• 제목/요약/키워드: hot air heating

검색결과 331건 처리시간 0.027초

Effects of Surface Radiation on the Unsteady Natural Convection in a Rectangular Enclosure

  • Baek, Seung-Wook;Kim, Taig-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권1호
    • /
    • pp.95-104
    • /
    • 2002
  • Numerical solution of the full Navier-Stokes equation as well as the energy equation has been obtained for the unsteady natural convection in a rectangular enclosure. One side wall was maintained at very high temperature simulating fires. Especially the effect of surface radiation was taken into account. While the enclosed air was assumed to be transparent, the internal walls directly interacted one another through the surface radiation. Due to a significant temperature difference in the flow field, the equation of state was used instead of the Boussinesq approximation. It was found that the rapid heating of the adiabatic ceiling and floor by the incoming radiation from the hot wall made the evolution at thermo-fluid field highly unstable in the initial period. Therefore, the secondary cells brought about at the floor region greatly affected the heat transfer mechanism inside the enclosure. The heat transfer rate was augmented by the radiation, resulting in requiring less time for the flow to reach the steady state. At the steady state neglecting radiation two internal hydraulic jumps were clearly observed in upper/left as well as in lower/right comer. However, the hydraulic jump in the lower/right comer could not be observed for the case including radiation due to its high momentum flow over the bottom wall. Radiation resulted in a faster establishment of the steady state phenomena.

원판(圓板)의 열판건조(熱板乾燥)에서 컴퓨터 시뮬레이션에 의한 내부온도(內部溫度)와 함수율(含水率) 분포모형(分布模型) (Distribution Model Based on Computer Simulation for Internal Temperature and Moisture Content in Press Drying of Tree Disks)

  • 여환명;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제22권2호
    • /
    • pp.61-70
    • /
    • 1994
  • This study was executed to find the applicability of press drying of tree disk by investigating the shrinkage and drying defect and to form appropriate model by comparing the actual moisture content(MC) and internal temperature in respect of drying time with calculated values based computer simulation to which was applied finite difference method. In press drying disk, heating period, constant drying rate period maintained plateau temperature at 100$^{\circ}C$ and falling drying rate period were significantly distinguished. Actual MC and internal temperature were analogous to those calculated at comparing points. Heat transfer model formed by Fourier's law using specific heat of moist wood and conduction coefficient considering fractional volume of each element of wood cell wall, bound water, free water and air showed applicability as basic data to developing heat expansion, shrinkage and drying stress during press drying. Also mass transfer model formed by Fick's diffusion law using water vapor diffusion coefficient showed applicability. Longitudinal shrinkage was developed by pressure of hot press and tangential shrinkage was restrained by hygrothermal recovery. The heart check, surface check and ring failure were occurred differently in species, but V-shaped crack didn't develop.

  • PDF

내부가열을 이용한 보장성어육(고등어) 연제품의 가공 및 제품개발에 관한 연구 2. 제품저장중의 품질변화 (Processing of Water Activity Controlled Fish Meat Paste by Dielectric Heating 2. Storage Stability of the Product)

  • 이강호;이병호;유병진;서재수;조진호;정인학;제외권
    • 한국수산과학회지
    • /
    • 제17권5호
    • /
    • pp.361-367
    • /
    • 1984
  • In previous paper(Lee et al., 1984), preparation formula and processing conditions of the fish meat (mackerel) paste using dielectric heating were described, that included the proper shape and size of product and the conditions of dielectric heating, hot air dehydration, and heating with electric heater to yield the minimum expansion and case hardening during heating and to controll the final rater activity of 0.86 to 0.83 accompanying with a complete reduction of viable cells and good texture. In present study, changes in VBN, pH, total plate count, water activity, texture, the loss of available lysine, color indexes, TBA value, and the content of TI were determined to assess the quality stability and shelf-life of the product during the storage for 35 days at $5^{\circ}C\;and\;25^{\circ}C$, respectively. And the effect of vacuum sealing and hot water treatment before storage on the storage stability of product was also mentioned. As the product was vacuum packed in K-flex film bag, heat treated in boiling water for 6 minutes, and stored, water activity was maintained 0.86 to 0.84 for 35 days regardless of storage temperature, and the increase of total plate count was negligible in case of $5^{\circ}C$ storage while tended to gain slightly after 25 days at $25^{\circ}C$ storage. Changes in VBN was also minimum with an increase of 1.5 mg/100g at $5^{\circ}C$ and 7.0mg/100g at $25^{\circ}C$, but in case of unpacked sample, it was 24.5mg/100g at $5^{\circ}C$ and 42.4 mg/100g at $25^{\circ}C$ even after 7 days. In textural property hardness tended to increase after 28 days and folding test score was down to A or B from AA grade. The loss of available lysine was $7.5\%\;at\;5^{\circ}C$ and $17.0\%\;at\;25^{\circ}C$ but brown color was not deeply developed as the color index score indicated. TBA value was not increased at $5^{\circ}C$ while it tended to increase rapidly after 30 days at $25^{\circ}C$. Changes in TI content was not obvious except that it showed a tendency of increase at the end of storage as well as in the change of lysine and TBA value. It is concluded from the results that the quality of the product, pasteurized and water activity controlled by dielectric heating, and vacuum packed in K-flex film would be stable for more than 35 days at $5^{\circ}C$ and at least 25 days even at room temperature.

  • PDF

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.

하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구 (A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage)

  • 김지영;백영진;이영수;장기창;나호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF

부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions)

  • 최성경;이상헌;김선재;김용찬
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

저온 외기조건에서 케스케이드 급탕열펌프의 성능특성에 관한 해석적 연구 (Numerical Study of the Performance Characteristics of a Cascade Heat Pump Water Heater at Low Ambient Temperatures)

  • 송재현;정해원;박재우;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권5호
    • /
    • pp.225-232
    • /
    • 2013
  • Heat pump systems have been widely adopted in buildings for cooling and heating, due to their higher energy efficiency. Recently, the demand for hot water supply from the heat pump system has been increasing. To increase the water supply temperature with higher system efficiency and reliability, a heat pump water heater adopting cascade cycle was investigated in this study. The cascade heat pump water heater consisted of a low-stage cycle using R410A, and a high-stage cycle using R134a. A simulation program for the cascade heat pump water heater was developed, and verified by comparison with experimental data. The performance of the cascade heat pump water heater was optimized, by varying the compressor rotating speeds of the low- and high-stage cycles. At low ambient temperatures, the performance of the cascade cycle was compared with that of the single-stage cycle. The system efficiency of the cascade cycle was higher than that of the single-stage cycle, showing a lower compression ratio and compressor discharge temperature.

호주인과 호주 교민의 주거문화 비교를 위한 기초 연구(I) -호주 교민의 주생활 분석을 중심으로 - (A Baseline Study on Housing Cultures for Cross-Cultural Comparison between Korean- Australians and Australians(I) : An Analysis of Housing Cultures of Korean- Australian Families.)

  • 이영심;이상해
    • 가정과삶의질연구
    • /
    • 제23권2호
    • /
    • pp.107-125
    • /
    • 2005
  • Each ethnic group has a different cultural background and has developed its own culture in the name of a tradition. The interaction between different cultures is ever increasing through the process of acculturation or culture contact The purpose of this study is to provide baseline information about domestic living of Korean immigrants in Australia and Australians for a larger cross-cultural study project. As the first step, the usage of domestic space and seating styles of 52 Korean households in Melbourne were analyzed. Ethnographic research was conducted, utilizing a questionnaire. The findings of this research are as follows: 1. The most popular type of Living-Dining-Kitchen arrangement was the one which the kitchen is separated from the living and dining area. The level of satisfaction was the highest when the living room, dining room, and kitchen were all separated. 2. A laundry room was indispensable for Koreans in Australia, and they wanted to dry laundry and do ironing in there. Most people were satisfied with the toilet separated from the bathroom A drain hole on the floor of the bathroom was not indispensable for most Korean-Australians. 3. Korean-Australians tend to engage in various activities in their individual rooms, and they estimated that the size of most rooms were small. They also wanted to renovate the house to expand the rooms. 4. The seating style of Korean-Australians was mostly chair-seating. Yet, they often made beds on the floor for guests, and made kimchi sitting on the floor. Also, when they were relaxing, they were using both chair-seating and floor-seating. 5. Korean-Australians were not very satisfied with the use of floor carpets because of the dust collected on the carpets, and the difficulty to clean. It may be related to their preferred floor seating style, as well. 6. Almost all Korean-Australians take off their shoes inside of the house for hygienic reasons. They had a shoes cabinet at the entrance inside of the house. 7. The most popular heating system was ducted heating. The level of satisfaction about this was moderate because hot air contains lots of dust and it makes rooms very dry. Many were using electric blankets and their desired heating system was Ondol (heated floor). 8. Korean-Australians thought that the living room was the most important place for the family, and believed it should be decorated well to entertain guests. They also pointed out that the lighting was not bright enough in general.

영구형 큰느타리버섯 재배사의 환경요인 분석 (Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure)

  • 윤용철;서원명;이인복
    • 생물환경조절학회지
    • /
    • 제15권2호
    • /
    • pp.125-137
    • /
    • 2006
  • 본 연구에서는 큰느타리버섯 재배사의 환경조절을 최적화하고 시스템 설계에 대한 기초자료를 얻기 위하여 진주인근에 위치한 샌드위치패널을 이용한 영구형 재배사 2동을 대상으로 2003년 11월부터 2005년 10월까지 재배사 내부에서 측정한 환경인자들을 중심으로 검토하였다. 실험지역의 외기온은 평년의 것과 대체로 비슷한 경향을 보였다. 시스템 변경전의 경우, 동절기에는 전체적으로 설정온도보다 낮게 유지되었고, 또 최상부와 최하부의 최대온도 편차도 $5.1^{\circ}C$ 정도로 상층이 가장 높게 나타났다. 그러나 시스템의 변경 후의 경우, 난방시 대체로 설정온도 범위에서 조절되는 경향을 보였고, 공기정체나 온도층의 역전현상이 나타나지 않았다. 상대습도는 시스템 변경 후, $80{\sim}100%$ 정도의 범위로서 권장상대습도 범위에 있었다. 전체 재배기간동안 탄산가스 농도는 $400{\sim}3,300mg{\cdot}L^{-1}$ 정도의 범위에 있었다. 조도는 권장조도보다 전반적으로 낮게 유지되고 있음을 알 수 있었고, 산도는 대체로 일정하게 유지되었다. 수확량은 전체적으로 일정하지 않았고, 포기재배의 경우가 상대적으로 등외품이 적었으며, 증수 효과도 있었다. 전력소비량은 계절별로 일정한 경향이 있음을 알 수 있었고, 하절기보다 동절기에 전력소비량이 현저히 많은 것을 확인 할 수 있었다.