• 제목/요약/키워드: high-speed curing

검색결과 44건 처리시간 0.027초

롤투롤 공정의 인쇄 후 구간에서 변형률과 인쇄한 패턴의 전기 전도도와의 관계에 대한 연구 (A study on the Relation between Strain & Conductivity of the Printed Pattern in Post-Printing Section of Roll to Roll process)

  • 최재호;이창우;신기현
    • 제어로봇시스템학회논문지
    • /
    • 제15권9호
    • /
    • pp.877-880
    • /
    • 2009
  • A curing process in post-printing section of R2R process is required for an electrical property of the printed pattern when devices such as RFID, Solar cell are printed. PEN as well as heat-stabilized PET which is used as a plastic substrate would be deformed at high temperature due to change of its elastic modulus. And crack in the printed pattern, which is on the plastic substrate is occurred due to the deformation of the substrate. The occurrence of crack causes electrical resistance to increase and the quality of the device to deteriorate. In case of RFID antenna, the range of reading distance is shortened as the electrical resistance of the antenna is increased. Therefore, the deformation of the plastic substrate, which causes the occurrence of crack, should be minimized by setting up low operating tension in R2R process. In low tension, slippage between a moving substrate and a roller would be generated when the operating speed is increased. And scratch would be occurred when slippage is generated due to an air entrainment, which is related to the thickness of the air film. The thickness of the air film is increased when operating speed is increased as shown by simulation based on mathematical model. The occurrence of scratch in conductive pattern printed by roll to roll process is a critical damage because it causes degradation or failure of electrical property of it.

속경화용 탄소섬유/에폭시 프리프레그의 다단 압축 성형기술 (Multi-stage Compression Molding Technology of Fast Curing CF/Epoxy Prepreg)

  • 곽성훈;문지훈;홍상휘;권순덕;김병하;김태용
    • Composites Research
    • /
    • 제34권5호
    • /
    • pp.269-276
    • /
    • 2021
  • 프리프레그 압축성형(PCM, Prepreg Compression Molding) 공정은 고품질 CFRP(Carbon Fiber Reinforced Plastic) 제품을 제조할 수 있는 고속성형기술이다. 오토클레이브 공정에 비해 폐기물 발생이 적고 사이클타임을 크게 줄일 수 있어 항공우주 및 자동차 산업에서 다양한 연구가 진행되고 있다. 본 연구에서는 PCM 공정의 품질을 높이기 위해 프리프레그의 경화거동을 따라 프레스의 압축압력을 단계별로 증가시키는 성형법에 대해 연구하였고, 이러한 다단 압축 성형법이 우수한 품질의 CFRP 제품을 생산하고 사이클타임을 단축할 수 있는 좋은 수단임을 확인하였다. 그리고 상온에서 적층한 프리프레그를 금형에 투입하여 예열과 성형을 동시에 함으로써 별도의 예열 공정 없이 제품을 성형할 수 있었다. 또한 평판 성형에 최적화된 공정조건을 3차원 형상물에 동일하게 적용한 결과 외관상 평판과 유사한 제품을 공정조건 수립 과정 없이 만들 수 있었다.

연마 과정에 따른 열중합 의치상 레진의 표면 거칠기 평가 (Evaluation of surface roughness of heat-polymerized denture base resin according to the polishing step)

  • 황성식;임용운;김시철;한민수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.205-212
    • /
    • 2015
  • Purpose: The objective of this study was to compare the surface roughness according to polishing process in conventional laboratory techniques used for polishing three different acrylic denture base resins. Materials and methods: Specimen preparation and surface polishing procedures were conducted to manufacturer's recommendation with three heat-polymerized denture base resins. Surface roughness and gloss were measured by a contact type tester and a LED gloss checker using thickness 2 mm and diameter 10 mm. There were five specimens for each acrylic resin material and polishing procedures. Mean average surface roughness (Ra) values of each specimen group were analyzed using a one-way ANOVA analysis of variance and Scheffe's post hoc test. Surfaces after surface roughness and gloss testing according to each polishing process were evaluated under a stereoscopic microscope. Results: The highest mean average surface roughness was measured($Ra=2.43{\pm}0.47$) for surfaces finished with a denture tungsten carbide bur in Triplex. The lowest surface roughness values ($Ra=0.11{\pm}0.07$) were determined in Vertex polished with a lathe. In addition, all materials revealed that surface roughness determined highly in HP1 and HP2 than other procedures. All correlation between surface roughness and gloss showed highly with three heat-polymerized resins. Specially, topmost correlation revealed than other material in Triplex. Significant differences in mean average surface roughness were found between polishing process used high speed lathe and low speed hand-piece. Conclusion: Laboratory polishing used to high speed was found to produce the smoothest surface of heat-polymerized denture base acrylic resin. Therefore, we recommended that high polishing process need to get smooth surface.

복합레진의 exponential 중합법이 상아질접착제의 미세인장접착강도에 미치는 영향 (EFFECT OF THE EXPONENTIAL CURING OF COMPOSITE RESIN ON THE MICROTENSILE DENTIN BOND STRENGTH OF ADHESIVES)

  • 성소래;서덕규;이인복;손호현;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.125-133
    • /
    • 2010
  • 접착제를 통해 치아에 접착되는 상부의 복합레진의 빠른 중합은 접착제층에 높은 중합수축응력을 발생시킨다. 중합수축응력을 경감시키기 위해서, LED 광중합기의 하나인 Elipar FreeLight 2 (3M ESPE, USA)에서는 최초 5초 이내에 광강도를 증가시키는 exponential 중합법을 채택하고 있다. 본 연구에서는 짧은 시간내에 광강도를 증가시키는 exponential 중합법이 복합레진의 초기 중합수축속도를 효과적으로 조절할 수 있는지를 알아보기 위해 접착제 적용 후 상부의 복합레진을 exponential 중합법과 continuous 중합법으로 중합하여 상아질접착제의 미세인장접착강도를 비교하였다. 3M사의 Scotchbond Multipurpose Plus (MP), Single Bond 2 (SB), 및 Adper Prompt (AP)의 세 종류의 접착제를 발치한 대구치의 교합면 상아질에 제조사의 지시에 따라 적용하고, 혼합형 복합레진인 Denfil (Vericom, Korea)을 두 가지광중합방법으로 중합하였다. 접착 후 48시간에 미세인장접착강도를 측정하고, 파절면은 FE-SEM.으로 관찰하였다. 그 결과, 각각의 접착제에서 중합방법에 따른 접착강도의 차이는 관찰할 수 없었다(Two-way ANOVA, p > 0.05). MP와 SB의 미세인장접착강도는 AP에 비해 유의하게 높았다(p < 0.05). 대부분의 파절시편에서는 혼합형 파절이 가장 많이 관찰되었으나, 중합방법에 따른 파절양상의 차이는 없었다. 결론적으로 5초 이내의 짧은 시간에 광강도를 증가시키는 exponential 중합법은 continuous 중합법과 비교하여 상아질접착제의 미세인장접착강도에 영향을 주지 않았다.

UV Curing 공정을 이용한 오피스용 SFF System 개발 (Development of Office Type SFF System)

  • 권정재;조현택;백영종;김동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1400-1403
    • /
    • 2007
  • The 3DP(three dimensional printing) technology is one of the SFF(solid freeform fabrication) technologies which has recently come into a spotlight due to its suitability to various field. A manufacturing process of product is using many pattern formation technology. The 3DP technology uses multi nozzle that can fabricate three dimensional object of high speed and accuracy. In this paper, we introduce a development of the office type solid freeform fabrication system. This system is used UV resin and multi-piezo head.

  • PDF

InGaAs 도파로형 광다이오드의 암전류에 대한 열 처리 효과에 관한 연구 (The Study of Annealing Effect on the Dark Current of InGaAs Waveguide Photodiodes)

  • 이봉용;주한성;윤일구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.961-964
    • /
    • 2003
  • This paper presents the temperature annealing effect on the dark current of the InGaAs waveguide photodiodes, which are developed for high-speed optical receivers. The interesting experimental phenomena were observed that the dark current is significantly decreased and the breakdown voltage is slightly increased after annealing at $250^{\circ}C$ whereas the dark current and the breakdown voltage are almost constant after annealing at $200^{\circ}C$. Based on the experimental results, the long-term annealing is more effective for the dark current improvement than the conventional curing process.

  • PDF

북한 초고층 아파트의 공사속도와 구조 안전에 관한 연구 (A Study on the Construction Speed and Structural Safety of a High-Rise Apartments in North Korea)

  • 김장한
    • 한국건설관리학회논문집
    • /
    • 제23권5호
    • /
    • pp.15-22
    • /
    • 2022
  • 평양 여명거리의 70층 초고층 아파트는 불과 75일 만에 지상 골조공사가 완료되어 구조적 안전성에 의문이 제기됐다. 본 연구는 이 의문에 대한 답을 구하여 향후 남북 건설협력에 일조하기 위해 진행됐다. 구글어스와 북한 측 자료를 분석한 결과, 몇 가지 조건 아래에서 얕은기초의 적용, 콘크리트 강도와 양생기간을 포함한 공사속도, 그리고 적어도 2022년 5월 현재까지는 구조적 안전에 문제가 없었음을 추정할 수 있었다. 이로써, 북한식 초고층 아파트 건축공사 방식이 남한 기준으로도 이해될 가능성을 확인했고, 이는 향후 북한에서 남북 건축사업 합작 시 북한식 건축공사의 적용과 남한 자원의 최소 이동을 가능케 하여 성공적인 합작 건설사업 수행에 도움이 될 수 있다.

천연 수경성 석회(NHL)를 사용한 고분벽화 벽체 보강제 적용성 연구 (The Application of Natural Hydraulic Lime as a Reinforcing Agent for Mural Paintings in Ancient Tombs)

  • 유영경;이화수
    • 박물관보존과학
    • /
    • 제21권
    • /
    • pp.29-40
    • /
    • 2019
  • 고분벽화 벽체 보강제로써 천연 수경성 석회의 적용 가능성을 확인하고자 실험연구를 실시하고 그 결과를 제시하였다. 선행된 고구려 고분벽화 관련 연구를 통해 벽체 의사시료와 NHL 제품을 활용한 조건별 보강제 시료를 제작하였다. 시료는 고분 내부 환경을 고려한 고습 조건에서 7일, 28일, 84일간 양생하였으며, 기간별 치수안정성 및 강도 등 물성평가를 수행하였다. 실험 결과, NHL 제품은 경화속도가 빠르고 수축률이 적어 보강제로써의 적합성은 확인되었으나 벽체 물성대비 강도 차이가 크고 백색도가 떨어지는 등의 단점이 확인되었다. 치수안정성 및 압축강도 평가 결과 NHL 제품과 고분벽화 벽체 의사시편을 혼합한 조건이 상대적으로 벽체 보강제로써 적합한 값을 지닌 것으로 나타났다. 따라서 손상된 고분벽화 벽체 보강제로 천연 수경성 석회를 적용하기 위해서는 대상 벽체의 조건에 따라 적합한 경화시간 및 강도를 발현할 수 있는 조건이 고려되어야 할 것으로 판단된다.

복합재료 부품 표면에 다양한 딤플을 형성하는 성형 방법 (A Study on the Processing Technique to form Various Dimples on the Surface of Composite Parts)

  • 조치룡;변길재
    • Composites Research
    • /
    • 제26권1호
    • /
    • pp.42-47
    • /
    • 2013
  • 본 연구에서는 공기역학적 또는 열 전달에 유리한 형상인 딤플을 복합재료 제품의 표면에 다수 형성하는 경제적이고도 효과적인 성형방법을 개발하였다. 금형을 이용하여 제품의 표면에 다수의 딤플을 형성시키려면 몰드의 표면에 볼록한 반구형상을 가공하여야 하는데 이렇게 하려면 높은 금형 제작비가 소요된다. 본 연구에서는 다수의 원형 구멍이 뚫린 판재를 이용하여, 이의 표면에 복합재료 스킨을 입히면서 외부에서 압력을 가하여 딤플 형상이 표면에 자연스럽게 형성되도록 하는 방법을 개발하였다. 표면에 다수의 딤플을 갖는 복합재료는 공기저항을 줄이거나 방열효과가 필요한 고속 경기용 자동차의 외장 등으로 널리 응용 될 수 있을 것으로 사료된다.

구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구 (THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS)

  • 박연홍;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF