• Title/Summary/Keyword: horizontal-vertical projection

Search Result 84, Processing Time 0.026 seconds

Recognition of Raised Characters for Automatic Classification of Rubber Tires (고무타이어 자동분류를 위한 돌출문자 인식)

  • 함영국;강민석;정홍규;박래홍;박귀태
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.4
    • /
    • pp.77-87
    • /
    • 1994
  • This paper presents recognition of raised alphanumeric markings on rubber tires for their automatic classification. Raised alphanumeric markings on rubber tires have different characteristics as compared to those of printed characters. In the preprocessing step, we first determine the rotation angle using the Hough transform and align markings, then separate each character using vertical and horizontal projections. In the recognition step, we use several features such as width of a character, cross point, partial projection, and distance feature to recognize characters hierarchically. The computer simulation result shows that the proposed system can be successfully applied to the industrial automation of rubber tires classification.

  • PDF

Automatic Extraction of Component Inspection Regions from Printed Circuit Board by Image Clustering (영상 클러스터링에 의한 인쇄회로기판의 부품검사영역 자동추출)

  • Kim, Jun-Oh;Park, Tae-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.472-478
    • /
    • 2012
  • The inspection machine in PCB (printed circuit board) assembly line checks assembly errors by inspecting the images inside of the component inspection region. The component inspection region consists of region of component package and region of soldering. It is necessary to extract the regions automatically for auto-teaching system of the inspection machine. We propose an image segmentation method to extract the component inspection regions automatically from images of PCB. The acquired image is transformed to HSI color model, and then segmented by several regions by clustering method. We develop a modified K-means algorithm to increase the accuracy of extraction. The heuristics generating the initial clusters and merging the final clusters are newly proposed. The vertical and horizontal projection is also developed to distinguish the region of component package and region of soldering. The experimental results are presented to verify the usefulness of the proposed method.

Wide Field-of-View Imaging Using a Combined Hyperbolic Mirror

  • Yi, Sooyeong;Ko, Youngjun
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.336-343
    • /
    • 2017
  • A wide field-of-view (FOV) image contains more visual information than a conventional image. This study proposes a new type of hyperbolic mirror for wide FOV image acquisition. The proposed mirror consists of a hyperbolic cylindrical section and a bowl-shaped hyperbolic omnidirectional section. Using an imaging system with this mirror, it is possible to achieve a $213.8^{\circ}$ horizontal and a $126.94^{\circ}$ vertical maximum FOV. Parameters of each section of the mirror are designed to be continuous at the junction of the two parts, and the resultant image is seamless. The image-acquisition model is obtained using ray-tracing optics. To rectify the geometrical distortion of the original image due to the mirror, an image-restoration algorithm based on conformal projection is presented in this study. The performance of the proposed imaging system with the hyperbolic mirror and its image-restoration algorithm are verified by experiments.

Development of Three Dimensional Scanner for Anthropometric Measurement (인체측정용 3차원 스캐너 제작)

  • Kim, Min-Hyo;Nam, Yun-Ja
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.77-88
    • /
    • 2001
  • A three dimensional body scanner for anthropomentric measurement has been developed. In this study, the slit laser beam projection method followed by digital image processing was used to provide accurate spatial data with the typical optical triangulation method to overcome the many difficulties in traditional in accurate and time-consuming tactic measurement method using rulers and gauges. Compared with other commercialized scanners. this system can obtain a relatively wide range of data at a much lower cost by the specially designed scanning process such as the simultaneous acquisition of vertical and horizontal body cross-section profiles.

  • PDF

THE STUDIES ON STANDARDIZED PROJECTION FOR TEMPOROMANDIBULAR JOINT (악관절의 규격화 촬영에 관한 연구)

  • Park Tae Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.12 no.1
    • /
    • pp.63-67
    • /
    • 1982
  • The author modified the Aquard 100 head holder device from Denar Co. to be adequate to the Koreans and to enhance the standardization and reproducibility of the temporomandibular joint radiographs. The results were obtained as follows; 1. The projected central ray was at an angle of 25 degrees. 2. Standardization of patients head position was obtained by means of vertical and horizontal bar which were attached to the head holder. 3. Arbitrary 3 points (A.B.C.) which were on the TMJ area of dry skull were measured for the identification of reproducibility. 4. Measured distances in dry skull were as follow; A-B, 28.0±0.25, B-C 11.9±0.25 and C-A 30.4±0.21, in closed position.

  • PDF

Approximate calculation of the static analysis of a lifted stay cable in super-long span cable-stayed bridges

  • Zhao, Xinwei;Xiao, Rucheng;Sun, Bin
    • Structural Engineering and Mechanics
    • /
    • v.74 no.5
    • /
    • pp.635-655
    • /
    • 2020
  • The sag effect of long stay cables is one of the key factors restricting further increase in the span of cable-stayed bridges. Based on the formerly proposed concept of long stay cables lifted by an auxiliary suspension cable in cross-strait cable-stayed bridges, corresponding static approximate calculations and analytical theory based on catenary and parabolic cable configurations are established. Taking a main span 1400 m cable-stayed bridge as the research object, three typical lifting conditions and the whole process of auxiliary cable lifting are analyzed and discussed. The results show that the sag effect is effectively reduced. The support efficiency is only improved when the cables are lifted above the original cable chord. Reduction of the horizontal component force of the cable is limited. The equivalent elastic modulus and the vertical support stiffness of the lifted cables are significantly increased with increased horizontal projection length and not sensitive to the change of the lifting point position. The scheme of lifting the cable to the chord midpoint is more economical because of the less steel required for the auxiliary suspension cable, but its effect on improving the vertical support efficiency is limited. The support efficiency is better when the cable is lifted to the cable end tangential to the original cable chord, but the lifting force and the cross-sectional area of the auxiliary suspension cable are doubled. The approximate calculation results of the lifted cables are very close to the numerical analysis results, which verifies the applicability of the approximation method proposed in this study. The results of parabolic approximation calculations are approximately equal to that of catenary cable geometry. As the parabolic approximation analysis theory of lifted cables is more convenient in mathematical processing, it is feasible to use parabolic approximation analysis theory as the analytical method for the conceptual design of lifted cables of super-long span cable-stayed bridges.

Relationship between Joint Space and Craniofacial Morphology in Patients with Craniomandibular Disorders (두개하악장애환자에서 악관절강폭과 측모두부형태와의 관계에 관한 연구)

  • Myung-Seok Seo;Kyung-Soo Han;Min Shin
    • Journal of Oral Medicine and Pain
    • /
    • v.17 no.2
    • /
    • pp.63-73
    • /
    • 1992
  • This study was performed for the purpose of investigating the relation between width of temporomandibular joint space and craniofacial morphology in patients with CMDs. The subjects utilized here were aged from 16 to 63 years old and 19 male and 46 female. For the study, each patient was taken radiographs by Transcranial and Lateral Cephalographic projection and the films were traced with routine method. The measured items were anterior, superior, posterior joint space and relative condylar position to the deepest part of glenoid fossa in Transcranial film and items related vertical and/or horizontal growth in Cephalogram. The data were processed with SPSS/PC+ package for statistical analysis. The obtained results were as follows : 1. Anterior joint space in affected side were wider than that of unaffected side, but for superior and posterior joint space, the value of unaffected side were more than those of affected side. 2. Superior or posterior joint space of affected side were significantly correlated with items related vertical growth, such as ramus height, Jarabak ratio, FMA. From this, the following cold be proposed, the wider the joint space of superior or posterior aspect of affected side was, the more the patient showed growth pattern of counter clockwise. 3. Superior or posterior joint space of affected side were significantly correlated with items related horizontal growth, such as SNPo, NAPo, APDI and ANB. From this the following could be proposed, the wider the joint space of superior or posterior aspect of affected side was, the more the patient showed anterior displacement of mandible. 4. It would be proposed that the diagnositic value of superior and posterior joint space of affected side in transcranial radiograph was excellent.

  • PDF

CHANGE OF LATERAL SOFT TISSUE PROFILE AFTER SURGICAL CORRECTION OF MANDIBULAR PROGNATHISM (하악전돌증의 악교정수술후 연조직 변화에 관한 연구)

  • Lee, Sang-Chull;Kim, Yeo-Gab;Ryu, Dong-Mok;Lee, Wan-Kee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.3
    • /
    • pp.217-227
    • /
    • 1992
  • The purpose of this paper is to investigate changes in soft tissue in 22 patients treated by vertical ramus osteotomy and sagittal split ramus osteotomy for the correction of mandibular prognathism. 22 individuals, 12 males and 10 females, were selected from the patients with mandibular prognathism at the Department of Oral and Maxillofacial Surgery, Colledge of Dentistry, Kyung Hee University. Patient were analyzed with cephalogram taken 1 week before and at least 6 weeks after surgery under the same condition. Measurements were made constructed hard tissue and sop tissue points located on each before-and-after film tracing. Comparision were made of these figures to estimate the amount that the soft tissue followed the hard tissue structures in each surgical procedure : ratio of sop and hard tissue changes were formulated. The results were as follows. 1. The horizontal changes of Pogs and Bs as a ratio of the horizontal changes of Pog and B point were 1.02 and 1.16 respectively. 2. One millimeter of posterior changes at Pog resulted in 0.86mm of posterior change at Li and 0.09mm of posterior change at Ls. The greatest amount of sop tissue change occurred at Pogs, with substantially less posterior displacement at Bs, even less at Li and at least at Ls. 3. The ratio of LI to Li was 1:0.81 and the ratio of LI to Ls was not significant.(1 : 0.17) 4. The ULA(Cm-Sn-Ls) and the relative lower lip projection (LLP) was incnease4 but the relative upper lip projection (ULP) was slightly decreased 5. The angular change of the upper lip inclined angle (Ls-Sn/ANS-PNS) and lower lip inclined angle(Li-Pogs/Me-Go) expressed as a ratio of the posterior change of Pog were 0.57 and 0.20 respectively. 6. The ratio of the lower anterior facial height change of the soft tissue(Sn-Mes) to the hard tissue(ANS-Gn) were 0.78 and and the ratio of vertical height changes of the hard tissue and sop tissue to the posterior change of the Pog were 0.18 and 0.19 respectively. 7. The sop tissue angular change of facial convexity(G-Sn-Pogs) expressed as a ratio of the angular change of the hard tissue angle of facial convexity(N-A-Pog) was 1.24.

  • PDF

The Study of Effectiveness of 3 Spot DR for the Whole Spine Radiography with Comparison of Phantom Distortions (3 Spot DR를 이용한 척추 전장 촬영 시 모형 왜곡도 비교를 통한 유용성 연구)

  • Kim, Sang-Hyun;Lee, Mi-Hwa
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.345-351
    • /
    • 2014
  • The purpose of this study is to offer more accurate information in whole spine examination of 3 spot DR through the comparative study about image distortion as making the flat phantom and measuring horizontal, vertical ratio and cobb angle of the virtual. We produced $H(40cm){\times}V(116cm){\times}D(2.3cm)$ flat acrylic phantom with lattice type of lead plate. We took projection respectively 3 times, total 9 times in each equipments using manufactured phantom as changing OFD to 6, 12, 18 cm. We measured a horizontal and vertical length of lead lattice and calculated the ratio. As appointing arbitrary points in the phantom and we measured cobb angle. The results of horizontal, vertical ratio measured CR type 0.98~1.01, scan DR type 0.96~0.97 and 3 spot DR 0.99~1.01. Cobb angle measured $52.5{\sim}53.3^{\circ}$, $52.1{\sim}54.3^{\circ}$ and $52.8{\sim}53.2^{\circ}$. Finally we can say that 3 spot DR method is an accurate method without any distortion in whole spine radiography.

Web-based Moving Object Tracking by Controlling Pan-Tilt Camera using Motion Detection (움직임 검출의 캠 제어에 의한 웹기반 이동 객체 추적)

  • 박천주;박희정;이재협;전병민
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.2
    • /
    • pp.17-26
    • /
    • 2002
  • In this paper, we suggest a method to acquire the moving object centered video by panning and tilting a camera automatically according to motion vectors calculated by detecting the motion of a moving object on video steam. We create a difference image by estimating the intensity difference at the grid points of neighboring frames. And we detect the motion using both horizontal projection histogram and vertical projection histogram and decide the center of motion part. Then we calculate a new direction and degree of the motion by comparing coordinates at the center of current motion and the center of previous motion. By controling the RCM using these Motion vectors, we can get video stream positioned unwire object on the center of video frame. Through the experiments, we could get a moving object centered video stream continuously arid monitor remotely by implementing sever/client architecture based on the web.

  • PDF