• 제목/요약/키워드: high-speed camera

검색결과 926건 처리시간 0.026초

반응성구조체의 고속충돌에 따른 온도분포 분석 (Analysis on Temperature Profiles upon High Speed Impact of Reactive Structural Materials)

  • 정상현;조수경;배광태;이기봉
    • 한국군사과학기술학회지
    • /
    • 제20권5호
    • /
    • pp.654-664
    • /
    • 2017
  • The temperature profiles upon high speed impact of reactive structural materials were analyzed. A two color pyrometer, which included high-speed camera, spectral splitter, and band pass filters, was utilized to measure transient temperature profiles during and after reactive metal samples impacted into steel plate with velocities of 1600~1700 m/s. The spatial temperature distribution was analyzed from the ratio of spectral radiances at two different wavelength in infrared zone, i.e. 700 and 900 nm. The measured temperatures were calibrated with black body source. Two different types of metal samples, namely aluminum and nickel, were employed to understand reaction behavior upon the impact of samples in ambient condition. According to our experiments, the Ni sample appeared to barely react with ambient air producing an instant small fireball, while Al sample reacts violently with air generating a relatively prolong fireball.

FCW의 가스 발생제가 스패터링에 미치는 영향 (Effects of gas formers of flux cored wire on spattering)

    • Journal of Welding and Joining
    • /
    • 제16권5호
    • /
    • pp.93-99
    • /
    • 1998
  • Effects of gas formers of MgCO$_3$, CaCO$_3$ and Li$_2$CO$_3$ on the spattering phenomena were investigated for non-shielded flux cored arc welding. Spattering phenomena were pictured using high speed camera as a speed of 3000 frames per sec. As experimental results, spattering modes were classified into 4 types. The modes were spattering by arc force, gas explosion, short circuit and pore escape. The amount of spatters by arc force was 30%, gas blowing force was 40%, short circuit 10%, pore escape was 10% and others were 10%. When Li$_2$CO$_3$ was added, the amount of spatters was largest, and it decreased in the order of CaCO$_3$ and MgCO$_3$.

  • PDF

4절 링크기구의 유연성 해석 (Flexibility Analysis of 4-Bar Linkage Mechanism)

  • 조선휘;박종근;한성현
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1365-1373
    • /
    • 1994
  • Elasto-dynamic deformation of flexible linkage mechanism was analyzed using the finite element method. A computer program was constructed and applied to analyze a specific crank-level 4-bar mechanism, in which the elasto-dynamic deformation of the mechanism system was obtained using mode superposition method in the case of constant input speed and the effect of geometric stiffness on the mechanism is included. Experimental verification of numerical results was conducted by measuring the elasto-dynamic deformation of mid-points of coupler and lever for the 4-bar lingkage mechanism using high speed camera and image data processing systeem. For the elasto-dynamic deformation at the lever mid-point, the numerical results including geometric stiffness almost agree with the experimental ones. However, the numerical results excluding geometric stiffness good agree with the experimental ones at the couper mid-point.

강제 입수에 의한 슬래밍 현상에 관한 실험적 연구 (An Experimental Study on Slamming Phenomenon by Forced Impact)

  • 남종오;강효동;정장영;권순홍;최한석
    • 한국해양공학회지
    • /
    • 제21권1호
    • /
    • pp.40-44
    • /
    • 2007
  • This paper presents the experimental results on slamming phenomenon. The air pressure cylinder was used to ensure repeatability of the impact. The results showed that the adopted experimental technique was excellent in terms of repeatability, compared to that of the free drop tests. The pressure time histories, magnitude of peak pressure and the behavior of jetspray were obtained. The flat specimen was tested for various incident angles. To estimate the incident speed of the specimen, a high-speed camera was used. The high-speed camera was also a useful tool in understanding the behavior.

PIV System for the Flow Pattern Anaysis of Artificial Organs ; Applied to the In Vitro Test of Artificial Heart Valves

  • Lee, Dong-Hyeok;Seh, Soo-Won;An, Hyuk;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.489-497
    • /
    • 1994
  • The most serious problems related to the cardiovascular prothesis are thrombosis and hemolysis. It is known that the flow pattern of cardiovascular prostheses is highly correlated with thrombosis and hemolysis. Laser Doppler Anemometry (LDA) is a usual method to get flow pattern, which is difficult to operate and has narrow measure region. Particle Image Velocimetry (PIV) can solve these problems. Because the flow speed of valve is too high to catch particles by CCD camera, high-speed camera (Hyspeed : Holland-Photonics) was used. The estimated maximum flow speed was 5m/sec and maximum trackable length is 0.5 cm, so the shutter speed was determined as 1000 frames per sec. Several image processing techniques (blurring, segmentation, morphology, etc) were used for the preprocessing. Particle tracking algorithm and 2-D interpolation technique which were necessary in making gridrized velocity pronto, were applied to this PIV program. By using Single-Pulse Multi-Frame particle tracking algorithm, some problems of PIV can be solved. To eliminate particles which penetrate the sheeted plane and to determine the direction of particle paths are these solving methods. 1-D relaxation fomula is modified to interpolate 2-D field. Parachute artificial heart valve which was developed by Seoul National University and Bjork-Shiely valve was testified. For each valve, different flow pattern, velocity profile, wall shear stress and mean velocity were obtained.

  • PDF

Observation of bubble dynamics under water in high-magnetic fields using a high-speed video camera

  • Lee, Seung-Hwan;Minoru Takeda
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.291-298
    • /
    • 2004
  • The observations of rapid motion of bubbles under water for approximately 50 ms or less in high-magnetic fields of 10 T have been carried out successfully for the first time. The observation system constructed is composed of a high-speed video camera, a telescope, a cryostat with a split-type superconducting magnet, a light source, a mirror and a transparent sample cell. Using this system, the influence of magnetic field on the path and shape of single bubbles of O$_2$ (paramagnetism) and N$_2$ (diamagnetism) has been examined carefully. Experimental values describing the path are in good agreement with theoretical values calculated on the basis of the magneto-Archimedes effect, despite the effect of magnetism on the bubble. However, no effect of magnetism on the shape of the bubble is observed. In addition, the influence of magnetic field on drag coefficient of the bubble is discussed.

  • PDF

Visualization of Underwater Sympathetic Detonation of High Explosives

  • Itoh, Shigeru;Hamada, Toru;Murata, Kenji;Kato, Yukio
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1822-1828
    • /
    • 2001
  • The experiment for the sympathetic detonation (Sudo et al., 1951) (Fukuyama et al., 1958) in water was conducted. Composition B (RDX: 64%, TNT: 36%, Detonation velocity: 7900m/s) was used for both donor (the thickness was 50mm, and the diameter was 31mm) and receptor charges. The distance between the donor and the receptor, and the thickness (5, 7.5, 10mm) of the receptor were varied in the experiments. In order to investigate the basic characteristics of the underwater sympathetic detonation of high explosive, the sympathetic detonation phenomena were visualized by a high-speed camera (HADLAND PHOTONICS, IMACON790) in forms of streak and framing photographs. The 200ns/mm streak velocity was 2㎲. Manganin gauges (KYOWA Electronic INSTRUMENTS CO. SKF-21725) were used for the pressure measurements. The gauges were set under the receptor. The pressures during the complete and incomplete explosions were measured.

  • PDF

Observation of bubble dynamics under water in high-magnetic fields using a high-speed video camera

  • Lee, Seung-Hwan;Takeda, Minoru
    • 한국항해항만학회지
    • /
    • 제28권2호
    • /
    • pp.141-148
    • /
    • 2004
  • The observations of rapid motion of bubbles under water for approximately 50ms or less in high . magnetic fields of 10 T have been carried out successfully for the first time. The observation system constructed is composed of a high-speed video camera, a telescope, a cryostat with a split-type superconducting magnet, a light source, a mirror and a transparent sample cell. Using this system, the influence of magnetic field on the path and shape of single bubbles of $O_2$(paramagnetism) and $N_2$ (diamagnetism) has been examined carefully. Experimental values describing the path are in good agreement with theoretical values calculated on the basis of the magneto-Archimedes effect, despite the effect of magnetism on the bubble. However, no effect of magnetism on the shape of the bubble is observed In addition, the influence of magnetic field on drag coefficient of the bubble is discussed.

Bare Glass Inspection System using Line Scan Camera

  • Baek, Gyeoung-Hun;Cho, Seog-Bin;Jung, Sung-Yoon;Baek, Kwang-Ryul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1565-1567
    • /
    • 2004
  • Various defects are found in FPD (Flat Panel Display) manufacturing process. So detecting these defects early and reprocessing them is an important factor that reduces the cost of production. In this paper, the bare glass inspection system for the FPD which is the early process inspection system in the FPD manufacturing process is designed and implemented using the high performance and accuracy CCD line scan camera. For the preprocessing of the high speed line image data, the Image Processing Part (IPP) is designed and implemented using high performance DSP (Digital signal Processor), FIFO (First in First out), FPGA (Field Programmable Gate Array) and the Data Management and System Control part are implemented using ARM (Advanced RISC Machine) processor to control many IPP and cameras and to provide remote users with processed data. For evaluating implemented system, experiment environment which has an area camera for reviewing and moving shelf is made.

  • PDF

중변형률 속도 유동응력 확보를 위한 고속 인장 실험기 설계 (Design of High Speed Tensile Test Machine for Flow Stress under Intermediate Strain Rate Condition)

  • 정준모;윤성원;박성주;김영훈
    • 한국해양공학회지
    • /
    • 제29권1호
    • /
    • pp.34-44
    • /
    • 2015
  • A hydraulic tensile test machine (HSTM) is one of the devices used to obtain the flow stress of a material during high-speed elongation. This paper first describes some features of a newly built HSTM. The improvement histories of the upper and lower jigs, which are the most vital parts of the HSTM, are also presented. We have frequently witnessed test failures with 1st generation jigs and specimens due to slip between the jig and specimen. 2nd generation jigs provide more stable test results, but the use of a longer upper jig induces excessive vibration and consequently makes it difficult to attach an environment chamber. 3rd generation jigs have some advances in terms of the symmetric fastening between the upper jig and specimen, as well as an exemption from direct contact between the lower jig and specimen. The performance of an environment chamber is verified by high and low temperature tests. A high-speed displacement measurement system is introduced based on a high-speed camera and motion-tracking software with aid of a surface grid device for the specimen.