• Title/Summary/Keyword: human pressure

Search Result 1,125, Processing Time 0.034 seconds

Effects of Aqua-Acupuncture of Jibaikjihwangtang on the Blood Pressure in Hypertensive Rats (지백지황탕(知柏地黃湯) 약침(藥鍼)이 혈압(血壓)에 미치는 영향(影響))

  • Shim, Yang-soo;Jeon, Moon-ki;Kim, Kyung-sik;Sohn, In-chul
    • Journal of Acupuncture Research
    • /
    • v.21 no.4
    • /
    • pp.1-18
    • /
    • 2004
  • Objective : This study was performed to investigate the effects of aqua-acupuncture of Jibaikjihwangtang in two-kidney one clip Goldblatt hypertensive rats and spontaneously hypertensive rats. Methods : we injected aqua-acupuncture solution into Shin-Soo ($BL_{23}$) which corresponds to human acupuncture point in two-kidney one clip Goldblatt hypertensive rats and spontaneously hypertensive rats. Systolic blood pressure, renin activity, aldosterone and atrial natriuretic peptide (ANP) plasma levels were tested. Results : Systolic blood pressure decreased significantly after aqua-acupuncture of jibaikjihwangtang. Acupuncture group in two-kidney one clip Goldblatt hyper-tensive rats had deference with control group. In plasma levels of atrial natriuretic peptide, acupuncture group of spontaneously hypertensive rats increased meaningfully but to two-kidney one clip Goldblatt hypertensive rats it was decreased meaningfully. In Serum Aldosterone density, the acupuncture group of spontaneously hypertensive rats had significant alteration than control group, but the acupuncture group of two-kidney one clip Goldblatt hypertensive rats had decreased alteration than control group. Conclusion : According to these results, after Aqua-Acupuncture of Jibaikjihwangtang blood pressure decreased significantly and data suggest that blood pressure reduction activity connected with renin activity reduction in renal hypertensive rat.

  • PDF

Improvement of ECG Measurement for the Elderly's U-healthcare Clothing Using 3D Tight-fit Pattern (3D패턴을 이용한 노인용 u-헬스케어 의복의 심전도 측정 연구)

  • Park, Hye-Jun;Shin, Seung-Chul;Shon, Boo-Hyun;Hong, Kyung-Hi
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.676-682
    • /
    • 2008
  • In this study a guideline of the 3D-fit pattern for the ECG(electrocardiogram) measurement of elderly's u-healthcare clothes was proposed. In the screening test of the ECG measurement band, ECG peak band was observable at the band pressure of 0.20 kPa. By employing a 3D body image, tight-fit 3D patterns were made at two different reduction rates of 21%(pattern 1) and 33%(pattern 2), and corresponding pressure of both of the clothes were 0.25 kPa and 0.54 kPa, respectively. Typical waves of ECG were found in both stationary and moving position. In terms of the subjective evaluation of the u-healthcare clothes when worn, it was confirmed that reduction pattern 1(0.25 kPa) conveyed comfortable clothing pressure and pleasantness, which is very close to the result of screening test of ECG band experiment. As results, it is recommended that reduction rate should be adjusted, so that clothing pressure is about 0.2 kPa for the elderly's comfortable and efficient u-healthcare clothes.

Development of Real-time Heart Rate Measurement Device Using Wireless Pressure Sensor (무선 압력센서를 이용한 실시간 맥박수 측정기 개발)

  • Choi, Sang-Dong;Cho, Sung-Hwan;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.284-288
    • /
    • 2016
  • Among the various physiological information that could be obtained from human body, heartbeat rate is a commonly used vital sign in the clinical milieu. Photoplethysography (PPG) sensor is incorporated into many wearable healthcare devices because of its advantages such as simplicity of hardware structure and low-cost. However, healthcare device employing PPG sensor has been issued in susceptibility of light and motion artifact. In this paper, to develop the real-time heart rate measurement device that is less sensitive to the external noises, we have fabricated an ultra-small wireless LC resonant pressure sensor by MEMS process. After performance evaluation in linearity and repeatability of the MEMS pressure sensor, heartbeat waveform and rate on radial artery were obtained by using resonant frequency-pressure conversion method. The measured data using the proposed heartbeat rate measurement system was validated by comparing it with the data of an commercialized heart rate measurement device. Result of the proposed device was agreed well to that of the commercialized device. The obtained real time heartbeat wave and rate were displayed on personal mobile system by bluetooth communication.

MICRO-SHEAR BOND STRENGTH TO DENTIN UNDER SIMULATED PULPAL PRESSURE (치수압이 상아질 접착제의 미세전단 결합강도에 미치는 영향에 관한 In vitro 연구)

  • Song, Yun-Jung;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.339-345
    • /
    • 2004
  • The aim of this study was to measure and compare the micro shear bond strengths of the following dentin bonding systems to the dentin surfaces under simulated pulpal pressure: All Bond $2^{\circledR},{\;}Second^{\circledR},{\;}AdheSE^{\circledR}$, Adper Prompt $L-Pop^{\circledR}$. The occlusal surfaces of 180 extracted human molars were prepared so the dentin bonding surfaces could be exposed. The teeth were randomly assigned to 3 equal groups of 60 each and subdivided. The dentin surfaces were treated with the above mentioned bonding system and resin composite cylinders were built up under a simulated pulpal pressure when saline (Group II) or diluted bovine serum (Group III) was used as the pulpal fluid. As a control. the same procedures were performed in the dried dentin surfaces (Group I). After one day of storage in water. the micro shear bond strengths were measured using an EZ tester. Group II and III showed significantly lower shear bond strength than Group I statistically (p < 0.05). $SEbond^{\circledR}{\;}and{\;}AdheSE^{\circledR}$ showed no difference among the different dentin condition. In the Adper Prompt $L-Pop^{\circledR}$. a simulated pulpal pressure were applied to the specimens using diluted bovine serum. which showed a higher strength than the specimens in which saline was used (p < 0.05).

Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (II): Optimal Design & Fabrication of Embedding-type PZT Module (바이오용 압전디스크방식 마이크로 펌프 설계 및 제작 (II) -임베드방식의 압전모듈의 최적설계 및 제작-)

  • Kim, Hyung-Jin;Chang, In-Bae;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.362-367
    • /
    • 2012
  • Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, most of the conventional micro pumps still have some limitations to miniaturize their controller system and to obtain the sufficient back pressure which can rise over the inner pressure of human body or experimental animals. In this paper, to overcome these limitation, a new PZT disc and its controller were designed and fabricated to get the sufficient flowrate and the back pressure with guaranteeing embeddability of the controller into pumping body. The amplitudes of the disc deflections were as large as 40 ${\mu}m$ at 200 V - 100 Hz condition. As results of experiments, the flow rate and the back pressure increase when the frequency increases. The obtainable maximum flow rate and back pressure are 5.2 ml/min at 95 Hz and 13.14 kPa at 90 Hz respectively.

Pressure Analysis of the Plantar Musculoskeletal Fascia Using a Fine Finite-Element Model (인체 족부 근골격계 상세 유한요소모델링을 통한 족저압 해석)

  • Jeon, Seong-Mo;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1237-1242
    • /
    • 2011
  • The A detailed 3D finite-element analysis model of a human foot has been developed by converting CT scan images to 3D CAD models in order to analyze the distribution of plantar pressure. The 3D foot model includes all muscles, bones, and skin. On the basis of this model and the pressure distribution results, shoes for diabetes patients, which can make the plantar pressure distribution uniform, may be designed through finite-element contact analysis.

Correlation Analysis of Parameters affecting Pressure Distributions in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트내 압력분포에 영향을 미치는 인자간 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.883-888
    • /
    • 2008
  • Various effluents generated in cooking processes contribute a great deal to indoor air pollution among many other indoor pollutants such as dusts from outdoor and carbon dioxide from human body. Kitchen exhaust hoods are not believed to exhaust indoor contaminants properly in many cases, while generating too much noise. Instead of focusing on individual products of kitchen hoods, we should address the problem by attacking the ventilation system as a whole including vertical shafts and building air-tightness. In this study, it is intended to investigate the pressure distribution along the vertical shaft depending on various system parameters, such as shaft size, concurrent hood usage rate, roof fan, inlet pressure loss, and outdoor temperature. The maximum static pressure in the vertical shaft has been obtained using the method of design of experiments and analyzed by the analysis of variance. The results can be used for the design of kitchen exhaust systems by analyzing the pressure distributions in vertical shafts.

  • PDF

The Development of a Functional Pressure Controller in Smoke Management Systems for the Fire Safety of Buildings (화재시 제연 및 피난을 위한 기능성 차압 조절장치 개발에 관한 연구)

  • Jung, Ki-Chang;Kim, Jeong-Hun;Lee, Jung-Yun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.44-48
    • /
    • 2004
  • The smoke and toxic gases generated from the building fires are proved to cause human death. Therefore, the necessity and significance of smoke control have been emphasized, and lots of studies for developing improved smoke management system have been carried out. In this study, the experiments were conducted to evaluated a function and performance in newly developed smoke management system using mechanical pressurization. As a result of this experiment, the differential pressure was 40Pa${\sim}$60Pa and the air velocity through the door was 0.7m/s between safety zone and fire zone. The functional pressure control equipment which could make proper pressure and maintain differential pressure between safety zone and fire zone was developed. And it will give a lot of helps to evacuation activity for peoples in building and fire fighting.

Power Supply of Ultrasonic Phased Array for Focus Control of Acoustic Pressure (음압 초점제어를 위한 초음파 위상배열의 전원 장치)

  • Jung, Hyung-Jon;Kim, Ui-Young;You, Bum-Jae;Choy, Ick
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.137-146
    • /
    • 2019
  • The ultrasonic phased arrays are used for treating tumors in the human body by the focus control of the acoustic pressure at the desired position. The magnitude and phase of the surface acoustic pressure in each ultrasonic transducer is controlled by the magnitude and phase of the applied voltage to it. In this paper, the relationship between the applied voltage and the surface acoustic pressure of the ultrasound transducer is modelled, and the desired voltage is realized by PWM technique. The validity of the proposed method is verified by computer simulation of the focus control of a ultrasonic phased array composed of 61 ultrasonic transducers.

Design of a Prototype Jacket for Upper Extremity Load Reduction (상지 부하 감소를 위한 기능성 상의 프로토타입 디자인)

  • Park, Sunhee;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.4
    • /
    • pp.613-623
    • /
    • 2022
  • This study developed a functional prototype jacket designed to reduce loads on the upper extremities of workers performing repetitive motions in the same posture for extended periods of time. Dynamic taping lines were applied to the upper extremities, and three dimensional (3D) supporters were inserted in the abdomen and back waist areas corresponding to the core muscles. Clothing pressure on the upper-extremity dynamic taping lines was set to two levels (proto P1 and proto P2), and the 3D supporters were designed in three types (proto FW, proto FW/BW, proto FW/BW/BBX). According to the subjective pressure perceived on each part of the upper extremities, the level proto P1 pressure was preferred. The proto FW/BW/BBX 3D supporter was rated as excellent, and the perceived pressure was ranked as satisfactory. The prototype jacket performed upper-extremity load reduction when the upper-extremity clothing-pressure level was set to 1.8 kPa, 2.1 kPa, and 2.4 kPa on the upper arm, forearm, and wrist regions, respectively, and when 3D supporters were installed in the abdomen and back of the waist with the addition of a back band.