• 제목/요약/키워드: hot-point

Search Result 666, Processing Time 0.031 seconds

Properties of Photoluminescience for AgInS2/GaAs Epilayer Grown by Hot Wall Epitaxy

  • Lee, Sang-Youl;Hong, Kwang-Joon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.2
    • /
    • pp.50-54
    • /
    • 2004
  • The AgInS$_2$epilayers with chalcopyrite structure grown by using a hot-wall epitaxy (HWE) method have been confirmed to be a high quality crystal. From the optical absorption measurement, the temperature dependence of the energy band gap on the AgInS$_2$/GaAs was derived as the Varshni's relation of E$\_$g/(T) = 2.1365 eV - (9.89${\times}$10$\^$-3/ eV/K) T$^2$/(2930+T eV). After the as-grown AgInS$_2$/GaAs was annealed in Ag-, S-. and In-atmosphere, the origin of point defects of the AgInS$_2$/GaAs has been investigated by using the photoluminescence (PL) at 10 K. The native defects of $V_{Ag}$, $V_s$, $Ag_{int}$, and $S_{int}$ obtained from PL measurement were classified to donors or accepters type. And, we concluded that the heat-treatment in the S- atmosphere converted the AgInS$_2$/GaAs to optical p-type. Also, we confirmed that the In in the AgInS$_2$/GaAs did not form the native defects because the In in AgInS$_2$did exist as the form of stable bonds.

A Study on Explosion Risk Management for Hot Oil Heater (열매체 가열기 설비에서의 폭발위험관리에 관한 연구)

  • Jang, Chul;Kwon, Jin-Wook;Hwang, Myoung-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.1-9
    • /
    • 2017
  • In the industrial field, various type of fuel have been used for product processing facilities. Recent for 10 years, the usage of natural gas (NG) was gradually increased. Because it has many merits; clean fuel, no transportation, storage facility and so on. There are common safety concept that strict explosion protection approaches are needed for facilities where explosive materials such as flammable liquid, vapor and gases exist. But some has an optimistic point of view that the lighter than air gases such as NG disperse rapidly, hence do not form explosion environment upon release into the atmosphere, many parts has a conventional safety point of view that those gases are also inflammable gases, hence can form explosion environment although the extent is limited and present. In this paper, the heating equipments (Hot Oil Heater) was reviewed and some risk management measures were proposed. These measures include hazardous area classification and explosion-proof provisions of electric apparatus, an early gas leak detection and isolation, ventilation system reliability, emergency response plan and training and so on. This study calculates Hazardous Area Classification using the hypothetical volume in the KS C IEC code.

CHANDRA X-RAY OBSERVATIONS OF EARLY TYPE GALAXIES

  • KIM DONG-WOO
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.213-222
    • /
    • 2003
  • We review recent observational results on early type galaxies obtained with high spatial resolution Chandra data. With its unprecedented high spatial resolution, Chandra reveals many intriguing features in early type galaxies which were not identified with the previous X-ray missions. In particular, various fine structures of the hot ISM in early type galaxies are detected, for example, X-ray cavities which are spatially coincident with radio jets/lobes, indicating the interaction between the hot ISM and radio jets. Also point sources (mostly LMXBs) are individually resolved down to Lx = a few x $10^{37}\;erg\;sec^{-1}$ and it is for the first time possible to unequivocally investigate their properties and the X-ray luminosity function. After correcting for incompleteness, the XLF of LMXBs is well reproduced by a single power law with a slope of -1.0 - -1.5, which is in contrast to the previous report on the existence of the XLF break at Lx, Eddington = 2 x $10^{38}\;erg\;sec^{-1}$ (i.e., Eddington luminosity of a neutron star binary). Carefully considering both detected and undetected, hidden populations of point sources we further discuss the XLF of LMXBs and the metal abundance of the hot ISM and their impact on the properties of early type galaxies.

Study point defect and growth for $CuInSe_2$ single crystal thin film by hot wall epitaxy (Hot Wall Epitaxy (HWE) 법에 의한 $CuInSe_2$ 단결정 박막 성장과 점결함 연구)

  • Yu, Sang-Ha;Hong, Gwang-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.152-153
    • /
    • 2007
  • $CuInSe_2$ single crystal thin film was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. After the as-grown $CuInSe_2$ single crystal thin films was annealed in Cu-, Se-, and In-atmospheres, the origin of point defects of $CuInSe_2$ single crystal thin films has been investigated by the photoluminescence(PL) at 10 K. The native defects of $V_{Cu}$, $V_{Se}$, $Cu_{lnt}$, and $Se_{lnt}$ obtained by PL measurements were classified as a donors or acceptors type. And we concluded that the heat-treatment in the Cu-atmosphere converted $CuInSe_2$ single crystal thin films to an optical n-type. Also, we confirmed that In in $CuInSe_2$/GaAs did not form the native defects because In in $CuInSe_2$ single crystal thin films existed in the form of stable bonds.

  • PDF

Upper Bound Analysis of Plane Strain Hot Strip Rolling Process (상계해석법을 이용한 평면변형 열간 판압연공정해석)

  • Moon, Young-Hoon;Chun, Myeong-Sik;Yi, Joon-Jeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.8
    • /
    • pp.2468-2479
    • /
    • 1996
  • An upper bound solution is obtained to perform the process analysis of hot strip rolling process. The material flows within the roll bite at various geometries and frictional conditions are obtained from finite element analysis and the typical flow pattern which is necessary to determine the kinematically admissible velocity field is assumed. From the kinematically admissible velocity field, the upper bound energy is calculated and the rolling load, angle of neutral point and forward slip ratio at various operational conditions are obtained from upper bound energy. The process analysis of above mentioned parameters at various operational conditions have provided valuable information which is hard to obtain during rolling operation and the predicted ranges of quantitive values from these analyses lie whthin the bound of actual operational data.

Effect of Galvanizing Furnace Temperature on Material Property and Galvanized Surface of Hot Rolled Galvanized Steel

  • Jong Chan Jeong;Jae Joong Kim;Seong Ho Han
    • Corrosion Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.278-282
    • /
    • 2024
  • Recently, hot rolled galvanized steel is widely used in automotive parts. As the paradigm of the automotive market has changed from fossil fuel vehicle to electric vehicle, the automotive industry needs more high-strength steels to reduce weights of automobiles. However, because high-strength steel contains high solute carbon, it is expected to have a risk of stretcher-strain on the surface due to dislocation trapping by solute [C] and [N]. Generally, galvanized steel is supposed to pass through a furnace around the temperature of Zinc pot to increase material temperature. Otherwise, the inhibition layer could not be formed. However, solute carbon and nitrogen are volatile enough to move around the furnace temperature. Moreover, the ratio of ferrite phase and precipitated Fe3C can be variable, resulting in yield point elongation related to the stretcher strain. Furthermore, the quality of the galvanized surface can be affected by a high temperature of the furnace. Although a relatively hot rolled galvanizing line furnace has a lower temperature than an annealing line furnace, it can affect various quality aspects. In other words, this paper aims to determine how these phenomena appear concerning furnace temperature.

Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood (합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度))

  • Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF

An Experimental Study on the Characteristics of Temperature Separation for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브에서의 형상 변화에 따른 온도 분리에 관한 실험적 연구(I))

  • 황승식;전운학;김종철;이희상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial temperature distribution and the radial temperature distribution in internal space of a tube. From the study, following conclusive remarks can be made. Average flow rate that flows into a tube is in proportion to square root of inlet pressure. As inlet pressure increases axial and radial temperature distribution in the inner space of vortex-tube increase. As mass flow rate ratio change, separation point moves.

  • PDF

Experimental Study on the Unsteady Flow under Various Operating Conditions of a Counter Rotating Axial Flow Fan (엇회전식 축류팬의 작동조건 변화에 따른 비정상 유동에 관한 실험적 연구)

  • Kang, Hyun-Koo;Cho, Lee-Sang;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1389-1394
    • /
    • 2004
  • Experiments were done for the unsteady flow in a counter rotating axial flow fan near peak efficiency and stall point. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional passage flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Comparison of flow characteristics between two different operating conditions such as tip vortex, secondary flow and turbulence intensity were performed through the analyses of axial, radial and tangential velocity distributions. As a result, tip vortex and secondary flows are enforced and measured obviously at stall point.

  • PDF

Output Property of Ge-Thermopile Sensor (Ge계 열전센서의 출력특성)

  • Park, Su-Dong;Kim, Bong-Seo;Oh, Min-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.265-266
    • /
    • 2006
  • It was well known that thermopile was quiet a competent sensor using to probe the temperature of "hot point" where the temperature can be off the temperature-limitation for normal operation of the main electrical power equipment. In the present work, we aimed for developing new Ge-thermopile materials which can be using a non-contact temperature sensors at various hot-point of the power equipment and evaluation of its output property. As a results of the present works, a new thermopile which were composed Ga-poded p-type and Sb-doped n-type in Ge-semiconductor were designed and manufactured by MBE(Molecular Beam Epitaxy) process and showed superior sensitivity at room temperature.

  • PDF