• Title/Summary/Keyword: high-temperature-short-time treatment

Search Result 72, Processing Time 0.032 seconds

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF

Experimental Study on the Physical and Mechanical Properties of a Copper Alloy for Liquid Rocket Combustion Chamber Application (액체로켓 연소기용 구리합금의 열/기계적 특성에 관한 실험적 연구)

  • Ryu, Chul-Sung;Baek, Un-Bong;Choi, Hwan-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.11 s.254
    • /
    • pp.1494-1501
    • /
    • 2006
  • Mechanical and physical properties of a copper alloy for a liquid rocket engine(LRE) combustion chamber liner application were tested at various temperatures. All test specimens were heat treated with the condition they might experience during actual fabrication process of the LRE combustion chamber. Physical properties measured include thermal conductivity, specific heat and thermal expansion data. Uniaxial tension tests were preformed to get mechanical properties at several temperatures ranging from room temperature to 600$^{\circ}C$. The result demonstrated that yield stress and ultimate tensile stress of the copper alloy decreases considerably and strain hardening increases as the result of the heat treatment. Since the LRE combustion chamber operates at higher temperature over 400$^{\circ}C$, the copper alloy can exhibit time-dependent behavior. Strain rate, creep and stress relaxation tests were performed to check the time-dependent behavior of the copper alloy. Strain rate tests revealed that strain rate effect is negligible up to 400$^{\circ}C$ while stress-strain curve is changed at 500$^{\circ}C$ as the strain rate is changed. Creep tests were conducted at 250$^{\circ}C$ and 500$^{\circ}C$ and the secondary creep rate was found to be very small at both temperatures implying that creep effect is negligible for the combustion chamber liner because its operating time is quite short.

A Study on the Borided Stsucture of Cast Iron (주철(鑄鐵)의 침붕조직(浸硼組織)에 관(關)한 연구(硏究))

  • Kim, H.S.;Ra, H.Y.
    • Journal of Korea Foundry Society
    • /
    • v.2 no.3
    • /
    • pp.2-15
    • /
    • 1982
  • In this study, the influenced of graphite shape on the boriding of cast iron and boride structure was investigated. Gray cast iron, ferritic and pearlitic ductile cast iron were borided at 750,850,900 and $950^{\circ}C$ for 1,3 and 5 hours by powder pack method with the mixture of $B_4C_9\;Na_2B_4O_7$, $KBF_4$ and Shc. The boride layer was consisted of FeB(little), $Fe_2B$ (main) and graphite. Some possibility of the existence of unknown Fe-B-C compound in the boride layer was suggested. And precipitates in the diffusion zone was $Fe_3(B,C)$. The concentration of Si and precipitation of $Fe_3(B,C)$ in the ${\alpha}$ layer raised the hardness of this Zone. The depth and hardness of boride layer increased with the increase of treating temperature and tim. But high temperature (over $950^{\circ}C)$ caused pore at graphite position and long treating time (5hrs) sometimes caused formation of graphite layer beneath the boride layer. So, for the practical application of borided cast iron, treating in short time and at low temperature was recommended. And for ductile cast iron, ferritizing or pearlitizing heat treatment was seemmed to be possible at the same time with boriding. The graphite in the boride layer was deeply concerned with the qualitx and characteristics of the boride layer. And it greatly influenced on the shape of the boride phase, structure of the boride layer. Generally speaking, the existance of graphite restrained the growth of the boride phase. But the boundary between the gsaphite and the matrix acted as the shortcut of boron diffusion. So, for gray cast iron, the graphite layed length-wise led the formation of boride layer.

  • PDF

Operational Characteristics of the Anaerobic Sequencing Batch Reactor Process at a Thermophilic Temperature (연속 회분식 고온 혐기성 공정의 운전특성 연구)

  • Lee, Jong Hoon;Chung, Tai Hak;Chang, Duk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1997
  • An attempt was made to enhance anaerobic treatment efficiency by adopting the anaerobic sequencing batch reactor(ASBR) process at a thermophilic temperature. Operational characteristics of the ASBR process were studied using laboratory scale reactors and concentrated organic wastewater composed of soluble starch and essential nutrients. Effects of fill to react ratio (F/R) were examined in the Phase I experiment, where the equivalent hydraulic retention time(HRT) was maintained at 5 days with the influent COD of 10g/L. A continuous stirred tank reactor(CSTR) was operated in parallel as a reference. Treatment efficiency was higher for the ASBRs because of continuous accumulation of volatile suspended solids(VSS) compared to the CSTR. However, the rate of gas production and organic removal per unit VSS in the ASBRs was much lower than the CSTR. This was caused by reduced methane fermentation due to accumulation of volatile acids(VA), especially for the case of low F/R, during the fill period. When the F/R was high, maximum VA was low and the VA decreased in short period. Consequently, more stable operation was possible with higher F/R. Effects of hydraulic loading rate on the efficiency was studied in the Phase II experiment, where the organic loading rate was elevated to 3333mg/L-d with the F/R of 0.12. Reduction of organic removal along with rapid increase of VA was observed and the stability of reaction was seriously impaired, when the influent COD was doubled. However, operation of the ASBR was quite stable, when the hydraulic loading rate was doubled and a cycle time was adjusted to 12 hour. It is essential to avoid rapid accumulation of VA during the fill period in order to maintain operational stability of the ASBR.

  • PDF

Removal and Regrowth Inhibition of Microcystis aeruginosa using Artemisia asiatica Extracts (쑥 추출액을 이용한 Microcystis aeruginosa 제거 및 성장억제 연구)

  • Choi, Hee-Jeong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.441-448
    • /
    • 2017
  • Microcystis aeruginosa (M. aeruginosa) is a cyanobacterium species that can form harmful algal blooms in freshwater bodies worldwide. The use of Artemisia asiatica extracts to control M. aeruginosa inhibition will be environmentally friendly and promising. Artemisia asiatica extracts removed successfully upto 88% of M. aeruginosa pH 8 at $25^{\circ}C$ of temperature. These results was indicated that the amount of 2.24 g/L Artemisia asiatica extracts was removed 1g dryweight/L of M. aeruginosa. The kinetic data showed substrate inhibition kinetics and maximum growth rate was obtained when the M. aeruginosa was grown in medium containing 2.5 g/L of initial concentration of Artemisia asiatica extracts. In the various growth control models, Luong model showed the highest correlation coefficient of 0.9916. Therefore, the Luong model was the most suitable control model for the growth control of M. aruginosa using Artemisia asiatica extracts. In conclusion, the growth control of M. aruginosa using Artemisia asiatica extracts can be applied in the field without controlling the temperature and pH of rivers and streams, and it is possible to control the growth of M. aruginosa efficiently in a short time. The natural extract, Artemisia asiatica extracts, can be a promising inhibition due to its high efficiency and low dose requirements.

Development of Wireless Healthcare System for Emergency Treatment (응급상황을 대비한 무선의료관리시스템 개발)

  • Park, Sung-Chul;Moon, Byung-Hyun;Lim, Byung-Hyun;Hwang, Bum-Suk;Choi, Sang-Min
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.125-130
    • /
    • 2009
  • Today, the handicapped or old people require continuous care, but there are a lot of practical difficulties. In this paper, the system measuring health conditions of the handicapped or old people (pulse and temperature) is developed. If urgent health conditions occur, measurement values are delivered to doctors or close family members using SMS (Short Message Service) of cellular phone. In the developed system, Pulse rate is measured by sensing bloodstream using high luminance LED and CdS illumination sensors. Body temperature is also measured by contactless temperature sensor. Also, the measured values are transmitted to a server computer using Zigbee communications. Also, the measured values the average of measurements and the time are saved. The wireless healthcare system is designed to help the emergency for the handicapped and old people by using SMS.

Development of a HVHC-PEF Power Supply for Low Temperature Pasteurization (저온 살균용 펄스형 고압 대전류 전원장치 개발)

  • Yoo, D.W.;Kim, H.S.;Baek, J.W.;Ryoo, H.J.;Rim, G.H.;Pavlov, E.P.;Park, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2162-2164
    • /
    • 1997
  • High Voltage High Current Pulsed Electric Fields (HVHC-PEF) is a promising technology for the non-thermal pasteurization of foods and a sound complement or replacement to traditional thermal pasteurization, which inactivates bacteria and other microorganisms harmful to humans, but also degrades color, flavor, texture and nutrients. Foods can be pasteurized with pulsed electric fields at ambient or refrigerated temperatures for a short treatment time of seconds or less and the fresh-like quality of food is preserved. Although successful in laboratory tests, applying HVHC-PEF to food pasteurization on a large scale presents many unresolved engineering problems. In this paper the design considerations for 25kV 1kA class HVHC-PEF pasteurization equipment are analyzed and experimental results are discussed.

  • PDF

Evaluation and Comparison with Standard 48 hr Acute Bioassay and High Temperature Rapid Toxicity Test for Sewage Toxicity Test (하수의 독성평가를 위한 표준독성시험법과 온도증가 단기독성평가법의 비교 평가)

  • Lee, Sang-Ill;Jun, Byong-Hee;Weon, Seung-Yeon;Kim, Yi-Jung;Kim, Keum-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • A new method, ToxTemp (TOXcity test based on TEMPerature control) using Ceridaphnia dubia was applied to evaluate the toxicity of insecticide materials and compared with the standard 48 hr acute bioassay. BPMC, diazinon and fenitrothion may cause the inhibition to the biological process in sewage treatment plant and need to detect toxicity within short contact time. The ToxTemp method showed sensitive detection with more shorter contact of 1-1.5 hr time than that of the standard 48 hr acute bioassay. To evaluate toxicity of real wastewater/sewage, the inhibition rate of nitrification and oxygen uptake rate (OUR) using activated sludge, the standard 48hr acute bioassay and ToxTemp method using C. dubia were compared, respectively. On the basis of the inhibition rate of nitrification, the OUR test showed the less sensitive results at the relatively strong toxic sewage. On the other hands, the standard 48hr acute bioassay and ToxTemp method using C. dubia represented the toxicity of each wastewater/sewage with high sensitivity. Even the slightly low (about 1.5%) sensitivity, the ToxTemp method showed the high applicability to the real site of sewage treatment plant.

Glass strengthening and coloring using PIIID technology

  • Han, Seung-Hee;An, Se-Hoon;Lee, Geun-Hyuk;Jang, Seong-Woo;Whang, Se-Hoon;Yoon, Jung-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.178-178
    • /
    • 2016
  • Every display is equipped with a cover glass to protect the underneath displaying devices from mechanical and environmental impact during its use. The strengthened glass such as Gorilla glass.$^{TM}$ has been exclusively adopted as a cover glass in many displays. Conventionally, the strengthened glass has been manufactured via ion-exchange process in wet salt bath at high temperature of around $500^{\circ}C$ for hours of treatment time. During ion-exchange process, Na ions with smaller diameter are substituted with larger-diameter K ions, resulting in high compressive stress in near-surface region and making the treated glass very resistant to scratch or impact during its use. In this study, PIIID (plasma immersion ion implantation and deposition) technique was used to implant metal ions into the glass surface for strengthening. In addition, due to the plasmonic effect of the implanted metal ions, the metal-ion implanted glass samples got colored. To implant metal ions, plasma immersion ion implantation technique combined with HiPIMS method was adopted. The HiPIMS pulse voltage of up to 1.4 kV was applied to the 3" magnetron sputtering targets (Cu, Ag, Au, Al). At the same time, the sample stage with glass samples was synchronously pulse-biased via -50 kV high voltage pulse modulator. The frequency and pulse width of 100 Hz and 15 usec, respectively, were used during metal ion implantation. In addition, nitrogen ions were implanted to study the strengthening effect of gas ion implantation. The mechanical and optical properties of implanted glass samples were investigated using micro-hardness tester and UV-Vis spectrometer. The implanted ion distribution and the chemical states along depth was studied with XPS (X-ray photo-electron spectroscopy). A cross-sectional TEM study was also conducted to investigate the nature of implanted metal ions. The ion-implanted glass samples showed increased hardness of ~1.5 times at short implantation times. However, with increasing the implantation time, the surface hardness was decreased due to the accumulation of implantation damage.

  • PDF

Synthesis of Iodine Substituted Polycarbosilane by High Temperature and Pressure Reaction Process and Properties Characterization (고온, 고압에서의 요오드 치환 Polycarbosilane의 합성 및 특성)

  • Byen, Ji Cheol;Sharbidre, Rakesh Sadanand;Kim, Yoon Ho;Park, Seung Min;Ko, Myeong Seok;Min, Hyo Jin;Lee, Na young;Ryu, Jae-Kyung;Kim, Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.30 no.9
    • /
    • pp.489-494
    • /
    • 2020
  • SiC is a material with excellent strength, heat resistance, and corrosion resistance. It is generally used as a material for SiC invertors, semiconductor susceptors, edge rings, MOCVD susceptors, and mechanical bearings. Recently, SiC single crystals for LED are expected to be a new market application. In addition, SiC is also used as a heating element applied directly to electrical energy. Research in this study has focused on the manufacture of heating elements that can raise the temperature in a short time by irradiating SiC-I2 with microwaves with polarization difference, instead of applying electric energy directly to increase the convenience and efficiency. In this experiment, Polydimethylsilane (PDMS) with 1,2 wt% of iodine is synthesized under high temperature and pressure using an autoclave. The synthesized Polycarbosilane (PCS) is heat treated in an argon gas atmosphere after curing process. The experimental results obtain resonance peaks using FT-IR and UV-Visible, and the crystal structure is measured by XRD. Also, the heat-generating characteristics are determined in the frequency band of 2.45 GHz after heat treatment in an air atmosphere furnace.