• 제목/요약/키워드: humidities

검색결과 149건 처리시간 0.018초

$SnO_2$계 일산화탄소 가스 감지 소자의 주위온도, 습도 의존성에 관한 연구 (Dependency of SnO2 System Carbon Monoxide Gas Sensor on the Atmospheric Temperature & Humidity)

  • 정형진;김종만;이전국
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1004-1010
    • /
    • 1990
  • SnO2-ThO2-PdCl2-In2O3 gas sensing ceramic systems were studied in order to lowr the operating temperatures and reduce the dependence of ambient temperatures and humidities. Sensing materials were coated by brush on the alumina tube followed by the impregnation of solidfier(ethylsilicate). Coated species were dried and sintered at 75$0^{\circ}C$ for 30min. carbon monoxide gas detecting sensitiviteis were measured in various ambinet temperatures and humidities. In the composition of 94SnO2-5ThO2-PdCl2 system carbon monoxide gas detecting sensors showed the highest detecting sensitivities and the lowest operating temperature(15$0^{\circ}C$). As the ambient temperatures and humidities were increased, sensitivities were decreased. Because the oscillation effects were observed at high humidities, it was suggested that the sensitivities of sensors depend greatly on the humidities.

  • PDF

녹차(綠茶)의 흡습특성(吸濕特性) (Sorption characteristics of Green Tea)

  • 이주백;정신교;손태화;최종욱
    • Current Research on Agriculture and Life Sciences
    • /
    • 제4권
    • /
    • pp.50-54
    • /
    • 1986
  • 시판(市販) 녹차(綠茶)를 $20^{\circ}C$에서 상대습도(相對濕度)를 달리하여 저장하면서 흡습특성(吸濕特性)을 조사하였다. 녹차(綠茶)의 흡습속도(吸濕速度)는 저장상대습도(貯藏相對濕度)가 높을수록 컸으며 저장시간(貯藏時間)이 경과함에 따라 점차 감소하였다. 녹차(綠茶)의 등온흡습곡록(等溫吸濕曲綠)은 전형적인 Sigmoid 형태를 나타내었으며 상대습도(相對濕度)가 일정할 때 저장시간과 흡습속도와의 관계에서 다음과 같은 식(式)을 구할 수 있었다. $ln{\frac{dw}{dt}}=nln(t)+lnc$ B.E.T. 식(式)에 의해 구한 녹차(綠茶)의 단분자층수분함량(單分子層水分含量)은 7.01~7.87%로 나타났다. 저장시간(貯藏時間)과 흡습속도관계식(吸濕速度關係式)에서 구한 계산치 수분함량과 실측치수분함량을 비교한 결과 거의 유사한 경향이었다.

  • PDF

동결건조 어육지질의 변화에 미치는 상대습도의 영향 (Effect of Relative Humidity on the Changes of Lipids in Freeze-Dried Fish during Storage)

  • 이형일;박영호
    • 한국수산과학회지
    • /
    • 제18권6호
    • /
    • pp.519-528
    • /
    • 1985
  • 어류의 저장 중 지질의 변화에 미치는 상대습도의 영향을 밝히기 위하여 적색육어류인 고등어와 백색육어류인 가자미를 동결건조하여 마쇄, 혼합한 것을 일정량씩 각각 $0\%,\;23\%,\;52\%$$81\%$의 상대습도로 조절된 용기에 넣어 $25^{\circ}C$에 저장하여 두고 경시적으로 지질의 산가, 과산화물가, TBA값 및 지방산조성 등의 변화를 측정하여 저장 습도에 따른 지질산화도를 비교 검토하였다. 1. 저장 중 지질의 과산화물가 및 TBA값의 변화를 볼 때 저습도에 저장하는 경우가 고습도에 저장하는 경우 보다 산화가 촉진되는 경향을 나타내었다. 산가는 고습도에 저장한 경우가 저습도에 저장한 경우보다 크게 증가하는 변화를 보였다. 2. 전지질의 지방산조성은 고등어, 가자미 모두 $C_{16:0}$산, $C_{18:1}$산 및 $C_{22:6}$산의 함량이 높았으며, 비극성지질과 극성지질의 지방산조성은 고등어, 가자미 모두 비극성지질에서는 $C_{18:1}$산의 함량이, 극성지질에서는 $C_{16:0}$산의 함량이, 가장 많았으며, 극성지질은 비극성지질에 비해 $C_{22:6}$산의 함량이 특히 많았다. 3. 고등어 지질은 산가, 과산화물가 및 TBA값등의 변화로 보아 가자미 지질보다 안정성이 떨어지고, 지방산조성의 변화에 있어서는 양자가 거의 비슷한 경향을 나타내었다. 4. 저장 중 지방산조성의 변화는 전지질의 경우에는 상대습도 $0\%$$23\%$에서는 polyene산이 감소하는 경향을 나타내었으며, 상대습도 $52\%$$81\%$에서는 큰 변화가 없었다. 비극성지질의 경우에는 상대습도 $0\%$$23\%$에서 polyene산이 감소하였고, 상대습도 $52\%$$81\%$에서는 포화산과 monoene산이 증가하였다. 반면에 극성지질의 경우에는 상대습도 $0\%$$23\%$에서는 polyene산이, $52\%$$81\%$에서는 포화산과 monoene산이 감소하는 경향을 나타내었다.

  • PDF

습도에 따른 DLC 코팅의 마찰 거동 (Tribological Behavior of DLC Coatings at Various Humidities)

  • 조경만;안효석;김대은
    • 대한기계학회논문집A
    • /
    • 제26권9호
    • /
    • pp.1842-1848
    • /
    • 2002
  • Although DLC coatings have good tribological properties, these are dependant on the deposition method, the property of contact surface, and test condition. Humidity, which has little influence on tribological behavior in macro scale, is an important factor of tribological behavior in small devices like MEMS. The objective of this study is to investigate the tribological behavior of DLC coatings with particular attention to their wettability at various humidities. DLC coatings were deposited on Si substrates and tested using a reciprocating friction tester against Si$_3$N$_4$balls at various humidities. The results showed that the tribological behavior of DLC coatings was dependant on relative humidity and wettablility of DLC coatings. Friction coefficient at high relative humidity was higher thar that at low relative humidity. The tungsten-containing DLC coatings had a good wear resistance at low relative humidity whereas DLC coatings derived from argon(Ar)+cesium(Cs) gases showed a good wear resistance at high relative humidity.

적송재(赤松材)의 흡습(吸濕)과 팽창성(膨脹性)에 관(關)하여 (The hygroscopic and swelling properties of Korean Red Pine wood)

  • 이필우
    • 한국산림과학회지
    • /
    • 제4권1호
    • /
    • pp.30-32
    • /
    • 1965
  • Many kind tree species are growing in Korea. However most of them are inferior in wood qualities and production for commercial utilization except several species. Among the useful several species Red Pine (Pinus densiflora S. et. Z.) is growing in main tree species and most generally utilizing wood in korean forest. It is used widely as mine timbers, cross ties, boxes, floorings, pulpwoods, constructions and engineerings. Although this species is most useful and economical in this country, the basical properties on relation between wood and relative humidities were not studied certainly. This study was performed by need of inspection the hygroscopic and swelling properties to be apllied for physical manufacturing. According to the results the Equilibrium Moisture Contents of each relative humidity conditions are as table (3), and the swelling values of sap and heartwood are as table (4) and (5) in text. In this study sapwood moisture contents are higher than heartwood in each relative humidities conditions. Tangential and radial ratios of average swelling values are 1:1.971 in sapwood and 1:2.178 in heartwood.

  • PDF

혈당측정을 위한 폴리아크릴로니트릴 진단막의 제조(3) : 보관 환경이 글루코우즈의 농도 측정에 미치는 영향 (The Preparation of Polyacrylonitrile Diagnostic Membranes for Blood Glucose Measurements (3) : Effects of Storage Environments on the Measurements of Glucose Concentration)

  • 권석기;유재우
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.222-227
    • /
    • 2009
  • 당뇨병 환자의 자가 혈당 측정 장치에 사용할 수 있는 폴리아크릴로니트릴 진단막을 제조하였다. 제조된 폴리아크릴로니트릴 진단막을 여러 가지 환경에서 보관한 후 혈액 속의 글루코우즈의 농도를 변화시켜가며 680 nm에서의 최종 흡광도를 측정하였다. 측정된 혈당치가 보관 온도의 변화에 따라서는 크게 차이를 보이지 않았다. 다만 여러 가지 습도에서 보관한 후 측정한 결과 높은 습도에서 장기간 보관한 후의 혈당치가 기준 값보다 다소 감소하는 것을 알 수 있었다.

배기열 회수용 종이 열교환기의 성능예측에 관한 연구 (A Study on the Performance Prediction of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 유성연;김진혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.294-299
    • /
    • 2005
  • In order to control indoor air quality and save energy. it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. Paper heat exchanger can recover $50{\sim}70$ of the enthalpy difference between supply and exhaust air. The purpose of this research is to obtain the experimental correlations for the friction factor, heat transfer coefficient, mass transfer coefficient and permeance of paper heat exchanger, which can be used for the performance prediction of the paper heat exchanger. Pressure drop at various velocities and heat transfer rate at various dry-bulb temperatures, relative humidities, and specific humidities are measured to make experimental correlations. The results of prediction using correlations show fairly good agreement with experimental data.

  • PDF

훈연상대습도가 Canadian Bacon 품질특성에 미치는 영향 (Effects of Smokehouse Humidities on Quality Characteristics of Canadian Bacon)

  • 박태규;이근택
    • 한국식품과학회지
    • /
    • 제21권5호
    • /
    • pp.662-668
    • /
    • 1989
  • 훈연처리 중 4가지 습도(98%, 75%, 50%, 35%)가 Canadian bacon 품질에 미치는 영향을 알아보기 위해서 염지육색, pH, 진유 아질산량, 페놀 축적, TBA치 그리고 수율을 측정하였다. 높은 습도에서 생산된 제품은 높은 발색율과 낮은 pH 치를 나타내었으며, 낮은 습도일수록 잔유 아질산량이 높았다. 또한 높은 습도에서는 페놀 축적량과 TBA 치가 높았으며 가장 낮은 습도에서는 수율이 가장 높았다.

  • PDF

페녹시-메틸아미노 포스파젠 당뇨병 진단막의 글루코우즈 농도 측정에 미치는 온도와 습도의 영향 (Effects of Temperature and Humidity on the Glucose Measurements with Phenoxy-Methylamino Phosphazene Diagnostic Membranes)

  • 권석기
    • 멤브레인
    • /
    • 제26권3호
    • /
    • pp.179-186
    • /
    • 2016
  • 당뇨병 환자의 혈당을 측정하기 위해 새로운 형태의 페녹시-메틸아미노 포스파젠 진단막을 제조하였다. 먼저 측정 환경이 혈당 측정에 미치는 영향을 조사하였다. 활성화된 진단막을 가지고 5, 15, 25, 35, $45^{\circ}C$ 그리고 상대습도 20%에서 80%까지 변화시키면서 시간에 따른 680 nm에서의 흡광도 변화량(K/S)를 측정하였다. 높은 측정온도와 습도에서도 K/S와 글루코우즈 농도와의 기울기 값(Dose-Response Slope : DRS)은 크게 영향을 받지 않았다. 두 번째로, 제조된 진단막을 여러 환경에서 보관한 후, 보관 환경이 글루코우즈의 농도 측정에 미치는 영향을 조사하였다. 새로운 포스파젠 진단막을 $50^{\circ}C$에서 8주 보관한 후 측정한 결과, 보관시간과 온도가 크게 영향을 주지 않았다. 또 상대습도 80%에서도 새로운 포스파젠 진단막의 안정성이 확인되었다.