• Title/Summary/Keyword: human-body simulation

Search Result 339, Processing Time 0.026 seconds

A Study on the Gait Test Human Dynamic Simulation Using Gait Motion Capture and Foot Pressure Measurement : Analysis of Gait Pattern with Wearing Military Equipment of Korean Male Adult (Gait Motion Capture 및 족압 측정을 이용한 보행특성시험 및 동력학적 인체 시뮬레이션 연구 : 한국인 성인 남자의 군장착용 보행 특성 해석)

  • Lee S.H.;Lee Y.S.;Choi Y.J.;Lee J.W.;Chae J.W.;Choi E.J.;Kim I.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.877-880
    • /
    • 2005
  • This paper suggests gait analysis and gait simulation method using Gait Motion Capture equipment and plantar pressure measurement system. The gait of normal person and how it will be effected by added weight with wearing military equipments are studied by suggested method. It is measured that a change of gait pattern when wears military equipments with Korean male adult(height 180 cm, weight 70 kg) and simulated its results.

  • PDF

Study on Daylight Inflow Environment Consequent on the Length of Light Shelf and Slat Angle Control for Fostering Visual Environment in Patient Rooms of Hospital - By Dynamic Daylight Simulation Using Weather Data - (종합병원 병실 내 시환경 조성을 위한 광선반 길이 및 Slat각 제어에 따른 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju Young;Lee, Ki Ho;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.113-121
    • /
    • 2012
  • A hospital is the most important infra-facility of the places which take care of people's body in social environment. There exist several environmental factors in the ways to heal the human body in hospital ward, but this study tried to look into the improvable pleasant sickroom environment with focus on light environment among the factors. In other words, this study aims at the research on proper daylight inflow into sickroom space as basic data for understanding the link between healing environment and natural lighting. In the simulation analysis through this research, this study completed the initial simulation using Autodesk Revit 2011 with focus on two types of individual multi-bed room units of the two general hospitals located in Gwangju City. This study made a simulation analysis of The two multi-bed rooms looking to the west using the weather data on Gwangju district, which is the strong point of ECOTECT2011. Conclusively, looking into the analysis of the simulation model in time of attaching the length of in & outside light shelf, the angle controlling of light shelf, the daylight factor and DA were found to show the tendency to decrease in the numerical value due to the decrease in sunlight inflow as the simulation model moved more toward the room from the window in comparison with the existing analysis of multi-bed rooms. Particularly, this study was able to read that the daylight factor and DA were more decreasing to improve at the light shelf than the existing bedrooms; conclusively, this study judges that the natural lighting simulation analysis could be helpful in improving the healing environment as basic data.

Adaptive Mass-Spring Method for the Synchronization of Dual Deformable Model (듀얼 가변형 모델 동기화를 위한 적응성 질량-스프링 기법)

  • Cho, Jae-Hwan;Park, Jin-Ah
    • Journal of the Korea Computer Graphics Society
    • /
    • v.15 no.3
    • /
    • pp.1-9
    • /
    • 2009
  • Traditional computer simulation uses only traditional input and output devices. With the recent emergence of haptic techniques, which can give users kinetic and tactile feedback, the field of computer simulation is diversifying. In particular, as the virtual-reality-based surgical simulation has been recognized as an effective training tool in medical education, the practical virtual simulation of surgery becomes a stimulating new research area. The surgical simulation framework should represent the realistic properties of human organ for the high immersion of a user interaction with a virtual object. The framework should make proper both haptic and visual feedback for high immersed virtual environment. However, one model may not be suitable to simulate both haptic and visual feedback because the perceptive channels of two feedbacks are different from each other and the system requirements are also different. Therefore, we separated two models to simulate haptic and visual feedback independently but at the same time. We propose an adaptive mass-spring method as a multi-modal simulation technique to synchronize those two separated models and present a framework for a dual model of simulation that can realistically simulate the behavior of the soft, pliable human body, along with haptic feedback from the user's interaction.

  • PDF

Comparative Studies on Absorbed Dose by Geant4-based Simulation Using DICOM File and Gafchromic EBT2 Film (DICOM 파일을 사용한 Geant4 시뮬레이션과 Gafchromic EBT2 필름에 의한 인체 내 흡수선량 비교 연구)

  • Mo, Eun-Hui;Lee, Sang-Ho;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • Monte Carlo method has been known as the most accurate method for calculating absorbed dose in the human body, and an anthropomorphic phantom has been mainly used as a method of simulating internal organs for using such a calculation method. However, various efforts are made to extract data on several internal organs in the human body directly from CT DICOM files in recent Monte Carlo calculation using Geant4 code and to use by converting them into the geometry necessary for simulation. Such a function makes it possible to calculate the internal absorbed dose accurately while duplicating the actual human anatomical structure. Thus, this study calculated the absorbed dose in the human body by using Geant4 associating with DICOM files, and aimed to confirm the usefulness by compare the result with the measured dose using a Gafchromic EBT2 film. This study compared the dose calculated using simulation and the measured dose in beam central axis using the EBT2 film. The results showed that the range of difference was an average of 3.75% except for a build-up region, in which the dose rapidly changed from skin surface to the depth of maximum dose. In addition, this study made it easy to confirm the target absorbed dose by internal organ and organ through the output of the calculated value of dose by CT slice and the dose value of each voxel in each slice. Thus, the method that outputs dose value by slice and voxel through the use of CT DICOM, which is actual image data of human body, instead of the anthropomorphic phantom enables accurate dose calculations of various regions. Therefore, it is considered that it will be useful for dose calculation of radiotherapy planning system in the future. Moreover, it is applicable for currently-used several energy ranges in current use, so it is considered that it will be effectively used in order to check the radiation absorbed dose in the human body.

Development of 3D Modeling Technology of Human Vacancy for Bio-CAD (Bio-CAD를 위한 인체공동부의 3차원 모델링 기술 개발)

  • Kim, Ho-Chan;Bae, Yong-Hwan;Kwon, Ki-Su;Seo, Tae-Won;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.138-145
    • /
    • 2009
  • Custom medical treatment is being widely adapted to lots of medical applications. A technology for 3D modeling is strongly required to fabricate medical implants for individual patient. Needs on true 3D CAD data of a patient is strongly required for tissue engineering and human body simulations. Medical imaging devices show human inner section and 3D volume rendering images of human organs. CT or MRI is one of the popular imaging devices for that use. However, those image data is not sufficient to use for medical fabrication or simulation. This paper mainly deals how to generate 3D geometry data from those medical images. A new image processing technology is introduced to reconstruct 3D geometry of a human body vacancy from the medical images. Then a surface geometry data is reconstructed by using Marching cube algorithm. Resulting CAD data is a custom 3D geometry data of human vacancy. This paper introduces a novel 3D reconstruction process and shows some typical examples with implemented software.

Analysis of SAR for body-mounted mobile phones (인체 착용형 무선 단말기에 대한 노출량 해석)

  • Park, Min-Young;Ko, Chea-Ok;Pack, Jeong-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.425-428
    • /
    • 2005
  • A variety of wireless devices are commercially available now. Most of studies, however, have been directed to the biological effects of mobile-phone EMF. In this study, dosimetric analysis for wireless devices of head-mounted display type and a wristwatch type were made to investigate possible biological effects of these devices. SAR (Specific Absorption Rate) distributions were calculated using FDTD (Finite Difference Time Domain) method, for adult human models such as standard Korean human model and VHP(Visible Human Project) model, as well as scaled models. Measurements were also performed for SAM phantom wearing a simplified prototype for a wireless device for validation of the simulation results. It has been found that children are more vulnerable to such exposure, and these devices could cause some biological effects for relatively lower power compared to conventional mobile pones.

  • PDF

Biomechanical Analysis of Human Balance Control

  • Shin, Youngkyun;Park, Gu-Bum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.63-71
    • /
    • 2014
  • A single-inverted-pendulum model is presented to simulate and predict the passive response of human balance control. This simplified biomechanical model was comprised of a torsional spring and damper, and a lump mass. An estimation of frequency response function was conducted to parameterize the complexity. The frequency domain identification method is used to identify the parameters of the model. The equivalent viscoelastic parameters of standing body were obtained and there was good conformity between the simulation and experimental result.

유니사이클 로봇의 주행경로를 변경하기 위한 퍼지룰의 구성

  • 김중완;안찬우;전언찬;한근조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.761-765
    • /
    • 1997
  • Our study of rider's postulator stability and tracking control on a unicycle began form the observation of a human riding. The system including unicycle and human operationg his unicycle is a fuzzy intelligent biomechanical model on basis of instinct and intuition search mechanisms. We proposed a robotic unicycle with one wheel and one body as a basic mode and derived equation of motion to this model. Our works is in making out fuzzy look-up table to control robotic unicycle. Fuzzy look-up table were determined for staight line and curve under reasonable inference emulating human's instinct and intuition riding a unicyale. Simulation results show that postulator stability and tracking control on both straight line and curve were successful by using proposed each fuzzy look-up table.

  • PDF

Analysis of Optimal Dynamic Absorbing System considering Human Behavior induced by Transmitted Force

  • Kim, Hyo-Jun;Choe, Eui-Jung
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.6
    • /
    • pp.38-43
    • /
    • 2003
  • In this study, the optimal dynamic absorbing system for the gas operated HIF (high implusive force) device has been investigated. For this purpose, firstly, the dynamic behavior of human body induced by impulsive disturbances has been analyzed through a series of experimental works using the devised test setup. The characteristics of linear impulse has been compared under some conditions of support system. In order to design the optimal dynamic absorbing system, the parameter optimization process has been performed based on the simplified isolation system model under constraints of moving displacement and transmitted force. Finally, the performance of the designed dynamic absorbing system has been evaluated by simulation in the actual operating condition.

Development of Cholecystectomy Simulation for Laparoscopic Surgery Training (복강경수술 훈련용 담낭 절제술 시뮬레이션 개발)

  • Kim, Young-Jun;Roy, Frederick;Lee, Seung-Bin;Seo, Joon-Ho;Lee, Deuk-Hee;Park, Se-Hyung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.5
    • /
    • pp.303-311
    • /
    • 2012
  • Laparoscopic surgery is a surgical procedure which uses long laparoscopic instruments through tiny holes in abdomen while watching images from a laparoscopic camera through umbilicus. Laparoscopic surgeries have many advantages rather than open surgeries, however it is hard to learn the surgical skills for laparoscopic surgery. Recently, some virtual simulation systems for laparoscopic surgery are developed to train novice surgeons or resident surgeons. In this study, we introduce the techniques that we developed for laparoscopic surgical training simulator for cholecystectomy (gallbladder removal), which is one of the most frequently performed by laparoscopic surgery. The techniques for cholecystectomy simulation include modeling of human organs (liver, gallbladder, bile ducts, etc.), real-time deformable body calculation, realistic 3D visualization of surgical scene, high-fidelity haptic rendering and haptic device technology, and so on. We propose each simulation technique for the laparoscopic cholecystectomy procedures such as identifying cystic duct and cystic artery to clamp and cut, dissecting connective tissues between the gallbladder and liver. In this paper, we describe the techniques and discuss about the results of the proposed cholecystectomy simulation for laparoscopic surgical training.