• 제목/요약/키워드: humidifier

검색결과 202건 처리시간 0.03초

무기질 도료의 조습성능에 관한 연구 (A study on humidity control characteristics of inorganic paint)

  • 허정용;최창호;이윤규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1225-1230
    • /
    • 2008
  • Recently the building material have been developed with the concept of controlling the indoor environment as well as the concept of emitting contaminants less. So, a lot of products with humidity control characteristics put it on the market. However, objective evaluation to these products doesn't work out. Thus consumers cannot obtain accurate information to these products. Therefore, we selected inorganic paint in the functionality materials and evaluated its humidity control characteristic in this research. We divided by four stages and evaluated this inorganic paint. The 1st and 2nd third experiments were executed on a natural condition and the fourth experiment was executed with humidity had been raised by using the humidifier.

  • PDF

중앙공조 및 개별공조에서의 외조기 적용 (Application of Four-season Dedicated Outdoor Air Handling Unit in Central and Personal Air-conditioning)

  • 박승태;김영일;이태호;최세영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.591-596
    • /
    • 2008
  • The present study has been conducted to study the performance of dedicated outdoor air handling unit in central and personal air-conditioning. With conventional central and personal air-conditioning systems which are designed according to the maximum load, humidity increase above comfort level can not be avoided as the cooling load decreases. The adoption of dedicated outdoor air handling unit, however, can solve this problem. Moreover, the dedicated outdoor air handling unit has the characteristics of anti-bacteria due to dry coil, energy saving and good indoor air quality. During cooling seasons, dedicated outdoor air handling unit can save energy up to 30% than the conventional cooling+reheating system for controlling both temperature and humidity.

  • PDF

병원 감염관리에 대한 실태조사 -간호수기를 중심으로 - (A survey on Hospital Infection)

  • 이선옥
    • 대한간호학회지
    • /
    • 제23권3호
    • /
    • pp.325-338
    • /
    • 1993
  • This study was conducted to evaluate the methods used in nursing procedures for infection control. Skilled nursing procedures are related to prevention of hospital infection. The sample consisted of 301 nurses’ response to the questionnaire. Data were collected from Feb. to March, 1993 from 35 hospitals located in five major cities. The findings of the study are as follows : 1) Rotatively unsafe nursing procedures were reported for preperation of IV therapy, change of IV site and aseptic dressing on IV site, hand wash-ing and use of paper towels, use of sterile urine bottle with indwelling urinary catheter, management of dressing cart, disinfection of transfer forcep, ambu respirator, laryngoscope, humidifier and handling of incubator. 2) Relatively safe nursing procedures were reported for management of suction tube, marking for contaminated materials and waste collection. The rate of participation in education programs for infection control by the nurses was higher than in other research results. 3) Further study on procedures for IV site in-fusion and care of dressing cart are recommended.

  • PDF

룰 베이스를 이용한 공조기의 고장검출 및 진단 (Fault Detection and Diagnosis of an Air Handling Unit Based on Rule Bases)

  • 한도영;주명재
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.552-559
    • /
    • 2002
  • The fault detection and diagnosis (FDD) technology may be applied in order to decrease the energy consumption and the maintenance cost of the air conditioning system. In this study, rule bases and curve fitting models were used to detect faults in an air handling unit. Gradually progressed faults, such as the fan speed degradation, the coil water leakage, the humidifier nozzle clogging, the sensor degradation and the damper stoppage, were applied to the developed FBD system. Simulation results show good detections and diagnoses of these faults. Therefore, this method may be effectively used for the fault detection and diagnosis of the air handling unit.

내부 가습형 연료전지 스택의 출력전압 왜곡 보상 기법 (Compensation for Output Voltage Distortion in Fuel Cell Stack with Internal Humidifier)

  • 구근완;우동균;주동명;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.170-171
    • /
    • 2012
  • 본 논문은 일부 내부 가습형 연료전지 스택에서 가습시 발생되는 출력전압의 단락현상을 해결하기 위한 다양한 방법들을 제시한다. 가습구간동안 배터리로부터의 전력을 활용하는 제어알고리즘 적용 방법, 출력전압의 허용 범위를 만족시키기 위해 하드웨어적으로 보상하는 방법들을 제안하고 실험을 통해 그 효과를 검증한다.

  • PDF

라즈베리파이와 온습도센서를 이용한 자연식가습기 (A Natural Humidifier using Raspberry Pie's Temperature and Humidity Sensort)

  • 박재현;남길우;이현일;박지현;이은서
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2019년도 추계학술발표대회
    • /
    • pp.218-220
    • /
    • 2019
  • 현대인들의 실내건강관리를 위해서 라즈베리파이에 DHT11센서를 이용하여 자동으로 실내 습도를 유지시키고 안드로이드 앱을 이용하여 수동으로 동작가능 하도록 구현하였다.

Determination of Water Soluble Trace Gass in Ambient Air by Condenser-type Diffusion Denuder Coupled Ion Chromatography

  • 장인형;최낙현;이보경;이동수
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권3호
    • /
    • pp.329-332
    • /
    • 1999
  • An automated method is developed for simultaneous determination of water soluble gases at parts per trillion level in the environmental air. The method involves temperature-humidity control of sample air using a thermostated humidifier, collection of analyte gases by condenser-type effluent diffusion denuder and subsequent effluent analysis by ion chromatography. The detection limits (3(σ) of the method for CH3COOH, HNO2 and SO2 gases are 0.022, 0.019 and 0.009 ppbv, respectively. The precisions range from 0.3 to 3.0% RSD. The method has been successfully applied to urban air analysis and some results for nitrous acid and SOx, in Seoul air are presented.

A study on Removal Method of Humidifier Particles Using Electrostatic Precipitation Technology

  • Inpyo Cha;Taekeon Jung;Hyunjun Yun;Chuljun Choi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권3호
    • /
    • pp.239-245
    • /
    • 2023
  • In this research, our objective was to investigate the efficacy of electrostatic precipitation in capturing mist particles. We assumed that it could be helpful in multi-functional facilities and similar environments where both humidification and dehumidification are required. We derived the air density of the humidified air based on its properties using Dalton's law. The analysis was performed to evaluate the collection efficiency of capturing mist aerosols of various sizes. As a result, we revealed that under the conditions of a dry-bulb temperature of 26.0℃ and relative humidity of 8%, the system achieved a collection efficiency of 99.999% or more for aerosols larger than 2.5㎛. These results indicate that electrostatic precipitation technology shows great promise as an effective method for capturing mist particles.

일반 가구의 가습기살균제 노출 특성 및 건강이상 경험과의 연관성 (Characteristics of Exposure to Humidifier Disinfectants and Their Association with the Presence of a Person Who Experienced Adverse Health Effects in General Households in Korea)

  • 이은선;정해관;백도명;김솔휘;임종한;김판기;이경무
    • 한국환경보건학회지
    • /
    • 제46권3호
    • /
    • pp.285-296
    • /
    • 2020
  • Objective: The objective of this study was to describe the characteristics of exposure to humidifier disinfectants (HDs) and their association with the presence of a person who experienced the adverse health effects in general households in Korea. Methods: During the month of December 2016, a nationwide online survey was conducted on adults over 20 years of age who had experience of using HDs. It provided information on exposure characteristics and the experience of health effects. The final survey respondents consisted of 1,555 people who provided information on themselves and their household members during the use of HD. Exposure characteristics at the household level included average days of HD use per week, average hours of HD use per day, the duration within which one bottle of HD was emptied, average input frequency of HD, amount of HD (cc) per one time used, and active ingredients of HD products (PHMG, CMIT/MIT, PGH, or others). The risk of the presence of a person who experienced adverse health effects in the household was evaluated by estimating odds ratios (ORs) and 95% confidence intervals (CIs) adjusted for monthly income and region using a multiple logistic regression model. Subgroup analyses were conducted for households with a child (≤7 years) and households with a newborn infant during HD use. Results: The level of exposure to HD tended to be higher for households with a child or newborn infant for several variables including average days of HD use per week (P<0.0001) and average hours of HD use per day (P<0.0001). The proportion of households in which there was at least one person who experienced adverse health effects such as rhinitis, asthma, pneumonia, atopy/skin disease, etc. was 20.6% for all households, 25.3% for households with children, and 29.9% for households with newborn infants. The presence of a person who experienced adverse health effects in the household was significantly associated with average hours of HD use per day (Ptrend<0.001), duration within which one bottle of HD was emptied (Ptrend<0.001), average input frequency of HD (Ptrend<0.001), amount of HD per one use (Ptrend=0.01), and use of HDs containing PHMG (OR=2.23, 95% CI=1.45-3.43). Similar results were observed in subgroup analyses. Conclusion: Our results suggest that level of exposure to HD tended to be higher for households with a child or newborn infant and that exposure to HD is significantly associated with the presence of a person who experienced adverse health effects in the household.

CFD 분석에 의한 느타리버섯 재배사 환경균일성 향상 연구 (The study on enhanced micro climate of the oyster mushroom cultivation house with multi-layered shelves by using CFD analysis)

  • 이성현;유병기;이찬중;임영택
    • 한국버섯학회지
    • /
    • 제15권1호
    • /
    • pp.14-20
    • /
    • 2017
  • 버섯의 단위면적당 생산량을 증대시키기 위하여 다단으로 재배되는 버섯재배사는 재배균상이 내부공기의 유동을 막는 장애물로 작용하여 균상의 아래쪽과 위쪽간의 환경차이가 발생한다. 이러한 환경차이 때문에 버섯재배 균상의 위치에 따른 생육차이가 발생한다. 본 연구에서와 같이 버섯재배사 내부에서 버섯이 생육되지 않는 작업통로의 상단에 천장방향으로 대류팬을 설치하여 운용하면 재배사 내부의 공기를 전체적으로 균일하게 유지할 수 있는 것으로 나타났다. 다만, 버섯재배사 내부에 설치된 각종 환경조절장치 즉 유니트쿨러, 입기팬, 배기팬, 대류팬, 가습기 등이 모두 한꺼번에 가동될 때는 버섯재배 균상위의 RMS 값이 속도 23.86%, 온도 6.08%, 습도 2.72%로 나타났다. 하지만 유니트쿨러와 대류팬이 가동될 때는 균상위의 RMS 값이 속도 23.54%, 온도 0.51%, 습도 0.41%로 나타났다. 따라서 버섯재배사의 환경조절을 위한 입기팬, 배기팬과 가습기는 용량이 큰 것을 설치하여 전체적인 가동시간을 줄이고, 유니트쿨러와 대류팬을 조합한 환경관리 방법이 내부 환경의 균일성 향상에 큰 도움이 될 것으로 판단된다.