• 제목/요약/키워드: high-pressure gas valve

검색결과 107건 처리시간 0.027초

고압가스 충전용 밸브 개발(드레인밸브 기능포함) (Development of Rechargeable High-pressure Gas Valve (Capability of Valve to Drainage))

  • 권경옥
    • 한국가스학회지
    • /
    • 제12권3호
    • /
    • pp.64-67
    • /
    • 2008
  • 초고압 공압용 패킹을 적용한 밸브를 개발하여 밸브의 수명 및 기밀도를 높이고자 하였다. 밸브핸들 부위를 통하여 잔압을 제거할 수 있는 구조를 구현하여, 별도의 드레인밸브가 필요 없는 효과적인 밸브를 개발하였으며 특성은 밸브 팩킹을 특수한 형태로 가공하고, 기둥에 드레인 홀을 구성하여, 밸브가 열리거나, 닫힌 상태에 관계없이 드레인이 가능하도록 하였다.

  • PDF

고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석 (Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility)

  • 김명철;우정재;이형섭;백종배
    • 한국안전학회지
    • /
    • 제32권4호
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

솔레노이드 밸브를 이용한 고압가스의 유량제어 (Flow Control for High Pressure Gas by using a Solenoid Valve)

  • 심한섭;이치우;김남경;안국찬;남궁재관
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.156-161
    • /
    • 2005
  • Dynamic flow characteristics of a solenoid valve are affected by pressure difference in inlet and outlet of orifice, gas temperature, and supply voltage of a coil. In this paper, the dynamic flow characteristics for deviations of various conditions are studied Static and dynamic flow for variation on-time of a solenoid valve open signal are measured in basic bench test. The solenoid valve is applied to a compressed natural gas(CNG) engine test for validation of flow control performance. The experimental results show that flow of high pressure gas can controlled precisely by using a solenoid valve.

  • PDF

직접분사식 고압 수소분사밸브의 개발에 관한 연구 (A Study on Development of High Pressure Hydrogen Injection Valve)

  • 김윤영;안종윤;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제11권3호
    • /
    • pp.107-117
    • /
    • 2000
  • Ball poppet valve type high pressure hydrogen injection valve actuated by solenoid has been developed for the feasibility of practical use of hydrogen fueled engine with direct injection and the precise control of fuel injection ratio in hydrogen fueled engine with dual injection. The gas-tightness of ball poppet injection valve is improved by the introduction of ball-shaped valve face, valve end typed spherical pair, and valve stem with rotating blade. Ball poppet valve is mainly closed by differential pressure due to the area difference between valve fillet and pressure piston. So, it can be operated by solenoid actuator with small driving force. From the evaluation of ball poppet injection valve, it was found that the gastightness and controlment of this injection valve are better than those of injection valve had been developed before.

  • PDF

연성해석을 이용한 CNG 차량 압력 용기용 밸브의 안전성 평가 (Safety Evaluation of a Cylinder Valve for Compressed Natural Gas Vehicle Pressure Vessels using Fluid-structure Interaction Analysis)

  • 이효렬;안중환;김복만;김화영
    • 한국생산제조학회지
    • /
    • 제23권2호
    • /
    • pp.103-108
    • /
    • 2014
  • Growing concerns about environmental pollution have led to an increase in the demand for compressed natural gas (CNG) vehicles in recent years. CNG vehicles are equipped with a cylinder valve installed in a high-pressure vessel to control the CNG flow. The cylinder valve must meet high quality safety standards because the pressure vessel stores high-pressure CNG. Therefore, safety evaluation of the cylinder valve is necessary to ensure the safety of CNG vehicles. In this study, fluid-structure interaction analysis for the structural integrity of the cylinder valve were conducted using a commercial finite element analysis code(ANSYS WORKBENCH V14). The CFD analysis was performed using a steady-state technique according to the inlet and outlet pressures in order to predict the pressure distribution. Structural analysis was performed by a static structure technique at the maximum working pressure to evaluate the structural integrity of the cylinder valve. From the results, the safety factor of the valve component is between 1.57 and 21.5.

CNG차량의 연료공급라인용 Check Valve Seal의 거동해석 (Analysis of Check Valve Seal for CNG Vehicle Fuel Supply Line)

  • 유재찬;여경모;강병루;박태조
    • Tribology and Lubricants
    • /
    • 제22권6호
    • /
    • pp.329-334
    • /
    • 2006
  • In CNG (Compressed natural gas) fuel supply line, whose main components are receptacle and check valve are used to charge high pressure gas to the tank of NGV (Natural gas vehicle). It is reported that the seal is separated occasionally form valve seat and results in blockage of gas flow. In this paper, MARC is used to investigate the reasons of seal separation and suggest design improvements. The static gas pressure distributions acting on the seal which calculated using FLUENT are considered to investigate accurate seal deformation behaviors. Deformed seal shapes are obtained for various amounts of seal interference and its location, gas pressure distributions and Young's modulus of the rubber used. The results showed that the reasons of seal separation problems are verified theoretically, and suggested examples of new design method. Therefore the present numerical methods can be applied in designing and performance analysis of rubber seals adopted in high pressure fluid machineries.

고압 왕복동 압축기의 밸브 거동해석 (Valve Dynamic Analysis of a High Pressure Reciprocating Compressor)

  • 이안성;홍용주;정영식;변용수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.107-111
    • /
    • 2002
  • A complex valve dynamic analysis has been performed with a high Pressure reciprocating gas compressor. Valve dynamic equations, which take into account the flow continuity and cylinder pressure fluctuation, have been derived. Flow coefficients of valves has been analyzed, using CFD models. Results have shown that both of the suction and discharge values behave favorably without any fluttering motions.

  • PDF

고압수소 밸브의 시동 특성에 관한 수치적 연구 (A Numerical Study on the Opening Characteristics of High Pressure Hydrogen Valves)

  • 김상민;김진성;조영준;양시원;신문성
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.689-697
    • /
    • 2023
  • The high-pressure hydrogen valve is intended to supply hydrogen charged at high pressure in the hydrogen tank to the fuel cell stack, which decompresses high-pressure hydrogen gas to low pressure and primarily limits the excessive flow. It consists of a pilot valve, a main valve, and a excessive flow valve to operate in a wide pressure range from 2 to 70 MPa of charging pressure. The opening characteristics of the valve were confirmed by computation fluid dynamics applying the moving grid technique. The behavior of the valve was predicted by predicting the force acting on the valve over time. In addition, the difference in behavior according to supply pressure was compared.

스파크 점화 기관에서 밸브오버랩이 잔류가스율 변화에 미치는 영향 (Effect of Operating Conditions on the Residual Gas Fraction in an SI Engine)

  • 장진영;박용국;배충식;김우태
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.11-18
    • /
    • 2002
  • Residual gas fraction in an engine cylinder affects engine performance, efficiency and emission characteristics. With high residual gas fractions, a flame speed and maximum combustion temperature are decreased and these are deeply related with combustion stability especially at idle and NOx emission at relatively high engine load. In this work, the residual gas fraction was calculated by an engine simulation code, which was validated by the experimental data (cylinder pressure and emissions) obtained from 4-cyliner spark ignition engine. A comparison between experimental and computational calculation results was made. The residual gas is generated mostly at low engine speed by the larger pressure difference between the intake and exhaust port. As the valve overlap duration was increased, the amount of residual gas in the cylinder, the amount of HC emission in the exhaust gas and the variation of power output increased.

초저온 볼밸브의 열 응력 및 유동해석 (Thermal stress and Flow Analysis of a Cryogenic Ball Valve)

  • 배상규;이원희;김현섭;김동수
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.8-13
    • /
    • 2006
  • The high pressure cryogenic ball valve is used to transfer the liquefied natural gas which temperature is $-196^{\circ}C$, supplied pressure is $168kgf/cm^2$. In the present work, the temperature distribution and thermal deformation is calculated numerically. The CAR and CFD methods are useful to predict the thermal matter and the inner flow field of high pressure cryogenic ball valve. For this reason, to optimum design of the cryogenic ball valve, the theological behavior of the supplied LNG in a cryogenic valve has been studied. The governing equations are discredited and solved numerically by the finite-volume method and finite-element method. In this study, we designed the high pressure cryogenic ball valve that accomplishes zero leakage by elastic seal at normal temperature and metal seal at high temperature.

  • PDF