• Title/Summary/Keyword: hot wires

Search Result 45, Processing Time 0.022 seconds

Performance Characteristics of a V-type Probe Developed for Wall Vorticity Measurement (벽와도 측정을 위하여 개발된 V형 열선 프로브의 성능특성)

  • Kim, Seong-Uk;Ryu, Sang-Jin;Yu, Jeong-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.514-522
    • /
    • 2001
  • In order to investigate the relation between wall vorticity and streamwise velocity fluctuations in a turbulent boundary layer, a wall vorticity probe has been developed, which consists of two hot-wires on the wall aligned in V configuration. Although the measured intensity of spanwise wall vorticity fluctuations is somewhat lower than previous results, the intensity of streamwise wall vorticity fluctuations is in good agreement with them. It has been shown that the measured intensity of spanwise wall vorticity fluctuations is affected by transverse length of the wall vorticity probe. Instantaneous streamwise and spanwise wall vorticity fluctuations are compared with the results of DNS. Probability density function of spanwise wall vorticity fluctuations shows good agreement with previous results and is different from that of streamwise wall vorticity fluctuations. Energy spectrum of streamwisw wall vorticity fluctuations is lower than that of spanwise wall vorticity fluctuations in low frequency region.

Measuring Convective Heat Transfer Coefficients of Nanofluids over a Circular Fine Wire Maintaining a Constant Temperature (등온으로 유지되는 가는 열선주위를 흐르는 나노유체의 대류열전달계수 측정실험)

  • Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • This paper describes a measuring apparatus that can be used to appraise the effectiveness of nanofluids as new heat-transfer-enhancing fluids. A couple of apparatuses using fine hot wires as sensors have been proposed for this purpose; however, they have a technical weakness related to the uncertain working conditions of the sensor. The present method uses the convective heat transfer coefficient from a hot wire as an indication of the heat transfer effectiveness of the nanofluid, where the temperature of the wire remains constant during the experiment. The operating principle and experimental procedure are explained in detail, and the validity of the system is tested with pure base fluids. The effects of particle concentration, velocity, and temperature on the heat transfer coefficients of the nanofluids are discussed comprehensively using the experimental data for graphite nanolubrication oil.

Ultrasonic Transducer Application for Nondestructive Testing of Continuous Cast Billets (연주빌렛의 비파괴 검사를 위한 초음파 센서의 응용)

  • Shin, Byoung-Chul;Kwon, Jeong-Rock
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.25-31
    • /
    • 1996
  • Steel wires are made by elongating hot billets. If the billets have internal or surface defects, the wire can be broken during elongation process. After testing surface defect, we are testing internal defect by ultrasonic transducers. POSCO is producing two kinds of billets, hot rolled billet and cast billet. Hot rolled one is denser than cast billet. Because of the low density and rough surface, ultrasonic testing is difficult for the cast billet. Size of the transducer was related with the size and density of the billet. A transducer having 21mm long, 8.5mm wide and 0.95mm thick piezoelectric ceramic plate was best for $160mm\;{\times}\;160mm$ cast billet. Center frequency of the transducer was 2.25MHz and the focus distance was 70mm.

  • PDF

Fabrication of a-Si:H/c-Si Hetero-Junction Solar Cells by Dual Hot Wire Chemical Vapor Deposition (양면동시증착 열선-CVD를 이용한 a-Si:H/c-Si 이종접합 태양전지 제조)

  • Jeong, Dae-Young;Song, Jun-Yong;Kim, Kyung-Min;Lee, Hi-Deok;Song, Jin-Soo;Lee, Jeong-Chul
    • Korean Journal of Materials Research
    • /
    • v.21 no.12
    • /
    • pp.666-672
    • /
    • 2011
  • The a-Si:H/c-Si hetero-junction (HJ) solar cells have a variety of advantages in efficiency and fabrication processes. It has already demonstrated about 23% in R&D scale and more than 20% in commercial production. In order to further reduce the fabrication cost of HJ solar cells, fabrication processes should be simplified more than conventional methods which accompany separate processes of front and rear sides of the cells. In this study, we propose a simultaneous deposition of intrinsic thin a-Si:H layers on both sides of a wafer by dual hot wire CVD (HWVCD). In this system, wafers are located between tantalum wires, and a-Si:H layers are simultaneously deposited on both sides of the wafer. By using this scheme, we can reduce the process steps and time and improve the efficiency of HJ solar cells by removing surface contamination of the wafers. We achieved about 16% efficiency in HJ solar cells incorporating intrinsic a-Si:H buffers by dual HWCVD and p/n layers by PECVD.

Hot Firing Test of a Quadrature NEA SSD9103S1 Configuration

  • Ja-Chun, Koo;Hee-Sung, Park;Max, Guba
    • International Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.1-9
    • /
    • 2022
  • The NEA release mechanism is used to provide restraint and release functions with low shock for critical deployment operations on solar arrays after launch. The GK3 solar array consists of 2 wings and 6 hold down points per panel. The NEA SSD9103S1 is a part of the GK3 solar array hold-down and release mechanism. Each NEA unit is equipped with two Z-diodes which provide power to a NEA unit connected in series after actuation of the fuse wire. This paper presents the hot firing test results of a quadrature NEA SSD9103S1 configuration. One output powers a maximum of 4 NEA SSD9103S1 units simultaneously. The necessary actuation pulse duration has been determined to meet margin requirement for thermal energy of minimum 4. Actuation thermal energy difference is about 6.6% between each half of two fired serial NEAs. Thermal energy margin at worst case is minimum 5.9 in case of an actuation pulse duration of 500 ms. Two series Zener impedance depend on current applied has been characterized by an additional actuation after all fuse wires are open circuit. Total number of actuation commands to the GK3 NEA unit reduce drastically from 24 in case of single NEA configuration down to 8 in case of parallel and quadrature NEA configurations. It can be accommodated by the existing HP2U Pyro design without any impact.

Turbulent Flow Field on Boundary Layer Flow Conditions in the Near-Wake of a Flat Plate (평판 근접 후류에서 경계층의 유동조건에 따른 난류유동장)

  • Kim, D.H.;Chang, J.W.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.12 no.3
    • /
    • pp.25-39
    • /
    • 2004
  • An experimental study was quantitatively carried out in order to investigate the influence of flow conditions on a boundary layer in the near-wake of a flat plate. Tripping wires attached at various positions were selected to change flow conditions of a boundary layer in the vicinity of trailing edge. The flows such as laminar, transitional, and turbulent boundary layer at 0.98C from the leading edge are imposed to investigate the evolution of symmetric and asymmetric wake. Measurements were made at freestream velocity of 6.0m/s, and the corresponding Reynolds number is $2.8{\times}10^5$. An x-type hot-wire probe(55P61) was employed to measure at 8 stations in the near-wake region. Test results show that the near-wake of the flat plate for the case of a laminar and transitional boundary layer is sensitive to mean flow shear generated after separation but for the case of turbulent boundary layer is insensitive.

  • PDF

Experimental Study of Wall Pressure Fluctuations in the Regions of Flow Transition (천이 경계층 유동의 벽면 변동 압력에 관한 실험적 연구)

  • 홍진숙;전재진;김상윤;신구균
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.4
    • /
    • pp.280-286
    • /
    • 2002
  • It has been long suspected that the transition region may give rise to local pressure fluctuations and radiated sound that are different from those created by the fully-developed turbulent boundary layer at equivalent Reynolds number. Experimental investigation described in this paper concerns the characteristics of pressure fluctuations at the transition. Flush-mounted microphones and hot wires are used to measure the pressure fluctuations and local flow velocities within the boundary layer in the low noise wind tunnel. From this experiment we could observe the spatial and temporal development process of T-S wave using Wigner-Ville method and find the relations between the characteristic frequency of T-S wave and free stream velocity and the boundary layer thickness based on nondimensional pressure spectra scaled on outer variables.

A Study on the Earthing System (접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Myeong-Saeng;Kim, Chang-Bong;Woo, Jea-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.375-378
    • /
    • 2009
  • This paper will arrange and classify the earthing system by the latest developed technique tendency, and suggest how to solve the problem of a current earthing system. The 3rd generation earthing system is environment-friendly and designed to use discharge electrodes, catalysts and heat rays. A discharge current has increased by 31 [A] in the 3rd generation of earthing system compared to the 2nd one and it is 25 times faster. This system is not buried under but built on the ground. It solves the problems that the current system has; expenses, time, area and pollutions followed by the construction.

  • PDF

Experimental Study of Wall Pressure Fluctuations in the Regions of Flow Transition (천이 경계층 유동의 벽면 변동 압력에 관한 실험적 연구)

  • Shin, Ku-Kyun;Hong, Chin-Suk;Jeon, Jae-Jin;Kim, Sang-Yoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.811-816
    • /
    • 2000
  • It has been long suspected that the transition region may give rise to local pressure fluctuations and radiated sound that are different from those created by the fully-developed turbulent boundary layer at equivalent Reynolds number. Experimental investigation described in this paper concerns the characteristics of pressure fluctuations at the transition. Flush-mounted microphones and hot wires are used to measure the pressure fluctuations and local flow velocities within the boudary layer in the low noise wind tunnel. From this experimental we could observe the spatial and temporal development process of T-S wave using Wigner-Ville method and found the possibility of relation between the characteristic frequency of T-S wave and free stream velocity and the boundary layer thickness based on nondimensional pressure spectra scaled on outer variables.

  • PDF

Fabrication and properties of Nb$_3$Sn superconducting wire from large billet stage (대형 빌렛 제조에 의한 Nb$_3$Sn 초전도 선재의 가공 및 특성 연구)

  • 하동우;오상수;하홍수;이남진;권영길;류강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.806-809
    • /
    • 2000
  • A key technology for achieving commercial Nb$_3$Sn superconducting wires may be driven from fabrication Process of big-scale billets. Sub-element billet with diameter of 200 mm was designed and fabricated. This billet was hot-extruded and drawn. Cu stabilizer tube, Nb barrier tube and 19 sub-elements inserted Sn core were composed for strand. There was no breakage in the strand that was constituted with annealed sub-element. It was need that billet had to treat HIP because of remove of voids and goad contact between Cu and Nb filaments. Ta wound sheet was better than Ta tube thor barrier in the strand. Ic of the Nb$_3$Sn wire at 127, 4.2K was over than 120 A.

  • PDF