• 제목/요약/키워드: high-strength steel plate

검색결과 328건 처리시간 0.026초

선급 극후물재의 취성균열 전파 정지 인성에 미치는 용접변수의 영향 (Effect of welding variables on the crack arrest toughness of thick steel plate)

  • 류강묵;안규백;김태수;이태영;이종섭
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.103-103
    • /
    • 2009
  • As the size of containership increased over 14,000TEU, thick steel plate with high strength has been used. The plate thickness increased over 70mm and yield strength of the steel plate was around $47kg_f/mm^2$. Many researchers reported that the thick welded plate has low crack arrest toughness. They noticed the crack arrest ability is dependent on the plate thickness. In other words, brittle crack propagates straightly along the welded line and make abrupt fracture in the thick plate which causes low $K_{ca}$. In this study, the other factors, especially welding heat input, to cause low crack arrest toughness was investigated for thick steel plate welds. EH grade steel plates were used in this study and 50 to 80 thick plates were tested to confirm thickness sensitivity. Electro gas welding (EGW) and flux cored arc welding (FCAW) were adopted to prepare the welded joints. Temperature gradient ESSO test was performed to measure $K_{ca}$ values with the variation of welding variables. As a result of this study, regardless of plate thickness, welding heat input to cause welding residual stress around crack path is a key factor to control the brittle crack propagation in welded joints.

  • PDF

횡방향 판재에 의한 횡구속 효과 및 철근콘크리트 기둥에서 고강도 철근의 사용성 검토 (Confinement Effect by Plate Type Lateral Reinforcement and Investigation of the Possibility for Use of High Strength Steel Bars in Reinforced Concrete Columns)

  • 조영재;김진근
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.643-650
    • /
    • 2012
  • 콘크리트구조설계기준에서는 철근콘크리트 기둥에서 주철근의 설계기준항복강도를 550 MPa 이하로 규정하고 있다. 이는 철근콘크리트 기둥에 주철근으로 고강도 철근(high-strength concrete)을 사용할 때 콘크리트가 압축강도에 도달하여도 주철근이 항복변형률에 도달하지 않아 고강도 철근을 효율적으로 사용할 수 없기 때문이다. 철근의 설계기준항복강도 제한의 문제점을 해결하기 위한 방법으로는 횡구속력(confinement effect)을 가해주는 방법과 콘크리트의 파괴변형률(peak strain)을 증진시켜주는 방법이 있다. 횡구속을 효과적으로 가하는 방법으로서 원형 단면의 철근보다는 판재를 사용하는 것이 바람직하다. 이 연구에서는 가공이 용이한 판재로서 탄소섬유판을 철근콘크리트 기둥에서 횡구속효과를 위한 구조재료로 사용하였을 경우 보강되지 않은 경우보다 증진된 압축강도 및 축압축 파괴변형률을 보였으며, 콘크리트 단면 형상이 원형에 가까울수록, 횡구속 형태가 원형에 가까울수록 횡구속 효과는 더욱 커졌다. 최종적으로 실험 결과를 토대로 철근콘크리트 기둥에서 탄소섬유판에 의한 횡구속 효과와 함께 고강도 철근의 적용 가능성을 확인하였다.

A Study on the Ultimate Strength Behaviour of Stiffened Plate according to the Stiffener Section

  • Ko Jae-Yogn;Park Joo-Shin;Park Sung-Hyeon
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2004년도 춘계학술발표회
    • /
    • pp.113-119
    • /
    • 2004
  • A steel plated is typically composed of plate panels. The overall failure of the structure is certainly affected and can be governed by the bulking and plastic collapse of these individual members In the ultimate limit state design. therefore. a primary task is to accurately calculate the budding and plastic collapse strength of such structural members. Structural elements making up steel palated structures do not work separately. resulting in high degree of redundancy and complexity in contrast to those of steel framed structures. To enable the behavior of such structures to be analyzed, simplifications or idealizations must essentially be made considering the accuracy need and degree of complexity of the analysis to be used Generally the more complex the analysis the greater is the accuracy that may be obtained. The aim of this study is the investigation of the effect of the tripping behaviour including section characteristic for a plate under uniaxial compression.

  • PDF

Behavior of simple precast high-strength concrete beams connected in the maximum bending moment zone using steel extended endplate connections

  • Magdy I. Salama;Jong Wan Hu;Ahmed Almaadawy;Ahmed Hamoda;Basem O. Rageh;Galal Elsamak
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.627-641
    • /
    • 2024
  • This paper presents an experimental and numerical study to investigate the behavior of the precast segmental concrete beams (PSCBs) utilizing high-strength concrete (HSC) connected in the zone of the maximum bending moment using steel extended endplate connections (EECs). The experimental study consisted of five beams as follows: The first beam was the control beam for comparison, which was an unconnected one-piece beam made of HSC. The other four other beams consisted of two identical pieces of precast concrete. An important point to be noted is that at the end of each piece, a steel plate was used with a thickness of 10 mm. Moreover, this steel plate was welded to the lower and upper reinforcing bars of the beam. Furthermore, the steel plate was made to connect the two pieces using the technique of EECs. Several variables were taken in these four beams, whether from the shape of the connection or enhancing the behavior of the connection using the post-tensioning technique. EECs without stiffeners were used for some of the tested beams. The behavior of these connections was improved using stiffeners and shear bolts. To get accurate results, a comparison was made between the behaviors of the five beams. Another important point to be noted is that Abaqus and SAP2000 programs were used to investigate the behavior of PSCBs and to ensure the accuracy of the modeling process which showed a good agreement with the experimental results. Additionally, the simplified modeling using SAP2000 was able to model the nonlinear behavior of PSCBs connected using steel EECs. It was found that the steel pre-tensioned bolted EECs, reinforced with steel stiffeners and shear anchors, could be used to connect the precast HSC segmental beams via the internal pre-stressing technique.

고성능 강재(HSB 800)를 적용한 플레이트 거더의 휨강도에 대한 플랜지 국부좌굴 (Flange Local Buckling(FLB) for Flexural Strength of Plate Girders with High Performance Steel(HSB 800))

  • 김정훈;김경열;이정화;김경식;강영종
    • 한국강구조학회 논문집
    • /
    • 제26권2호
    • /
    • pp.91-103
    • /
    • 2014
  • 최근에 인장강도 800MPa급 고성능 강재가 개발되었지만 플랜지와 복부판의 상호작용을 고려한 플레이트 거더의 국부좌굴에 대한 연구는 아직까지 미흡한 실정이다. 본 연구는 HSB 800을 적용한 플레이트 거더의 플랜지 국부좌굴에 대한 강도를 비선형 유한요소해석으로 평가하였다. 비선형 해석 시 I-단면을 갖는 플레이트 거더의 플랜지와 복부판은 3차원 쉘요소로써 초기결함 및 잔류응력을 고려하였으며, 고성능 강재의 재료모델은 다중선형 재료로 모형화하였다. 이를 적용하여 복부판이 조밀, 비조밀 그리고 세장 단면을 갖는 압축 플랜지에 대해 매개변수 해석을 수행하였다. 플레이트 거더의 플랜지 국부좌굴에 대한 거동을 분석하였고, 본 연구의 비선형 해석 결과를 AASHTO LRFD(2012)와 도로교설계기준(한계상태설계법, 2012)의 압축플랜지 공칭휨강도와 비교하여 평가하였다.

Research on anti-seismic property of new end plate bolt connections - Wave web girder-column joint

  • Jiang, Haotian;Li, Qingning;Yan, Lei;Han, Chun;Lu, Wei;Jiang, Weishan
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.45-61
    • /
    • 2016
  • The domestic and foreign scholars conducted many studies on mechanical properties of wave web steel beam and high-strength spiral stirrups confined concrete columns. Based on the previous research work, studies were conducted on the anti-seismic property of the end plate bolt connected wave web steel beam and high-strength spiral stirrups confined concrete column nodes applied with pre-tightening force. Four full-size node test models in two groups were designed for low-cycle repeated loading quasi-static test. Through observation of the stress, distortion, failure process and failure mode of node models, analysis was made on its load-carrying capacity, deformation performance and energy dissipation capacity, and the reliability of the new node was verified. The results showed that: under action of the beam-end stiffener, the plastic hinges on the end of wave web steel beam are displaced outward and played its role of energy dissipation capacity. The study results provided reliable theoretical basis for the engineering application of the new types of nodes.

Experimental study of welding effect on grade S690Q high strength steel butt joint

  • Chen, Cheng;Chiew, Sing Ping;Zhao, Mingshan;Lee, Chi King;Fung, Tat Ching
    • Steel and Composite Structures
    • /
    • 제39권4호
    • /
    • pp.401-417
    • /
    • 2021
  • This study experimentally reveals the influence of welding on grade S690Q high strength steel (HSS) butt joints from both micro and macro levels. Total eight butt joints, taking plate thickness and welding heat input as principal factors, were welded by shielded metal arc welding. In micro level, the microstructure transformations of the coarse grain heat affected zone (CGHAZ), the fine grain heat affected zone (FGHAZ) and the tempering zone occurred during welding were observed under light optical microscopy, and the corresponding mechanical performance of those areas were explored by micro-hardness tests. In macro level, standard tensile tests were conducted to investigate the impacts of welding on tensile behaviour of S690Q HSS butt joints. The test results showed that the main microstructure of S690Q HSS before welding was tempered martensite. After welding, the original microstructure was transformed to granular bainite in the CGHAZ, and to ferrite and cementite in the FGHAZ. For the tempering zone, some temper martensite decomposed to ferrite. The performed micro-hardness tests revealed that an obvious "soft layer" occurred in HAZ, and the HAZ size increased as the heat input increased. However, under the same level of heat input, the HAZ size decreased as the plate thickness increased. Subsequent coupon tensile tests found that all joints eventually failed within the HAZ with reduced tensile strength when compared with the base material. Similar to the size of the HAZ, the reduction of tensile strength increased as the welding heat input increased but decreased as the thickness of the plate increased.

Analysis and prediction of ultimate strength of high-strength SFRC plates under in-plane and transverse loads

  • Perumal, Ramadoss;Palanivel, S.
    • Structural Engineering and Mechanics
    • /
    • 제52권6호
    • /
    • pp.1273-1287
    • /
    • 2014
  • Plates are most widely used in the hulls of floating concrete structures, bridge decks, walls of off-shore structures and liquid storage tanks. A method of analysis is presented for the determination of load-deflection response and ultimate strength of high-strength steel fiber reinforced concrete (HSSFRC) plates simply supported on all four edges and subjected to combined action of external compressive in-plane and transverse loads. The behavior of HSSFRC plate specimens subjected to combined uniaxial in-plane and transverse loads was investigated. The proposed analytical method is compared to the physical test results, and shows good agreement. To predict the constitutive behavior of HSSFRC in compression, a non-dimensional characteristic equation was proposed and found to give reasonable accuracy.

Numerical investigation of buckling-restrained steel plate shear wall under fire loading

  • Masoumi-Zahaneh, Fereydoon;Hoseinzadeh, Mohamad;Rahimi, Sepideh;Ebadi-Jamkhaneh, Mehdi
    • Earthquakes and Structures
    • /
    • 제23권1호
    • /
    • pp.59-73
    • /
    • 2022
  • In this study, the seismic behavior of an all-steel buckling-restrained (AB) steel plate shear wall (SPSW) with incline slits under fire and cyclic loading was investigated. ABSPSW was composed of two thin steel infill plates with a narrow distance from each other, which were embedded with incline slits on each plate. These slits were in opposite directions to each other. The finite element (FE) numerical model was validated with three test specimens and after ensuring the modeling strategy, the parametric study was performed by considering variables such as wall plate thickness, slit width, strip width between two slits, and degree of temperature. A total of 256 FE numerical models were subjected to coupled temperature-displacement analysis. The results of the analysis showed that the high temperature reduced the seismic performance of the ABSPSW so that at 917℃, the load-bearing capacity was reduced by 92%. In addition, with the increase in the temperature, the yield point of the infill plate and frame occurred in a small displacement. The average decrease in shear strength at 458℃, 642℃, and 917℃ was 18%, 46%, and 92%, respectively, compared to the shear strength at 20℃. Also, with increasing the temperature to 917℃, ductility increased by an average of 75%

고장력 강판의 초음파 피로시험 (Ultrasonic Fatigue Test for a High Strength Steel Plate)

  • 염현호;정용찬;김차영;강기영;이문구;홍민성;전용호
    • 한국생산제조학회지
    • /
    • 제24권6호
    • /
    • pp.589-593
    • /
    • 2015
  • The demand of high cycle fatigue behavior on plate material is increasing because of its various applications. However, the high-cycle fatigue life data of the plate material is very rare compared to the rod material. Thus, in this study, a plate specimen is designed for the ultrasonic fatigue test because it is time efficient as compared to the conventional fatigue test. To apply the ultrasonic fatigue test, the specimen design is required to resonate at 20 kHz. Therefore, the dynamic elastic modulus was determined by measuring the resonance frequency with a piezoelectric element and laser doppler vibrometer (LDV). As a result, the plate specimen is designed and demonstrated using the ultrasonic fatigue testing machine. The ultrasonic fatigue test results were compared with the hydraulic fatigue test results.