• 제목/요약/키워드: high-resolution transmission electron microscope

Search Result 89, Processing Time 0.025 seconds

First Remote Operation of the High Voltage Electron Microscope Newly Installed in KBSI (초고전압 투과전자현미경의 원격시범운영)

  • Kim, Young-Min;Kim, Jin-Gyu;Kim, Youn-Joong;Hur, Man-Hoi;Kwon, Kyung-Hoon
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.13-21
    • /
    • 2004
  • The high voltage electron microscope (HVEM) newly installed in KBSI is an advanced transmission electron microscope capable of atomic resolution (${\leq}1.2{\AA}$ point-to-point resolution) together with high titling function (${\pm}60^{\circ}$), which are suitable to do 3-dimensional atomic imaging of a specimen. In addition, the instrument can be controlled by remote operation system, named as 'FasTEM' for the HVEM, which is favorable to overcome some environmental obstacles resulting from the direct operation. The FasTEM remote operation system has been established between the headquarter of KBSI in Daejeon and the Seoul branch. The server system in the headquarter has been connected with a portable client console system in the Seoul branch using an advanced internet resource, 'KOREN' of 155 Mbps grade. Most of the HVEM functions essential to do remote operation are available on the portable client console. The experiment to acquire the high resolution image of [001] Au has been achieved by excellent transmission of control signals and communication with the HVEM. Real-time reaction like direct operation, such as controls of the illumination and projection parameters, acquisition and adjustment of each detector signal, and electrical steering of each motor-driven system has been realized in remote site. It is positively anticipated that the first remote operation of HVEM in conjunction with IT infraengineering plays a important role in constructing the network based e-Science Grid in Korea for national user s facilities.

Transmission Electron Microscope Sampling Method for Three-Dimensional Structure Analysis of Two-Dimensional Soft Materials

  • Lee, Sang-Gil;Lee, Ji-Hyun;Yoo, Seung Jo;Datta, Suvo Jit;Hwang, In-Chul;Yoon, Kyung-Byung;Kim, Jin-Gyu
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.203-207
    • /
    • 2015
  • Sample preparation is very important for crystal structure analysis of novel nanostructured materials in electron microscopy. Generally, a grid dispersion method has been used as transmission electron microscope (TEM) sampling method of nano-powder samples. However, it is difficult to obtain the cross-sectional information for the tabular-structured materials. In order to solve this problem, we have attempted a new sample preparation method using focused ion beam. Base on this approach, it was possible to successfully obtain the electron diffraction patterns and high-resolution TEM images of the cross-section of tabular structure. Finally, we were able to obtain three-dimensional crystallographic information of novel zeolite nano-crystal of the tabular morphology by applying the new sample preparation technique.

Recent Advances in Electron Crystallography

  • Chung, Jeong Min;Lee, Sangmin;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • v.47 no.3
    • /
    • pp.160-164
    • /
    • 2017
  • Electron crystallography has been used as the one of powerful tool for studying the structure of biological macromolecules at high resolution which is sufficient to provide details of intramolecular and intermolecular interactions at near-atomic level. Previously it commonly uses two-dimensional crystals that are periodic arrangement of biological molecules, however recent studies reported a novel technical approach to electron crystallography of three-dimensional crystals, called micro electron-diffraction (MicroED) which involves placing the irregular and small sized protein crystals in a transmission electron microscope to determine the atomic structure. In here, we review the advances in electron crystallography techniques with several recent studies. Furthermore, we discuss the future direction of this structural approach.

Theory of High Resolution TEM Image Formation: Coherence (2) (TEM 관련 이론해설(7): 투과전자현미경의 고분해능 영상이론: 결맞음 (2))

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • In this review, the important ideas of coherence theory are introduced. The transfer function and damping envelopes of the microscope due to temporal and spatial coherence are described. The passbands and the condition of Scherzer focus are discussed in associated with the resolution of transmission electron microscope. The characterization of coherence is also described.

Synthesis of Graphene Using Thermal Chemical Vapor Deposition and Application as a Grid Membrane for Transmission Electron Microscope Observation (열화학증기증착법을 이용한 그래핀의 합성 및 투과전자현미경 관찰용 그리드 멤브레인으로의 응용)

  • Lee, Byeong-Joo;Jeong, Goo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.22 no.3
    • /
    • pp.130-135
    • /
    • 2012
  • We present a method of graphene synthesis with high thickness uniformity using the thermal chemical vapor deposition (TCVD) technique; we demonstrate its application to a grid supporting membrane using transmission electron microscope (TEM) observation, particularly for nanomaterials that have smaller dimensions than the pitch of commercial grid mesh. Graphene was synthesized on electron-beam-evaporated Ni catalytic thin films. Methane and hydrogen gases were used as carbon feedstock and dilution gas, respectively. The effects of synthesis temperature and flow rate of feedstock on graphene structures have been investigated. The most effective condition for large area growth synthesis and high thickness uniformity was found to be $1000^{\circ}C$ and 5 sccm of methane. Among the various applications of the synthesized graphenes, their use as a supporting membrane of a TEM grid has been demonstrated; such a grid is useful for high resolution TEM imaging of nanoscale materials because it preserves the same focal plane over the whole grid mesh. After the graphene synthesis, we were able successfully to transfer the graphenes from the Ni substrates to the TEM grid without a polymeric mediator, so that we were able to preserve the clean surface of the as-synthesized graphene. Then, a drop of carbon nanotube (CNT) suspension was deposited onto the graphene-covered TEM grid. Finally, we performed high resolution TEM observation and obtained clear image of the carbon nanotubes, which were deposited on the graphene supporting membrane.

HRTEM Analysis of Apatite Formed on Bioactive Titanium in Modified-SBF (수정된 유사체액 내에서 티타늄에 생성된 아파타이트의 고분해능 전자현미경에 의한 분석)

  • Kim, Hyun-Ook;Kim, Woo-Jeong;Lee, Kap-Ho;Hon, Sun-Ig
    • Korean Journal of Materials Research
    • /
    • v.17 no.8
    • /
    • pp.408-413
    • /
    • 2007
  • Process of the hydroxyapapite(HA) precipitation on bioactive titanium metal prepared by NaOH in a modified-simulated body fluid(mSBF) was investigated by high resolution transmission electron microscope (HRTEM) attached with energy dispersive X-ray spectrometer(EDX). The amorphous titanate phase on titanium surface is form by NaOH treatment and an amorphous titanate incorporated calcium and phosphate ions in the liquid to form an amorphous calcium phosphate. With increasing of soaking time in the liquid, the HA particles are observed in amorphous calcium phosphate phase with a Ca/P atomic ratio of I.30. The octacalcium phosphate (OCP) structure is not detected in HRTEM image and electron diffraction pattern. After a long soaking time, the HA particles grow as needle-like shape on titanium surface and a large particle-like aggregates of needle-like substance were observed to form on titanium surface within needle-like shape. A long axis of needle parallels to c-direction of the hexagonal HA structure.

Property of Nickel Silicides on ICP-CVD Amorphous Silicon with Silicidation Temperature (ICP-CVD 비정질 실리콘에 형성된 처리온도에 따른 저온 니켈실리사이드의 물성 변화)

  • Kim, Jong-Ryul;Choi, Young-Youn;Park, Jong-Sung;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.303-310
    • /
    • 2008
  • We fabricated hydrogenated amorphous silicon(a-Si:H) 140 nm thick film on a $180\;nm-SiO_2/Si$ substrate with an inductively-coupled plasma chemical vapor deposition(ICP-CVD) equipment at $250^{\circ}C$. Moreover, 30 nm-Ni film was deposited with a thermal-evaporator sequently. Then the film stack was annealed to induce silicides by a rapid thermal annealer(RTA) at $200{\sim}500^{\circ}C$ in every $50^{\circ}C$ for 30 minuets. We employed a four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscope(FE-SEM), transmission electron microscope(TEM), and scanning probe microscope(SPM) in order to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure evolution, and surface roughness, respectively. We confirmed that nano-thick high resistive $Ni_3Si$, mid-resistive $Ni_2Si$, and low resistive NiSi phases were stable at the temperature of <300, $350{\sim}450^{\circ}C$, and >$450^{\circ}C$, respectively. Through SPM analysis, we confirmed the surface roughness of nickel silicide was below 12 nm, which implied that it was superior over employing the glass and polymer substrates.

Mineralogical Study of Sericite in the Daehyun Mine: Formation, Chemistry and Polytype (대현광산 견운모의 생성과정과 화학조성 및 폴리타잎)

  • 이병임;김수진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.69-84
    • /
    • 1998
  • The Daehyun sericite deposit in socheon-myun, Bongwha-gun, Kyungsangbuk-do, Korea, has been formed by the hydrothermal alteration of the Hongjesa granite of Precambrian age, leaving the muscovite granite between ore body and the Hongjesa granite as the wall rock alteration zone. The process of sericitization of granitic rock as well as chemistry and structures of sericites were studied using polarizing microscope, X-ray diffractometer (XRD), electron probe microanalyzer (EPMA) and high resolution transmission electron microscope (HRTEM). There are two genetic types of sericites having different chemistry and structure. The early sericite is of 2M1 polytype and has octahedral composition close to muscovite. It has been formed from the primary muscovite, tourmaline and quartz under a relatively high temperature. The late sericite is of 1M, 2M1 and 3T polytypes and has phengitic composition. It has been formed form feldspar, biotite, muscovite and tourmaline under a relatively low temperature. Chemical analyses show t, the early sericite has less Mg+FeT content and lower Si/AlIV ratio in tetrahedral site than the late sericite.

  • PDF

High Speed and Sensitive X-ray Analysis System with Automated Aberration Correction Scanning Transmission Electron Microscope

  • Inada, Hiromi;Hirayama, Yoichi;Tamura, Keiji;Terauchi, Daisuke;Namekawa, Ryoji;Shichiji, Takeharu;Sato, Takahiro;Suzuki, Yuya;Ohtsu, Yoshihiro;Watanabe, Keitaro;Konno, Mitsuru;Tanaka, Hiroyuki;Saito, Koichiro;Shimoyama, Wataru;Nakamura, Kuniyasu;Kaji, Kazutoshi;Hashimoto, Takahito
    • Applied Microscopy
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • We have developed a new HD-2700 (Hitachi High-Technologies Corp., Japan) scanning transmission electron microscope (STEM) that includes an automatic aberration correction function, and a large-solid-angle energy-dispersive X-ray spectroscopy detector that enables high-resolution and sensitive analysis. For observation with atomic resolution, using spherical-aberration-corrected STEM, in order that satisfactory performance of the device can be achieved readily, and within a short time, irrespective of the operator's skill level, a spherical-aberration-correction device with an automatic aberration-correction function was developed. This automatic aberration-correction function carries out the entire correction-related process (aberration measurement, selection and correction) automatically, with automatic selection of the aberrations that require correction, and automatic measurement of the appropriate corrections.

Observation of the Structure of Melanin Granule in Mummy's Hair Shaft Using High-Voltage Electron Microscopy (초고압전자현미경을 이용한 미라 모발 멜라닌과립의 구조 관찰)

  • Chang, Byung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.197-202
    • /
    • 2017
  • Three-dimensional melanin granules of mummy's hair analyzed using high voltage electron microscopy at 1250kV. The melanin granules in the cortex of mummy's hair located in close proximity to the outer of cortex in the adjacent place of the cuticles. A lot of melanin granule performed in this area. It is a distinguished difference from modern human. While it rotated up to 60 degree counter-clockwise and taken a photo per one degree using high voltage electron microscopy. The melanin granule displayed with long elliptical and variable at the size. The size of granule is measured from $0.3{\sim}0.6{\mu}m$ in minimum diameter and $0.5{\sim}1{\mu}m$ in maximum diameter. Conclusionally, high voltage electron microscope has higher resolution and penetration power than conventional transmission electron microscope that could be load biological thick specimen.