affect concrete durability such as scaling, rebar corrosion strength of concrete. In this study, developed deicing agent satisfied with EL610 is evaluated to compare affects to concrete with no deicing agent and chloride-containing deicing agents. Deicing agents are applied to concrete surface during four months twice a week. Chloride content, chloride penetration depth and concrete strength are evaluated. After experiment, chloride content, chloride penetration depth of concrete are as follows. Chloride-containing deicing > Eco friendly deicer > No deicing agents. Concrete strength are also as follows. Chloride-containing deicing > Eco friendly deicer > No deicing agents. From experiment, developed deicing agent shows low chloride content in concrete and affect concrete strength little lower than chloride-containing deicing.

  • PDF

Mock-up Test on the Reduction of Hydration Heat of Mass Concrete for Transfer Girder (전이보 매스콘크리트의 수화열 저감에 관한 Mock-up 실험)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.707-710
    • /
    • 2004
  • This paper reported the results of mock-up test on mass concrete for transfer girder using setting time difference of super retarding agent(SRA). According to test results, two mock-up structures were made. Plain concrete without placing layer reached maximum temperature after 24hours since placement and caused surface hydration cracks at top section. However, concrete with placing layer reached maximum temperature after 72hours and surface temperature was higher than center temperature, which did not cause surface crack. After form removing, no crack was observed at side surface of plain concrete, while concrete using SRA at mid section had surface scaling and settling crack. According to coring results, concrete with placing layer had a penetration crack from top section to bottom section. Therefore, the setting time difference method to reduce hydration heat will have difficulty in applying the mass concrete for transfer girder.

  • PDF

An Experimental Study on Concrete Stress Distribution in Compression Zone (콘크리트 압축 응력분포에 관한 실험적 연구)

  • Lee, Jae-Hoon;Lim, Kang-Sup;Choi, Jin-Ho;Choi, Young-Ho;Hwang, Do-Kyu;Yoo, Hyun-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.79-80
    • /
    • 2009
  • Compression stress distribution used to concrete structure design substitutes equivalent rectangle, trapezoid and parabola-rectangle stress block for actual concrete stress distribution. Presently, rectangular stress block of Korea Concrete Design Code is equal to it of ACI code that doesn't reflect the material feature of the high strength concrete. The study does an experiment on concrete compression stress distribution to know the material feature of the concrete used in korea.

  • PDF