• Title/Summary/Keyword: human pressure

Search Result 1,117, Processing Time 0.028 seconds

Human Sensibility Measurement for the Visual Picture Stimulus (장면 시자극에 대한 감성측정에 관한 연구)

  • 김동윤;김동선;권의철;임영훈;손진훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.85-89
    • /
    • 1997
  • We present several biosignal measurement results and analysis algorithms for the visual stimulus from International Affective Picture Sytem. Sine human body is nonlinear dynamic system, we investigated both linear and nonlinear methods. We found that the alpha wave of EEG, the chaos of peripheral blood pressure, the LF/HF of HRV and thd retutn map of RR interval were good parameters for the measuremet of human sensibility. These can be used as the parameters for the measurement of human sensibility.

  • PDF

Implement of Blood Pressure Simulator Using Proportional Control Valve and Hybrid Controller (비례제어밸브와 혼합제어기를 이용한 혈압 시뮬레이터의 구현)

  • Lee K. W.;Kim C. H.;Han K. B.;Kim H. J.;Jeon G. R.
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2005.05a
    • /
    • pp.149-153
    • /
    • 2005
  • In the cardiovascular system, the waveform of the pulsatory blood pressure appears variously due to the cardiac impulse and compliance of blood vessels and arm tissue. We have constructed a blood pressure simulator to investigate effects of mechanical properties of artery walls and tissue on blood pressure measurements. The blood pressure simulator is designed to reproduce wave forms of blood pressure in human arteries. To minimize tracking error, we use a linear control valve, and adapt a hybrid control scheme which consists of a feedback controller and a feedforward controller. Any form of the pressure wave can be reproduced, changing function of the wave form in the computer connected to the simulator for control. From experiments, it has been shown that the simulator reproduces wave forms very well, and that the hybrid scheme adapted is superior to the feedback controller.

  • PDF

Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices (동력형 욕창예방제품의 교대부양 압력 프로파 특성)

  • Won, Byeong-Hee;Song, Chang-Seop
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.

A Study on the Gait Test Human Dynamic Simulation Using Gait Motion Capture and Foot Pressure Measurement : Analysis of Gait Pattern with Wearing Military Equipment of Korean Male Adult (Gait Motion Capture 및 족압 측정을 이용한 보행특성시험 및 동력학적 인체 시뮬레이션 연구 : 한국인 성인 남자의 군장착용 보행 특성 해석)

  • Lee S.H.;Lee Y.S.;Choi Y.J.;Lee J.W.;Chae J.W.;Choi E.J.;Kim I.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.877-880
    • /
    • 2005
  • This paper suggests gait analysis and gait simulation method using Gait Motion Capture equipment and plantar pressure measurement system. The gait of normal person and how it will be effected by added weight with wearing military equipments are studied by suggested method. It is measured that a change of gait pattern when wears military equipments with Korean male adult(height 180 cm, weight 70 kg) and simulated its results.

  • PDF

The Distribution of Genetic Polymorphism in the ACE2 Gene in Korean Essential Hypertensives (한국인 본태성 고혈압 환자군에서 ACE2유전자에 존재하는 A1075G다형성의 분포에 관한 연구)

  • Jang Min Hee;Kang Byung Yong;Lee Jae Koo;Lee Kang Oh
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.4 s.51
    • /
    • pp.303-309
    • /
    • 2005
  • Essential hypertension has been considered as multifactorial disease resulted from the interaction of both environmental and genetic factors. The renin-angiotensin system (RAS) plays an important role in the regulation of blood pressure homeostasis. Recently, a homologue of angiotensin I converting enzyme, ACE2 has been focused on as a candidate gene of essential hypertension in the experiments using animal model and human being. In this study, we carried out an association study in order to clarify the relationship between the A 1075G polymorphism in the ACE2 gene and essential hypertension in Korean subjects. Because this polymorphism is located on human chromosome X, the statistical analysis for each gender was performed separately. There were no significant differences in allele distribution of the A 1075G polymorphism in the ACE2 gene between normotensives and hypertensives in the both gender groups, respectively. However, this polymorphism was significantly associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) values in only female groups (P< 0.05). Thus, these results may suggest the probable role of ACE2 gene in the inter-individual susceptibility of female group to blood pressure variability.

A systemic approach for Roe Deer in Jesudo (제주도 한라산 노루에 관한 시스템적 접근)

  • Kim, Doa-Hoon;Hong, Young-Kyo
    • Korean System Dynamics Review
    • /
    • v.7 no.2
    • /
    • pp.191-213
    • /
    • 2006
  • Increasing of the number of Roe Deer in Jesudo is regarded as an direct cause of the damages of Roe Deer - i.e. damages of crops and trees by Roe Deer and traffic accidents between human and Roe Deer. But, no study of the number of Roe Deer in Jejudo has been found and never has been progressed it and nobody convinces about the total number of Roe Deer in Jejudo. In this paper, we focus at the moving pressure which enforces Roe Deer to move the other places. Moving pressure is appeared when the habitat environment destruction of Roe Deer and it forces Roe Deer in hilly section to move the middle mountains section and the low section. This moving pressure promotes the moving of Roe Deer to the other places and then the total number of Roe Deer in new places are increasing. High density of Roe Deer makes the habitat environment bad and increases the competition of Roe Deer. These patterns are repeated continuously. The habitat environment of Roe Deer is related with human life area very closely. We should keep and preserve our nature and environment, and if we develop our nature then we must consider our ecosystem in all aspects. It's the most important thing to us and Roe Deer and other living things.

  • PDF

Effects of Wear Training for Improving Vascular Compliance on Blood Pressures and Blood Lipid Profiles in Prehypertensive Subjects (온열요법으로서의 착의훈련이 고혈압 전단계자의 혈압 및 혈중 지질성분에 미치는 영향)

  • Yoo, Shin-Jung;Park, Joon-Hee
    • Korean Journal of Human Ecology
    • /
    • v.21 no.1
    • /
    • pp.141-149
    • /
    • 2012
  • This study investigates the effects of wear training on blood pressure and blood lipid profiles. For the purpose of this research, 'wear training' refers to the alternating stimulation of temperature while using specific clothing under controlled situations ($18.8{\pm}0.2^{\circ}C$, $38{\pm}3%RH$). The participants alternated between two different garments producing a $1.5^{\circ}C$ difference in the innerest microclimate temperature over a period of 4 weeks. The experiments in this study were conducted in a comfortable environment after sufficient rest. The results were as follows. The systolic blood pressure and mean arterial pressure were lower in the post test than in the pre test (p<.05). The atherogenic index (AI) was also reduced and the LDL-C/HDL-C ratio increased (p<.05) in the post test. These results demonstrated that wear training positively affected improvement in vascular stiffness.

Inactivation of various bacteriophages by different ultraviolet technologies: Development of a reliable virus indicator system for water reuse

  • Bae, Kyung Seon;Shin, Gwy-Am
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.350-354
    • /
    • 2016
  • There is an urgent need to identify more reliable indicator systems for human pathogenic viruses in water reuse practice. In this study, we determined the response of different bacteriophages representing various bacteriophage groups to different ultraviolet (UV) technologies in real wastewater in order to identify more reliable bacteriophage indicator systems for UV disinfection in wastewater. Bacteriophage ${\varphi}X174$ PRD1, and MS2 in two different real wastewaters were irradiated with several doses of both low pressure (LP) and medium pressure (MP) UV irradiation through bench-scale UV collimated apparatus. The inactivation rate of ${\varphi}X174$ by both LP and MP UV was rapid and reached ${\sim}4{\log}_{10}$ within a UV dose of $20mJ/cm^2$. However, the inactivation rates of bacteriophage PRD1 and MS2 were much slower than the one for ${\varphi}X174$ and only ${\sim}1{\log}_{10}$ inactivation was achieved by the same UV dose of $20mJ/cm^2$. Overall, the results of this study suggest that bacteriophage MS2 could be a reliable indicator for human pathogenic viruses for both LP and MP UV disinfection in wastewater treatment processes and water reuse practice.

Selection of the Measurement Points for the Garment Pressure of the Brassier and the Waist-Nipper (브래지어와 허리거들에 있어서 의복압 측정부위 선정에 관한 연구)

  • Baek, Yoon-Jeong;Choi, Jeong-Wha;Lee, Kyung-Suk
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.3
    • /
    • pp.445-453
    • /
    • 2007
  • This study was to select the measurement points for the brassier and the waist-nipper. 15 subjects (ages 30-40) were chosen by % body fat to represent various physical types. Subjects put on each garment, brassier and a waist-nipper, in turns. Measurement points in the underwear were selected according to the parts of human body. The characteristics and surface area of each garment was considered carefully when the measurement points were selected. Selected measurement points on a brassier and a waist-nipper were chosen from the anterior midsagittal line, the side-seam line, and the posterior midsagittal line. Three points on the brassier and three points on the waist-nipper were selected as the measurement points. There was a highly significant correlation between % body fat and mean garment pressure. There were no significant relationships between thickness of subcutaneous fat and mean garment pressure by measured parts.

  • PDF