Design and analysis of isolation effectiveness for three-dimensional base-seismic isolation of nuclear island building

  • Zhu, Xiuyun;Lin, Gao;Pan, Rong;Li, Jianbo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.374-385
    • /
    • 2022
  • In order to investigate the application of 3D base-seismic isolation system in nuclear power plants (NPPs), comprehensive analysis of constitution and design theory for 3-dimensional combined isolation bearing (3D-CIB) was presented and derived. Four different vertical stiffness of 3D-CIB was designed to isolate the nuclear island (NI) building. This paper aimed at investigating the isolation effectiveness of 3D-CIB through modal analysis and dynamic time-history analysis. Numerical results in terms of dynamic response of 3D-CIB, relative displacement response, acceleration and floor response spectra (FRS) of the superstructure were compared to validate the reliability of 3D-CIB in mitigating seismic response. The results showed that 3D-CIB can significantly attenuate the horizontal acceleration response, and a fair amount of the vertical acceleration response reduction of the upper structure was still observed. 3D-CIB plays a significant role in reducing the horizontal and vertical FRS, the vertical FRS basically do not vary with the floor height. The smaller the vertical stiffness of 3D-CIB is, the better the vertical isolation effectiveness is, whereas, it will increase the displacement and the rocking effect of superstructure. Although the advantage of 3D-CIB is that the vertical stiffness can be flexibly adjusted, it should be designed by properly accounting for the balance between the isolation effectiveness and displacement control including rocking effect. The results of this study can provide the technical basis and guidance for the application of 3D-CIB to engineering structure.

Air horizontal jets into quiescent water

  • Weichao Li ;Zhaoming Meng;Jianchuang Sun;Weihua Cai ;Yandong Hou
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2011-2017
    • /
    • 2023
  • Gas submerged jet is an outstanding thermohydraulic phenomenon in pool scrubbing of fission products during a severe nuclear accident. Experiments were performed on the hydraulic characteristics in the ranges of air mass flux 0.1-1400 kg/m2s and nozzle diameter 10-80 mm. The results showed that the dependence of inlet pressure on the mass flux follows a power law in subsonic jets and a linear law in sonic jets. The effect of nozzle submerged depth was negligible. The isolated bubbling regime, continuous bubbling regime, transition regime, and jetting regime were observed in turn, as the mass flux increased. In the bubbling regime and jetting regime, the air volume fraction distribution was approximately symmetric in space. Themelis model could capture the jet trajectory well. In the transition regime, the air volume fraction distribution loses symmetry due to the bifurcated secondary plume. The Li correlation and Themelis model showed sufficient accuracy for the prediction of jet penetration length.

Development of Fender Segmentation System for Port Structures using Vision Sensor and Deep Learning (비전센서 및 딥러닝을 이용한 항만구조물 방충설비 세분화 시스템 개발)

  • Min, Jiyoung;Yu, Byeongjun;Kim, Jonghyeok;Jeon, Haemin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.28-36
    • /
    • 2022
  • As port structures are exposed to various extreme external loads such as wind (typhoons), sea waves, or collision with ships; it is important to evaluate the structural safety periodically. To monitor the port structure, especially the rubber fender, a fender segmentation system using a vision sensor and deep learning method has been proposed in this study. For fender segmentation, a new deep learning network that improves the encoder-decoder framework with the receptive field block convolution module inspired by the eccentric function of the human visual system into the DenseNet format has been proposed. In order to train the network, various fender images such as BP, V, cell, cylindrical, and tire-types have been collected, and the images are augmented by applying four augmentation methods such as elastic distortion, horizontal flip, color jitter, and affine transforms. The proposed algorithm has been trained and verified with the collected various types of fender images, and the performance results showed that the system precisely segmented in real time with high IoU rate (84%) and F1 score (90%) in comparison with the conventional segmentation model, VGG16 with U-net. The trained network has been applied to the real images taken at one port in Republic of Korea, and found that the fenders are segmented with high accuracy even with a small dataset.

SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR+ PASSIVE AUXILIARY FEEDWATER SYSTEM

  • Kang, Kyoung-Ho;Kim, Seok;Bae, Byoung-Uhn;Cho, Yun-Je;Park, Yu-Sun;Yun, Byoung-Jo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.597-610
    • /
    • 2012
  • The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+, which is intended to completely replace the conventional active auxiliary feedwater system. With an aim of validating the cooling and operational performance of PAFS, an experimental program is in progress at KAERI, which is composed of two kinds of tests; the separate effect test and the integral effect test. The separate effect test, PASCAL ($\underline{P}$AF$\underline{S}$ $\underline{C}$ondensing Heat Removal $\underline{A}$ssessment $\underline{L}$oop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in PAFS. A single, nearly-horizontal U-tube, whose dimensions are the same as the prototypic U-tube of the APR+ PAFS, is simulated in the PASCAL test. The PASCAL experimental result showed that the present design of PAFS satisfied the heat removal requirement for cooling down the reactor core during the anticipated accident transients. The integral effect test is in progress to confirm the operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. As the first integral effect test, an FLB (feedwater line break) accident was simulated for the APR+. From the integral effect test result, it could be concluded that the APR+ has the capability of coping with the hypothetical FLB accident by adopting PAFS and proper set-points of its operation.

Dynamic characteristics of single door electrical cabinet under rocking: Source reconciliation of experimental and numerical findings

  • Jeon, Bub-Gyu;Son, Ho-Young;Eem, Seung-Hyun;Choi, In-Kil;Ju, Bu-Seog
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2387-2395
    • /
    • 2021
  • Seismic qualifications of electrical equipment, such as cabinet systems, have been emerging as the key area of nuclear power plants in Korea since the 2016 Gyeongju earthquake, including the high-frequency domain. In addition, electrical equipment was sensitive to the high-frequency ground motions during the past earthquake. Therefore, this paper presents the rocking behavior of the electrical cabinet system subjected to Reg. 1.60 and UHS. The high fidelity finite element (FE) model of the cabinet related to the shaking table test data was developed. In particular, the first two global modes of the cabinet from the experimental test were 16 Hz and 24 Hz, respectively. In addition, 30.05 Hz and 37.5 Hz were determined to be the first two local modes in the cabinet. The high fidelity FE model of the cabinet using the ABAQUS platform was extremely reconciled with shaking table tests. As a result, the dynamic properties of the cabinet were sensitive to electrical instruments, such as relays and switchboards, during the shaking table test. In addition, the amplification with respect to the vibration transfer function of the cabinet was observed on the third floor in the cabinet due to localized impact corresponding to the rocking phenomenon of the cabinet under Reg.1.60 and UHS. Overall, the rocking of the cabinet system can be caused by the low-frequency oscillations and higher peak horizontal acceleration.

Distribution of Common Squid Todarodes pacificus Larvae in the Southwestern Part of the East Sea in Summer and Autumn, 2015 (2015년 하계 및 추계 동해 남서해역에서 출현하는 살오징어 (Todarodes pacificus) 유생의 분포 양상)

  • KIM, Yoon-Ha;SHIN, Dong-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.2
    • /
    • pp.220-228
    • /
    • 2019
  • To determine the horizontal and temporal distribution of common squid larvae, Todarodes pacificus (hereafter T. pacificus), we conducted surveys using an IKMT net (mesh size: $500{\mu}m$) with a Fisheries Research Vessel (FRV, TAMGU 21) in the southwestern part of the East Sea in summer (August and September) and autumn (November) 2015. A total of 228 larvae, ranging in mantle length (ML) from 1.4 mm to 21.9 mm, were collected at 35 stations over the research period. The monthly average mantle length of T. pacificus larvae did not differ significantly in August, September and November. (p > 0.05). Catch densities at positive stations ranged between 0.1 and $7.9inds./1,000m^3$ over the research period. Incidence rates of T. pacificus larvae were similar over three months, in the study area (62.9 % - 68.6 %). The 4 - 5 mm mantle length range had the highest frequency in size-frequency distributions for T. pacificus larvae. The larval survival temperature ($15-24^{\circ}C$) at positive stations for catch densities was located below a 20 m depth in August whereas it was located at the surface of the water in September and November. The survival temperature for larvae existed from the bottom to the surface of the water where larvae were sampled larvae in shallow sea areas. However, the larval survival temperature occurred in a shallower location than the upper layer of the thermocline in deep sea areas at a depth below 100 m.

Distribution of Zooplankton by ADCP's Echo Intensity in the Coastal Water used Yellow Loess (다층 도플러 유속계(ADCP)를 이용한 황토 살포 해역의 플랑크톤 평가)

  • Park, Ju-Sam;Choo, Hyo-Sang;Moon, Sung-Ryong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.2
    • /
    • pp.141-151
    • /
    • 2010
  • Harmful algal blooms (HABs), commonly known as red tides, are aquatic phenomena caused by the rapid growth and accumulation of certain microalgae, which can lead to marked discoloration of surface waters, and severe impacts on public health, commerce, and the environment. In South Korea, the red tides have been a serious and recurrent problem, especially along the south coast. Plenty of yellow loess was used to control an outbreak of the red tides for 15 years from 1996 until now. Yellow loess was almost sprayed in the vicinity of a large fish farming industry. In this research, the distribution characteristics and density distribution of zooplankton were investigated in autumn (Oct. 2008) and spring (Apr. 2009) using volume backscattering strength (SV) calculated by the zooplankton collected with north pacific standard (NORPAC) net and the echo intensity measured with ADCP at stations on the study area in the spraying ocean of yellow loess (SOYL), and the non-spraying ocean of yellow ocean (NOYL) by the red tide generating every year. The species number and the individuals per unit volume of the zooplankton collected in NOYL was high and it which was collected in SOYL was low. As a result of comparing the volume backscattering strength ($SV_c$) calculated by species and length of the zooplankton collected with NORPAC net with the volume backscattering strength ($SV_m$) calculated by the echo intensity measured with ADCP at stations on the study area, although $SV_c$ and $SV_m$ of NOYL were generally in agreement, $SV_m$ of SOYL was higher than $SV_c$ 4.3dB, i.e. ADCP is greatly influenced by suspended solid in SOYL. The horizontal distribution map of $SV_m$ at the study area in autumn (Oct. 2008) and spring (Apr. 2009) was drawn. $SV_m$ of SOYL is higher than NOYL and autumn is higher than spring. $SV_m$ can suppress the overestimate or underestimate of $SV_c$.