• Title/Summary/Keyword: historical structures

Search Result 285, Processing Time 0.025 seconds

The Evolution and Structural Characteristics of Scaffolding Constructions in Macao Area from Historical Documents and Visual Materials (문헌 및 도상(圖像) 사료를 통해 본 마카오 '붕식(棚式)' 건축의 연원(淵源)과 구조 형식)

  • Hong, Shu-ying;Han, Dong-Soo
    • Journal of architectural history
    • /
    • v.32 no.1
    • /
    • pp.7-20
    • /
    • 2023
  • The construction method of scaffolding structures is different from Mortise and Tenon and bucket arch structure of traditional large woodwork. It forms an independent construction system-fixing nodes with knots, a large number of diagonal braces are used to fix shelves and the structures mostly contain X-shape and triangular shape details. Simple ones include stalls, sheds, rain sheds, altars, lamp racks etc. But the scaffolding with larger scale and more complicated structure are modeled on archways, theatres and other buildings which are used in commercial and festival activities. At present, Macao, Hong Kong, Guangdong, Sichuan, Shanxi and other places in China have retained the custom of using scaffolding structures in important festival activities, but their uses, techniques and building types are slightly different from place to place. Due to building and demolishing at any time, the construction and service cycle is short. As a result, there are almost no physical objects left. We can only deduce the use and technical characteristics of ancient scaffolding skills through the colorful building styles that have been preserved with folk activities in various parts of China, the craftsmanship handed down from generation to generation by the scaffolding guild and artisans, and the description of cultural and historical materials and the mutual corroboration of visual materials.

Health monitoring of a historical monument in Jordan based on ambient vibration test

  • Bani-Hani, Khaldoon A.;Zibdeh, Hazem S.;Hamdaoui, Karim
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.195-208
    • /
    • 2008
  • This paper summarizes the experimental vibration-based structural health monitoring study on a historical monument in Jordan. In this work, and within the framework of the European Commission funded project "wide-Range Non-Intrusive Devices Toward Conservation of Historical Monuments in the Mediterranean Area", a seven and a half century old minaret located in Ajloun (73 km north of the capital Amman) is studied. Because of their cultural value, touristic importance and the desire to preserve them for the future, only non-destructive tests were allowed for the experimental investigation of such heritage structures. Therefore, after dimensional measurements and determination of the current state of damage in the selected monument, ambient vibration tests are conducted to measure the accelerations at strategic locations of the system. Output-only modal identification technique is applied to extract the modal parameters such as natural frequencies and mode shapes. A Non-linear version of SAP 2000 computer program is used to develop a three-dimensional finite element model of the minaret. The developed numerical model is then updated according to the modal parameters obtained experimentally by the ambient-vibration test-results and the measured characteristics of old stone and deteriorated mortar. Moreover, a parametric identification method using the N4Sid state space model is employed to model the dynamic behavior of the minaret and to build up a robust, immune and noise tolerant model.

A comparative analysis of seismic and structural parameters for historical period earthquakes in Türkiye

  • Ercan Isik
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.377-391
    • /
    • 2023
  • The high seismic risk has once again revealed in Türkiye with two major earthquakes that occurred on 06.02.2023, which took its place among the most destructive earthquakes in the last century. Totally, 65 earthquakes that occurred in the historical period in Türkiye were taken into account within the scope of this study. The seismic parameters were compared by considering the last two earthquake hazard maps for the epicenters of these earthquakes. Earthquake Intensity (I) of historical earthquakes were converted to Peak Ground Acceleration (PGA) by using suggested relations. Structural analyzes were performed for a sample reinforced-concrete building by using the obtained PGA's and predicted PGA's in the last two earthquake hazard maps. In the structural analysis, two different material groups such as low (C12-S220) and normal (C25-S420) were selected. As the material strength increased, the period value decreased, while the seismic capacity and stiffness increased. It has been determined that there are differences between the measured and proposed seismic risks for some earthquakes, and as a result, there are significant differences between the expected target displacement values from the structures. Therefore, it will not be possible to estimate the damage and to determine the building performance realistically. The main purpose of the study is to reveal whether the earthquake risk is adequately represented on seismic and structural parameters.

Seismic performance of the historical masonry clock tower and influence of the adjacent walls

  • Cakir, Ferit;Uysal, Habib
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.217-231
    • /
    • 2014
  • Ancient masonry towers are regarded as among the most important historical heritage structures of the world. These slender structures typically have orthogonal and circular geometry in plane. These structural forms are commonly installed with adjacent structures. Because of their geometrical shapes and structural constraints, ancient masonry towers are more vulnerable to earthquake damage. The main goal of the paper is to investigate the seismic behavior of Erzurum Clock Tower under earthquake loading and to determine the contribution of the castle walls to the seismic performance of the tower. In this study, four three-dimensional finite element models of the Erzurum Clock Tower were developed and the seismic responses of the models were investigated. Time history analyses were performed using the earthquakes that took place in Turkey in 1983 near Erzurum and in 1992 near Erzincan. In the first model, the clock tower was modeled without the adjacent walls; in the second model, the clock tower was modeled with a castle wall on the south side; in the third model, the clock tower was modeled with a castle wall on the north side; and in the last model, the clock tower was modeled with two castle walls on both the north and south sides. Results of the analyses show that the adjacent walls do not allow lateral movements and the horizontal displacements decreases. It is concluded that the adjacent structures should be taken into consideration when modeling seismic performance in order to get accurate and realistic results.

A Study on the Historical Inquiry of TV Historical Drama Costumes (TV사극 드라마 의상의 고증에 관한 연구)

  • 봉현숙;이상은
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.2 no.2
    • /
    • pp.113-136
    • /
    • 2000
  • Problems and improvemental measures for the historical inquiry of TV drama costumes and for the reproduction of them were investigated. For this study, the MBC historical drama 'The way of the Great King' started on march 24 in 1998 and ended on september 26 in 1998 was selected as the subject. The reasons why the drama was selected are as follows. First, the historical background was the time of King Young & drama introduced various kinds of costumes Joungjo, which is the starting era of traditional costumes peculiar to Korea. Second, the based on the historical inquiry of that time. There is a limitation in the process of historical inquiry about the costumes of that time because we don't have enough research data such as relics, remains, references, literary works, pictures, etc. Although, in some cases, exact historical inquiry about the costumes were made, they could not be reproduced in the original forms due to several reasons: the absence of the materials of that time, structural changes including length and size for convenience of action, alterations of the manufacturing method for the reuse, addition of the gorgeous and various olors for the enhancement of image quality, variations in colors according to the actor's character, modulations of the structures and colors by the producer's intention, and the restraints in time and money for manufacturing. In view of these situations, it seems to be difficult for us to settle the problems occurring between the historical inquiry about the traditional costumes and the reproduction of them in drama. However, the costumes presented in historical drama have the meanings to provide informations of that time with TV audience. Therefore I think that it is necessary to narrow the gap between the historical inquiry of TV drama costumes and for the reproduction of hem, First, It should be restrained that each broadcasting stations show the costumes under the similar situations of the same age in different ways. Second, We need to unify the inquiry systems concerning historical drama costumes, In addition to this, it is also necessary for broadcasting stations to establish internet sites of traditional costumes for communication.

  • PDF

Practical seismic assessment of unreinforced masonry historical buildings

  • Pardalopoulos, Stylianos I.;Pantazopoulou, Stavroula J.;Ignatakis, Christos E.
    • Earthquakes and Structures
    • /
    • v.11 no.2
    • /
    • pp.195-215
    • /
    • 2016
  • Rehabilitation of historical unreinforced masonry (URM) buildings is a priority in many parts of the world, since those buildings are a living part of history and a testament of human achievement of the era of their construction. Many of these buildings are still operational; comprising brittle materials with no reinforcements, with spatially distributed mass and stiffness, they are not encompassed by current seismic assessment procedures that have been developed for other structural types. To facilitate the difficult task of selecting a proper rehabilitation strategy - often restricted by international treaties for non-invasiveness and reversibility of the intervention - and given the practical requirements for the buildings' intended reuse, this paper presents a practical procedure for assessment of seismic demands of URM buildings - mainly historical constructions that lack a well-defined diaphragm action. A key ingredient of the method is approximation of the spatial shape of lateral translation, ${\Phi}$, that the building assumes when subjected to a uniform field of lateral acceleration. Using ${\Phi}$ as a 3-D shape function, the dynamic response of the system is evaluated, using the concepts of SDOF approximation of continuous systems. This enables determination of the envelope of the developed deformations and the tendency for deformation and damage localization throughout the examined building for a given design earthquake scenario. Deformation demands are specified in terms of relative drift ratios referring to the in-plane and the out-of-plane seismic response of the building's structural elements. Drift ratio demands are compared with drift capacities associated with predefined performance limits. The accuracy of the introduced procedure is evaluated through (a) comparison of the response profiles with those obtained from detailed time-history dynamic analysis using a suite of ten strong ground motion records, five of which with near-field characteristics, and (b) evaluation of the performance assessment results with observations reported in reconnaissance reports of the field performance of two neoclassical torsionally-sensitive historical buildings, located in Thessaloniki, Greece, which survived a major earthquake in the past.

Effect of model calibration on seismic behaviour of a historical mosque

  • Demir, Ali;Nohutcu, Halil;Ercan, Emre;Hokelekli, Emin;Altintas, Gokhan
    • Structural Engineering and Mechanics
    • /
    • v.60 no.5
    • /
    • pp.749-760
    • /
    • 2016
  • The objective of the study is to investigate the effects of model calibration on seismic behaviour of a historical mosque which is one of the most significant Ottomon structures. Seismic analyses of calibrated and noncalibrated numeric models were carried out by using acceleration records of Kocaeli earthquake in 1999. In numerical analysis, existing crack zones on real structure was investigated in detail. As a result of analyses, maximum stresses and displacements of calibrated and noncalibrated numerical models were compared each other. Consequently, seismic behaviour and damage state of historical masonry Hafsa Sultan mosque was determined as more realistic in the event of a severe earthquake.