• 제목/요약/키워드: histomorphometric evaluation

검색결과 58건 처리시간 0.027초

이온빔 보조 전자빔 수산화 인회석 증착이 골내 임플란트의 골유착에 미치는 영향 (EFFECTS OF THE ION BEAM ASSISTED DEPOSITION OF HYDROXYAPATITE ON OSSEOINTEGRATION OF THE ENDOSSEOUS IMPLANTS IN RABBIT TIBIAE)

  • 정영철;한종현;이인섭;이현정;김명호
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.659-674
    • /
    • 2000
  • A large increase in the use of thin film coating of hydroxyapatite(HA) in implant dentistry is driven by the desire to take advantage of the excellent biocompatibility and high strength of HA coating. The purpose of this study was to evaluate the effects of HA-coated implants by ion Beam Assisted Deposition(IBAD) method in comparison to the sand-blasted and machined surfaces. Osteoblast culture test, removal torque test and histomorphometric analysis were performed and the following results obtained; 1. Examination of the osteoblast cultures displayed no difference in the secretion of alkaline phosphatase between the various specimen, but IBAD with pure HA specimen showed low alkaline phosphatase secretion(p<0.05). 2. Removal torque tests showed HA-coated implants by IBAD method to be similar in high value to the implants with sand-blasted surface than the implants with machined surface. And the ovariectomized group showed low mechanical test value than the normal group(p<0.05). 3. Histomorphometrical comparisons were performed on undecalcified ground sections. HA-coated implants by IBAD method demonstrated the highest mean bone-to-metal contact ratio on all threads and 3-best consecutive threads, and the implants with sand-blasted surface and implants with machined surface was in the next consecutive order(p<0.05). HA-coated implants showed slightly higher bone-to- metal contact ratio than sand-blasted implants, but no statistically significant difference was obtained between the two materials. The ovariectomized group showed lower value of bone-to-metal contact ratio than the normal group, but no statistically significant difference was obtained between the two groups. 4. Evaluation of bone volume on all threads and 3-best consecutive threads showed no statistically significant difference among the different surface treatment groups, but showed lower bone volume in ovariectomized group than in the normal group(p<0.05). According tn these results, thin film coated implants with HA showed high bone contact ratio, bone volume and removal torque strength in the short term, but long term observation is needed.

  • PDF

Evaluation of tissue ingrowth and reaction of a porous polyethylene block as an onlay bone graft in rabbit posterior mandible

  • Sosakul, Teerapan;Tuchpramuk, Pongsatorn;Suvannapruk, Waraporn;Srion, Autcharaporn;Rungroungdouyboon, Bunyong;Suwanprateeb, Jintamai
    • Journal of Periodontal and Implant Science
    • /
    • 제50권2호
    • /
    • pp.106-120
    • /
    • 2020
  • Purpose: A new form of porous polyethylene, characterized by higher porosity and pore interconnectivity, was developed for use as a tissue-integrated implant. This study evaluated the effectiveness of porous polyethylene blocks used as an onlay bone graft in rabbit mandible in terms of tissue reaction, bone ingrowth, fibrovascularization, and graft-bone interfacial integrity. Methods: Twelve New Zealand white rabbits were randomized into 3 treatment groups according to the study period (4, 12, or 24 weeks). Cylindrical specimens measuring 5 mm in diameter and 4.5 mm in thickness were placed directly on the body of the mandible without bone bed decortication, fixed in place with a titanium screw, and covered with a collagen membrane. Histologic and histomorphometric analyses were done using hematoxylin and eosin-stained bone slices. Interfacial shear strength was tested to quantify graft-bone interfacial integrity. Results: The porous polyethylene graft was observed to integrate with the mandibular bone and exhibited tissue-bridge connections. At all postoperative time points, it was noted that the host tissues had grown deep into the pores of the porous polyethylene in the direction from the interface to the center of the graft. Both fibrovascular tissue and bone were found within the pores, but most bone ingrowth was observed at the graft-mandibular bone interface. Bone ingrowth depth and interfacial shear strength were in the range of 2.76-3.89 mm and 1.11-1.43 MPa, respectively. No significant differences among post-implantation time points were found for tissue ingrowth percentage and interfacial shear strength (P>0.05). Conclusions: Within the limits of the study, the present study revealed that the new porous polyethylene did not provoke any adverse systemic reactions. The material promoted fibrovascularization and displayed osteoconductive and osteogenic properties within and outside the contact interface. Stable interfacial integration between the graft and bone also took place.

Effect on bone formation of the autogenous tooth graft in the treatment of peri-implant vertical bone defects in the minipigs

  • Kim, Seok Kon;Kim, Sae Woong;Kim, Kyung Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.2.1-2.9
    • /
    • 2015
  • Background: The aim of this study was to evaluate the effect of autogenous tooth bone as a graft material for regeneration of bone in vertical bony defects of the minipigs. Material and Methods: Six minipigs were used in this study. Four molars were extracted in the right mandibular dentition and sent to the Korea Tooth Bank for fabrication of autogenous tooth bone. Ten days later, each extraction site was implanted with MS Implant Narrow Ridge $3.0{\times}10mm$ fixture (Osstem, Seoul, Korea) after standardized 2mm-sized artificial vertical bony defect formation. Pineappleshaped Root-On type autogenous tooth bones were applied to the vertical defects around the neck area of the posterior three fixtures and the fore-most one was not applied with autogenous bone as a control group. Each minipig was sacrificed at 4, 8, 12 weeks after fixture installation and examined radiologically and histologically. Histological evaluation was done under light microscope with Villanueva osteochrome bone staining with semi-quantitative histomorphometric study. Percentage of new bone over total area (NBF) and bone to implant contact (BIC) ratio were evaluated using digital software for area calculation. Result: NBF were $48.15{\pm}18.02%$, $45.50{\pm}28.37%$, and $77.13{\pm}15.30%$ in 4, 8, and 12 weeks, respectively for experimental groups. The control group showed $37.00{\pm}11.53%$, $32.25{\pm}26.99%$, and $1.33{\pm}2.31%$ in 4,8,12 weeks, respectively. BIC ratio were $53.08{\pm}19.82%$, $45.00{\pm}28.37%$, and $75.13{\pm}16.55%$ in 4,8,12 weeks, respectively. Those for the control groups were $38.33{\pm}6.43%$, $33.50{\pm}29.51%$, and $1.33{\pm}2.31%$ in 4, 8, 12 weeks, respectively. Conclusion: Autogenous tooth bone showed higher score than control group in NBF and BIC in all the data encompassing 4,8,12 weeks specimens, but statistically significant only 12 weeks data in both NBF and BIC.

갑상선기능항진증에서 $^{99m}Tc-MDP$ 24시간 정체율과 Osteocalcin (24hr Whole-Body Retension of $^{99m}Tc-Methylene$ Diphosphonate and Osteocalcin in patients with Hyperthyroidism)

  • 염광섭;이진오;강태웅;홍성운;임상무
    • 대한핵의학회지
    • /
    • 제24권2호
    • /
    • pp.222-228
    • /
    • 1990
  • The development of histomorphometric and histodynamic investigations has permitted the description of a specific and complex osteopathy in hyperthyroidism. The increased bone turnover rate in hyperthyroid patients may be accompanied by a considerable bone loss. These features are associated with both inclosed osteoclastic bone resorption and increased osteoblastric bone formation, with an accelerated calcification rate. Conventional biochemical markers of bone metabolism, i.e. serum calcium and alkaline phosphatase and urinary hydroxyproline and calcium are normal in most patients with hyperthyroidism. However, the correlation between serum BGP and serum concentration of thyroid hormon suggests that serum BGP may be a sensitive marker of increased bone formation due to the hypersecretion of thyroid hormones. Any increase in bone turnover, whether focal or diffuse, will result in an increase in $^{99m}Tc-methylenediphosphonate$ uptake (MDP). The measurement of this uptake in hyperthyroid patients by bone provides a sensitive and objective means of quantifying skeletal metabolism. Using a standard shadow-shield whole-body monitor and radioimmunoassay kit, we have measured whole-body retention of $^{99m}Tc-MDP$ up to 24hr and concentration of serum Osteocalcin in 20 patients with hyperthyroidism and in 42 normals. The results were as follows; 1) The average of serum Osteocalcin level in 42 patients with normals was $9.90{\pm}4.87(ng/ml)$ and in 20 patients with hyperthyroidism was $19.54{\pm}5.7(ng/ml)$. Both the averages of serum Osteocalcin and 24hr $^{99m}Tc-MDP$ uptakes in hyperthyroid patients were higher than those in normals. 2) $^{99m}Tc-MDP$ uptakes in skeletal system increased in proportion to normal ageing after 40 yrs old in 42 patients with normals. The average of $^{99m}Tc-MDP$ uptakes in hyperthyroid patients were higher than those in normals without related ageing. 3) A significant relationships between the $^{99m}Tc-MDP$ uptakes and serum Osteocalcin level were peformed (r=0.55, $y=17.58+6.7\times$). From the above results we concluded that the measurement of serum Osteocalcin and 24hr $^{99m}Tc-MDP$ uptakes can be used for evaluation of bone turnover as a specific marker in hyperthyroid patients.

  • PDF

임플란트 매식시 골형성단백질 및 탈회동종골 사용에 따른 골재생 및 계면에 대한 연구 (EVALUATION OF THE INTERFACES BETWEEN IMPLANTS AND REGENERATED BONE USING BONE MORPHOGENETIC PROTEIN AND DEMINERALIZED FREEZE-DRIED BONE)

  • 강상규;이종호;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권1호
    • /
    • pp.24-39
    • /
    • 2000
  • Various methods and graft materials have been used to fill in the defect adjacent to the implants and considered as clinically acceptable. But it is not clear whether the regenerated bone increases the implant-bone contact and supports the implant. The purpose of this study is to evaluate regenerated bone surrounding implants using bone morphogenetic protein(BMP) and demineralized freeze-dried bone(DFDB), and the interfaces between implants and regenerated bone. bBMP was extracted and partially purified from the bovine bone matrix using heparine chromatography. Demineralized freeze-dried bone was made from the dog. Inactive insoluble collagenous bone matrix(IBM) of dog was used as carrier of bBMP. Interfaces of titanium coated epoxy resin implants were processed for demineralized section for transmission electron microscopy(TEM) and those of screw type implants were for nondemineralized section for light and fluoromicroscopic examination. Implants were inserted in the inferior border of mandible of adult dogs and artificial bony defects($3{\times}3{\times}4mm$) were made at the mesial and distal side of implants. Defects were filled with BMP(BMP group) and DFDB(DFDB group). For the fluoromicroscopic examination, the fluorescent dyes(oxytetracycline, calcein green, alizarin red) were injected 2, 4, 6, 8, 12 weeks after implantation. The experimental animals were sacrificed at the 6th and the 12th week and their mandible were extirpated and processed for examination with light microscopy, fluoromicroscopy and TEM. The obtained results were as follows : 1. By the light microscopic findings, the defects were filled with woven bone at the 6th week and compact bone at the 12th week, and the osseointegrations were seen in both groups. There was no histological difference between them. 2. On the basis of the histomorphometric analysis, BMP group(6th week: 40.25%, 12th week: 56.04%) had higher bony contact ratio than DFDB group(38.37%, 42.63%). There was significant difference between two groups at the 12th week(p<0.05). 3. The amount of bone formation in BMP group was more prominent than in DFDB group. Significant difference was noted among two groups at the 6th and the 8th week(p<0.05). 4. By the transmission electron microscopic findings, $0.4-2{\mu}m$ soft tissue layer was found in adjacent to the interfaces and over the collagen fibrils of bone at the 6th week. However, about 100nm amorphous layer was noted at the interface or collagen fibrils directly extended to the titanium surface at the 12th week. There was no significant difference between two groups. 5. These results suggest that BMP and DFDB can be used as good graft materials in the regeneration of bone adjacent to implant, and BMP is more valuable as a bone inducer than DFDB.

  • PDF

하악골 신장술에서 압축자극을 통한 골 재생방식에 대한 생체 역학적 평가 (BIOMECHANICAL EVALUATION ON BONE REGENERATION IN MANDIBULAR DISTRACTION OSTEOGENESIS COMBINED WITH COMPRESSION STIMULATION)

  • 허준;김욱규;황대석;김용덕;신상훈;정인교;김철훈;윤석영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권5호
    • /
    • pp.470-478
    • /
    • 2007
  • The purpose of this study was to investigate the clinical, biomechanical, and histologic changes in new distraction osteogenesis(DO) technique combined with a compression stimulation in accordance to different compression-distraction force ratio. 23 adult male rabbits underwent open-osteotomy at the mandibular body area and a external distraction device was applied. In the control group of 8 rabbits, only a 8 mm of distraction was performed by conventional DO technique. In an experimental group of 15 rabbits, a distraction followed by a compression force was performed according to the ratio of compression-distraction suggested by authors. The rate of experimental group I was set up as a 2 mm compression versus 10 mm distraction and the rate of experimental group II was set up as a 3 mm compression versus 11 mm distraction. All the rabbits were sacrificed for a gross finding, biomechanical, histomorphometric and histologic findings at the time of 55 days from the operation day. The results were as follows: 1. On the gross findings, because all rabbits had a sufficient healing time, every distracted new bone had good bone quality and we could not find any difference among all three groups. 2. In the histologic findings, rapid bone maturation(wide lamellar bone formation in the cancellous and cortical bone areas) was observed in two experimental groups compared to the control group. 3. On the bone density tests, the experimental group II showed higher bone density than the other experimental group and control group(control group-$0,2906g/cm^2$, experimental group I-$0.2961g/cm^2$, experimental group II-$0.3328g/cm^2$). 4. On the biomechanical tests, the experimental group II had significantly higher bone microhardness than the other experimental group and control group(control group-252.7 MPa, experimental group I-263.5 MPa, experimental group II-426.0 MPa). 5. On the microhardness tests, when we compared the hardness ratio of distracted bone versus normal bone, we could find experimental group II had significantly higher hardness ratio than the other experimental group and control group(control group-0.47, experimental group I-0.575, experimental group II-0.80). From this study, we could deduce that the modified distraction osteogenesis method with a compression stimulation might improve the quality of bone regeneration and shorten the consolidation period in comparison with conventional distraction osteogenesis techniques.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

다양한 골이식재료를 이용한 상악동 골이식 4개월 후 조직형태계측학적 평가 (Histomorphometric Study of Sinus Bone Graft using Various Graft Material)

  • 이지영;김영균;김수관;임성철
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.141-147
    • /
    • 2011
  • 본 연구는 상악동골이식술에 사용된 다양한 골이식재와 자가치아골이식재의 효율성을 비교하고 조직형태계측학적으로 평가하는 것이다. 2007년 10월부터 2009년 9월까지 분당서울대학교병원에서 상악동골이식술을 시행 받은 24명의 환자들을 대상으로 하였다. 환자들의 평균 나이는 $52.51{\pm}11.86$세였다. 모든 증례들은 사용된 골이식재의 종류에 따라 3그룹으로 분류되었다. 1군: 자가치아골이식재, 2군: OrthoblastII(integra lifescience corp. Irvine, US)+Biocera(Osscotec, seoul, korea), 3군: DBX(Synthes, USA)+BioOss(Geistlich Pharm AG, Wolhusen, Switzerland). 총 37개의 임프란트가 식립되었다(1군: 7, 2군: 10, 3군: 20). 신생골 형성, 직골과 층판골의 비율, 신생골과 골이식재의 비율을 조직형태계측학적으로 평가하였다. 통계처리는 SPSS Ver. 12.0을 사용하여 Kruskal-Wallis test를 시행하였다. 신생골 형성 비율은 1군 $52.5{\pm}10.7$, 2군 $52.0{\pm}23.4$, 3군 $51.0{\pm}18.3$였고 통계적으로 유의성 있는 차이는 없었다. 직골과 층판골의 비율은 1군 $82.8{\pm}15.3$, 2군 $36.7{\pm}59.3$, 3군 $31.0{\pm}51.2$였다. 신생골과 잔존골이식재의 비율은 1군 $81.3{\pm}10.4$, 2군 $72.5{\pm}28.8$, 3군 $80.3{\pm}24.0$였다. 4개월의 치유기간 후에 모든 군에서 양호한 신생골 형성이 이루어졌다. 본 연구의 제한적인 범위 내에서 자가치아골이식재는 상악동골이식에 사용될 수 있는 새로운 골이식재료라고 사료된다.