• Title/Summary/Keyword: humidifier

Search Result 202, Processing Time 0.021 seconds

A Study on The Control of Humidification and Dew Condensation by On/Off Control (On/Off 제어에 의한 습도와 결로의 제어에 관한 연구)

  • Park, Dea-Heum;Kim, Du-Hee;Kim, Kyoung-Hoon;Jung, Young-Guan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.835-841
    • /
    • 2011
  • The humidification is essential for performance enhancement of the electrolysis of PEMFC because proton conductivity depends on hydration of the proton exchange membrane. In this study, the humidification experiment did about On/Off control the humidification and dew condensation for PEMFC by using of the membrane humidifiers. As the results, it was possible to approximation control of the humidity by using of the solenoid valve On/Off control on the membrane humidifier. Also the problem on the dew condensation was resolved by approximation humidity control through solenoid valve On/Off control and the removal of the dew condensation in the flow channel was verified through visualization experiment.

Study on Compound Humidifier Employing UV-LED using Environmental Life Cycle Assessment (환경전과정평가에 기반한 UV-LED 를 사용한 복합식 가습기에 관한 연구)

  • Choi, Won-Sik;Park, Si-Hyun;Lee, Si-Wang;Jung, Young-Mi;Yi, Hwa-Cho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.9
    • /
    • pp.931-937
    • /
    • 2012
  • In this study, we assessed environmental impacts of compound humidifiers using environmental life cycle assessment and presented the ways to improvements in energy consumption of them. We found eco-design parameters and $CO_2$-eq emissions in each stage of raw material acquisition, manufacturing, transportation, use and disuse in life cycle of the compound humidifiers. The highest $CO_2$ emission is found to be in the stage of use among all stages of life cycle, which is mainly due to power consumption in thermal heating of heating coil for sterilization during humidification. The power consumption and $CO_2$ emission in the stage of use can be reduced to 1/4 and 1/3 at the highest estimate through improvement of sterilization method, respectively. We suggested the replacement of conventional thermal heating coil by ultra violet light-emitting diodes (UV-LED) for sterilization and then presented the experimental results on the sterilization effects of UV-LEDs.

Corporate Responsibility for Consumer Chemical Products in Korea (생활화학제품 관련 기업의 책임 이행 현황과 과제)

  • Lee, Juncheol;Kim, Shinbum
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.4
    • /
    • pp.321-325
    • /
    • 2019
  • The recent humidifier disinfectant disaster has caused a great change in our society and lead the Korean people to lose faith in the government and corporations. To overcome this mistrust, the government and corporations have undertaken certain efforts, including a voluntary agreement on consumer product safety. All the ingredients of a consumer product should be disclosed according to this voluntary agreement. There were also unexpected benefits occuring from this process. We found that the concept of corporate responsibility for product safety differed greatly among the various actors in Korean society. Corporations believed that a product could be considered safe if it contained no regulated substances. We have come to believe that this may be an important cause of the humidifier disinfectant disaster. The Korean government, corporations, and civil organizations have reached a consensus that it is a corporation's responsibility to evaluate the risks of products before they are introduced to the market. However, the limitations of these voluntary efforts are clear, and the legal system needs to be improved. We suggest that the concept of extreme recklessness should be introduced into regulations on product safety.

Erratum to "Population Size Estimates for the Use of Humidifier Disinfectants and Experience of Health Effects from Exposure to Humidifier Disinfectants" (정오 "가습기 살균제 노출 및 건강피해 규모 평가 연구")

  • Lee, Kyoung-Mu;Paek, Domyung;Cheong, Hae-Kwan;Kim, Solwhee;Seo, Jung-Wook;Hong, Young-seob;Kim, Hyeongsu;Lee, Jongwha;Leem, Jonghan;Kim, Pangyi
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.559-560
    • /
    • 2019

Investigation of Exposure Status to Humidifier Disinfectant in Hospitals: An On-site Investigation of 23 Hospitals (가습기살균제 사용 의료기관 노출 현황 연구: 23개 노출 현장 실지 조사를 중심으로)

  • Han, Kyunghee;Jo, Eun-Kyung;Seo, Young-Joon;Kwak, Jung Hyun;Yang, Wonho;Kim, Pan-Gyi;Choi, Yoon-Hyeong
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.4
    • /
    • pp.433-443
    • /
    • 2020
  • Objective: This study aimed to introduce the use of humidifier disinfectant (HD) in hospitals based on an on-site investigation. Methods: A preliminary survey and on-site investigation of HD use were conducted in 23 hospitals. Among them, one hospital without previous information on HD use was selected for a pilot investigation; 22 hospitals were selected based on previous documents and exposure statements from parliamentary investigation and exposure assessment regarding HD. Descriptive statistics were used to present distribution and characteristics of HD purchase and HD use in hospitals. Also, details on interviews from the on-site investigation were described. Results: Among the 23 hospitals, a total of ten were confirmed to have purchased and used an HD (nine hospitals) or HD-like product (one hospital). For the purchased HD products, four hospitals reported 'Aekyung Gaseupgi Mate', two hospitals reported 'Oxy Ssakssak New Gaseupgi Dangbun', and one hospital reported 'Homeplus Gaseupgi Chungjungje' (one hospital used three kinds of HD products). One hospital reported an HD-like product and four hospitals were 'Unknown'. For the number of HD products purchased, five hospitals reported '100 or less', two hospitals reported 'More than 100', and three hospitals were 'Unknown'. For each of the ten hospitals, we described detailed characteristics of HD purchase and its exposure status obtained through on-site investigation, including the purchase volume (i.e., number of products), exposure space (i.e., patient's room, staff space), and exposure period. Additionally, a comparison of on-site investigation and parliamentary investigation or exposure assessment regarding HD was reported. Conclusion: This study introduced detailed cases of HD purchase and HD use in hospitals based on an on-site investigation, and our findings revealed a possibility of a considerable volume of HD exposure in various multiuse facilities, including hospitals.

Classification and Characterization of Exposure Rating in Humidifier Disinfectants through Calculation of PHMG Reference Concentration (PHMG (polyhexamethylene guanidine) 흡입독성참고치 산출을 통한 가습기살균제 노출등급 분류 및 특성)

  • Kim, Eunchae;Ryu, Hyeonsu;Park, Jinhyeon;Choe, Youngtae;Heo, Jung;Lee, Seula;Jo, Eun-Kyung;Choi, Yoon-Hyeong;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.3
    • /
    • pp.335-343
    • /
    • 2020
  • Objectives: The Korean Ministry of Environment has identified cases of people suspected of suffering lung disease potentially caused by polyhexamethylene guanidine (PHMG) used in humidifier disinfectants (HDs). Exposure assessment for the HDs was conducted using a questionnaire during face-to-face interview. The main purposes of this study were to develop a methodology to effectively classify levels of exposure to HDs based on a questionnaire. Methods: We first identified the overall participants' exposure characteristics by HD exposure levels; Second, we selected misclassified subjects and investigated characteristics of overestimated and underestimated subjects, focusing on exposure cases to PHMG-containing HDs. An inhalation reference concentration (RfC) for PHMG was produced on the basis of inhalation toxicity values. We made a cross-tabulation of the exposure classes (Exposure classes 1-to-4) by clinical classes based on the RfC. When the value of the exposure class minus the clinical class was 0 or 1, we assumed these were true values. When the value was ≥2 and ≤ -2, we assigned these cases to the overestimation group and underestimation group, respectively. Results: The overestimated group may have already recovered and responded excessively due to psychological anxiety or in order to receive compensation. On the other hand, relatively high mortality rates and surrogate responses for those under 10 years of age may have resulted in inaccurate exposure assessment for underestimated groups. For the characteristics of exposure, it was shown that for the underestimated group, the exposure was relatively weaker than the overestimated group, even though a high overall clinical rating was determined. Conclusions: This study may suggest ways to reduce bias and overcome the limitations of current HD exposure assessment.

Humidifier disinfectant lung injury, how do we approach the issues?

  • Choi, Jihyun Emma;Hong, Sang-Bum;Do, Kyung-Hyun;Kim, Hwa Jung;Chung, Seockhoon;Lee, Eun;Choi, Jihyun;Hong, Soo-Jong
    • Environmental Analysis Health and Toxicology
    • /
    • v.31
    • /
    • pp.19.1-19.7
    • /
    • 2016
  • A large portion of the Korean population has been exposed to toxic humidifier disinfectants (HDs), and considering that the majority of the victims are infants, the magnitude of the damage is expected to be considerably larger than what has currently been revealed. The current victims are voicing problems caused by various diseases, including but not limited to lung, upper respiratory tract, cardiovascular, kidney, musculoskeletal, eye, and skin diseases, etc. However, there has been difficulty in gaining validation for these health problems and identifying causal relationships due to lack of evidence proving that toxic HD is the specific causes of extrapulmonary diseases such as allergic rhinitis. Furthermore, the victims and bereaved families of the HD case have not received any support for psychological distress such as post-traumatic stress disorder, depression, feelings of injustice, and anger caused by the trauma. In addition, because the underlying mechanisms of the toxic materials within the HDs such as polyhexamethylene guanidine phosphate, poly(oxyalkylene guanidine) hydrochloride, chloromethylisothiazolinone /methylisothiazolinone have yet to be determined, the demand for information regarding the HD issue is growing. The victims of the HD cases require support that goes beyond financial aid for medical costs and living expenses. There is a desperate need for government-led integrated support centers that provide individualized support through health screenings; in other words, we need an integrated facility that provides the appropriate social support to allow the victims to recover their physical and mental health, so as to well prepare them to return to a normal life. The implementation of such a plan requires not only the close cooperation between those departments already directly involved such as the Ministry of Environment and the Ministry of Health and Welfare, but also active support on a national scale from pan-governmental consultative bodies.

The Role of Exposure Assessment of Humidifier Disinfectant (HD) in the Program to Monitor HD Associated Health Problems (가습기 살균제 건강영향 모니터링에서 환경노출조사의 역할)

  • Park, Soyoung;Park, Ju-Hyun;Lee, Seunghee;Jang, Woo-Sung;Kim, So-Yeon;Park, Jihoon;Mun, Eunchan;Lee, Yesung;Kim, Hyunil;Kim, Hyeong-Cheol;Park, Dong-Uk
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.224-231
    • /
    • 2020
  • Objective: The objectives of this study are to update the information on the characteristics of humidifier disinfectant (HD) usage with HD associated health problems and to discuss the role of HD exposure assessment in the national program to monitor health problems in patients with HD associated diseases. Method: A total of 201 HD associated patients who registered to undergo clinical examination at Kangbuk Samsung Hospital was interviewed to acquire their responses regarding several HD use characteristics, including type of HD brands used, HD use duration, average daily HD use hours, and the volume of the room in which HD was used. The responses of the HD associated patients to HD use-related questions were compared between responses in the lung injury investigation and this study. Results: The responses of HD associated patients in this study were found to be different from those in the lunginjury investigation. In particular, some of the patients who had not answered in the lung-injury investigation were able to answer thanks to assistance from the investigator in this study. For their responses regarding the name of the most commonly used HD brand, the number of patients who did not answer (N=11) was reduced to eight in this study. Significant changes in the responses of study subjects to questions related to HD use were achieved through the interview in this study. Conclusion: This study found significant changes in the responses regarding HD use characteristics. HD exposure assessment should be included in the program in order to allow surveillance of HD associated health problems.

Affecting Factors of Lung Disease and Classification of Exposure Rating of Applicants for Injuries from Humidifier Disinfectants (가습기살균제 피해신청자들의 노출등급 분류 및 폐질환 발생 영향요인 분석)

  • Gihong, Min;Junghyun, Shin;Eun-Kyung, Jo;Dayoung, Jeong;Jiyoon, Ryu;Dongjun, Kim;Jaemin, Woo;Sungho, Bae;Jihun, Shin;Seula, Lee;Yoon-Hyeong, Choi;Wonho, Yang
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.6
    • /
    • pp.324-330
    • /
    • 2022
  • Background: Lung injuries due to exposure to humidifier disinfectants (HDs) were reported in 2011 in South Korea. As a result of the government's epidemiological investigation and toxicity test study, it was found that HDs caused health damage such as lung disease. Objectives: The purpose of this study was to classify HD exposure ratings and analyze the affecting factors that could identify the relationship with lung disease. Methods: Exposure assessment for HDs was conducted using a questionnaire during face-to-face interviews with the applicants. Ratings of high exposure (Class 1) and low exposure (Class 2) were cross-tabulated with clinical ratings (acceptable and unacceptable). Logistic regression analysis was carried out by setting the clinical rating of lung disease as a dependent variable and the socio-demographic and exposure characteristics obtained through the questionnaire as independent variables. Results: The concentration in air of polyhexamethylene guanidine (PHMG) was 71.96±107.47 ㎍/m3, and the exposure concentration was 15.21±23.28 ㎍/m3 . The exposure rating was overestimated with 97.1% of affected subjects having high exposure using margin of exposure (MOE), but only 9.9% matching the clinical class. In the overestimated group, it could be explained by the fact that the exposure time was long and the subjects had already recovered from damage symptoms. As a result of logistic regression analysis, ten variables were found to be significant influencing factors. Conclusions: A new exposure rating could be calculated based on the MOE, and factors affecting lung disease could be estimated through comparative evaluation with the clinical rating.

Analysis of Exposure Characteristics and Exposure Rating of Participants with Injuries from CMIT/MIT Humidifier Disinfectants (CMIT/MIT 가습기살균제 사용에 따른 피해구제 신청자의 노출등급 및 노출특성 분석)

  • Gihong Min;Junghyun Shin;Eun-Kyung Jo;Seula Lee;Jihun Shin;Dongjun Kim;Jaemin Woo;Yoon-Hyeong Choi;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.3
    • /
    • pp.169-177
    • /
    • 2023
  • Background: The Korea Centers for Disease Control and Prevention (KCDC) has identified cases of people suspected of suffering lung disease potentially caused by chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) used in humidifier disinfectants (HDs). The Korean Ministry of Environment (MoE) epidemiological investigation and toxicity test study found that HDs caused health damage such as asthma and lung disease. Objectives: The main purposes of this study were to classify the HD exposure rating and to analyze the exposure characteristics that affect exposure to CMIT/MIT HDs. Methods: The exposure characteristics and socio-demographic characteristics of victim participants using CMIT/MIT HDs were investigated through questionnaires. An inhalation no observed adverse effect level (NOAEL) for CMIT/MIT was produced based on inhalation toxicity values. Exposure ratings (class 1~class 2) were cross-tabulated with clinical ratings (acceptable~unacceptable). A correlation analysis was conducted with the main exposure characteristics that affect the exposure concentration of CMIT/MIT HDs. Results: The concentration in indoor air of CMIT/MIT was 8.75±25.40 ㎍/m3, and the exposure concentration was 2.30±6.29 ㎍/m3. The CMIT/MIT exposure rating of 67 participants with high exposures of not more than MOE 100 were evaluated as 14.5%, while the damage participants who matched the clinical rating made up 4.5%. The exposure concentration of CMIT/MIT showed a positive correlation with the daily usage amount and usage frequency, and a negative correlation with volume of the indoor environment. Conclusions: A new exposure rating could be suggested and calculated based on the MOE, and the factors affecting the exposure concentration could be identified.