• Title/Summary/Keyword: human-body simulation

Search Result 339, Processing Time 0.03 seconds

The Analysis of Wearers' Impression to Combination of their Body Type with Neutral Tone Wear - focused on Pants- (체형과 무채색 톤조합에 따른 의복 착용자의 인상 평가 -팬츠차림을 중심으로-)

  • Paeng, Suk-Kyung;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.15 no.4
    • /
    • pp.631-646
    • /
    • 2006
  • The purpose of this study is to find out its effect on wearers' impression formated by combination of their body type with neutral tone clothing. The experimental materials developed for this study are a set of responses to stimulus in scales(7-point semantic). 45 pictures used as stimulus are, through computer simulation, manipulated to five wearers' body type and nine neutral tone wear. The subjects are 276(?) female undergraduate students in Kyung-nam area. Factors on wearers' impression suggested as responses to the stimulus consist of 5 different demensions (Tenderness, Cuteness, Attractiveness, Elegance, Intrepidity). The results of this study are as follows: first, combination of their body type with neutral tone wear significantly affects the formation of wearers' impression in the factor of Tenderness, Attractiveness, and Intrepidity (?); to the factor of Attractiveness, wearers' body type is rather more related than wearers' neutral tone wear is. Second, the harmony of their body type with neutral tone wear has a significant effect on wearers' impression in the factor of Cuteness. According to those results, the combination of wearers' body type with neutral tone wear has significant effects on the formation of wearers' impression.

  • PDF

Calculation of the Electromagnetic Fields Distribution around the Human Body and Study of Transmission Loss Related with the Human Body Communication (인체 통신에 따른 인체 주변에서의 전기장 분포 계산 및 전송 손실 연구)

  • Ju, Young-Jun;Gimm, Youn-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.251-257
    • /
    • 2012
  • Human body communication means transmitting and receiving data through human body medium or through free space along with the human body skin. Electric field distribution around the human body between the transmitter and the receiver were calculated at five different frequencies with 5 MHz interval between 10 MHz and 30 MHz. Commercial electromagnetic simulation tool was used for the calculation of E-field distributions applying the Korean standard male model including 29 different kinds of human tissues. After calculating specific absorption rate(SAR) values on back of the hand, it was compared with International Commission on Non-Ionizing Radiation Protection(ICNIRP) human protection guideline. While conductivities(${\sigma}$) and relative permittivities(${\varepsilon}_r$) of the human tissues for each frequency were input as the analyzing parameters, electric field intensities near both hands were integrated along the integral line between the nearby electrodes for the calculation of the transmitting and receiving voltages whose ratio was defined as channel loss. The calculated channel losses were about ($75{\pm}1$) dB and showed nearly flat response all through the evaluated frequencies.

Design of a Miniaturized High-Isolation Diversity Antenna for Wearable WBAN Applications

  • Kim, Seongjin;Kwon, Kyeol;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.1
    • /
    • pp.28-33
    • /
    • 2013
  • This paper proposes a miniaturized high-isolation diversity antenna for wearable wireless body area network (WBAN) applications. An inverted-F type radiating element is used to reduce the overall dimension of the proposed antenna to $30mm{\times}30mm{\times}2.5mm$. The antenna performance on the human body phantom is analyzed through simulation and the performance of the fabricated antenna is verified by comparing the measured data with that of the simulation when the antenna is placed on a semi-solid flat phantom with equivalent electrical properties of a human body. The fabricated antenna has a 10 dB return loss bandwidth over the Industrial Scientific Medical (ISM) band from 2.35 GHz to 2.71 GHz and isolation is higher than 28 dB at 2.45 GHz. The measured peak gain of antenna elements # 1 and # 2 is -0.43 dBi and -0.54 dBi, respectively. Performance parameters are analyzed, including envelope correlation coefficient (ECC), mean effective gain (MEG), and the MEG ratio. In addition, the specific absorption ratio (SAR) distributions of the proposed antenna are measured for consideration in use.

The Impression Evaluation of the Cloth's Wearer in Relation to Tone Combination and Body Type of Wearer (의복의 톤조합과 착용자의 체형에 따른 인상평가 (제1보))

  • Paeng, Suk-Kyung;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.13 no.6
    • /
    • pp.1007-1021
    • /
    • 2004
  • The purpose of this study is to find out the effect of wearers' body types and clothes' neutral tone combination on impression formation. The experimental materials developed for this study are a set of stimulus and response scales(7-point semantic). The stimulus include 45 pictures manipulated by computer simulation in wears' body types and neutral tone variation. The subjects are 540 female undergraduate students in Gyeong-nam. The results of this study are as follows: Impression factor of the stimulus consisted of 5 different dimensions including tenderness, cuteness, attractiveness, elegance, intrepidity. Each impression of neutral tone combinations, along with wears' body types, had a significant effect on tenderness, attractiveness, and intrepidity. Especially, it had the strongest effects on attractiveness. Each impression of wearers' body types along with neutral tone combinations affected cuteness significantly. According to the fact above, wears' body types and neutral tone combination have a significant influence on the impression formation of wearers.

  • PDF

Virtual Science Lab - Sensible Human Body Learning System (가상 과학 실험실 - 체감형 인체 구조 학습 시스템)

  • Kim, Ki-Min;Kim, Jae-Il;Kim, Seok-Yeol;Park, Jin-Ah
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.2078-2079
    • /
    • 2009
  • This research suggests the framework for human body learning system using various forms of bidirectional interfaces. The existing systems mostly use the limited and unidirectional methods which are merely focused on the visual information. Our system provides more realistic visual information using 3D organ models from the real human body. Also we combine the haptic and augmented reality techniques into our system for wider range of interaction means. Through this research, we aim to overcome the limitation of existing science education systems and explore the effective scheme to fuse the real and virtual educational environment into one.

  • PDF

Human Body Vibration Analysis under Consideration of Seat Dynamic Characteristics (시트 동특성을 고려한 인체 진동 해석)

  • Kang, Juseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5689-5695
    • /
    • 2012
  • In this study, vibration properties of seat and human body are analyzed through test and numerical analysis methods by taking into account the viscoelastic characteristics of polyurethane foam as seat material which is applied for vehicle. These viscoelastic characteristics which show nonlinear and quasi-static behavior are obtained by compression test. In addition, the viscous elastic property of polyurethane foam is modelled mathematically by using convolution integral and nonlinear stiffness model. In order to analyze the performance on ride comfort of seat, vertical vibration model is established by using dynamic model of seat and vertical vibration model of human body at ISO5982, and so the related motion equations are derived. A numerical analysis simulation is applied by using the nonlinear motion equation with Runge-Kutta integral method. The dynamic responses of seat and human body on the input of vibration acceleration measured at the floor of the railway vehicle are examined. The variation of the index value at ride comfort on seat design parameters is analyzed and the methodology on seat design is suggested.

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • v.8 no.2
    • /
    • pp.52-59
    • /
    • 2012
  • This study uses digital imaging and communications in medicine (DICOM) files acquired after CT scan to obtain the absorbed dose distribution inside the body by using the patient's actual anatomical data; uses geometry and tracking (Geant)4 as a way to obtain the accurate absorbed dose distribution inside the body. This method is easier to establish the radioprotection plan through estimating the absorbed dose distribution inside the body compared to the evaluation of absorbed dose using thermo-luminescence dosimeter (TLD) with inferior reliability and accuracy because many variables act on result values with respect to the evaluation of the patient's absorbed dose distribution in diagnostic imaging and the evaluation of absorbed dose using phantom; can contribute to improving reliability accuracy and reproducibility; it makes significance in that it can implement the actual patient's absorbed dose distribution, not just mere estimation using mathematical phantom or humanoid phantom. When comparing the absorbed dose in polymethly methacrylate (PMMA) phantom measured in metal oxide semiconductor field effect transistor (MOSFET) dosimeter for verification of Geant4 and the result of Geant4 simulation, there was $0.46{\pm}4.69%$ ($15{\times}15cm^2$), and $-0.75{\pm}5.19%$ ($20{\times}20cm^2$) difference according to the depth. This study, through the simulation by means of Geant4, suggests a new way to calculate the actual dose of radiation exposure of patients through DICOM interface.

The Comparison of Field Uniformity and SAR between TEM, Loop and Combined Elemented 16 Channel Transmit Arrays (TEM 형과 Loop 형의 전송소자를 이용한 16채널 3T Body 전송코일의 자장 균일도와 안전도 비교)

  • Ryu, Yeunchul;Kim, Young Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.404-408
    • /
    • 2014
  • In this research we evaluate the excitation homogeneity and SAR of three different Tx arrays after B1+ Shimming in the human body at 3T. Through the simulations, we compared the field properties that are standard deviation and mean value of transverse magnetization for 1) strip line TEM array, 2) rectangular loop array, 3) combined array of strip line element and rectangular loop and shown the utilities of B1+ shimming in human body model. After B1+ shimming, it is evaluated four different types of SAR for body mesh through whole body simulation; those are average, maximum 1-cell, maximum 1-gram, and maximum 10-gram SAR. It appears that in this particular comparison an array based on strip line elements can produce better homogeneity and lower SAR than an array of rectangular loops or an array of combined elements (strip line and loop). While many factors are considered in designing coils for production, it is hoped that methods and results like these will be used in the future to guide decisions and maximize benefit.

Comparison of Impulses Experienced on Human Joints Walking on the Ground to Those Experienced Walking on a Treadmill

  • So, Byung-Rok;Yi, Byung-Ju;Han, Seog-Young
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.2
    • /
    • pp.243-252
    • /
    • 2008
  • It has been reported that long-term exercise on a treadmill (running machine) may cause injury to the joints in a human's lower extremities. Previous works related to analysis of human walking motion are, however, mostly based on clinical statistics and experimental methodology. This paper proposes an analytical methodology. Specifically, this work deals with a comparison of normal walking on the ground and walking on a treadmill in regard to the external and internal impulses exerted on the joints of a human's lower extremities. First, a modeling procedure of impulses, impulse geometry, and impulse measure for the human lower extremity model will be briefly introduced and a new impulse measure for analysis of internal impulse is developed. Based on these analytical tools, we analyze the external and internal impulses through a planar 7-linked human lower extremity model. It is shown through simulation that the human walking on a treadmill exhibits greater internal impulses on the knee and ankle joints of the supporting leg when compared to that on the ground. In order to corroborate the effectiveness of the proposed methodology, a force platform was developed to measure the external impulses exerted on the ground for the cases of the normal walking and walking on the treadmill. It is shown that the experimental results correspond well to the simulation results.

The study on the influences of vibration associated with cycling on the human body (자전거 주행 중 발생하는진동이 인체에 미치는 영향)

  • Chung, Kyung-Ryul;Hyeong, Joon-Ho;Kim, Sa-Yup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.643-646
    • /
    • 2009
  • This study was conducted to simulate the influence of vibration associated with cycling on the body. In this simulation the human model that the riding on a bicycle which have suspension and non-suspension front forks was used. And to arouse impact two kind of bump, 50mm height of radical raised spot and 150mm height of slow raised spot, were used. The vertical displacement of head, the vertical acceleration of head and the torque of neck joint were analysed. The results say that the function of shock absorbing was grater when passing though a 50mm height of radical raised spot then a 150mm height of slow raised spot.

  • PDF