• Title/Summary/Keyword: house intrusion

Search Result 6, Processing Time 0.021 seconds

A RodSecurityRobot Model (로드경비로봇 모델 연구)

  • Yang, Keyong-ae;Shin, Seung-Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.4
    • /
    • pp.401-406
    • /
    • 2018
  • According to the National Security Service of the National Police Agency, intrusion into empty houses increased form 2013 to 2016. Consequentially this statistics seemed that house intrusion, burglary is increasing. Also according to the statistics of Public Prosecutors'Office, a total 203,573 theft crimes occurered in 2016, of which 18.9% were theft after intruding. By reson of this is most frequent case of intrusion and theft, we have been studing the RodSecurityRobot model to enhance security in many factories to manage. In order to care for security to the high place, we have propsed a road guard robot model which controls the ground in cooperation with the robot that manages the ground by using the drones. The robot and the drone move together to autonomy to avoid objects. And they check time interval. they also goes to the charger to charge when there is no battery.

Security Monitoring System for Apartment House Building Using Paver Line Carrier (전력선 통신을 이용한 집단주택 안전관리 시스템)

  • Kim, In-Soo;Kim, Kwan-Ho;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

Development of Smart Kiosk for Controlling and Monitoring (제어 및 모니터링을 위한 스마트 키오스크 개발)

  • Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.160-164
    • /
    • 2022
  • In this paper, through the development of a smart panel (LCD kiosk) controller, contents to develop a system that can be operate in a desired environment by operating the window control and ventilation facilities according to the automatic controller operation based on the set values such as temperature, humidity, sunlight, and rainfall. In particular, the MQTT protocol-based sensor module can be directly manufactured and applied at any time based on various communication and power sources such as wireless, wired, and PLC (power line communication) to obtain the desired data, as well as fire, power failure, and intrusion in the house. It is also a system that enables operation and monitoring from a remote location based on the cloud environment by connecting sensors. Kiosks are currently being used in many places, and the demand for them is on the rise, and an active influx of young people can be expected through environmental improvement. It is expected to increase interest and understanding for improvement.

A Study of Radon Concentration in First Floor and Basement and Prediction of Annual Exposure Rate in Korea (국내 실내 라돈농도와 연간 피폭선량 예측에 관한 연구)

  • Lee, Jong-Dae;Kim, Yoon-Shin;Son, Bu-Soon;Kim, Dae-Seon
    • Journal of Environmental Science International
    • /
    • v.15 no.4
    • /
    • pp.311-317
    • /
    • 2006
  • The purpose of this study was to investigate Rn concentration and annual radiation exposure level in the basement and first floor. The Rn Cup monitors were placed in different environments such as shopping stage, office building, Apartment, Hospital, house in Seoul from Match 1996 to April 1997 and CR-39 films were collected every two months. The mean radon concentration in the basement of house($88.6\;Bq/m^3$) showed the highest level among the areas, while radon concentration on the first floor of house($50.5\;Bq/m^3$) showed the higher than other areas. The annual radiation exposure dose that person on the floor / in the basement of differential place in the seoul can be exposed during living was estimated from 24.11 to 87.64 mRem/yr. This radiation dose is significantly lower than 130mRem maximum radiation dosage from the radon nuclide prescribed by the ICRP, with respect to the overall average exposure of the working adult. this study indicated that possible radon sources on the first floor / in the basement areas are radon intrusion from soil gas, construction materials, or ground water leaking. Further study is needed to quantitatively assess major contributions of radon-222 and health effect to radon exposure.

LES of Turbulent Mixing of Non Reacting Flow in a Gas Generator

  • Lee, Chang-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.391-398
    • /
    • 2008
  • LES analysis was conducted with in-house CFD code to investigate the turbulence evolution and interaction due to turbulence ring and splash plate in the gas generator. Though chemical reaction was not accounted for, the results can be useful in determining the turbulence characteristics generated by ring and plate. The calculation results show that the installation of turbulence ring can introduce additional turbulences and improve turbulent mixing in the downstream flow. However, the addition of splash plate in the downstream of TR brings totally different shape of perturbation energy and enstrophy distribution for turbulent mixing. This enhancement can be done by the formation of the intensively strong vorticity production and mixing behind the plate. Pressure drop was found to be a reasonable level of about 1% or less of initial pressure in all calculation cases. Also, calculation results revealed that the variation of TR shape and intrusion length did not change the characteristics of turbulent mixing in the chamber. Even though the effect of installation location of splash plate on the turbulent mixing is not investigated yet, calculation results conclude the addition of splash plate leads to the increase in turbulent mixing with an acceptable pressure drop.

  • PDF

LES of Turbulent Mixing of Non-Reactive Flow in Gas Generator (가스발생기 비-반응 유동의 난류 혼합에 대한 LES 해석)

  • Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1171-1179
    • /
    • 2008
  • LES analysis was conducted with in-house CFD code to investigate the turbulence evolution and interaction due to turbulence ring and splash plate in the gas generator. The calculation results show that the installation of turbulence ring can introduce additional turbulences and significantly improve turbulent mixing in the downstream flow. However, the addition of splash plate in the downstream of TR(Turbulence Ring) brings totally different shape of perturbation energy and enstrophy distribution into turbulent mixing. This enhancement can be done by the formation of the intensively strong vorticity and mixing behind the plate. Pressure drop was found to be a reasonable level of about 1% or less of initial pressure in all calculation cases. Also, calculation results revealed that the variation of shape and intrusion length of TR did not greatly affect the characteristics of turbulent mixing in the chamber. Even though the effect of installation location of splash plate on the turbulent mixing was not investigated yet, calculation results conclude the addition of splash plate leads to the increase in turbulent mixing with an acceptable pressure drop.