• Title/Summary/Keyword: horseradish

Search Result 179, Processing Time 0.023 seconds

Electrochemical Properties of Biosensor with Butyl Rubber Binder (부틸고무를 결합재로 사용한 바이오센서의 전기화학적 성질)

  • Choi, Sei-Young;Yoon, Kil-Joong
    • Elastomers and Composites
    • /
    • v.41 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • An enzyme electrode bound by butyl rubber was newly constructed for the determination of hydrogen peroxide and for the practical application as a biosensor. Then its electrochemical properties were investigated. It produced a hundreds-fold increased signal compared to the plant or animal tissue based biosensor studied previously and could be run at between $0.0{\sim}-1.00\;V$(vs. Ag/AgCl). The relationship between signal and electrode potential was linear in the experimental range of potential. It showed a detection limit of $3.0{\times}10^{-4}\;M$ and a very good linearity of Lineweaver-Burk plot giving the proof of a good enzyme immobilization. Especially, both the reproducibility of signal current due to its high sensitivity and mechanical stability presented a new possibility for the practical use of biosensor bound with butyl rubber.

Effect of Unfermented and Fermented Atractylodes macrocephalae on Gut Permeability and Lipopolysaccharide-Induced Inflammation (백출 및 발효백출의 장점막 투과성 개선 효과 및 항염증효과)

  • Han, Kyungsun;Kim, Kicheol;Wang, Jinghua;Kim, Hojun
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.13 no.1
    • /
    • pp.24-32
    • /
    • 2013
  • Objectives: The aim of this study is to investigate anti-imflammatory and protective effect for intestinal epithelial cells with Atractylodes macrocephae (AM), a traditional Korean Herbal medicine and fermented Atractylodes macrocephae (FAM) with Lactobacillus plantarum. Methods: HCT-116 and Raw 264.7 cells were used in this study. Using NO assay, we measured lipopolysaccharide (LPS)-induced anti-inflammatory effect. We measured permeability of intestinal epithelial cells with transepithelial electrical resistance and horseradish peroxide flux assay. Water soluble tetrazolium salt assay was used to see cell proliferation. All the results were presented in mean and standard deviation. We used Student's t-test for analyzing significance of results. Results: In Raw 264.7 cells NO production decreased 22.4% with pre-treatment of AM and FAM, especially with FAM in high concentration. In HCT-116 cells LPS-induced intestinal permeability had a protective effect with both AM and FAM, which was also tend to be proportional to the concentration. Cell viability increased up to 135.52% after treatment of high concentration of FAM in HCT-116, while there was no significant change in Raw 264.7 cells with herb treatments. Conclusions: These results show evidence that AM, especially fermented ones, significantly reduced intestinal membrane permeability. They also had a protective effect as well as an anti-inflammation effect for HCT-116 and Raw 264.7 cells. This suggest that FAM may be a therapeutic agent for Leaky gut syndrome by reducing intestinal permeability.

Non-Invasive Colorimetric Magneto Loop-Mediated Isothermal Amplification (CM-LAMP) Method for Helicobacter pylori Detection

  • Bangpanwimon, Khotchawan;Mittraparp-arthorn, Pimonsri;Srinitiwarawong, Kanchana;Tansila, Natta
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.501-509
    • /
    • 2021
  • More than half the world's population is thought to be infected with Helicobacter pylori. Although the majority of infected people are asymptomatic, H. pylori infection may cause gastric ulcers and deadly gastric cancer. Owing to the difficulty and invasiveness of current routine culture and diagnostic methods, a highly sensitive and specific noninvasive assay for H. pylori is of interest. This study highlighted the design and performance of a colorimetric magneto loop-mediated isothermal amplification (CM-LAMP) assay to detect H. pylori in spiked saliva samples. LF primers were coated on magnetic nanoparticles by carbodiimide-induced immobilization and functionally used for solid-phase amplification. During the LAMP reaction at 66℃, biotin-tagged FIPs were incorporated into LAMP amplicons. The colorimetric signal developed after the addition of NeutrAvidin horseradish peroxidase conjugate (NA-HRP) and ABTS. None of the tested microorganisms, including closely related bacteria, was shown positive by the CM-LAMP assay except H. pylori isolates. This novel platform was highly specific and 100-fold more sensitive (40 CFU/ml or 0.2 CFU per reaction) than the PCR and conventional LAMP assays for the detection of H. pylori in spiked saliva. Our results demonstrated the feasibility of using this noninvasive molecular diagnostic test to detect H. pylori in saliva samples.

Development and Optimization of a Rapid Colorimetric Membrane Immunoassay for Porphyromonas gingivalis

  • Lee, Jiyon;Choi, Myoung-Kwon;Kim, Jinju;Chun, SeChul;Kim, Hong-Gyum;Lee, HoSung;Kim, JinSoo;Lee, Dongwook;Han, Seung-Hyun;Yoon, Do-Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.5
    • /
    • pp.705-709
    • /
    • 2021
  • Porphyromonas gingivalis (P. gingivalis) is a major bacterial pathogen that causes periodontitis, a chronic inflammatory disease of tissues around the teeth. Periodontitis is known to be related to other diseases, such as oral cancer, Alzheimer's disease, and rheumatism. Thus, a precise and sensitive test to detect P. gingivalis is necessary for the early diagnosis of periodontitis. The objective of this study was to optimize a rapid visual detection system for P. gingivalis. First, we performed a visual membrane immunoassay using 3,3',5,5'-tetramethylbenzidine (TMB; blue) and coating and detection antibodies that could bind to the host laboratory strain, ATCC 33277. Antibodies against the P. gingivalis surface adhesion molecules RgpB (arginine proteinase) and Kgp (lysine proteinase) were determined to be the most specific coating and detection antibodies, respectively. Using these two selected antibodies, the streptavidin-horseradish peroxidase (HRP) reaction was performed using a nitrocellulose membrane and visualized with a detection range of 103-105 bacterial cells/ml following incubation for 15 min. These selected conditions were applied to test other oral bacteria, and the results showed that P. gingivalis could be detected without cross-reactivity to other bacteria, including Streptococcus mutans and Escherichia fergusonii. Furthermore, three clinical strains of P. gingivalis, KCOM 2880, KCOM 2803, and KCOM 3190, were also recognized using this optimized enzyme immunoassay (EIA) system. To conclude, we established optimized conditions for P. gingivalis detection with specificity, accuracy, and sensitivity. These results could be utilized to manufacture economical and rapid detection kits for P. gingivalis.

Highly sensitive and selective enzymatic detection for hydrogen peroxide using a non-destructively assembled single-walled carbon nanotube film (탄소나노튜브 대면적 어셈블리를 통한 고감도-고선택성 과산화수소 센서 개발)

  • Lee, Dongwook;Ahn, Heeho;Seo, Byeong-Gwuan;Lee, Seung-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.229-235
    • /
    • 2021
  • This study presents a simple approach for the assembly of a free-standing conductive electronic nanofilm of single-walled carbon nanotubes (SWNTs) suitable for enzymatic electrochemical biosensors. A large-scale SWNT electronic film was successfully produced by the dialysis of p-Terphenyl-4,4''-dithiol (TPDT)-treated SWNTs. Furthermore, Horseradish peroxidase (HRP) was immobilized on the TPDT-SWNT electronic film, and the enzymatic detection of hydrogen peroxide (H2O2) was demonstrated without mediators. The detection of H2O2 in the negative potential range (-0.4 V vs. Ag/AgCl) was achieved by direct electron transfer of heme-based enzymes that were immobilized on the TPDT-SWNT electronic film. The SWNT-based biosensor exhibited a wide detection range of H2O2 from 10 µM to 10 mM. The HRP-doped SWNT electronic film achieved a high sensitivity of 342 ㎛A/mM·cm2 and excellent selectivity against a variety of redox-active interfering substances, such as ascorbic acid, uric acid, and acetaminophen.

Selective tyrosine conjugation with a newly synthesized PCB -TE2A-luminol bifunctional chelator

  • Subramani Rajkumar;Hyun Park;Abhinav Bhise;Seong Hwan Cho;Jung Young Kim;Kyo Chul Lee;Jeongsoo Yoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.85-91
    • /
    • 2021
  • Selective amino acid conjugation of bulky antibodies is a valuable asset for real-time diagnosis and therapy. However, selective conjugation incorporating a chelate-bearing radioactive atom into an antibody without affecting its immunoreactivity is a challenging task. A bifunctional chelator (BFC), a selective amino acid-targeting probe, and a linker have been developed to overcome this problem. Here, we report the synthesis of a novel propylene cross-bridged chelator (PCB)-1,8-N,N'-bis-(carboxymethyl)-1,4,8,11-tetraazacyclotetradecane (TE2A)-luminol BFC via a click reaction and radiolabel it with a 64Cu ion for tyrosine-selective conjugation of trastuzumab. In the initial optimization study, we tried different oxidative addition conditions such as electro-oxidation, hemin, horseradish peroxidase, iodogen tube, chloramine-T, and iodo beads. In this study, up to 82% of 64Cu-PCB-TE2A-luminol was conjugated with the antibody in an iodo bead-catalyzed oxidative addition reaction with an isolated yield of 24.4%.

Development of a blocking ELISA for detection of Japanese encephalitis virus antibodies in pig and horse sera

  • Dong-Kun Yang;Eun-Ju Kim;Sang Ho Jang;Hye Jung Lee;Bitna Kim;Jin A Lee;Ju-Yeon Lee;Yun Sang Cho
    • Korean Journal of Veterinary Research
    • /
    • v.64 no.3
    • /
    • pp.26.1-26.9
    • /
    • 2024
  • Japanese encephalitis virus (JEV) is a mosquito-borne virus that can infect pigs, horses, and other mammals, including humans. Sero-epidemiological investigations of JEV have been performed using hemagglutination inhibition (HI), virus neutralization (VN) tests and enzyme-linked immunosorbent assay (ELISA). A need exists for a new ELISA that can detect JEV antibodies in the sera of several animal species. We aimed to develop a blocking ELISA (B-ELISA) for detecting JEV antibodies in pig and horse serum samples. JEV antibodies in 218 pig and 315 horse serum samples were measured using HI and VN tests. The purified KV1899-306 strain was used as an antigen for B-ELISA. The purified antibody (7A13) was conjugated with horseradish peroxidase and used as a detector antibody. The sera of pigs and horses to measure antibody against JEV were subjected to B-ELISA and analyzed. The B-ELISA had a diagnostic sensitivity of 94.6% to 100%, a specificity of 91.2 to 100%, and an accuracy of 94.9 to 98.6% compared with those of the HI and VN tests in pig and horse sera. The B-ELISA had a higher correlation with pig sera (r = 0.89 and 0.90 for VN and HI) than with horse sera (r = 0.75 and to 0.79). The new B-ELISA could be useful in the sero-surveillance of JEV in pig and horse sera and replace indirect ELISA.

Ultrasensitive Enzymeimmunoassay for Testosterone in Human Saliva (사람 타액내 Testosterone의 초감도 효소면역측정법)

  • 윤용달;전은현;이창주;도병록;이준영
    • Development and Reproduction
    • /
    • v.4 no.1
    • /
    • pp.115-123
    • /
    • 2000
  • A few enzymeimmunoassay (EfA) for testosterone (T) have been reported but was not suitable for all biological samples. The present study was designed to develop a rapid, ultrasensitive EIA and to apply this technique for study the physiological changes of T in biological samples. Saliva samples were collected at 06:00~09:00 hour during one menstrual cycle from 18 normally menstruating women and on 09:00~10:00 hour from 20 normal men. The present study shows an established EIA for testosterone, using horseradish peroxidase (HRP), which was covalently bonded to testosterone-3-carboxymethyloxime (T-3-CMO). One batch of T-antisera was also covalently linked to microcrystalline cellulose particles by a mixed anhydride method in order to facilitate separation of bound and free steroids. The established EIA was validated in terms of sensitivity, accuracy, specificity, precisions etc., comparing with conventional radioimmunoassay. The sensitivity of the established EIA was less than 25 pg/tube. The correlation coefficients between the expected T-values and observed T-values measured by EIA or RIA were r=0.985 and r=0.941 respectively. The cross reactivity of antiserum in EIA was a little higher than that of RIA, especially by 5 ${\alpha}$-DHT. The intra- and inter-assay precisions of the present EIA were similar to those of RIA. The present study also demonstrates that the normal T-values in saliva of Korean male & female samples are 265.65${\pm}$15.80 pmol/l and 109.74${\pm}$ 12.01 pmol/l, respectively. The present EIA seems to be established and suitable for use in the endocrinological studies. The advantages of this EIA system also might make the present T-EIA an ideal procedure for use in a routine assay of ordinary laboratory with a conventional spectrophotometer.

  • PDF

Immunohistochemical Analysis for the Expression of DR5 TRAIL Receptor and p53 in Non-small Cell Lung Cancer (비소세포폐암에서 DR5 TRAIL 수용체와 p53에 관한 면역조직화학적 분석)

  • Lee, Kye-Young;Lee, Jung-Hyun;Kim, Sun-Jong;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.4
    • /
    • pp.278-284
    • /
    • 2008
  • Background: TRAIL is a promising anticancer agent which induces selective tumor cell death due to a unique receptor system that includes death receptors and decoy receptors. DR5 TRAIL receptor is an originally identified p53-regulated death receptor gene that was induced, by doxorubicine, only in cells with a wild-type p53 status. We investigated that focused on the correlation between the DR5 and p53 expressions in non-small cell lung cancer (NSCLC). Methods: Immunohistochemical analysis, with using avidin-biotinylated horseradish peroxidase complex, was carried out in 89 surgically resected NSCLC formalin-fixed paraffin-embedded tissue sections. As primary antibodies, we used anti-DR5 polyclonal antibody and anti-p53 monoclonal antibody. A negative control was processed with each slide. The positive tumor cells were quantified twice and these values were expressed as percentage of the total number of tumor cells, and the intensity of immunostaining was expressed. The analysis of the DR5 expression was done separately in tumor area and in a nearby region of normal tissue. Results: The DR5 expression was high in the bronchial epithelium (89% of cases) but this was almost absent in type I & II pneumocytes, lymphocytes and smooth muscle cells. High DR5 expression rate in tumor was seen in 28% (15/53) of squamous cell carcinomas, in 47% (15/32) of adenocarcinomas and, in 50% (2/4) of large cell carcinomas. The DR5 expression did not show any statistical significance relationship with the T stage, N stage, or survival. However, the DR5 expression showed significant inverse correlation with the p53 expression. (p< 0.01). Conclusion: We demonstrated that the DR5 expression in NSCLC via immunohistochemical analysis is relatively tumor-specific except for that in the normal bronchial epithelium and it is significantly dependent on the p53 status. This might be in vivo evidence for the significance of the DR5 gene as a p53 downstream gene.

Retrograde Tracer Studies of Tecto-Reticulospinal Pathway and Dorsal Lateral Geniculate Nucleus on GluR1- and GluR4-Immunoreactive Neurons in the Hamster Superior Colliculus (Tecto-reticulospinal pathway (TRS)와 dorsal lateral geniculate nucleus (dLGN)에서 역행성이동추적물질 이용 햄스터 상구에서 GluR1-, GluR4- 면역반응 신경세포 연구)

  • Choi, Jae-Sik;Lee, Jea-Young;Jang, Yu-Jin;Lee, Eun-Shil;Jeon, Chang-Jin
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • We recently reported the distributions of AMPA ($\alpha$-amino-3-hydroxyl-5-methyl-4-isoxazole-propionate) receptor subtypes glutamate receptors (GluR) 1 and GluR4 in the superior colliculi (SC) of hamsters with antibody immunocytochemistry and the effect of enucleation on these distributions. We also compared these labelings to those of calcium-binding proteins calbindin D28K, calretinin, parvalbumin, and GABA. In the present study, we investigated whether the GluR1- and GluR4-immunoreactive (IR) neurons are interneurons or projection neurons by injection of the retrograde tracer horseradish peroxidase (HRP) into one of each major ascending and descending pathways of the SC. HRP injections were made into a tecto-reticulospinal pathway (TRS) and dorsal lateral geniculate nucleus (dLGN). Animals were then allowed to recover and to survive for 48 hr before perfusion. Sections containing retrograde-labeled neurons were then treated for GluR-immunoreactivity. HRP injections proved that only a small population of the GluR1-IR cells project into TRS (1.4%) and dLGN (2.6%). However, a large subpopulation of GluR4-IR cells project into TRS (32.7%). The differential compositions of inter/projection neurons, along with our previous studies on the separate distribution of the GluR subunits, its differential co-localization with calcium-binding proteins and GABA, and differential reactions to enucleations, strongly imply the functional variety of the receptor subunits in visual behavior responses.