• Title/Summary/Keyword: highway investigation

Search Result 164, Processing Time 0.024 seconds

Experimental investigation of impact behaviour of shear deficient RC beam to column connection

  • Murat, Aras;Tolga, Yilmaz;Ozlem, Caliskan;Ozgur, Anil;R. Tugrul, Erdem;Turgut, Kaya
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.619-632
    • /
    • 2022
  • Reinforced concrete (RC) structures may be subjected to sudden dynamic impact loads such as explosions occurring for different reasons, the collision of masses driven by rockfall, flood, landslide, and avalanche effect structural members, the crash of vehicles to the highway and seaway structures. Many analytical, numerical, and experimental studies focused on the behavior of RC structural elements such as columns, beams, and slabs under sudden dynamic impact loads. However, there is no comprehensive study on the behavior of the RC column-beam connections under the effect of sudden dynamic impact loads. For this purpose, an experimental study was performed to investigate the behavior of RC column-beam connections under the effect of low-velocity impact loads. Sixteen RC beam-column connections with a scale of 1/3 were manufactured and tested under impact load using the drop-weight test setup. The concrete compressive strength, shear reinforcement spacing in the beam, and input impact energy applied to test specimens were taken as experimental variables. The time histories of impact load acting on test specimens, accelerations, and displacements measured from the test specimens were recorded in experiments. Besides, shear and bending crack widths were measured. The effect of experimental variables on the impact behavior of RC beam-column connections has been determined and interpreted in detail. Besides, a finite element model has been established for verification and comparison of the experimental results by using ABAQUS software. It has been demonstrated that concrete strength, shear reinforcement ratio, and impact energy significantly affect the impact behavior of RC column-beam connections.

Characteristics of Basin Topography and Rainfall Triggering Debris Flow (토석류 발생 지형과 유발 강우 특성 분석)

  • Kim, Kyung-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.263-271
    • /
    • 2008
  • Investigation and analysis of the debris flow characteristics such as basin topography, geologic conditions of initiation location and triggering rainfall are required to systematically mitigate debris flow hazard. In this paper, 48 debris flows which had caused some damages to the highway in the past 5 years are investigated and their characteristics of basic topography and triggering rainfall are analyzed. Debris flows are found to occur in small basins having the area of $0.01{\sim}0.65km^2$ range and mostly initiated by the surficial failure of natural slope having the inclination of 29~55 degree during the intense rainfall. As for the triggering rainfall, rainfall of 2 to 5 year recurrence frequency are found to be able to trigger the debris flow and magnitude of debris flow in a basin could depend on the rainfall intensity and cumulative amount.

Development of Heterogeneous Damage Cause Estimation Technology for Bridge Decks using Random Forest (랜덤포레스트를 활용한 교량 바닥판의 이종손상 원인 추정 기술 개발)

  • Jung, Hyun-Jin;Park, Ki Tae;Kim, Jae Hwan;Kwon, Tae Ho;Lee, Jong-Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.19-32
    • /
    • 2024
  • An investigation into the detailed safety diagnosis report indicates that domestic highway bridges mainly suffer from defects, deterioration, and damage due to physical forces. In particular, deterioration is an inevitable damage that occurs due to various environmental and external factors over time. In particular, bridge deck is very vulnerable to cracks, which occur along with various types of damages such as rebar corrosion and surface delamination. Thus, this study evaluates a correlation between heterogeneous damage and deterioration environment and then identifies the main causes of such heterogeneous damage. After all, a bridge heterogeneous damage prediction model was developed using random forests to determine the top five factors contributing to the occurrence of the heterogeneous damage. The results of the study would serve as a basic data for estimating bridge maintenance and budget.

Chemical Compositions of the Highway Side Fogwater in Shingal, Kyunggi-Province (경기도 신갈지역 고속도로변 안개의 화학적 조성)

  • 김홍률;주영특;정동준
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.1
    • /
    • pp.11-17
    • /
    • 2003
  • pH value of sampled fogwater at source regions (above highway and road) in Yongin sites showed the lowest value and was increased after passing the forest stands. Changes of ion concentrations through the forest stands showed a lowering tendency at sampling sites. The fogwater passing the forest stands (Quercus mangolica and Pinus rigida) surrendered acid pollutants to crown and stem from the atmosphere. It was concluded that environmental moisture in the atmosphere is acidified in fogwater. The influence was extended to the pure zone, and the frequency of acid rain has increased. The forests are assumed to remove air pollutants because ion concentrations in fogwater decreased after passing the forests. The fogwater which functions as a local sink for pollutants (H$_2$SO$_4$, HNO$_3$, etc.) falling on plant surfaces is considered to effectively remove acid pollutants. But if the deposition of pollutants exceeds the capacity of purification, it would damage the forest ecosystem. Further investigation is necessary to identify tree species tolerant to acid pollutants.

On-Land Seismic Survey of Korea (한국의 육상 탄성파탐사)

  • Kwon, Byung-Doo
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.441-450
    • /
    • 2006
  • The on-land seismic survey in Korea was begun in mid-1960s. Kim et al.(1967) of Korea Geological Survey reported on the result of gravity and seismic reflection surveys conducted in the Pohang area for the period of 1963-64 to assess its possibility of oil entrapment. Hyun and Kim (1966) carried out a refraction survey on the tunnel wall. Since then, the KGS geophysicists had conducted seismic surveys on Kyungsang sedimentary basin as a main project for several years. In 1970s, on-land seismic surveys had been conducted for various purposes such as site investigation for the nuclear power plants and industrial complex, exploration for ground water, mineral resources and underground tunnel. The first reflection survey with CMP acquisition was attempted in 1978 by using a digital recording system. But most of on-land seismic surveys had employed the refraction method until 1980s. In 1990s, high resolution reflection and various borehole seismic surveys such as tomography, uphole, downhole, cross-hole methods have been attempted by universities and engineering companies. The applications of on-land seismic surveys have been enlarged for both academic and industrial purposes such as investigation of geologic structure of the fault and tidal flat area, construction of highway, railroad and dam, geothermal energy and mineral resource exploration, environmental assessment for waste disposal sites and archaeological investigations. In 2002, the first crustal seismic survey was carried out on the profile of 294km length across the whole peninsular. It is expected that the advanced technology and experience acquired through offshore seismic surveys, which have been conducted in continental shelf of Korea and foreign oil fields, will stimulate the more active on-land seismic explorations.

Long-term Performance of Fiber Grid Reinforced Asphalt Pavements Overlaid on Old Concrete Pavements (노후 콘크리트포장 위에 덧씌운 섬유그리드 보강 아스팔트포장의 장기공용성)

  • Lee, Ju Myeong;Baek, Seung Beom;Lee, Kang Hoon;Kim, Jo Soon;Jeong, Jin Hoon
    • International Journal of Highway Engineering
    • /
    • v.19 no.3
    • /
    • pp.31-43
    • /
    • 2017
  • PURPOSES : The objective of this study is to verify the effect of fiber grid reinforcement on the long-term performance of asphalt pavement overlaid on old concrete pavement by performing field investigation, laboratory test, and finite element analysis. METHODS : The reflection cracking, roughness, and rutting of fiber grid reinforced overlay sections and ordinary overlay sections were compared. Cores were obtained from both the fiber grid reinforced and ordinary sections to measure bonding shear strength between the asphalt intermediate and asphalt overlay layers. Fracture energy, displacement after yield, shear stiffnesses of the cores were also obtained by analyzing the test results. Finite element analysis was performed using the test results to validate the effect of the fiber grid reinforcement on long-term performance of asphalt pavement overlaid on the old concrete pavement. The fatigue cracking and reflection-cracking were predicted for three cases: 1) fiber grid was not used; 2) glass fiber grid was used; 3) carbon fiber grid was used. RESULTS : The reflection-cracking ratio of fiber grid reinforced sections was much smaller than that of ordinary sections. The fiber grid reinforcement also showed reduction effect on rutting while that on roughness was not clear. The reflection-cracking was not affected by traffic volume but by slab deformation and joint movement caused by temperature variation. The bonding shear strength of the fiber grid reinforced sections was larger than that of the ordinary sections. The fracture energy, displacement after yield, and shear stiffnesses of the cores of the fiber grid reinforced sections were also larger than those of the ordinary sections. Finite element analysis results showed that fatigue cracking of glass or carbon fiber grid reinforced pavement was much smaller than that of ordinary pavement. Carbon fiber grid reinforcement showed larger effect in elongating the fatigue life of the ordinary overlay pavement compared to glass fiber grid reinforcement. The binder type of the overlay layer also affected the fatigue life. The fiber grid reinforcement resisted reflection-cracking and the carbon fiber grid showed the greater effect. CONCLUSIONS :The results of field investigation, laboratory test, and finite element analysis showed that the fiber grid reinforcement had a better effect on improving long-term performance of asphalt pavement overlaid on the old concrete pavement.

Severity Analysis of the Pedestrian Crash Patterns Based on the Ordered Logit Model (Ordered Logit Model을 이용한 보행자 사고 심각도 요인 분석)

  • Choi, Jai-Sung;Kim, Sang-Youp;Hwang, Kyung-Sung;Baik, Seung-Yup
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.153-164
    • /
    • 2009
  • This Paper presents the severity analysis result of the year 2006 national pedestrian crashes using the data base of 37,589 records prepared for the National Police Bureau. A set of attributing factors considered to affect pedestrian crash patterns were selected, and their contributing effects were investigated by applying the Ordered Logit Model. This model was selected because this model has been able to afford satisfactory results when the dependent variable involved ordered severity levels; fatal, injury, and property- damage-only in this investigation. The investigation has unveiled the followings; First, the pedestrian crash patterns were dependent upon human -drivel and pedestrian- characteristics including gender, age, and drinking conditions. Second, other contributing factors included vehicle, roadway geometric, weather, and hour of day characteristics. Third, seasonal effect was not contributive to crash patterns. Finally, the application of the Ordered Logit Model facilitated the ordered severity level analysis of the pedestrian crash data. This paper concludes that conventional wisdom on the pedestrian crash characteristics is largely truthful. However, this conclusion is limited only to the data used in this analysis, and further research is required for its generalization.

  • PDF

Effect of temperature and moisture on curling of early age concrete slabs (재령 초기 콘크리트 슬래브의 컬링에 미치는 온도와 수분의 영향)

  • Sun, Ren-Juan;Nam, Young-Kug;Hong, Seung-Ho;Jeong, Jin-Hoon
    • International Journal of Highway Engineering
    • /
    • v.10 no.1
    • /
    • pp.105-115
    • /
    • 2008
  • It is known that the long-term behavior and performance of jointed concrete pavement due to slab curling are affected by the environmental factors such as temperature, moisture, and so on. However, any relationships between the curling and its factors have not been defined clearly yet because of insufficient detailed investigation. The temperature, relative humidity, strain, vertical displacement of a concrete slab, and horizontal movement of its transverse joints were investigated by various sensors and devices instrumented in the slab of a concrete pavement section constructed for this study. The constraint of the curling by joint stiffness was investigated in addition to effect of the temperature and moisture on the early aged concrete slab by analyzing the field data measured for approximately 4days from concrete placement. The curling of the concrete slab showed 24hour cycles mainly because of the temperature effect, and the upward curling gradually increased because of the long-term effect of drying shrinkage of the concrete. The magnitude and variation of the curling were significantly affected by the joint stiffness which is comprised of aggregate interlocking and other factors. The effect of the variation of the seasonal joint stiffness varying with the temperature and long-term drying shrinkage on the slab curling will be investigated as a further study.

  • PDF

A Study on Development & Establishment of Performance Evaluation Criteria for Guardrail End Treatments (노측 가드레일용 단부처리시설 성능평가기준 정립 및 개발)

  • Joo, Jae-Woong;Kum, Ki-Jung;Park, Je-Jin;Jang, Dae-Young
    • International Journal of Highway Engineering
    • /
    • v.10 no.1
    • /
    • pp.123-134
    • /
    • 2008
  • Since the end treatments of guardrails installed on domestic roads have the shapes which can easily penetrate and turnover a vehicle, the occupant can be subjected to severe injury when a vehicle impacts the end treatments. In this study, the criteria of performance evaluation for end treatments are suggested which are suitable to domestic road circumstances. Based on the investigation for the installation and studies instances of end treatments, the mechanism of end treatments is examined and the new end treatment suitable to domestic road circumstances is suggested. The suggested end treatment was verified by computer simulation using d LS-DYNA programs and satisfied the suggested performance evaluation criteria for end treatments. And the developed end treatment was verified by full-scale vehicle crash test and satisfied the following three primary appraisal factors of the suggested performance evaluation criteria for end treatments; occupant risk criteria, structural adequacy, and after-collision vehicle trajectory. This study is the first to develop end treatments considering the occupant safety in Korea. Therefore, If the developed end treatments is installed on roads and highways, it can be expected that it will reduce the grave situation of end treatment accidents and increase the safety of roads.

  • PDF

Characteristics of Collected Sediments from Road Sweeping and Reduction in the Nonpoint Source Pollutants Loading (도로청소 수거퇴적물의 특성과 비점오염물질 저감효과)

  • Jeong, Kwon;Kang, Hee-Man;Ko, Seok-Oh
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • The stormwater runoff from road or expressway is known as one of important nonpoint pollution sources. To reduce the pollutants discharge from road or expressway, many best management practices(BMPs) have been applied and planned. Among the BMPs, road sweeping can be effective way to prevent pollutant washoff to environment. This study is performed to evaluate the characteristics of particles collected from the road by sweeping car. Size distribution and pollutant concentration of particles were analyzed. Based on the pollutant concentration and the specification of road such as length, width, and unit for pollutant generation, total amount of pollutant to be removed by road sweeping was estimated. Most of sediments collected by road sweeping was classified into sandy soil and fraction of fine grained soil was low. Although the concentrations of pollutants such as heavy metals in road sediments did not exceed the soil contamination criteria, washout of pollutants during sweeping work by spraying water might cause leaching of pollutants contained in sediments and thus resulted in low pollutant concentrations. Reduced amounts of pollutant by road sweeping showed 31.4% TSS reduction for ${\bigcirc}{\bigcirc}$ region and 7.7% TSS for ${\triangle}{\triangle}$ region. Other pollutants showed low reduction rate, because of their leaching by water spraying. Results from this study indicate that detailed and well-planned investigation for the road sweeping is necessary for the accurate estimation of pollutant reduction from road or expressway.