• 제목/요약/키워드: horizontal drainage pipe

검색결과 12건 처리시간 0.024초

비굴착 지하배수암거 형태별 지하배수 성능 비교분석 (Comparative Study on the Subsurface Drainage Discharge Performance by the Type of Non-Excavation Subsurface Drainage Culvert)

  • 김현태;유전용;정기열;서동욱
    • 한국농공학회논문집
    • /
    • 제60권6호
    • /
    • pp.73-81
    • /
    • 2018
  • In this study, subsurface discharge performance has been studied through theoretical seepage analysis on four types of culverts that can be installed under the condition of non-excavation, such as (a)perforated pipe(${\Phi}50mm$), (b)perforated pipe+horizontal mat (B50cm) (c)perforated pipe+horizontal mat+vertical gravel(B<10cm), (d)perforated pipe+vertical gravel(B<10cm), and existing typical type (e)perforated pipe with gravel (B40, h=40cm) which can be installed by excavation. The analysis results were as follows. i) Subsurface discharge performance per unit (m) was (a)type 56%, (b) 91%, (c) 96%, (d) 76%, respectively, lower than the value of (e)culvert. ii) However, considering that non-excavation culvert can be installed at a spacing of 5m with the installation cost of the existing excavation culvert at the interval of 10m, it was analyzed that unit subsurface discharge(q) of (a)20.2mm/day(110%), (b)32.8(178%), (c)34.6(188%) (d)27.5(149%) in the four types of non-excavation culvert installed at intervals of 5m under the condition of $ k=10^{-4}cm/s$ was much larger than the amount of (e)type 18.5(100%), existing excavation culvert installed at 10m interval. iii) Through the test construction, peak subsurface drainage discharge($q_p$) was 38.4mm/day, which is larger than the value of design criteria and confirmed that it satisfies the analysis results as well. iv) In particular, it was evaluated that (b)perforated pipe+horizontal mat(B50cm) are low cost, high efficiency subsurface drainage culvert type with sufficient drainage performance(178%).

선재하 수평배수관망 시스템의 적용성 평가 (Evaluation of Applicability of Platform Fill Horizontal Drain Pipe System)

  • 유찬호;한연진;강수용;백승철
    • 한국지반환경공학회 논문집
    • /
    • 제13권3호
    • /
    • pp.77-83
    • /
    • 2012
  • 연약지반 개량공법에 있어서 대부분의 수평 배수층은 모래나 쇄석 등의 골재를 이용하고 있으나, 이러한 골재를 수평 배수층으로 사용하는 경우에는 종종 원지반의 침하불량을 유발하는 경우가 발생하고 있다. 이에 수평 배수층을 깔지 않고 수평 배수용 파이프를 이용하는 수평배수관망 시스템이 개발되어 적용되고 있다. 이러한 공법은 반복 성토과정으로 발생하는 과잉 간극수압을 수평 배수관망으로 직접 배수하는 시스템이다. 본 연구에서는 수평배수관망 시스템의 적용성과 시공성을 확인하고자 실 규모 현장시험 시공을 수행하여 수평배수관망 시스템의 적용성을 평가하였다. 현장시험시공을 통하여 수평 배수관망 시스템의 침하 거동특성을 살펴보았으며, 또한 수평배수관망 변형정도를 확인하여 일반적인 수평배수층을 이용하는 공법과 비교분석하여 그 효용성을 확인하였다.

배수재의 직경과 형상변화가 수평진공배수에 미치는 영향 (Effects of Size and Shape of Drain on Horizontal Vacuum Drain)

  • 유남재;박병수;정길수;이병곤
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

수평배수관망을 이용한 연약지반 처리공법의 적용성 평가 (Application on Soft Ground Improvement Method using Horizontal Drainge Pipe System)

  • 유찬호;강수용;홍순용;김홍택
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1158-1163
    • /
    • 2009
  • In this study, PSD system to improve the soft ground was developed by using a horizontal drainage pipe. PSD system is direct drain method for the disappearance of excess pore-water pressure which is caused by fill on soft ground. To conduct the field test construction in order to evaluate application of the PSD system. To estimate the behavior characteristics on settlement in which constructed by PSD system and compared the behavior characteristics with the conventional soft ground improvement method result.

  • PDF

대변기 세정시 발생하는 배수소음의 특성변화에 관한 연구 (A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing)

  • 설수환;정철운;김재수
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.789-796
    • /
    • 2007
  • It has been noted, in case of the apartments in collective form, the drainage noise from cleaning of toilet causes many problems in the basement and adjacent rooms, mainly hampering the pleasant housing environment. The problems are increasingly raised by civil complaints with the public offices. Therefore, if the drainage noise generates when wash out of toilet bowl is grasped how the characteristics change according to the sorts of drainpipe, it is considered that the establishment of an effective sound insulation countermeasure could be possible when a civil petition against the drainage noise of apartment house is submitted hereafter. On such viewpoint, this study measured and analyzed the characteristics of drainage noise per the type of drainage pipe, according to KS A ISO $1996-1{\sim}3$, with the horizontal branch pipe and riser pipes in the drainage noise experiment chamber which has the characteristics of the anechoic room. In the result, the pipe type with excellent noise reduction function. The result of this study is considered to become available as fundamental data, to take actions on reduction of drainage noise of the ceiling piping method.

간척지 흙의 암거 설치조건에 따른 제염 특성의 이론적 해석 (Theoretical Analysis of Soil Desalination Characteristics for Underdrain System at Reclaimed Tidal Land)

  • 김현태;서동욱;류찬호;김석열
    • 한국농공학회논문집
    • /
    • 제57권3호
    • /
    • pp.87-92
    • /
    • 2015
  • Cultivation on reclaimed tidal land is often difficult in the problem such as high salinity of soil, bad drainage because of high level of groundwater. Many researches have been made efforts to solve these problems, but effect of improvement is low and practicality is insufficient. In this study, through numerical analysis of the transport properties of salt and water, we suggested underground drainage of the reclaimed land and the desalination promotion methods in the soil. The results of characteristic of desalination and seepage analysis of underdrain show that underdrain is able to increase twice of the underground seepage amount when installing perforated pipe with horizontal filter (width 50cm) more than installing only the perforated pipe. For soil which coefficient of permeability is below $1{\times}10^{-4}cm/s$ that desalination with pond water is not possible, a method to increase the permeability of the soil is necessary. Therefore, it was concluded that application of underdrain using perforated pipe with horizontal filter would be low-cost and practical.

공동주택 욕실 배수배관 자재 구성에 따른 양변기 배수소음 저감 특성 (Characteristics of Reducing the Water-drainage Noise of Toilet-bowl According to the Composition of Water Drainage Piping Materials of the Bathrooms of Apartment Housing)

  • 정아영;김경우;신혜경;양관섭
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.114-120
    • /
    • 2017
  • Water supply and drainage noise in the bathroom is recognized as one of the main noises, along with the floor-impact sounds, in apartment housings. Recently, to solve such noise issues, a new construction method of installing the piping on the slab has been adopted. rather than the traditional method of penetrating the piping through the slab between the upper and the lower bathrooms. However, this new method has limitations due to high costs and constructional difficulties. Therefore, this study was conducted to develop noise reducing piping and elbows, where the noise can be reduced simply by replacing the existing pipings. The noise level was measured in a laboratory by installing the horizontal drainage piping (three types) and the elbows (three types) developed in this study. The results showed that the horizontal pipings reduced the noise level in LAmax by 0.3 dB(A)~1.0 dB(A), as compared to the existing pipings (VG2), indicating an insignificant noise reduction effect. The elbow reduced the noise level in LAmax by 5.5 dB(A) ~ 11.5 dB(A), as compared to the existing elbow (DRF elbow), with the result of reducing the noise level at all frequencies evenly. Consequently, it was shown that using the elbows is more effective in reducing the water-drainage noise from the toilet than using the horizontal pipings.

원형 수평앵커를 이용한 파이프 골조 온실기초의 인발저항럭 개선에 관한 연구 (A Study on the Uplift Capacity Improvement of Pipe-framed Greenhouse Foundation Using Circular Horizontal Anchors)

  • 윤용철;이근후;유찬
    • 한국관개배수논문집
    • /
    • 제10권2호
    • /
    • pp.55-61
    • /
    • 2003
  • Bench scale experiments have been carried out to evaluate the adaptability of the anchor for improving the uplift capacity of foundation of pipe framed greenhouse which is typically adopted in conventional plastic film glazing greenhouses, such as 1-2W ty

  • PDF

수평 배수재로서 순환골재와 쇄석의 활용 방안 (Utilization of Recycled Aggregates and Crushed Stone as Horizontal Drains in Soft Ground)

  • 이달원;임진혁
    • 한국농공학회논문집
    • /
    • 제52권6호
    • /
    • pp.111-123
    • /
    • 2010
  • In this study, laboratory model test on utilization of recycled aggregates and crushed stone as horizontal drains to use alternative material of sand in soft ground is practiced. The coefficient of permeability of the recycled aggregates and crushed stone showed largely 1.2~5.1 times and 2.0~3.3 times greater than sand, respectively. The horizontal coefficient of permeability in case of installing the horizontal perforated drain pipe showed largely 1.9~6.8 times more than the case of not installing. The drainage distance showed 1.7~1.8 times greater than sand. When a degree of consolidation is 90 %, there is no delay of consolidation in SCP and PVD improvement sections. Therefore, it is proven that the field applicability is excellent. Also, the suitable quality management criterion is presented to make use of a horizontal drains in soft ground on the basis of analysis of the physical and environmental characteristics.

과부하 사각형 맨홀의 배수능력 증대에 관한 실험적 연구 (An Experimental Study for Drainage Capacity Increment at Surcharged Square Manholes)

  • 김정수;송주일;윤세의
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.619-625
    • /
    • 2008
  • Urban sewer systems are designed to operate in open-channel flow regime and energy loss at square manholes is usually not significant. However, the energy loss at surcharged manholes is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the head loss associated with manholes, especially in surcharged flow. Hydraulic experimental apparatus which can change the manhole inner profile(CASE I, II, III, and IV) and the invert types(CASE A, B, C) were installed for this study. The experimental discharge was $16{\ell}/sec$. As the ratio of b/D(manhole width/inflow pipe diameter) increases, head loss coefficient increases due to strong horizontal swirl motion. The head loss coefficients for CASE I, II, III, and IV were 0.46, 0.38, 0.28 and 0.37, respectively. Side covers increase considerably drainage capacity at surcharged square manhole when the ratio of d/D(side cover diameter/inflow pipe diameter) was 1.0. The head loss coefficients for CASE A, B, and C were 0.45, 0.37, and 0.30, respectively. Accordingly, U-invert is the most effective for energy loss reduction at surcharged square manhole. This head loss coefficients could be available to evaluate the urban sewer system with surcharged flow.