• 제목/요약/키워드: high-temperature area

검색결과 2,582건 처리시간 0.037초

High Temperature Deformation Behavior of Al-Zn-Mg-Based New Alloy Using a Dynamic Material Model

  • Jang, Bong Jung;Park, Hyun Soon;Kim, Mok-Soon
    • Metals and materials international
    • /
    • 제24권6호
    • /
    • pp.1249-1255
    • /
    • 2018
  • High temperature compression tests for newly developed Al-Zn-Mg alloy were carried out to investigate its hot deformation behavior and obtain deformation processing maps. In the compression tests, cylindrical specimens were deformed at high temperatures ($300-500^{\circ}C$) and strain rates of 0.001-1/s. Using the true stress-true strain curves obtained from the compression tests, processing maps were constructed by evaluating the power dissipation efficiency map and flow instability map. The processing map can be divided into three areas according to the microstructures of the deformed specimens: instability area with flow localization, instability area with mixed grains, and stable area with homogeneous grains resulting from continuous dynamic recrystallization (CDRX). The results suggest that the optimal processing conditions for the Al-Zn-Mg alloy are $450^{\circ}C$ and a strain rate of 0.001/s, having a stable area with homogeneous grains resulting from CDRX.

Landsat 위성영상을 활용한 재건축 지역의 지표 온도 변화에 관한 연구 : 서울특별시 강동구의 고덕동과 둔촌동을 중심으로 (A Study on Land Surface Temperature Changes in Redevelopment Area Using Landsat Satellite Images : Focusing on Godeok-dong and Dunchon-dong in Gangdong-gu, Seoul)

  • 한지훈;손철
    • 한국지리정보학회지
    • /
    • 제26권2호
    • /
    • pp.42-54
    • /
    • 2023
  • 우리나라 대도시 지역에 인구가 집중되고 이에 따른 수요를 충족시키기 위하여 저밀도 주거지가 재개발·재건축을 통하여 고밀도 주거지화 되고 있다. 그러나 단시간에 이루어진 대규모의 재건축은 도시녹지 면적 감소에 의한 열섬현상을 발생시키는 등 도시 기후에 부정적인 영향을 끼치게 된다. 본 연구에서는 Landsat 8 위성영상을 활용하여 서울특별시 강동구 고덕동, 둔촌동 재건축 지역의 2013년에서 2022년까지의 지표 온도의 변화를 분석하였다. 고덕동 지역에서는 재건축이 진행되는 대상지와 산림지역, 산림과 시가지가 혼재된 지역, 저층주거지역에 대한 지표 온도의 차이를 분석하였으며, 둔촌동 지역에서는 대상지와 산림지역, 저층주거지역에 대한 지표 온도의 차이를 분석하였다. 분석은 지표 온도 차이에 대한 다중회귀분석을 통하여 진행되었다. 고덕동 지역과 둔촌동 지역에서 공통적으로 재건축 전단계까지 전반적으로 지표 온도가 산림보다 높고 저층주거지역보다 낮게 나타났다. 이러한 특징들은 고덕동, 둔촌동의 저층주거지역이 대상지보다 녹지율이 낮고 건폐율이 높기 때문에 발생하였음을 알 수 있다. 본 연구를 통해 저밀도 지역이 고밀도화가 되더라도 녹지와 건폐율을 적절하게 관리한다면 도시열섬현상을 완화시킬 수 있음을 알 수 있다.

공동주택 건축물 층수완화에 따른 열환경 평가에 관한 연구 (A Study on Evaluation of Thermal Environment Following the Alleviation of the Limit on Number of Floors of Apartment Complexes)

  • 류지원;정응호;아키라 호야노
    • 한국주거학회논문집
    • /
    • 제22권3호
    • /
    • pp.93-100
    • /
    • 2011
  • The objective of this study is to provide basic objective data which can be utilized as an adjustment criterion for the alleviation of the limit on the number of floors of buildings by quantitatively evaluates the effect of the alleviation of the limit on the number of floors of buildings in apartment complexes on thermal environment of apartment complexes using data obtained from apartments in a class 2 general residential area. In this study, we carried out a thermal environment analysis utilizing the simulation of a virtual object area. The result is summarized as follows: The result of analyzing the entire surface temperature showed an equal decrease of surface temperature due to shadow in all scenarios and high floors showed a tendency of low surface temperature during daytime as the rate of shadow the high floors increase. This influences not only the surface temperature but also HIP and is judged to greatly contribute to the alleviation of the heat island effect. Also, the reason why HIP at high floors shows high values before sunrise and after sunset is thought to be because the concrete wall of the building maintains a high temperature during nighttime by absorbing and storing sunlight during daytime instead of reflecting it since it has low reflectance.

Review of the Conceptual Design for the Use of HTS Power Transmission Cable for a Metropolitan Area

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.63-69
    • /
    • 2003
  • The necessity of compact high temperature superconducting cables is more keenly felt in densely populated metropolitan areas. Because the compact high-temperature superconducting cables can be installed in ducts and tunnels, thereby reducing construction costs and making the use of underground space more effective, the effect of introducing it to the power system will be huge. Seoul, Korea, is selected as a review model for this paper. The loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following elements for an urban transmission system are examined. (1) A method of constructing a model system to introduce high-temperature superconducting cables to metropolitan areas is presented. (2) A case study is conducted through the analysis of power demand scenarios, and the amount of high-temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high-temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared., and standards for current cable ducts are calculated. (4) The voltage level that can be accommodated by existing ducts is examined.

남극 하계 스코티아해의 총 이산화탄소, 영양염, 엽록소 분포 (Distribution of Total CO2, Nutrients, Chlorophyll-a in the Scotia Sea During Austral Summer)

  • 김동선;심정희;김경태;강영철
    • Ocean and Polar Research
    • /
    • 제26권3호
    • /
    • pp.401-414
    • /
    • 2004
  • Temperature, salinity, alkalinity, pH, nutrient, chlorophyll, and iron were measured within the upper 250m water column around the Antarctic Polar Front in the Scotia Sea from late November to early December 2001. Temperature and salinity showed a rapid change across the Polar Front, and the temperature minimum layer existed only in the southern area of the Polar Front. Total $CO_2$ and nutrient concentrations were relatively high and increased rapidly with water depth in the southern area of the Polar Front, which was resulted from upwelling of the Antarctic deep water containing high concentrations of total $CO_2$ and nutrient. ${\Delta}C:{\Delta}N:{\Delat}P$ ratios measured in the norhem and southern areas of the Polar Front were 75:11.4:1 and 84:12.5:1, respectively, which were lower than the Redfield ratio. ${\Delta}Si:{\Delta}N$ ratio (3.65) measured in the southern area of the Polar Front was two times higher than that (1.95) in the northern area. These two ratios were higher than the ratio (1.0) measured in the temperate and tropical oceans. Chlorophyll concentrations were extremely high in the area of $59^{\circ}{\sim}60^{\circ}S$, which was attributed to favorable environmental conditions for phytoplankton growth in this area, such as sufficient iron, high water column stability, and high silicate concentration.

WRF-UCM을 이용한 연안산업도시지역 고해상도 기상 모델링 (High-resolution Meteorological Simulation Using WRF-UCM over a Coastal Industrial Urban Area)

  • 방진희;황미경;김양호;이지호;오인보
    • 한국환경과학회지
    • /
    • 제29권1호
    • /
    • pp.45-54
    • /
    • 2020
  • High-resolution meteorological simulations were conducted using a Weather Research and Forecasting (WRF) model with an Urban Canopy Model (UCM) in the Ulsan Metropolitan Region (UMR) where large-scale industrial facilities are located on the coast. We improved the land cover input data for the WRF-UCM by reclassifying the default urban category into four detailed areas (low and high-density residential areas, commercial areas, and industrial areas) using subdivided data (class 3) of the Environmental and Geographical Information System (EGIS). The urban area accounted for about 12% of the total UMR and the largest proportion (47.4%) was in the industrial area. Results from the WRF-UCM simulation in a summer episode with high temperatures showed that the modeled temperatures agreed greatly with the observations. Comparison with a standard WRF simulation (WRF-BASE) indicated that the temporal and spatial variations in surface air temperature in the UMR were properly captured. Specifically, the WRF-UCM reproduced daily maximum and nighttime variations in air temperature very well, indicating that our model can improve the accuracy of temperature simulation for a summer heatwave. However, the WRF-UCM somewhat overestimated wind speed in the UMR largely due to an increased air temperature gradient between land and sea.

Potassium Rate and Mowing Height for Kentucky Bluegrass Growth

  • Lee, Sang-Kook
    • Weed & Turfgrass Science
    • /
    • 제5권4호
    • /
    • pp.268-273
    • /
    • 2016
  • Potassium is well-known to improve turfgrass tolerance to environmental stresses such as low temperature and drought stress. Low mowing height reduces leaf area of turfgrass that is main place for photosynthesis and carbohydrate production. Closely-mowed turf would suffer from summer decline by low level of carbohydrate resulted from low photosynthesis of reduced leaf area. The objective of the study is to investigate K rate and mowing height for Kentucky bluegrass. The K rate treatments were 5, 10, and $20g\;K_2O\;m^{-2}$ for the low, medium and high K rates, respectively. The bi-weekly mowing treatment was made for treatments. Mowing was implemented at 40 and 100 mm using a rotary mower. Regardless K rates, the high mowing height would be required when the air temperature is higher than $28.5^{\circ}C$ and high turfgrass quality of Kentucky bluegrass is needed. When the air temperature is optimal for cool-season grass, the high mowing height and the low K rate is needed for the root length of Kentucky bluegrass.

부산 연안역의 야간 고농도 오존 발생 특성과 기상학적 관련성 (Characteristics of nocturnal maximum ozone and meteorological relevance in Pusan coastal area)

  • 전병일
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.287-292
    • /
    • 1999
  • This study was performed to investigate the characteristics of nocturnal maxiumu ozone occurrence and the meteorological relevance using to hourly ozone data and meteorological data for 1995~1996 in Pusan coastal area. Kwangbokdong showed the highest occurrence of nocturnal maximum ozone as 36.9%, and Deokcheondong showed the lowest occurrence(9.2%) for research period in Pusan. The occurrence rates of nocturnal maximum ozone concentration were decreased toward land area. The low maximum temperature, high minimum temperature, low diurnal range, high relative humidity, high wind speed, high could amount, low sunshine and low radiation were closely related to the main meteorological characteristics occuring the nocturnal maximum concnetration of ozone. It was shown that normal daily variation of ozone concentration by strong photochemical reaction at the before day of nocturnal maximum ozone. The concnetration of nocturnal maximum ozone were occured by entrainment of ozone from the upper layer of developed mixing layer. There are no ozone sources near the ground at night, so that the nighttime ozone should be entrained from the upper layer by forced convection.

  • PDF

수도권지역 대기질 예측을 위한 기상장 모델의 바람장과 온도장 비교 연구 (Intercomparison of Wind and Air Temperature Fields of Meteorological Model for Forecasting Air Quality in Seoul Metropolitan Area)

  • 정주희;김유근;문윤섭;황미경
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.640-652
    • /
    • 2007
  • The MM5, RAMS and WRF, meteorological models have provided the dynamical parameters as inputs to air quality model. A major content of this study is that significant characteristics of three models for high-ozone occurrence analyze for surface wind and air temperature fields and compare with observation data in Seoul metropolitan area. An analysis of air temperature field revealed that location of core in high temperature of MM5 and WRF differed from that of RAMS. MM5 and WRF indicated high temperature in Seoul but RAMS represented it on the outskirts of Seoul. MM5 and WRF were underestimated maximum temperature during daytime but RAMS simulated similar value with observation data. Surface wind field with three models, it was shown many differences at horizontal distribution of wind direction. RAMS indicated weak wind speed in land and strong sea breeze at coastal areas than MM5 and WRF. However wind speed simulated by three model were overestimated during both daytime and nighttime.

고온에서 총격을 받는 CFRP 적층재의 총격손상과 잔류강도에 관한 연구 (A study on the Impact damages and residual strength of CFRP laminates to impact under high temperature)

  • 정종안;이상호;양인영
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.44-52
    • /
    • 1996
  • An experimental study on the effects of temperature change on the impact damages of CFRP aminates was made through an observation of the interrelations between the Impact energy vs. delamination area, the impact energy vs. residual bending strength, and the delamination area vs. the decreasing of the residual bending strength for CF/EPOXY and CF/PEEK composite laminates subjected to FOD (Foreign Object Damage) under high temperatures.

  • PDF