• Title/Summary/Keyword: hot plate methods

Search Result 82, Processing Time 0.025 seconds

A New Hot-Plate Method using Threshold Temperature; its Application on the Study of the Interaction between Naloxone or Diazepam and Morphine (신열판실험방법(新熱板實驗方法)에 의(依)한 Naloxone과 Diazepam이 Morphine 진통효과(鎭痛效果)에 미치는 영향(影響)에 관(關)한 검색(檢索))

  • Moon, Young-Hwan;Chun, Boe-Gwun
    • The Korean Journal of Pharmacology
    • /
    • v.18 no.2
    • /
    • pp.45-50
    • /
    • 1982
  • Yeum et al. formulated a new hot-plate method using the threshold temperature, and there are some controversies on the effects of naloxone and diazepam on the antinociceptive action. In this paper, the comparison of three methods registering analgesic activity and the application of the new hot-plate method formulated by Yeum et al. on the study of the influences of naloxone and diazepam on the analgesic effect of morphine were tried in male mice. The results obtained were summarized as follows; 1) The least-square regression lines of the morphine analgesia plotted against log-dose showed the correlation coefficient of above 0.90, but the competitive antagonism produced by naloxone (0.1 mg/kg) against the analgesia was more prominently demonstated by the new hot-plate method than the other methods: original hot-plate method and electrical stimulation method. 2) In the experiment using the new hot-plate method, the log dose-response curve of morphine (y=7.30 x+49.80, r=0.998) was shifted to the right by the pretreatment of naloxone (0.1 mg/kg), but was slightly shifted to the left by the pretreatment of diazepam (2.5 mg/kg). This study suggests that for the analgesia experiment, the new hot-plate method is superior to the original hot-plate method or the electrical stimulation method, and that the potentiative effect of diazepam on the morphine anagesia is not significant.

  • PDF

FE-Analysis of Hot Forming of Al Large Thick Plate for Spherical LNG Tank Considering Cooling Performance of Grid-Typed Die (격자형 금형의 냉각효과를 고려한 구형 LNG 탱크용 대형 알루미늄 후판의 열간성형해석)

  • Lee, Jung-Min;Lee, In-Kyu;Kim, Dae-Soon;Kwon, Il-Keun;Lee, Seon-Bong;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1190-1198
    • /
    • 2012
  • A hot forming of large thick Al plate using a grid-type hybrid die is a process to make a shell plate for the production of a spherical LNG tank. This process is characterized by using a grid-typed die with an additional air cooling system for reducing the cooling time of the heated plate after hot forming. The process consists of the plate's feeding, heating, forming and cooling in detail and each of them is continuously performed along the rail. This paper was designed to propose the analytical and experimental methods for determining the convection and interfacial heat transfer coefficients required in hot forming analysis of Al plate. These values in the analysis are to reproduce numerically the cooling performance of grid-typed die and cooling device. Interfacial heat transfer was obtained from the heat transfer experiments for different pressures and inverse analysis method. To verify the efficiency of the coefficient values obtained from above methods, FE analysis and experiment of the hot spherical-forming process were conducted for a small-scaled model. The convection coefficient was also calculated from flow analysis of air released by cooling device within grid-typed die using ANSYS-CFX.

Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation (도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가)

  • Lee, Byung-Kyu;Lee, Ji-Tae;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

Evaluation of CO2 desorption efficiency of scrubber absorption system in Liquor Plant (주류공정 내 흡수시스템 CO2 탈리 효율 평가)

  • Park, Il-Gun;Park, Hyung-June;Lee, June-Hyung;Kim, Heung-Rae;Lee, Ju-Yeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.173-182
    • /
    • 2020
  • In this study, amino acid salt absorbents were applied to remove and capture high concentrations of CO2 in liquor factories and regeneration performance was confirmed. In order to evaluate the effective treatment of the desorption process, two methods(Hot plate and Steam) were compared at the laboratory scale. As a result, hot plate and Steam. Hot plate methods regeneration efficiency was about 10% and Steam methods was about 60%. The Steam-Tower condition was evaluated by installing a 100㎥/min flow rate scrubber absorption system in the liquor factory. As a result, it was established that the absorbent flow rate was below 4L/min and the steam temperature was above 160℃. Finally regeneration performance was confirmed as 85.5%.

Effect of Manufacturing Condition on the Physical Properties of TTD Yarns with Hot Plate Device (Hot Plate장치를 이용한 TTD사 제조조건에 따른 사의 물성변화 연구)

  • Song, Min-Kyu;Kim, Hi-Dong;Kwon, Oh-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.2
    • /
    • pp.247-251
    • /
    • 2005
  • In this the study, the effects of the manufacturing process conditions on the properties Thick and Thin Diameter yarns(TTD yarns) prepared with hot plate device in the draw winder were determined. Physical properties including wet shrinkage, tenacity and elongation of the samples were measured and thick and thin effect was analysed with the evenness tester. The results were as the follows: There was little change the wet shrinkage of the TTD yarns in the range of $70^{\circ}C{\sim}80^{\circ}C$ of $R_1$ temperature(lower hot cylinder) with the same Hot Plate(H/P) temperature, but the wet shrinkage of the TTD yarns decreased 5-10% when $R_1$ temperature was $90^{\circ}C$. The wet shrinkage of the TTD yarns decreased with the H/P temperature at the same temperature of $R_1$. There was little effect of $R_1$ and H/P temperature on the tenacity of TTD yarns. The elongation of TTD yarns increased with $R_1$ temperature at the same H/P temperature. The elongation of TTD yarns increased little bit for the first time and then decreased above that temperature with increasing H/P temperature at the same $R_1$ temperature. The thick and thin effect on the TTD yarns was obvious in $110^{\circ}C$ of H/P temperature regardless of $R_1$ temperature, while there was no thick and thin effect on the TTD yarns in $140^{\circ}C$ of H/P temperature.

Development of remote RW technology for fuel multi-pin fabrication (핵연료 멀티핀 제조용 원격 저항용접기술 개발)

  • Kim, Su-Seong;Gu, Dae-Seo;Lee, Jeong-Won;Park, Geun-Il;Jo, Dae-Sik
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.89-91
    • /
    • 2006
  • An analysis of a multi-pin remote welding for a DUPIC fuel fabrication was made to establish the optimum welding processes in a hot cell environment. An initial investigation for hands-on fabrication outside the hot cell was performed, and the constraints of a hot cell welding were considered. Preliminary welding performances to improve the RW process were also examined. The RW process was determined to be the best in a hot cell environment for joining the end plate to the end caps. This paper presents an outline of the developed RW machine for a DUPIC fuel fabrication and compares the characteristics of a Zr-4 end plate welding by using electrical resistance and LB methods. The weld nuggets of RW specimens and torque strengths of resistant and LB welded zones were also investigated.

  • PDF

Experimental Study on Measuring the Intermittency in the Transitional Boundary Layer (천이경계층에서의 간헐도 측정에 관한 실험적 연구)

  • 임효재;안재용;백성구;정명균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • An experimental study was performed to investigate the turbulence intermittency measuring methods across the boundary layer in the transition region. A single type hot-wire probe was used to measure instantaneous streamwise velocities in laminar, transitional and turbulent boundary layer To estimate wall shear stresses on the flat plate, near wall mean velocities are applied to the principle of CPM. Distribution of intermittency factor is obtained by dual-slope method and compared to the results of four methods,$\'{u},\;\{U}$, TERA and M-TERA method. In these methods, M-TERA shows a good agreement in the near wall region. However, the result of M-TERA method shows that intermittency factor is underestimated in the outer part and outside of the boundary layer and the dimensional constant of M-TERA method should be changed appropriately depending on measuring point.

The Effect of Extraction Conditions and Film Side on the Molecular Conformation of Silk Sericin Film

  • Jo, Yoon Nam;Bae, Do Gyu;Um, In Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.26 no.2
    • /
    • pp.113-118
    • /
    • 2013
  • In this study, silk sericin films were prepared using different extraction methods, and the molecular conformation of sericin was examined using Fourier-transform infrared spectroscopy with attenuated total reflection geometry. Additionally, the effect of the film side (air-facing side or plate-facing side) on the molecular conformation of the sericin films was investigated. Interestingly, the molecular conformation of the sericin film depended on the film side. The molecular conformation of air-facing side of the sericin film was significantly influenced by extraction solution and time. The ${\beta}$-sheet crystallization and the crystallinity index of the sericin film markedly increased with an increase in the extraction time in hot water. The order of the crystallinity indices for the sericin films obtained with different extraction solutions was as follows: citric acid solution > urea solution >> hot water. In contrast, no remarkable differences were observed in the molecular conformation of the plate-facing side of the sericin film after extraction in hot water for different time periods. Urea and citric acid solution extractions showed remarkably higher crystallinity indices for sericin than those obtained after hot water extraction. However, no significant differences were observed in the crystallinity index of sericin between urea and citric acid solution extraction in plate-facing side of the film.

The Analgesic Effect of Aconitum Sinomontanum Nakai Pharmacopuncture in Sprague-Dawley Rats

  • Lee, Jung Hee;Lee, Yun Kyu;Lee, Hyun-Jong;Kim, Jae Soo
    • Journal of Acupuncture Research
    • /
    • v.38 no.2
    • /
    • pp.140-145
    • /
    • 2021
  • Background: Aconitum sinomontanum Nakai (ASN) has been reported to have analgesic effects. In this study an animal model of pharmacopuncture using ASN (100-500 mg/kg) was examined. Methods: Sprague-Dawley (SD) rats (n = 40) were randomly assigned to ASN-Low (1 mg/mL, 1.8 mL, ASN-L), ASN-Intermediate (5 mg/mL, 1.8 mL, ASN-M), ASN-High (10 mg/mL, 1.8 mL, ASN-H), negative control (0.2 mL normal saline), and positive control (0.2 mL 0.5% lidocaine) groups. All experiments were administered to the rats' left hind leg. The analgesic response was assessed by monitoring the physical (hot plate, and von Frey test) and chemical (formalin) responses to pain. Results: All ASN pharmacopuncture groups demonstrated significant differences in pain response to the hot plate test, von Frey test, and formalin test, compared to the control group (p < 0.05). The response of the ASN-M group and ASN-H groups to the hot plate, the formalin, and the von Frey tests were significantly different, compared to the lidocaine group (p < 0.05). Conclusion: ASN pharmacopuncture had a significant analgesic effect on SD rats in response to physical and chemical models of pain.

Experimental Study on Correction of Thermal Conductivity Obtained by Heat Flow Method using Commercial Guarded Hot Plate Method Apparatus (상용 보호열판법 열전도율 측정장비를 사용한 열유속법의 열전도율 값 보정에 대한 실험적 연구)

  • Lee, Jin-Sung;Kim, Kyung-Su;Kim, Yooil;Woo, Suck-Min;Yun, Seungjin
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.169-174
    • /
    • 2015
  • This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.