• Title/Summary/Keyword: horizontal offset

Search Result 66, Processing Time 0.023 seconds

Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

  • Park, Ji-Man;Kim, Hyun-Joo;Park, Eun-Jin;Kim, Myung-Rae;Kim, Sun-Jong
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.361-371
    • /
    • 2014
  • PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and $30^{\circ}$ oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at $30^{\circ}$, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the $30^{\circ}$ oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.

MEASUREMENT OF NUCLEAR FUEL ROD DEFORMATION USING AN IMAGE PROCESSING TECHNIQUE

  • Cho, Jai-Wan;Choi, Young-Soo;Jeong, Kyung-Min;Shin, Jung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.43 no.2
    • /
    • pp.133-140
    • /
    • 2011
  • In this paper, a deformation measurement technology for nuclear fuel rods is proposed. The deformation measurement system includes a high-definition CMOS image sensor, a lens, a semiconductor laser line beam marker, and optical and mechanical accessories. The basic idea of the proposed deformation measurement system is to illuminate the outer surface of a fuel rod with a collimated laser line beam at an angle of 45 degrees or higher. For this method, it is assumed that a nuclear fuel rod and the optical axis of the image sensor for observing the rod are vertically composed. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of the laser line beam position on the surface of the fuel rod is imaged as a parabolic beam in the high-definition CMOS image sensor. An ellipse model is then extracted from the parabolic beam pattern. The center coordinates of the ellipse model are taken as the feature of the deformed fuel rod. The vertical offset of the feature point of the nuclear fuel rod is derived based on the displacement of the offset in the horizontal direction. Based on the experimental results for a nuclear fuel rod sample with a formation of surface crud, an inspection resolution of 50 ${\mu}m$ is achieved using the proposed method. In terms of the degree of precision, this inspection resolution is an improvement of more than 300% from a 150 ${\mu}m$ resolution, which is the conventional measurement criteria required for the deformation of neutron irradiated fuel rods.

Mooring Cost Sensitivity Study Based on Cost-Optimum Mooring Design

  • Ryu, Sam Sangsoo;Heyl, Caspar;Duggal, Arun
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The paper describes results of a sensitivity study on an optimum mooring cost as a function of safety factor and allowable maximum offset of the offshore floating structure by finding the anchor leg component size and the declination angle. A harmony search (HS) based mooring optimization program was developed to conduct the study. This mooring optimization model was integrated with a frequency-domain global motion analysis program to assess both cost and design constraints of the mooring system. To find a trend of anchor leg system cost for the proposed sensitivity study, optimum costs after a certain number of improvisation were found and compared. For a case study a turret-moored FPSO with 3 ${\times}$ 3 anchor leg system was considered. To better guide search for the optimum cost, three different penalty functions were applied. The results show that the presented HS-based cost-optimum offshore mooring design tool can be used to find optimum mooring design values such as declination angle and horizontal end point separation as well as a cost-optimum mooring system in case either the allowable maximum offset or factor of safety varies.

Development and Positioning Accuracy Assessment of Precise Point Positioning Algorithms Based on GLONASS Code-Pseudorange Measurements

  • Kim, Mi-So;Park, Kwan-Dong;Won, Jihye
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.4
    • /
    • pp.155-161
    • /
    • 2014
  • The purpose of this study is to develop precise point positioning (PPP) algorithms based on GLONASS code-pseudorange, verify their performance and present their utility. As the basic correction models of PPP, we applied Inter Frequency Bias (IFB), relativistic effect, satellite antenna phase center offset, and satellite orbit and satellite clock errors, ionospheric errors, and tropospheric errors that must be provided on a real-time basis. The satellite orbit and satellite clock errors provided by Information-Analytical Centre (IAC) are interpolated at each observation epoch by applying the Lagrange polynomial method and linear interpolation method. We applied Global Ionosphere Maps (GIM) provided by International GNSS Service (IGS) for ionospheric errors, and increased the positioning accuracy by applying the true value calculated with GIPSY for tropospheric errors. As a result of testing the developed GLONASS PPP algorithms for four days, the horizontal error was approximately 1.4 ~ 1.5 m and the vertical error was approximately 2.5 ~ 2.8 m, showing that the accuracy is similar to that of GPS PPP.

Three Dimensional Finite Element Analysis on Stress Distribution According to the Bucco-lingual Inclination of the Implant Fixture and Abutment in the Mandibular Posterior Region (하악 구치부에서 임플란트 고정체와 지대주의 협설 기울기에 따른 응력분포에 관한 삼차원 유한요소 분석)

  • Lee, Hyun-Sook;Kim, Ji-Youn;Kim, Ye-Mi;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.371-392
    • /
    • 2011
  • The purpose of this study was to comparatively analyze the stress distribution according to the inclinations of abutments and angulations of the implant fixtures under occlusal loading force. Three study models with straight and $15^{\circ}$ and $25^{\circ}$-angled abutments were prepared following the insertion of Implants parallel to the long axis of the tooth. Additional two experimental models were fabricated with $15^{\circ}$ and $25^{\circ}$ fixture inclinations. Using ANSYS 11, a finite element analysis program, the magnitudes of stress distribution were analyzed. The magnitude of stress under loading was lowest when the load was applied vertically onto the axis of implant. And the magnitude of stress under compound(vertical+oblique) loading was increased as the inclination of implant abutment and fixture was increase. But, the distribution of stress was different as the loading conditions, because of the horizontal offset. As the offset between the axis of loading and the central axis of the implant increased, the stress was increased.

Normalized gestural overlap measures and spatial properties of lingual movements in Korean non-assimilating contexts

  • Son, Minjung
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.31-38
    • /
    • 2019
  • The current electromagnetic articulography study analyzes several articulatory measures and examines whether, and if so, how they are interconnected, with a focus on cluster types and an additional consideration of speech rates and morphosyntactic contexts. Using articulatory data on non-assimilating contexts from three Seoul-Korean speakers, we examine how speaker-dependent gestural overlap between C1 and C2 in a low vowel context (/a/-to-/a/) and their resulting intergestural coordination are realized. Examining three C1C2 sequences (/k(#)t/, /k(#)p/, and /p(#)t/), we found that three normalized gestural overlap measures (movement onset lag, constriction onset lag, and constriction plateau lag) were correlated with one another for all speakers. Limiting the scope of analysis to C1 velar stop (/k(#)t/ and /k(#)p/), the results are recapitulated as follows. First, for two speakers (K1 and K3), i) longer normalized constriction plateau lags (i.e., less gestural overlap) were observed in the pre-/t/ context, compared to the pre-/p/ (/k(#)t/>/k(#)p/), ii) the tongue dorsum at the constriction offset of C1 in the pre-/t/ contexts was more anterior, and iii) these two variables are correlated. Second, the three speakers consistently showed greater horizontal distance between the vertical tongue dorsum and the vertical tongue tip position in /k(#)t/ sequences when it was measured at the time of constriction onset of C2 (/k(#)t/>/k(#)p/): the tongue tip completed its constriction onset by extending further forward in the pre-/t/ contexts than the uncontrolled tongue tip articulator in the pre-/p/ contexts (/k(#)t/>/k(#)p/). Finally, most speakers demonstrated less variability in the horizontal distance of the lingual-lingual sequences, which were taken as the active articulators (/k(#)t/=/k(#)p/ for K1; /k(#)t/

Zero-Offset VSP Data Processing for Gas Hydrate-Bearing Sediments in East Sea (동해 가스하이드레이트 부존지역 제로오프셋 VSP 탐사 자료의 자료처리)

  • Kim, Myung-Sun;Byun, Joong-Moo;Yoo, Dong-Geun
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.255-262
    • /
    • 2009
  • Conventionally, vertical-seismic-profiling (VSP) survey that provides high-resolution information has mainly performed to obtain the exact depth of the gas hydrate-bearing sediment, which is one of the key factors in the development of the gas hydrate. In this study, we extracted interval velocities and created corridor stacks from the first domestic zero-offset VSP data, which were acquired with three component receivers at UBGH09 borehole in Ulleung Basin where gas hydrate exists. Then we compared the corridor stacks with a CMP stacked section from surface seismic data. First of all, we converted the signals recorded with three component receivers to true vertical and horizontal components by phase rotation, and divided the data into direct waves and reflected waves by wavefield separation processing. The trend of the interval velocity extracted from the zero-offset VSP was similar to that of the sonic log obtained at the same borehole. Because the interval velocity of the gas hydrate-bearing sediment above the BSR was high, and it decreased suddenly through the BSR, we could infer that free gas is accumulated below the BSR. The results of comparing the corridor stacks to the CMP stacked section of the surface seismic data showed that most reflection events agreed well with those in the surface CMP stacked section and that the phase-rotated VSP data corresponded better with the surface seismic data than the VSP data without phase rotation. In addition, by comparing a corridor stack produced from the transverse component with the CMP stacked section of the surface seismic data, we could identify PS mode-converted reflections in the CMP stacked section.

A Study on Real-time Control of Bead Height and Joint Tracking Using Laser Vision Sensor

  • Kim, H. K.;Park, H.
    • International Journal of Korean Welding Society
    • /
    • v.4 no.1
    • /
    • pp.30-37
    • /
    • 2004
  • There have been continuous efforts on automating welding processes. This automation process could be said to fall into two categories, weld seam tracking and weld quality evaluation. Recently, the attempts to achieve these two functions simultaneously are on the increase. For the study presented in this paper, a vision sensor is made, a vision system is constructed and using this, the 3 dimensional geometry of the bead is measured on-line. For the application as in welding, which is the characteristic of nonlinear process, a fuzzy controller is designed. And with this, an adaptive control system is proposed which acquires the bead height and the coordinates of the point on the bead along the horizontal fillet joint, performs seam tracking with those data, and also at the same time, controls the bead geometry to a uniform shape. A communication system, which enables the communication with the industrial robot, is designed to control the bead geometry and to track the weld seam. Experiments are made with varied offset angles from the pre-taught weld path, and they showed the adaptive system works favorable results.

  • PDF

CAD/CAM/CAT Turmaround System for Precision Machining (정밀가공을 위한 CAD/CAM/CAT 일괄처리시스템)

  • 안중용;김승철;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.417-422
    • /
    • 1993
  • In order to minimize turnaround of machining in FMS lines, CAD/CAM/CAT integrated system called MascCAM was developed. Developing enhanced CAM and inspection modules in the MascCAM environment, 2D came, 2 $^{1}$2/ D prismatic parts and 3D free-formed surfaces were able to be automatically designed, manufactured and inspected on the machine tools by using AutoCAM and Z-map. Introducing Z-map technique, the MascCAM was able to be interfaceed with and CAD system. Developed QPPGT module generates a quick and fool-proof inspection work to users. A vertical and a horizontal machining center equipped with FANUC OMC were used for experiments. Performance of the system was confirmed by a large amount of experiments.

  • PDF

A method of contouring occlusal surface for reduction of implant overload (Implant overload 감소를 위한 교합면 형성 방법)

  • Lee, Byung-Woo;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.105-108
    • /
    • 2003
  • After stage-two surgery, the highest incidence of failure has been attributed to implant overload. However, the biomechanical factors cited inthe literature that contribute to implant overload, such as bone type, cuspal inclination, horizontal offset, maxillary compared to mandibular arch, the inclusion of natural teeth within the prosthesis, and occlusal harmony are superimposed on physiologic variations. Following two cases, including reduction of cuspal inclination and usage of modified incisal pin, showed a method of contouring occlusal surface for reduction of unpreditable implant overload.