• 제목/요약/키워드: horizontal shear resistance

검색결과 67건 처리시간 0.03초

철근콘크리트 깊은 보에서 수평 전단철근의 전단저항에 관한 실험적 연구 (An Experimental Study on the Shear Resistance of Horizontal Shear Reinforcement in R.C. Deep Beams)

  • 양근혁;이영호;은희창;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.903-906
    • /
    • 2001
  • The objective of this experimental study was to understand the effect of horizontal shear bar on the shear behavior of R.C. deep beams. Therefore, in the test program, the horizontal shear bar ratio($\rho_{sh}$) and shear span-to-overall depth ratio(a/h) are considered as two main variables. Test results indicate that for deep beams with a/h equal to 1.0, horizontal shear bar is less efficient in restricting the diagonal crack width development and enhancing the ultimate shear strength. So, it can be concluded that shear resistance of horizontal shear bar is related to a/h rather than clear span-to-effective depth ratio($l_{n}$/d) recommended in ACI code.

  • PDF

대형판 프리캐스트 콘크리트 구조 수평접합부의 전단내력에 대한 실험적 연구 (An Experimental Study on the Shear Resistance of Horizontal Joints in Precast Concrete Large Panel Structures)

  • 정창용;현원창;엄철환;어양석;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.208-213
    • /
    • 1992
  • This research is related to the experimental verification of the shear resistance of horizontal joint in precast concrete large panel structures. a total of 9 spicemens was tested to assess their shear resistance. In the tests lateral forces have been applied to the specimen to cause shear failure while keeping the axial compression consistantly. The shear resistances of the specimens have been evaluated by investigating the deformations and failure modes of the specimens. From the test results, it is observed that the shear resistance of the horizontal joints of P.C panel structures are closely connected with shear friction mechanism.

  • PDF

전단 지간의 변화에 따른 PSC 거더용 강-콘크리트 합성 바닥판의 역학적 거동 (Behavior of Steel-Concrete Composite Decks for PSC Girder Bridge with Various Shear Span Lengths)

  • 김태협;박준명;홍성남;박선규;김형렬
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.275-281
    • /
    • 2007
  • 최근에 교량과 건축물의 건설에 강-콘크리트 합성 구조물이 광범위하게 적용되고 있다. 본 논문에서는 과거의 현장 타설 철근콘크리트 바닥판을 대체하기 위하여 새로운 형태의 강-콘크리트 합성 바닥판을 재안하였다. 유공판재형 전단 연결재는 성형 강판과 콘크리트 사이의 수평전단저항력을 제공하는데 유용하였다. 제안된 바닥판 시스템의 효과를 증명하기 위하여 PSC 거더용 바닥판을 8개 제작하였으며, 정적 하중 상태에서 바닥판의 수평전단저항력을 결정하기 위하여 4가지의 전단 지간을 적용하여 실험을 수행하였다. 또한 제안된 바닥판과의 비교를 위하여 2개의 철근콘크리트 바닥판을 제작하여 실험을 수행하였다. 그리고 제안된 바닥판 시스템의 수평전단저항력은 m-k 방법을 이용하여 산정되었다.

철근콘크리트 깊은 보에서 전단철근비와 전단내력의 관계 (The Relationships Between Shear Reinforcement Ratios and Shear Strength in Reinforced Concrete Deep Beams)

  • 양근혁;박정화;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.256-259
    • /
    • 2004
  • The objective of this experimental study is to understand the effects of horizontal and vertical shear reinforcement on the shear strength of concrete deep beams. Main variables were the horizontal shear reinforcement ratio $(P_{sh})$, vertical shear reinforcement ratio$(P_{sv})$ and shear span-to-overall depth ratio(a/h). Test results revealed that the effectiveness of shear resistance of shear reinforcement was greatly related to the a/h. For the beams with $a/h\geq1.0$, the vertical shear reinforcement was more effective than horizontal shear reinforcement.

  • PDF

Effect of Glass Fiber-Reinforced Connection on the Horizontal Shear Strength of CLT Walls

  • JUNG, Hongju;SONG, Yojin;HONG, Soonil
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권5호
    • /
    • pp.685-695
    • /
    • 2020
  • The connection performance between cross-laminated timber (CLT) walls and support has the greatest effect on the horizontal shear strength. In this study, the horizontal shear performance of CLT walls with reinforced connection systems was evaluated. The reinforcements of metal bracket connections in the CLT connection system was made by attaching glass fiber-based reinforcement to the connection zone of a CLT core lamina. Three types of glass fiber-based reinforcement were used: glass fiber sheet (GS), glass fiber cloth (GT) and fiber cloth plastic (GTS). The horizontal shear strength of the fabricated wall specimens was compared and evaluated through monotonic and cyclic tests. The test results showed that the resistance performance of the reinforced CLT walls to a horizontal load based on a monotonic test did not improve significantly. The residual and yield strengths under the cyclic loading test were 38 and 18% higher, respectively, while the ductility ratio was 38% higher than that of the unreinforced CLT wall. The glass fiber-based reinforcement of the CLT connection showed the possibility of improving the horizontal shear strength performance under a cyclic load, and presented the research direction for the application of real-scale CLT walls.

아스팔트콘크리트 궤도용 궤도변위 저항 장치 개발 (Development of Device to Resist Horizontal Displacement of Asphalt Concrete Track)

  • 이성혁;윤우용;배영훈
    • 한국철도학회논문집
    • /
    • 제19권6호
    • /
    • pp.744-754
    • /
    • 2016
  • 아스팔트콘크리트 궤도는 아스팔트콘크리트 도상 위에 광폭침목 및 콘크리트 패널이 직결되는 궤도 형식으로서 각종 종 횡방향 외력에 대한 저항력이 요구된다. 따라서 본 논문에서는 광폭침목형 및 콘크리트 패널형 아스팔트콘크리트 궤도에 대해 종 횡방향 저항력 실험을 수행하고 궤도변위 저항 장치에 요구되는 필요 전단 저항력을 산정하였다. 또한 궤도변위 저항 장치로서 콘크리트 블록형 앵커 및 강관형 앵커를 개발하고 각각의 앵커 실험체에 대한 수평전단 실험을 수행하여 앵커 종류별 전단 저항력을 도출하였다. 그리고 아스팔트콘크리트 궤도에 궤도변위 저항 장치 적용 시, 전단 저항 성능 및 경제성 등을 고려하여 궤도변위 저항 장치 적정 개수 및 배치 설계(안)을 제시하였다.

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

Shear resistance behaviors of a newly puzzle shape of crestbond rib shear connector: An experimental study

  • Chu, Thi Hai Vinh;Bui, Duc Vinh;Le, Van Phuoc Nhan;Kim, In-Tae;Ahn, Jin-Hee;Dao, Duy Kien
    • Steel and Composite Structures
    • /
    • 제21권5호
    • /
    • pp.1157-1182
    • /
    • 2016
  • A newly puzzle shape of crestbond rib shear connector is a type of ductile perfobond rib shear connector. This shear connector has some advantages, including relatively easy rebar installation and cutting, as well as the higher shear resistance strength. Thus, this study proposed a newly puzzle shape of crestbond rib with a "${\mho}$" shape, and its shear resistance behaviors and shear strengths were examined using push-out tests. Five main parameters were considered in the push-out specimens to evaluate the effects of shear resistance parameters such as the dimensions of the crestbond rib, transverse rebars in the crestbond dowel, concrete strength, rebar strength, and dowel action on the shear strength. The shear loading test results were used to compare the changes in the shear behaviors, failure modes, and shear strengths. It was found that the concrete strength and number of transverse rebars in the crestbond rib were significantly related to its shear resistance. After the initial bearing resistance behavior of the concrete dowel, a relative slip occurred in all the specimens. However, its rigid behavior to shear loading decreased the ductility of the shear connection. The cross-sectional area of the crestbond rib was also shown to have a minor effect on the shear resistance of the crestbond rib shear connector. The failure mechanism of the crestbond rib shear connector was complex, and included compression, shear, and tension. As a failure mode, a crack was initiated in the middle of the concrete slab in a vertical direction, and propagated with increasing shear load. Then, horizontal cracks occurred and propagated to the front and rear faces of the specimens. Based on the results of this study, a design shear strength equation was proposed and compared with previously suggested equations.

Horizontal stiffness solutions for unbonded fiber reinforced elastomeric bearings

  • Toopchi-Nezhad, H.
    • Structural Engineering and Mechanics
    • /
    • 제49권3호
    • /
    • pp.395-410
    • /
    • 2014
  • Fiber Reinforced Elastomeric Bearings (FREBs) are a relatively new type of laminated bearings that can be used as seismic/vibration isolators or bridge bearings. In an unbonded (U)-FREB, the bearing is placed between the top and bottom supports with no bonding or fastening provided at its contact surfaces. Under shear loads the top and bottom faces of a U-FREB roll off the contact supports and the bearing exhibits rollover deformation. As a result of rollover deformation, the horizontal response characteristics of U-FREBs are significantly different than conventional elastomeric bearings that are employed in bonded application. Current literature lacks an efficient analytical horizontal stiffness solution for this type of bearings. This paper presents two simplified analytical models for horizontal stiffness evaluation of U-FREBs. Both models assume that the resistance to shear loads is only provided by an effective region of the bearing that sustains significant shear strains. The presented models are different in the way they relate this effective region to the horizontal bearing displacements. In comparison with experimental results and finite element analyses, the analytical models that are presented in this paper are found to be sufficiently accurate to be used in the preliminary design of U-FREBs.

80 MPa급 콘크리트를 활용한 이중합성 거더의 수평접합면 구조거동에 관한 실험적 연구 (Experimental Study on Structural Behavior of Interfaces of Double Composite Girder Using the 80 MPa Concrete)

  • 양인욱;임얼;하태열
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.400-413
    • /
    • 2016
  • 80 MPa급 고강도 콘크리트가 강거더의 압축 플랜지로 대체하는 아중합성 거더의 경우, 플랜지와 케이싱 및 케이싱과 바닥판 2개의 접합부 계면이 형성되는데 각 계면의 수평 전단 저항능력은 구조물의 안전성에 있어 중요한 요소이다. 본 연구는 계면 상세를 달리한 6개의 실험체를 도로교설계기준(한계상태설계법)에 따라 설계 및 제작하여 이중합성 보의 휨 파괴 대비 수평 전단에 대한 구조 성능 실험을 수행하였다. 실험체의 주요변수로 스터드 전단연결재의 저항계수, 바닥판 콘크리트 및 철근의 재료저항계수, 콘크리트 인장강도에 따른 부착계수, 케이싱 콘크리트의 표면 상태 그리고 수평전단철근의 간격을 고려하였다. 실험 결과, 강재 상부 플랜지와 고강도 케이싱의 계면이 고강도 케이싱과 바닥판 계면 보다 결합성이 큰 것으로 나타났다. 그리고 고강도 케이싱과 바닥판 계면에서는 케이싱 표면에 요철 또는 거칠기를 주는 것 보다 보수적으로 수평전단철근을 배근하는 것이 소성영역까지 합성 거동을 유지하는 것으로 나타났다.