• 제목/요약/키워드: high-strength reinforcement

검색결과 838건 처리시간 0.036초

고장력 철근을 사용한 RC 보의 휨연성 평가 (Assessment of Flexural Ductility in RC Beams with High-Strength Reinforcement)

  • 권순범;윤영수;이만섭;임철현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.897-902
    • /
    • 2001
  • Recently, structure performance is maximized by using high strength concrete. In design of structure, concrete need combination with reinforcement, but use of common strength reinforcement make member complex bar placement, so high strength concrete members require increased strength reinforcement. If common strength reinforcement replaced by equal tension area of high strength reinforcement, reinforcement ratio increase and brittle failure of member may occur by material change. So, adequate upper limit of strength ratio is required to affirm ductile behavior in application of high strength reinforcement. In this study, ductility behavior was analysed by factor of reinforcement ratio, strength of concrete and reinforcement. The result indicate that ductile failure is shown under 0.35 $\rho_{b}$ in any reinforcement strength of same section and high strength concrete of 800kg/$cm^{2}$ used commonly is compatible with reinforcement of 5500kg/$cm^{2}$.

  • PDF

Experimental behavior and shear bearing capacity calculation of RC columns with a vertical splitting failure

  • Wang, Peng;Shi, Qing X.;Wang, Qiu W.;Tao, Yi
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1233-1250
    • /
    • 2015
  • The behavior of reinforced concrete (RC) columns made from high strength materials was investigated experimentally. Six high-strength concrete specimen columns (1:4 scale), which included three with high-strength transverse reinforcing bars and three with normal-strength transverse reinforcement, were tested under double curvature bending load. The effects of yielding strength and ratio of transverse reinforcement on the cracking patterns, hysteretic response, shear strength, ductility, strength reduction, energy dissipation and strain of reinforcement were studied. The test results indicated that all specimens failed in splitting failure, and specimens with high-strength transverse reinforcement exhibited better seismic performance than those with normal-strength transverse reinforcement. It also demonstrated that the strength of high-strength lateral reinforcing bars was fully utilized at the ultimate displacements. Shear strength formula of short concrete columns, which experienced a splitting failure, was proposed based on the Chinese concrete code. To enhance the applicability of the model, it was corroborated with 47 short concrete columns selected from the literature available. The results indicated that, the proposed method can give better predictions of shear strength for short columns that experienced a splitting failure than other shear strength models of ACI 318 and Chinese concrete codes.

Seismic tests of RC shear walls confined with high-strength rectangular spiral reinforcement

  • Zhao, Huajing;Li, Qingning;Song, Can;Jiang, Haotian;Zhao, Jun
    • Steel and Composite Structures
    • /
    • 제24권1호
    • /
    • pp.1-13
    • /
    • 2017
  • In order to improve the deformation capacity of the high-strength concrete shear wall, five high-strength concrete shear wall specimens confined with high-strength rectangular spiral reinforcement (HRSR) possessing different parameters, were designed in this paper. One specimen was only adopted high-strength rectangular spiral hoops in embedded columns, the rest of the four specimens were used high-strength rectangular spiral hoops in embedded columns, and high-strength spiral horizontal distribution reinforcement were used in the wall body. Pseudo-static test were carried out on high-strength concrete shear wall specimens confined with HRSR, to study the influence of the factors of longitudinal reinforcement ratio, hoop reinforcement form and the spiral stirrups outer the wall on the failure modes, failure mechanism, ductility, hysteresis characteristics, stiffness degradation and energy dissipation capacity of the shear wall. Results showed that using HRSR as hoops and transverse reinforcements could restrain concrete, slow load carrying capacity degeneration, improve the load carrying capacity and ductility of shear walls; under the vertical force, seismic performance of the RC shear wall with high axial compression ratio can be significantly improved through plastic hinge area or the whole body of the shear wall equipped with outer HRSR.

축력과 반복횡력을 받는 고강도 R/C 기둥의 횡보강근 효과에 관한 실험적 연구 (An Experimental Study on the Effects of Lateral Reinforcement of High-Strength R/C Columns Subjected to Reversed Cyclic and Axial Forces)

  • 한범석;이지영;안종문;이광수;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.493-498
    • /
    • 1998
  • An experimental investigation was conducted to examine the behavior of high-strength concrete R/C columns subjected to moment, shear and axial load. The test parameters of specimens were the compressive strength of concrete(f'c=250, 516, 600kg/ ㎠), space of lateral reinforcement (20, 30, 37cm) and lateral reinforcement ratio(ρs=2.1, 3.15%). Test results indicated that compressive strength of concrete and lateral reinforcement can significantly affect and alter the behavior of column under inelastic cyclic loadings. Despite of the defaults of high-strength concrete, with increased amount of lateral reinforcement ratio to core concrete and added sub-lateral reinforcement, ductility and strength of RC columns used high-strength concrete can secured.

  • PDF

원전구조물의 고강도철근 설계 최적화 방안 (Design Optimization of Nuclear Power Plant Structures with High-Strength Reinforcements)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.137-138
    • /
    • 2017
  • Generally, a lot of reinforcements are used in nuclear power plant concrete structures in order to improve the structural safety, but it may cause several potential problems due to the overcrowded reinforcement, such as the degradation of concrete quality, the construction delay and the increase of construction cost. In order to resolve these problems, structural test researches and code change studies on using high-strength reinforcement (Gr.80) in unclear power plant structures are under way, and there is good progress in code change of ASM BPVC.III.2 and ACI 349. This purpose of this study is to review the code change status ASM BPVC.III.2, ACI 349 under way to use the high-strength reinforcement in nuclear power plant structures. Also I will introduce the design optimization of NPP structures with high-strength reinforcements in order to maximize the effect and minimize the problem when using the high-strength reinforcements in NPP structures.

  • PDF

고강도 강관 보강 그라우팅의 현장 적용성에 관한 연구 (A study on the field application of high strength steel pipe reinforcement grouting)

  • 신현강;정혁상;유용선;김동훈
    • 한국터널지하공간학회 논문집
    • /
    • 제21권4호
    • /
    • pp.455-478
    • /
    • 2019
  • 본 논문에서는 고강도 강관을 이용한 강관 보강 그라우팅의 보강 효과 검증을 통해 현장 적용성에 관한 실험적 내용을 다루었다. 기존 강관보강 그라우팅 공법에는 SGT275 (구 STK400) 강관을 일반적으로 적용하고 있으나, 강관 보강 그라우팅이 적용된 터널의 붕락사례를 보면 강관의 과도한 꺾임, 파단 등의 사례가 발생되고 있다. 이러한 사례가 발생하는 여러 원인 중 굴착에 따른 터널의 이완하중에 대응하는 강관의 강성 부족이 그 원인이 될 수 있다. 최근 들어 고강도 강관(SGT550)의 개발로 강관의 강도가 증가했으나, 강도 증대를 고려한 보강방안에 대한 연구가 미흡하므로 이에 대한 연구가 필요한 실정이다. 따라서 본 연구에서는 고강도 강관과 일반 강관의 이음 유무, 주입재의 충전 여부 등 다양한 조건에 대해 인장강도 및 휨 전단력 실험을 수행하고, 기존 제시된 설계법을 통해 강관의 강도 차이에 따른 효율적인 현장 적용성에 대한 기초 연구를 수행하였다. 특히, 실제 현장에 고강도 강관과 일반 강관을 시공하고 굴착에 따른 강관의 변위형상과 응력에 대한 계측 결과를 통해 고강도 강관의 보강 효과를 검증하였다. 연구결과 고강도 강관은 휨 강도가 우수하여 보강효과가 우수한 것으로 나타났으며, 강도 증진효과로 인해 아칭효과도 기대된다.

초고강도 철근콘크리트 띠철근 기둥의 구속효과 (Confined Effect of Ultra High Strength Reinforced Concrete Tied Columns)

  • 한범석;신성우;김태수
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.105-111
    • /
    • 2007
  • As this study investigates the influence about type of transverse reinforcement, spacing of transverse reinforcement(s), volumetric ratios of transverse reinforcement(${\rho}s$) of ultra-high strength concrete columns. It try to offer to resonable basic data of the confined model for the ultra-high concrete of in reinforced concrete columns. Experimental tests with large scaled columns were conducted under concentric axial loads. The ultra-high strength concrete (100MPa) was used. From this test result, it evaluate influence of the strength enhancement and ductility enhancement, important variables about behavior of the confined concrete by confinement of ultra-high strength reinforced concrete.There are two ways to improve the confinement effect of high strength concrete columns through the increase of amounts and/or strength of transverse reinforcement.

편심하증을 받는 고강도 철근콘크리트 기둥의 역학적 특성 (Mechanical Characteristics of Eccentrically Loaded High Strength Reinforced Concrete Columns)

  • 김인식;최봉섭;권영웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.399-404
    • /
    • 2000
  • This paper are the mechanical characteristics of eccentrically loaded normal strength and high strength reinforced concrete columns based on the test results. The columns are $120\times120$mmat the mid-section and are haunched at the ends to apply the eccentric loading and prevent premature failure. Variables are concrete strengths(361, 672, 974 kgf/$\textrm{cm}^2$), $\textrm{cm}^2$longitudinal reinforcement ratios (1.98, 3.54, 1 5.53%), spacing of lateral reinforcement (30, 60, 120mm), and eccentricities (24, 40mm). As a results, the main conclusions obtained from the comparison and analysis for the strength tendency, deformation and ductility of high strength reinforced concrete columns with variables are as follows; As the concrete compressive strength concrete and lateral reinforcement increases, the ductility index of high strength reinforced concrete columns decrease, but it increase with the increase of eccentricity and longitudinal reinforcement ratio. The confinement ratio must be greater than 20 percent in order for the level of ductility between high strength reinforced concrete columns and normal strength reinforced concrete columns to be almost equal.

  • PDF

고강도 비틀림보강철근을 사용한 철근콘크리트 보의 파괴모드 (Failure Modes of RC Beams with High Strength Reinforcement)

  • 윤석광;이수찬;이도형;이정윤
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.143-150
    • /
    • 2014
  • 콘크리트의 압축파괴에 의한 취성적인 비틀림파괴와 사인장균열의 폭을 제한하기 위하여 콘크리트구조기준은 비틀림보강철근의 항복강도를 제한하고 있다. 2012년에 콘크리트구조기준에서는 비틀림보강철근의 항복강도를 400 MPa에서 500 MPa로 상향하였다. 그 이유는 500 MPa의 비틀림보강철근을 사용한 비틀림부재의 경우에도 전단파괴하는 부재와 유사하게 기준에서 요구하는 비틀림파괴모드, 사용성, 경제성을 만족시킬 수 있을 것으로 판단하였기 때문이다. 그러나 현재 고강도 비틀림보강철근을 사용한 비틀림부재에 대한 연구는 전단부재에 대한 연구에 비하여 부족한 실정이다. 이 연구에서는 340 MPa, 480 MPa, 667 MPa의 비틀림보강철근을 사용한 철근콘크리트 보의 비틀림거동을 실험적으로 평가하였다. 실험에 의하면 비틀림보강철근의 파괴모드는 비틀림보강철근의 항복강도와 콘크리트의 압축강도에 의하여 영향을 받았다. 비틀림보강철근의 항복강도가 400 MPa이하인 경우에는 콘크리트의 압축강도와 무관하게 한 곳 이상에서 비틀림보강철근이 항복강도에 도달하여 비틀림인장파괴하였지만, 항복강도가 480 MPa 이상인 경우에는 비틀림보강철근이 항복하지 않는 경우가 발생하여 이에 대한 추가적인 연구가 필요할 것으로 판단된다.

고장력 주인장 철근을 사용한 전단보강이 없는 보의 전단성능에 관한 연구 (Shear Behavior of High-Strength Steel Reinforced Concrete Beams without Stirrups)

  • 손영무;윤영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.203-210
    • /
    • 2002
  • In these days, High-strength steel prevails throughout the construction fields for the benefit of structural and economical aspects. But high-strength steel is used by the simple calculation of flexural capacities for the purpose of reducing flexural reinforcement. So, this paper is mainly focused on the shear behavior of high-strength steel reinforced concrete beams without stirrups comparing with normal-strength steel reinforced concrete beams. Specimens were made and tested with the experimental parameters, such as steel yield strength, reinforcement ratios and minimum shear reinforcement. The main result was that not only area but also the yield strength of flexural reinforcement should be considered to predict the shear capacities of concrete beams. In addition, the experimental results were simulated by modified compression field theory analysis program, RESPONSE 2000. A good agreement was achieved between the test results and program analyses.