• 제목/요약/키워드: horizontal r

검색결과 718건 처리시간 0.102초

수치영상을 이용한 도로평면선형 추출 (Extraction of Road Horizontal Alignment Using Digital Imagery)

  • 이종출;강인준;김남식;서동주
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2003년도 추계학술발표회 논문집
    • /
    • pp.123-128
    • /
    • 2003
  • Data acquired from digital Imagery were processed via Delphi, an object-oriented programming language to develop a computer aided program, that allows us to build up the information on road horizontal alignment(BC, EC, R, IP). And the developed program could maximize the visual effects better than traditional programs, because it used many image data. Comparing with data from traditional horizontal alignment extraction programs based on the principle of least square method, the data acquired by horizontal alignment information and kinematic GPS out of the developed road information systems showed the enhanced accuracy of IP value up to about 2m in the direction of X, Y axes, where the accuracy of curve radius(R) becomes enhanced up to about 2.5 m.

  • PDF

수평 T형 분지관 내 냉매 이상유동 분배특성에 미치는 변수들의 영향 (Effect of Parameters on the Two-Phase Flow Distribution Characteristics of Refrigerants in a Horizontal T-Junction)

  • 태상진;조금남
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.31-37
    • /
    • 2006
  • The present study has been experimentally investigated the effect of geometric and operating parameters on the two-phase flow distribution of refrigerants in a horizontal T-junction. The operating parameters were the kind of refrigerants (R-22, R- l34a, and R-410A), saturated temperature, and the inlet mass flux and quality. The geometric parameters were the tube diameter and the tube diameter ratio. The measured data of refrigerants were compared with the values predicted using the models developed by several researchers for air/water or steani/water two-phase flow. Among the operating parameters, the inlet Quality was the most sensitive to the mass flow rate ratio. Between the geometric parameters, the tube diameter ratio was more sensitive than tube diameter.

수평관내 3성분 혼합냉매의 강제대류비등 열전달 (Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube)

  • 오종택
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF

Application of GPS Surveying for Extracting Highway's Horizontal Alignment

  • Seo, Jeong-Hoon;Roh, Tae-Ho;Lee, Jong-Chool
    • Korean Journal of Geomatics
    • /
    • 제2권1호
    • /
    • pp.1-6
    • /
    • 2002
  • Korea is a small country with relatively large mountainous areas and has many difficulties from planning to completing one road. Maintaining a completed road presents even more difficulties. presently, in estimating design elements, the result varies according to the engineer and there are many cases that question the reliability of the results. Therefore, in this study, the alignment of highway was sampled using by the centerline path, the design elements of horizontal alignment were reduced by applying the Least Squares Method, and the accuracy was analyzed. By this method, IP, IA, R, $\Delta$R and A-parameter were also determined. By observing relatively long straight sections, the approximate values could be estimated, and particularly, the considerably accurate value of A-parameter was determined. This study, using the Least Squares Method, aims to contribute to the development of the alignment examination in frequent traffic accident regions.

  • PDF

수평 평활관에서 관직경 및 표면 과냉도가 R1234ze(E) 및 R1233zd(E) 막응축 열전달에 미치는 영향 (Effects of Tube Diameter and Surface Sub-Cooling Temperature on R1234ze(E) and R1233zd(E) Film Condensation Heat Transfer Characteristics in Smooth Horizontal Laboratory Tubes)

  • 전동순;고지운;김선창
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.231-238
    • /
    • 2017
  • HFO refrigerants have recently come to be regarded as promising alternatives to R134a for use in turbo chillers. This study provides results from experiments evaluating the film condensation heat transfer characteristics of HFO refrigerants R1234ze(E) and R1233zd(E) on smooth horizontal laboratory tubes. The experiments were conducted at a saturation vapor temperature of $38.0^{\circ}C$ with surface sub-cooling temperatures in the range of $3{\sim}15^{\circ}C$. We observe that the film condensation heat transfer coefficient decreases as surface sub-cooling temperatures increase. In the case of laboratory tubes with a diameter of 19.05 mm, the film condensation heat transfer coefficients of R1234ze(E) and R1233zd(E) were approximately 11% and 20% lower than those of R134a, respectively. Furthermore, our investigation of the effect of tube diameter on film condensation heat transfer coefficients, demonstrates an inverse relationship where the film condensation heat transfer coefficient increases as laboratory tube diameter decreases. We propose experimental correlations of Nusselt number for R1234ze(E) and R1233zd(E), which yield a ${\pm}20%$ error band.

R-410A 비등열전달에 미치는 미세관경 0.5mm와 3.0mm의 영향 (Flow Boiling Heat Transfer of R-410A in 0.5mm & 3.0mm Diameter Horizontal Tube)

  • ;최광일;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.154-159
    • /
    • 2008
  • Two-phase flow boiling heat transfer of R-410A in horizontal small tubes was reported in the present experimental study. The local heat transfer coefficients were obtained over a heat flux range of 5 to 40 kW/$m^2$, a mass flux range of 170 to 600 kg/$m^2s$, a saturation temperature range of 3 to $10^{\circ}C$, and quality up to 1.0. The test section was made of stainless steel tubes with inner diameters of 0.5 and 3.0 mm, and lengths of 330 and 3000 mm, respectively. The section was heated uniformly by applying a direct electric current to the tubes. The effects on heat transfer of mass flux, heat flux, inner tube diameter, and saturation temperature were presented. The experimental heat transfer coefficient is compared with six existing heat transfer coefficient correlations. A new boiling heat transfer coefficient correlation based on the superposition model for R-410A in small tubes was developed with mean deviation of 10.13%.

  • PDF

수평관내 이산화탄소의 증발 열전달 특성 (Evaporative Heat Transfer Characteristics of Carbon Dioxide in a Horizontal Tube)

  • 손창효;이동건;김영률;오후규
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1134-1139
    • /
    • 2004
  • The evaporative heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 7.75 mm. The experiments were conducted at mass flux of 200 to 500 kg/m$^2$s, saturation temperature of -5 to 5$^{\circ}C$, and heat flux of 10 to 40kW/m$^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much, and the effect of mass flux on evaporative heat transfer of $CO_2$ is much smaller than that of refrigerant R-22 and R-134a. In comparison with test results and existing correlations, correlations failed to predict the evaporative heat transfer coefficient of $CO_2$, therefore, it is necessary to develope reliable and accurate predictions determining the evaporative heat transfer coefficient of $CO_2$ in a horizontal tube.

수치사진측량을 이용한 도로평면선형정보체계 개발 (Development of Horizontal Alignment Information System of Road Using Digital Photogrammetry)

  • 서동주;이종출
    • 한국측량학회지
    • /
    • 제21권4호
    • /
    • pp.347-353
    • /
    • 2003
  • 최근 수치사진측량은 각종 첨단 산업분야에 그 응용이 증대되고 있으며, 많은 관심과 연구가 진행되고 있는 실정이다. 따라서 본 연구에서는 수치사진측량에 의한 도로평면선형정보체계 개발하였다 먼저 수치사진측량에서 취득된 자료들을 객체 지향적인 언어인 Delphi를 이용하여 도로평면선형정보(BC,EC,R,IP)를 구축하는 프로그램을 개발하였고, 개발된 프로그램은 영상자료를 많이 이용하여 기존보다 시각적인 효과를 극대화할 수 있었다. 그리고 개발한 도로평면선형정보의 제원 값은 동적GPS에 의해 취득된 자료를 최소제곱법의 원리를 이용한 평면선형추출 프로그램값과 비교하면, IP값은 약 X,Y방향으로 약 2m정도 정확도가 향상되었고, 곡선반경(R)은 약 2.5m정도의 정확도향상이 있었다.

Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant

  • Oh, Suseok;Ahn, Jaemyung;Nam, Ki-Uk;Paeng, Jun-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권2호
    • /
    • pp.71-76
    • /
    • 2013
  • Objectives: In three-dimensional computed tomography (3D-CT), the cant is evaluated by measuring the distance between the reference plane (or line) and the tooth. The purpose of this study was to determine the horizontal skeletal reference plane that showed the greatest correlation with clinical evaluation. Materials and Methods: The subjects were 15 patients who closed their eyes during the CT image taking process. The menton points of all patients deviated by more than 3 mm. In the first evaluation, clinical cant was measured. The distance from the inner canthus to the ipsilateral canine tip and the distance from the eyelid to the ipsilateral first molar were obtained. The distance between the left and right sides was also measured. In the second evaluation, skeletal cant was measured. Six reference planes and one line were used for the evaluation of occlusal cant: 1) FH plane R: Or.R - Or.L - Po.R; 2) FH plane L: Or.R - Or.L - Po.L; 3) F. Ovale plane R: Rt.F.Ovale - Lt.F.Ovale - Or.R; 4) F. Ovale plane L: Rt.F.Ovale - Lt.F.Ovale - Or.L; 5) FZS plane R: Rt.FZS - Lt.FZS - Po.R; 6) FZS plane R: Rt.FZS - Lt.FZS - Po.L, and; 7) FZS line: Rt.FZS - Lt.FZS. Results: The clinical and skeletal cants were compared using linear regression analysis. The FH plane R, FH plane L, and FZS line showed the highest correlation (P<0.05). Conclusion: The FH plane R and FH plane L are the most appropriate horizontal reference plane in evaluation of occlusal cant on 3D-CT.

자연냉매 프로판을 이용한 수평세관 증발기의 열전달 특성에 관한 연구 (Study on Heat Transfer Characteristics of Evaporator with Horizontal Small Diameter Tubes using Natural Refrigerant Propane)

  • 구학근
    • 동력기계공학회지
    • /
    • 제14권4호
    • /
    • pp.11-16
    • /
    • 2010
  • The evaporation heat transfer characteristics of propane(R-290) in horizontal small diameter tubes were investigated experimentally. The test tubes have inner diameters of 1 mm and 4 mm. Local heat transfer coefficients were measured at heat fluxes of 12, $24\;kW/m^2$, mass fluxes of 150, $300\;kg/m^2s$, and evaporation temperature of $15^{\circ}C$. The experimental results showed that the evaporation heat transfer coefficient of R-290 has an effect on heat flux, mass flux, tube diameter, and vapor quality. The evaporation heat transfer of R-290 has an influenced on nucleate boiling at low quality and convective boiling at high quality. The evaporation heat transfer coefficient of R-290 increases with decreasing inner tube diameter. And the evaporation heat transfer coefficient of R-290 is about 1~3 times higher than that of R-134a.